A new type of high-frequency micro-pump was designed, in which GMA (Giant Magnetostrictive Actuator) was employed to replace the traditional motor drive, owing to its significant characteristics of fast response, high...A new type of high-frequency micro-pump was designed, in which GMA (Giant Magnetostrictive Actuator) was employed to replace the traditional motor drive, owing to its significant characteristics of fast response, high accuracy, easily miniaturized and so on. Both the mathematic and simulation models of the micro-pump were built.A set of raw data was used for simulation studies.The results show that the micro-pump based on GMA has achieved the features of high-frequency response and high accuracy, theoretically displaying the performance merits of a giant magnetostrictive material (GMM) high-frequency micro-pump.展开更多
The operational stability of radial journal bearings is the bottleneck that limits the reliability of hydraulic suspension micropump. Due to self-excited vibrations, the whirl amplitude of the plain journal bearing(PJ...The operational stability of radial journal bearings is the bottleneck that limits the reliability of hydraulic suspension micropump. Due to self-excited vibrations, the whirl amplitude of the plain journal bearing(PJB) is large at high rotational speeds,which will accelerate wear failure. It has been proven that employing herringbone grooved journal bearing(HGJB) is an effective method to reduce the whirl amplitude and improve operational stability. However, enhancing the stability of journal bearings in micro-pumps by herringbone grooved structures has rarely been studied, and its effect needs to be verified. We validated the mechanism of the stability improvement with the CFD method and compared the dynamic characteristics of HGJB and PJB by rotor dynamics evaluation and experiment. The experimental results show that under the same conditions the whirl amplitude of the HGJB decreases by 29.61% in the x direction and by 24.09% in the y direction compared with that of the PJB. This study reveals the effect of the herringbone grooved structure on the operational stability of bearings and may provide guidance for the reliability improvement of hydraulic suspension micro-pump.展开更多
目的探讨丙泊酚微量泵输注联合前锯肌平面阻滞对老年胃癌根治术患者麻醉药物用量、术后谵妄及躁动影响。方法前瞻性选取2021年1月至2023年12月临汾市人民医院收治的80例老年胃癌患者作为研究对象,按照抽签法分为观察组与对照组,每组各4...目的探讨丙泊酚微量泵输注联合前锯肌平面阻滞对老年胃癌根治术患者麻醉药物用量、术后谵妄及躁动影响。方法前瞻性选取2021年1月至2023年12月临汾市人民医院收治的80例老年胃癌患者作为研究对象,按照抽签法分为观察组与对照组,每组各40例。所有患者均择期实施胃癌根治术治疗,对照组患者实施单纯全身静脉麻醉,术中采取丙泊酚微量泵注维持麻醉,观察组在对照组基础上增加前锯肌平面阻滞。对比两组麻醉效果,麻醉前(T1)、麻醉后2 min(T2)、手术开始即刻(T3)及手术结束即刻(T4)平均动脉压、血氧饱和度及心率水平变化,对比两组麻醉药物总用量,术后1、6及12 h疼痛及镇静情况,最后对比其谵妄及躁动发生率。结果观察组麻醉效果Ⅰ级患者比率为65.00%,高于对照组(37.50%),观察组麻醉效果Ⅲ级患者比率为2.50%,低于对照组(15.00%),差异均有统计学意义(P<0.05)。观察组T2、T3、T4时MAP水平分别为(80.94±6.26)、(83.37±6.52)、(92.39±5.18)mmHg,均高于对照组[(74.33±4.85)、(76.21±4.42)、(83.72±11.22)mmHg],观察组T2、T3时血氧饱和度分别为(98.84±1.67)%、(98.95±1.56)%,均高于对照组[(93.52±2.52)%、(93.12±1.53)%],观察组T2时心率为(80.36±9.27)次/min,低于对照组[(86.28±7.22)次/min],差异均有统计学意义(P<0.05)。两组患者瑞芬太尼用量比较,差异无统计学意义(P>0.05),观察组患者舒芬太尼、丙泊酚用量分别为(43.32±5.12)μg、(251.63±42.52)mg,均明显低于对照组[(46.02±7.25)μg、(281.68±56.12)mg],差异均有统计学意义(P<0.05)。观察组术后1、6、12 h Ramsay评分(1.62±0.28)、(1.08±0.15)、(0.73±0.16)级,均低于对照组[(2.81±0.31)、(1.52±0.12)、(1.03±0.12)级];观察组术后1、6、12 h VAS评分(3.41±1.23)、(2.44±0.21)、(2.17±0.31)分,均低于对照组[(4.39±1.38)、(3.57±0.11)、(3.03±0.25)分],差异均有统计学意义(P<0.05)。观察组术后谵妄及躁动发生率分别为5.00%、2.50%,均明显低于对照组(22.50%、17.50%),差异均有统计学意义(P<0.05)。结论丙泊酚微量泵输注联合前锯肌平面阻滞可提升老年胃癌根治术患者麻醉效果,稳定术中生命体征,减少麻醉药物用量,同时可提升术后镇痛及镇静效果,降低躁动及谵妄发生率。展开更多
This paper presents a three-dimensional flow field simulation of the steady flows through diffusers and nozzles with straight or serrated-sided walls to analyze the effect of the channel structure on the flow characte...This paper presents a three-dimensional flow field simulation of the steady flows through diffusers and nozzles with straight or serrated-sided walls to analyze the effect of the channel structure on the flow characteristics.The pressure and velocity profiles in the diffusers and the nozzles as well as the net volumetric flow rate are determined.Our simulation demonstrates that the pressure and velocity profiles in the serrated diffuser/nozzles are more complicated than those with the straight-sided wall,while the net steady flow rate with the straight-sided wall increases monotonically with the increase of the pressure difference,the steady flow rate with serrated sided walls increases gradually to reach a maximum and then decreases with the increase of the pressure difference.The results suggest that the number of the sawteeth plays a significant role in optimizing the design of serrated diffusers and nozzles for improving the transport efficiency of valveless micro-pumps.展开更多
基金Supported by the National Natural Science Foundation of China(59835160)the National Natural Science Foundation of Anhui Province(070414268x)
文摘A new type of high-frequency micro-pump was designed, in which GMA (Giant Magnetostrictive Actuator) was employed to replace the traditional motor drive, owing to its significant characteristics of fast response, high accuracy, easily miniaturized and so on. Both the mathematic and simulation models of the micro-pump were built.A set of raw data was used for simulation studies.The results show that the micro-pump based on GMA has achieved the features of high-frequency response and high accuracy, theoretically displaying the performance merits of a giant magnetostrictive material (GMM) high-frequency micro-pump.
基金supported by the Open Fund of Science and Technology on Thermal Energy and Power Laboratory(Grant No. TPL 2019B03)。
文摘The operational stability of radial journal bearings is the bottleneck that limits the reliability of hydraulic suspension micropump. Due to self-excited vibrations, the whirl amplitude of the plain journal bearing(PJB) is large at high rotational speeds,which will accelerate wear failure. It has been proven that employing herringbone grooved journal bearing(HGJB) is an effective method to reduce the whirl amplitude and improve operational stability. However, enhancing the stability of journal bearings in micro-pumps by herringbone grooved structures has rarely been studied, and its effect needs to be verified. We validated the mechanism of the stability improvement with the CFD method and compared the dynamic characteristics of HGJB and PJB by rotor dynamics evaluation and experiment. The experimental results show that under the same conditions the whirl amplitude of the HGJB decreases by 29.61% in the x direction and by 24.09% in the y direction compared with that of the PJB. This study reveals the effect of the herringbone grooved structure on the operational stability of bearings and may provide guidance for the reliability improvement of hydraulic suspension micro-pump.
文摘目的探讨丙泊酚微量泵输注联合前锯肌平面阻滞对老年胃癌根治术患者麻醉药物用量、术后谵妄及躁动影响。方法前瞻性选取2021年1月至2023年12月临汾市人民医院收治的80例老年胃癌患者作为研究对象,按照抽签法分为观察组与对照组,每组各40例。所有患者均择期实施胃癌根治术治疗,对照组患者实施单纯全身静脉麻醉,术中采取丙泊酚微量泵注维持麻醉,观察组在对照组基础上增加前锯肌平面阻滞。对比两组麻醉效果,麻醉前(T1)、麻醉后2 min(T2)、手术开始即刻(T3)及手术结束即刻(T4)平均动脉压、血氧饱和度及心率水平变化,对比两组麻醉药物总用量,术后1、6及12 h疼痛及镇静情况,最后对比其谵妄及躁动发生率。结果观察组麻醉效果Ⅰ级患者比率为65.00%,高于对照组(37.50%),观察组麻醉效果Ⅲ级患者比率为2.50%,低于对照组(15.00%),差异均有统计学意义(P<0.05)。观察组T2、T3、T4时MAP水平分别为(80.94±6.26)、(83.37±6.52)、(92.39±5.18)mmHg,均高于对照组[(74.33±4.85)、(76.21±4.42)、(83.72±11.22)mmHg],观察组T2、T3时血氧饱和度分别为(98.84±1.67)%、(98.95±1.56)%,均高于对照组[(93.52±2.52)%、(93.12±1.53)%],观察组T2时心率为(80.36±9.27)次/min,低于对照组[(86.28±7.22)次/min],差异均有统计学意义(P<0.05)。两组患者瑞芬太尼用量比较,差异无统计学意义(P>0.05),观察组患者舒芬太尼、丙泊酚用量分别为(43.32±5.12)μg、(251.63±42.52)mg,均明显低于对照组[(46.02±7.25)μg、(281.68±56.12)mg],差异均有统计学意义(P<0.05)。观察组术后1、6、12 h Ramsay评分(1.62±0.28)、(1.08±0.15)、(0.73±0.16)级,均低于对照组[(2.81±0.31)、(1.52±0.12)、(1.03±0.12)级];观察组术后1、6、12 h VAS评分(3.41±1.23)、(2.44±0.21)、(2.17±0.31)分,均低于对照组[(4.39±1.38)、(3.57±0.11)、(3.03±0.25)分],差异均有统计学意义(P<0.05)。观察组术后谵妄及躁动发生率分别为5.00%、2.50%,均明显低于对照组(22.50%、17.50%),差异均有统计学意义(P<0.05)。结论丙泊酚微量泵输注联合前锯肌平面阻滞可提升老年胃癌根治术患者麻醉效果,稳定术中生命体征,减少麻醉药物用量,同时可提升术后镇痛及镇静效果,降低躁动及谵妄发生率。
基金the National Natural Science Foundation of China(Grant Nos.61376115,11672065).
文摘This paper presents a three-dimensional flow field simulation of the steady flows through diffusers and nozzles with straight or serrated-sided walls to analyze the effect of the channel structure on the flow characteristics.The pressure and velocity profiles in the diffusers and the nozzles as well as the net volumetric flow rate are determined.Our simulation demonstrates that the pressure and velocity profiles in the serrated diffuser/nozzles are more complicated than those with the straight-sided wall,while the net steady flow rate with the straight-sided wall increases monotonically with the increase of the pressure difference,the steady flow rate with serrated sided walls increases gradually to reach a maximum and then decreases with the increase of the pressure difference.The results suggest that the number of the sawteeth plays a significant role in optimizing the design of serrated diffusers and nozzles for improving the transport efficiency of valveless micro-pumps.