Droplet manipulation on an open surface has great potential in chemical analysis and biomedicine engineering.However,most of the reported platforms designed for the manipulation of water droplets cannot thoroughly sol...Droplet manipulation on an open surface has great potential in chemical analysis and biomedicine engineering.However,most of the reported platforms designed for the manipulation of water droplets cannot thoroughly solve the problem of droplet evaporation.Herein,we report a shape-reconfigurable micropillar array chip for the manipulation of water droplets,oil droplets and water-in-oil droplets.Water-in-oil droplets provide an enclosed space for water droplets,preventing the evaporation in an open environment.Perfluoropolyether coated on the surface of the chip effectively reduces the droplet movement resistance.The micropillar array chip has light and magnetic dual-response due to the Fe3O4 nanoparticles and the reduced iron powder mixed in the shape-memory polymer.The micropillars irradiated by a near-infrared laser bend under the magnetic force,while the unirradiated micropillars still keep their original shape.In the absence of a magnetic field,when the micropillars in a temporary shape are irradiated by the near-infrared laser to the transition temperature,the micropillars return to their initial shape.In this process,the surface morphology gradient caused by the deformation of the micropillars and the surface tension gradient caused by the temperature change jointly produce the driving force of droplet movement.展开更多
Flow through arrays of micropillar embedded inside microfluidic chip systems is important for various microfluidic devices. It is critical to accurately predict the mass flow rate through pillar arrays based on the pi...Flow through arrays of micropillar embedded inside microfluidic chip systems is important for various microfluidic devices. It is critical to accurately predict the mass flow rate through pillar arrays based on the pillar design. This work presents a dissipative particle dynamics (DPD) model to simulate a problem of flow across periodic arrays of circular micropillar and investigates the permeability of two types of micropillar arrays. The flow fields including horizontal and vertical velocity fields, the number density field, and the streamline of the flow are analyzed. The predicted solid volumes by the presented DPD simulation of both types of arrays are quite close to the actual counterparts. These quantitative agreements show usefulness and effectiveness of the DPD model in simulating arrays of micropillar. By comparing two types of micropillar arrangement patterns, we find that the arrangement pattern of micropillar does not have significant influence on the permeability of the array.展开更多
基金the Natural Science Foundation of China(No.21874015)the Fundamental Research Funds for the Central Universities(No.N2005024).
文摘Droplet manipulation on an open surface has great potential in chemical analysis and biomedicine engineering.However,most of the reported platforms designed for the manipulation of water droplets cannot thoroughly solve the problem of droplet evaporation.Herein,we report a shape-reconfigurable micropillar array chip for the manipulation of water droplets,oil droplets and water-in-oil droplets.Water-in-oil droplets provide an enclosed space for water droplets,preventing the evaporation in an open environment.Perfluoropolyether coated on the surface of the chip effectively reduces the droplet movement resistance.The micropillar array chip has light and magnetic dual-response due to the Fe3O4 nanoparticles and the reduced iron powder mixed in the shape-memory polymer.The micropillars irradiated by a near-infrared laser bend under the magnetic force,while the unirradiated micropillars still keep their original shape.In the absence of a magnetic field,when the micropillars in a temporary shape are irradiated by the near-infrared laser to the transition temperature,the micropillars return to their initial shape.In this process,the surface morphology gradient caused by the deformation of the micropillars and the surface tension gradient caused by the temperature change jointly produce the driving force of droplet movement.
基金Project supported by the National Natural Science Foundation of China(Nos.31370953,10942004,and 91230203)
文摘Flow through arrays of micropillar embedded inside microfluidic chip systems is important for various microfluidic devices. It is critical to accurately predict the mass flow rate through pillar arrays based on the pillar design. This work presents a dissipative particle dynamics (DPD) model to simulate a problem of flow across periodic arrays of circular micropillar and investigates the permeability of two types of micropillar arrays. The flow fields including horizontal and vertical velocity fields, the number density field, and the streamline of the flow are analyzed. The predicted solid volumes by the presented DPD simulation of both types of arrays are quite close to the actual counterparts. These quantitative agreements show usefulness and effectiveness of the DPD model in simulating arrays of micropillar. By comparing two types of micropillar arrangement patterns, we find that the arrangement pattern of micropillar does not have significant influence on the permeability of the array.