The performance of a biofilter for off-gas treatment relies on the activity of microorganisms and adequate O_2 and H_2O. In present study, a microelectrode was applied to analyze O_2 in polyurethane foam cubes(PUFCs...The performance of a biofilter for off-gas treatment relies on the activity of microorganisms and adequate O_2 and H_2O. In present study, a microelectrode was applied to analyze O_2 in polyurethane foam cubes(PUFCs) packed in a biofilter for SO_2 removal. The O_2 distribution varied with the density and water-containing rate(WCR) of PUFCs. The O_2 concentration dropped sharply from 10.2 to 0.8 mg/L from the surface to the center of a PUFC with 97.20%of WCR. The PUFCs with high WCR presented aerobic–anoxic–aerobic areas.Three-dimensional simulated images demonstrated that the structure of PUFCs with high WCR consisted of an aerobic "shell" and an anoxic "core", with high-density PUFCs featuring a larger anoxic area than low-density PUFCs. Moreover, the H_2O distribution in the PUFC was uneven and affected the O_2 concentration. Whereas aerobic bacteria were observed in the PUFC surface, facultative anaerobic microorganisms were found at the PUFC core, where the O_2 concentration was relatively low. O_2 and H_2O distributions differed in the PUFCs, and the distribution of microorganisms varied accordingly.展开更多
基金financially supported by the Major Science and Technology Program for Water Pollution Control and Treatment(No.2010ZX07319-001-03)the National Natural Science Foundation of China(No.51221892)
文摘The performance of a biofilter for off-gas treatment relies on the activity of microorganisms and adequate O_2 and H_2O. In present study, a microelectrode was applied to analyze O_2 in polyurethane foam cubes(PUFCs) packed in a biofilter for SO_2 removal. The O_2 distribution varied with the density and water-containing rate(WCR) of PUFCs. The O_2 concentration dropped sharply from 10.2 to 0.8 mg/L from the surface to the center of a PUFC with 97.20%of WCR. The PUFCs with high WCR presented aerobic–anoxic–aerobic areas.Three-dimensional simulated images demonstrated that the structure of PUFCs with high WCR consisted of an aerobic "shell" and an anoxic "core", with high-density PUFCs featuring a larger anoxic area than low-density PUFCs. Moreover, the H_2O distribution in the PUFC was uneven and affected the O_2 concentration. Whereas aerobic bacteria were observed in the PUFC surface, facultative anaerobic microorganisms were found at the PUFC core, where the O_2 concentration was relatively low. O_2 and H_2O distributions differed in the PUFCs, and the distribution of microorganisms varied accordingly.