Thanks to the strong perpendicular magnetic anisotropy(PMA), excellent processing compatibility as well as novel spintronic phenomenon, Co/Pt multilayers have been attracting massive attention and widely used in magne...Thanks to the strong perpendicular magnetic anisotropy(PMA), excellent processing compatibility as well as novel spintronic phenomenon, Co/Pt multilayers have been attracting massive attention and widely used in magnetic storage.However, reversed magnetic domains come into being with the increasing layer repetition ‘N’ to reduce magneto-static energy, resulting in the remarkable diminishment of the remanent magnetization(Mr). As a result, the product of Mrand thickness(i.e., the remanent moment-thickness product, Mrt), a key parameter in magnetic recording for reliable data storing and reading, also decreases dramatically. To overcome this issue, we deposit an ultra-thick granular [Co/Pt]80multilayer with a total thickness of 68 nm on granular SiNxbuffer layer. The Mrt value, Mrto saturation magnetization(Ms) ratio as well as out of plane(OOP) coercivity(Hcoop) are high up to 2.97 memu/cm^(2), 67%, and 1940 Oe(1 Oe = 79.5775 A·m^(-1)),respectively, which is remarkably improved compared with that of continuous [Co/Pt]80multilayers. That is because large amounts of grain boundaries in the granular multilayers can efficiently impede the propagation and expansion of reversed magnetic domains, which is verified by experimental investigations and micromagnetic simulation results. The simulation results also indicate that the value of Mrt, Mr/Msratio, and Hcoopcan be further improved through optimizing the granule size, which can be experimentally realized by manipulating the process parameter of SiNxbuffer layer. This work provides an alternative solution for achieving high Mrt value in ultra-thick Co/Pt multilayers, which is of unneglectable potential in applications of high-density magnetic recording.展开更多
A microelectrode array(MEA) is presented, which is composed of 60 independent electrodes with 59 working ones and one reference one, and they are divided into 30 pairs. Except for the reference electrode, each pair ...A microelectrode array(MEA) is presented, which is composed of 60 independent electrodes with 59 working ones and one reference one, and they are divided into 30 pairs. Except for the reference electrode, each pair consists of one stimulating electrode and one recording electrode. Supported by the peripheral circuits, four electrode states to study the bioelectrical signal of biological tissue or slice cultured in-vitro on the surface of the electrodes can be realized through each pair of electrodes. The four electrode states are stimulation, recording, stimulation and recording simultaneously, and isolation. The state of each pair of working electrodes can be arbitrarily controlled according to actual needs. The MEAs are fabricated in printed circuit board (PCB) technology. The total area of the PCB-based MEA is 49 mm × 49 mm. The impedance measurement of MEA is carried out in 0.9% sodium chloride solution at room temperature by means of 2-point measurements with an Agilent LCR meter, and the test signal for the impedance measurement is sinusoidal (AC voltage 50 mV, sweeping frequency 20 Hz to 10 kHz). The electrode impedance is between 200 and 3 kΩ while the frequency is between 500 and 1 000 Hz. The electrode impedance magnitude is inversely proportional to the frequency. Experiments of toad sciatic nerve in-vitro stimulation and recording and signal regeneration between isolated toad sciatic nerves are carried out on the PCB-based MEA. The results show that the MEA can be used for bioelectrical signal stimulation, recording, stimulation and recording simultaneously, and isolation of biological tissues or slices in-vitro.展开更多
The authors used suspension cells of Populus euphratica to isolate protoplast in the present study. Protoplasts were successfully obtained after 4 hours incubation in enzyme solution containing 1 0% cellulase “o...The authors used suspension cells of Populus euphratica to isolate protoplast in the present study. Protoplasts were successfully obtained after 4 hours incubation in enzyme solution containing 1 0% cellulase “onozuka” R\|10, 0\^01% pectolyase Y\|23,0\^15% macerozyme R\|10 and 0\^1% hemicellulase at 25℃. Outward and inward single channels in plasma membrane were observed using cell\|attached recording of patch\|clamp technique. In this study, single channel records showed that more than one species of channel were obtained. These attempts in protoplast isolation and ion channel recording offers the opportunity to characterize cellular mechanisms of salt tolerance in tree species.展开更多
A model following adaptive control system for CSIM is presented in this paper. A dynamic mathematical model of slip control based system is obtained. With the help of model reducing technique, full order model is ...A model following adaptive control system for CSIM is presented in this paper. A dynamic mathematical model of slip control based system is obtained. With the help of model reducing technique, full order model is reduced to simplify the design without degrading much of the performance. Model following adaptive control laws in discrete form are derived. These laws satisfy the hyperstability condition for taking care of the load and machine parameter changes of the drive. A microprocessor 8098 is used to develop the speed controller. The implementation of the control system uses only available variables of the reference model and the controlled plant. Experimental results are given to demonstrate the good performance of the system.展开更多
Objective To re-confirm and characterize the biophysical and pharmacological properties of endogenously expressed human acid-sensing ion channel 1a (hASIC1a) current in HEK293 cells with a modified perfusion methods...Objective To re-confirm and characterize the biophysical and pharmacological properties of endogenously expressed human acid-sensing ion channel 1a (hASIC1a) current in HEK293 cells with a modified perfusion methods. Methods With cell floating method, which is separating the cultured cell from coverslip and putting the cell in front of perfusion tubing, whole cell patch clamp technique was used to record hASICla currents evoked by low pH external solution. Results Using cell floating method, the amplitude of hASICla currents activated by pH 5.0 in HEK293 cells is twice as large as that by the conventional method where the cells remain attached to coverslip. The time to reach peak at two different recording conditions is (21±5) ms and (270±25) ms, respectively. Inactivation time constants are (496±23) ms and (2284±120) ms, respectively. The cell floating method significantly increases the amiloride potency of block on hASIC 1 a [IC50 is (3.4± 1.1 ) μmol/L and (2.4± 0.9) μmol/L, respectively]. Both recording methods have similar pH activation ECs0 (6.6±0.6, 6.6±0.7, respectively). Conclusion ASICs channel activation requires fast exchange of extracellular solution with the different pH values. With cell floating method, the presence of hASIC la current was re-confirmed and the biophysical and pharmacological properties of hASIC la channel in HEK293 cells was precisely characterized. This method could be used to study all ASICs and other ligand-gated channels that require fast extracellular solution exchange.展开更多
We report on new experimental results for below-diffraction-limited hybrid recording. In our experiments, by means of focused laser assisted magnetic recording, the magnetic domains within TbFeCo thin films are obtain...We report on new experimental results for below-diffraction-limited hybrid recording. In our experiments, by means of focused laser assisted magnetic recording, the magnetic domains within TbFeCo thin films are obtained under an external perpendicular direct magnetic field. For a single magnetic medium, the domain size is mainly determined by the focused spot, which is about 620 nm for the laser wavelength λ=406 nm, and a numerical aperture of the lens of 0.80. However, when a silicon thin film structure is inserted between the substrate and the magnetic medium, the recording domains can be reduced obviously. By optimizing the experimental condition, even the size can be reduced to about 100 nm, which is below the diffraction limit, i.e. about 1/6 of the spot size. This is very useful for improving the hybrid recording density in practical applications.展开更多
Local site conditions play an important role in the effective application of strong motion recordings.In the China National Strong Motion Observation Network System(NSMONS),some of the stations do not provide boreho...Local site conditions play an important role in the effective application of strong motion recordings.In the China National Strong Motion Observation Network System(NSMONS),some of the stations do not provide borehole information,and correspondingly,do not assign the site classes yet.In this paper,site classification methodologies for free-field strong motion stations are reviewed and the limitations and uncertainties of the horizontal-to-vertical spectral ratio(HVSR) methods are discussed.Then,a new method for site classification based on the entropy weight theory is proposed.The proposed method avoids the head or tail joggle phenomenon by providing the objective and subjective weights.The method was applied to aftershock recordings from the 2008 Wenchuan earthquake,and 54 free-field NSMONS stations were selected for site classification and the mean HVSRs were calculated.The results show that the improved HVSR method proposed in this paper has a higher success rate and could be adopted in NSMONS.展开更多
The thickness of CoP thin films prepared by wet chemical deposition is of crucial importance on magnetic property and recording perform-ance. The coercivity of CoP films decreased with increasing film thickness. The c...The thickness of CoP thin films prepared by wet chemical deposition is of crucial importance on magnetic property and recording perform-ance. The coercivity of CoP films decreased with increasing film thickness. The coercivity was 45.37 kA m 1 at the thickness of 300 nm, and decreased to 21.65 kA m 1 at 5.7 μm. Recording performance tests indicate that, for drums with the same size, different recorded magnetic pole density have different thickness requirements. For 40 mm diameter magnetic drum, the optimal CoP thickness is 3~10 μm for 256 re-corded magnetic poles, 1~2 μm for 512 recorded magnetic poles, and 500~800 nm for 1024 recorded magnetic poles.展开更多
In this paper a fault location and recording system based on a computer network is presented. A brief description of the system structure and main features are given. Emphasis is placed on the accurate fault location ...In this paper a fault location and recording system based on a computer network is presented. A brief description of the system structure and main features are given. Emphasis is placed on the accurate fault location method for extra high voltage and long distance transmission lines.展开更多
Current practice uses predictive models to extrapolate long-period response spectra based on far-field recordings in moderate and weak earthquakes. However, the spectra are not long enough and the data are often not r...Current practice uses predictive models to extrapolate long-period response spectra based on far-field recordings in moderate and weak earthquakes. However, the spectra are not long enough and the data are often not reliable, which means that the seismic design code cannot accurately define seismic design requirements for long-period structures. The near-field recordings in the main-shock of the Chi-Chi earthquake have a large signal-to-noise ratio (SNR), which makes them suitable for studying the long-period acceleration response spectrum up to 20 sec. The acceleration response spectra from 246 stations within 120 km of the causative fault are statistically analyzed in this paper. The influence of distance and site conditions on long-period response spectrum is discussed, and the shapes of the amplification spectra are compared with the standard spectra specified in the seismic design code of China. Finally, suggestions for future revisions to the code are proposed.展开更多
The advantages of read-only storage is the predominance of optical recording relative to magnetic and other rewritable methods. Multilevel (ML) read-only technology has been a trend to improve the data capacity and ...The advantages of read-only storage is the predominance of optical recording relative to magnetic and other rewritable methods. Multilevel (ML) read-only technology has been a trend to improve the data capacity and transfer rate. Based on the principle and coding method of ML, this paper demonstrates some ML read-only recording methods, of which a new ML read-only recording is developed. This recording method integrates amplitude modulation achieved by the reaction mechanism of physics and chemistry of photoresist with the run-length-limited technology. The discs can be achieved using standard photoresist mastering and replication techniques with great compatibility to conventional binary read-only discs.展开更多
Determining the upper boundary of the cobalt-rich crust distribution of a guyot is important for estimating the mineral resources available, however, it has also long been an unsolved question. Correlations between th...Determining the upper boundary of the cobalt-rich crust distribution of a guyot is important for estimating the mineral resources available, however, it has also long been an unsolved question. Correlations between the sub-bottom structures, revealed by sub-bottom profiling, and crust distribution can be revealed for the first time by the synchronous application of sub-bottom profiling and deep-sea video recording. The lower boundary of the sediment corresponds with the upper boundary of the crust. By analysis of these two kinds of data, the lower boundary of the sediment can be determined; therefore, the upper boundary of the crust distribution can be deduced. According to this method of analysis, the upper boundary of water depth of crust distribution of a seamount in the western Pacific is about 1 560 m.展开更多
A new kind of simple and flexible CO2 welding system was developed to carry out waveform control. The system consisted of IGBT inverter, PWM circuit and microprocessor unit ( MPU) , in which the output current of co...A new kind of simple and flexible CO2 welding system was developed to carry out waveform control. The system consisted of IGBT inverter, PWM circuit and microprocessor unit ( MPU) , in which the output current of constant current (CC) power supply could be changed according to transient physical state, and the variable down slope rate control could be used to ensure a stable welding process. The welding experiment results proved the effectiveness of this control approach.展开更多
The patch clamp recording technique in vivois a blind patch clamp recording methods to record the current of the spinal or cereral neurons of anaes:hesia ( or awake) animals. This technique can be used to study the...The patch clamp recording technique in vivois a blind patch clamp recording methods to record the current of the spinal or cereral neurons of anaes:hesia ( or awake) animals. This technique can be used to study the synaptic function and plasticity in central nervous system in vivoin order to understand the physiological properties of the ion channels from an integrated point of view. The advantage of this technique have already presented itself in the study of the synaptic transmission and nervous network. Nowadays, in vivo patch whole-cell recording technique in combination with other techniques is becoming a common method in the research fields.展开更多
Virtual memory management is always a very essential issue of the modern microprocessor design. A memory management unit (MMU) is designed to implement a virtual machine for user programs, and provides a management me...Virtual memory management is always a very essential issue of the modern microprocessor design. A memory management unit (MMU) is designed to implement a virtual machine for user programs, and provides a management mechanism between the operating system and user programs. This paper analyzes the tradeoffs considered in the MMU design of Unity 11 CPU of Peking University, and introduces in detail the solution of pure hardware table walking with two level page table organization. The implementation takes care of required operations and high performances needed by modern operating systems and low costs needed by embedded systems. This solution has been silicon proven, and successfully porting the Linux 2.4.17 kernel, the XWindow system, GNOME and most application software onto the Unity platform.展开更多
Cr/SmCo/Cr thin films with Sm concentration of 37.7 at.% were deposited on glass substrates by magnetron sputtering. Measurement of magnetic properties showed that the SmCo film possessed good magnetic anisotropy, a h...Cr/SmCo/Cr thin films with Sm concentration of 37.7 at.% were deposited on glass substrates by magnetron sputtering. Measurement of magnetic properties showed that the SmCo film possessed good magnetic anisotropy, a high coercivity of 3019 kA/m and low magnetic exchange coupling. Microstructure analysis showed that crystallized SmCo5 magnetic phase, non-magnetic SmCo2 phase and Sm2Co7 phase co-existed in the film. The non-magnetic SmCo2 phase might function as isolator of SmCo grains, leading to a decrease of magnetic exchange coupling. Moreover, a Cr2O3 oxide layer which could protect the SmCo layer from oxidation formed at the surface of the Cr cap layer.展开更多
AIM: To record calcium and potassium currents in acutely isolated smooth muscle cells of mesenteric arterial branches in rats. METHODS: Smooth muscle cells were freshly isolated by collagenase digest and mechanical ...AIM: To record calcium and potassium currents in acutely isolated smooth muscle cells of mesenteric arterial branches in rats. METHODS: Smooth muscle cells were freshly isolated by collagenase digest and mechanical trituration with polished pipettes. Patch clamp technique in whole-cell mode was employed to record calcium and potassium currents. RESULTS: The procedure dissociated smooth muscle cells without impairing the electrophysiological characteristics of the cells. The voltage-gated Ca^2+ and potassium currents were successfully recorded using whole-cell patch clamp configuration. CONCLUSION: The method dissociates smooth muscle cells from rat mesenteric arterial branches. Voltage-gated channel currents can be recorded in this preparation.展开更多
BACKGROUND: Electrophysiological properties of the song nucleus have been revealed using conventional techniques, such as intracellular and extracellular recording. Research concerning the neuronal activation propert...BACKGROUND: Electrophysiological properties of the song nucleus have been revealed using conventional techniques, such as intracellular and extracellular recording. Research concerning the neuronal activation properties and regulations of the song system at the cellular and ion channel level may help reveal the neural mechanism of song learning. OBJECTIVE: To perform whole-cell recording of robust nucleus of the arcopallium (RA) neurons in brain slices from adult zebra finches (Taeniopygia guttata) and observe the action potential, sodium/potassium current and the spontaneous postsynaptic current of RA neurons. DESIGN, TIME AND SETTING: Self-controlled, neuroelectrophysiological experiment. The study was performed at the Neurophysiology Laboratory of South China Normal University from April to September 2008. MATERIALS: Flaming/Brown puller P-97 was purchased from Sutter Ins, USA; Axopatch 700B amplifier and Digidata 1332A converter were purchased from Axon Instrument, USA; pClamp software was provided by Axon Instrument, USA. METHODS: RA neurons were acutely isolated from 24 healthy male zebra finches. The action potential, voltage-gate sodium/potassium current and spontaneous postsynaptic current were recorded by whole-cell recording technology. Data were analyzed by pClamp software. MAIN OUTCOME MEASURES: The amplitude and frequency of the action potential, and the amplitude of the voltage-dependent and spontaneous postsynaptic currents, were measured. RESULTS: (1) Testing of action potential: Cells exhibited a stable current-voltage relationship following a series of hyperpolarization stepped currents, and an action potential was triggered by the spike threshold. All the recorded cells displayed repetitive firing following depolarizing current injection, with a frequency beyond 100 Hz. (2) Testing of voltage-gate currents: The inward and outward whole-cell currents were observed after a series of depolarizing voltage steps. The inward current disappeared following the application of tetrodotoxin and the outward current was significantly inhibited by application of 4-aminopyfidione and tetraethylammonium chloride. (3) Testing of spontaneous postsynaptic current: The majority of recorded cells exhibited an inward synaptic current when the membrane potential was maintained at -60 mV, with some cells exhibiting a robustly outward current when the membrane potential was maintained at -30 mV. Tetrodotoxin was unable to affect the spontaneous postsynaptic current. Following application of bicuculline [y-aminobutyric acid (A) receptor antagonist] and high concentration kynurenic acid (ionotropic glutamate receptor antagonist), the inward and outward currents were completely inhibited. CONCLUSION: Under these experimental conditions, the action potential, sodium/potassium current and spontaneous postsynaptic current were recorded successfully in RA neurons. This indicates that the cells preserved relatively intact synaptic connections and normal physiological activity, which is required for investigating ion channels. The inward and outward whole-cell currents were sodium and potassium currents, respectively. The postsynaptic y-aminobutyric acid (A) receptors and ionotropic glutamate receptors contributed to the spontaneous postsynaptic current.展开更多
Microneedle array(MNA)electrodes are an effective solution to achieve high-quality surface biopotential recording without the coordination of conductive gel and are thus very suitable for long-term wearable applicatio...Microneedle array(MNA)electrodes are an effective solution to achieve high-quality surface biopotential recording without the coordination of conductive gel and are thus very suitable for long-term wearable applications.Existing schemes are limited by flexibility,biosafety,and manufacturing costs,which create large barriers for wider applications.Here,we present a novel flexible MNA electrode that can simultaneously achieve flexibility of the substrate to fit a curved body surface,robustness of microneedles to penetrate the skin without fracture,and a simplified process to allow mass production.The compatibility with wearable wireless systems and the short preparation time of the electrodes significantly improves the comfort and convenience of electrophysiological recording.The normalized electrode–skin contact impedance reaches 0.98 kΩcm^(2)at 1 kHz and 1.50 kΩcm^(2)at 10 Hz,a record low value compared to previous reports and approximately 1/250 of the standard electrodes.The morphology,biosafety,and electrical/mechanical properties are fully characterized,and wearable recordings with a high signal-to-noise ratio and low motion artifacts are realized.The first reported clinical study of microneedle electrodes for surface electrophysiological monitoring was conducted in tens of healthy and sleep-disordered subjects with 44 nights of recording(over 8 h per night),providing substantial evidence that the electrodes can be leveraged to substitute for clinical standard electrodes.展开更多
The article discusses the possibility of further modernization of the standard microprocessor relay protection of AC overhead system feeders DPA-27.5-TNF, which is operated on the Trans-Baikal Railway by creating an a...The article discusses the possibility of further modernization of the standard microprocessor relay protection of AC overhead system feeders DPA-27.5-TNF, which is operated on the Trans-Baikal Railway by creating an additional automated system of unified templates necessary for the occurrence of “trainability” elements. The templates will be formed via a separate dedicated channel for transmission, processing and storage of the necessary information, not related to the operation of the terminal, with its subsequent visualization at the workplace of the duty personnel of traction substations, together with information from the “GID” software received via another dedicated wired channel. With the help of such a base of unified preset templates, in the future, it will be possible not only to identify the specific causes of each emergency shutdown but also to reduce their number by dynamically adjusting the existing presets of the standard operation algorithm.展开更多
基金supported by the National Natural Science Foundation of China (Grant No. 51901008)the National Key Research and Development Program of China (Grant No. 2021YFB3201800)。
文摘Thanks to the strong perpendicular magnetic anisotropy(PMA), excellent processing compatibility as well as novel spintronic phenomenon, Co/Pt multilayers have been attracting massive attention and widely used in magnetic storage.However, reversed magnetic domains come into being with the increasing layer repetition ‘N’ to reduce magneto-static energy, resulting in the remarkable diminishment of the remanent magnetization(Mr). As a result, the product of Mrand thickness(i.e., the remanent moment-thickness product, Mrt), a key parameter in magnetic recording for reliable data storing and reading, also decreases dramatically. To overcome this issue, we deposit an ultra-thick granular [Co/Pt]80multilayer with a total thickness of 68 nm on granular SiNxbuffer layer. The Mrt value, Mrto saturation magnetization(Ms) ratio as well as out of plane(OOP) coercivity(Hcoop) are high up to 2.97 memu/cm^(2), 67%, and 1940 Oe(1 Oe = 79.5775 A·m^(-1)),respectively, which is remarkably improved compared with that of continuous [Co/Pt]80multilayers. That is because large amounts of grain boundaries in the granular multilayers can efficiently impede the propagation and expansion of reversed magnetic domains, which is verified by experimental investigations and micromagnetic simulation results. The simulation results also indicate that the value of Mrt, Mr/Msratio, and Hcoopcan be further improved through optimizing the granule size, which can be experimentally realized by manipulating the process parameter of SiNxbuffer layer. This work provides an alternative solution for achieving high Mrt value in ultra-thick Co/Pt multilayers, which is of unneglectable potential in applications of high-density magnetic recording.
基金The National Natural Science Foundation of China(No. 61076118, 90307013, 90707005)the Natural Science Foundation of Jiangsu Province (No. BK2008032)Special Foundation and Open Foundation of the State Key Laboratory of Bioelectronics of Southeast University
文摘A microelectrode array(MEA) is presented, which is composed of 60 independent electrodes with 59 working ones and one reference one, and they are divided into 30 pairs. Except for the reference electrode, each pair consists of one stimulating electrode and one recording electrode. Supported by the peripheral circuits, four electrode states to study the bioelectrical signal of biological tissue or slice cultured in-vitro on the surface of the electrodes can be realized through each pair of electrodes. The four electrode states are stimulation, recording, stimulation and recording simultaneously, and isolation. The state of each pair of working electrodes can be arbitrarily controlled according to actual needs. The MEAs are fabricated in printed circuit board (PCB) technology. The total area of the PCB-based MEA is 49 mm × 49 mm. The impedance measurement of MEA is carried out in 0.9% sodium chloride solution at room temperature by means of 2-point measurements with an Agilent LCR meter, and the test signal for the impedance measurement is sinusoidal (AC voltage 50 mV, sweeping frequency 20 Hz to 10 kHz). The electrode impedance is between 200 and 3 kΩ while the frequency is between 500 and 1 000 Hz. The electrode impedance magnitude is inversely proportional to the frequency. Experiments of toad sciatic nerve in-vitro stimulation and recording and signal regeneration between isolated toad sciatic nerves are carried out on the PCB-based MEA. The results show that the MEA can be used for bioelectrical signal stimulation, recording, stimulation and recording simultaneously, and isolation of biological tissues or slices in-vitro.
文摘The authors used suspension cells of Populus euphratica to isolate protoplast in the present study. Protoplasts were successfully obtained after 4 hours incubation in enzyme solution containing 1 0% cellulase “onozuka” R\|10, 0\^01% pectolyase Y\|23,0\^15% macerozyme R\|10 and 0\^1% hemicellulase at 25℃. Outward and inward single channels in plasma membrane were observed using cell\|attached recording of patch\|clamp technique. In this study, single channel records showed that more than one species of channel were obtained. These attempts in protoplast isolation and ion channel recording offers the opportunity to characterize cellular mechanisms of salt tolerance in tree species.
文摘A model following adaptive control system for CSIM is presented in this paper. A dynamic mathematical model of slip control based system is obtained. With the help of model reducing technique, full order model is reduced to simplify the design without degrading much of the performance. Model following adaptive control laws in discrete form are derived. These laws satisfy the hyperstability condition for taking care of the load and machine parameter changes of the drive. A microprocessor 8098 is used to develop the speed controller. The implementation of the control system uses only available variables of the reference model and the controlled plant. Experimental results are given to demonstrate the good performance of the system.
文摘Objective To re-confirm and characterize the biophysical and pharmacological properties of endogenously expressed human acid-sensing ion channel 1a (hASIC1a) current in HEK293 cells with a modified perfusion methods. Methods With cell floating method, which is separating the cultured cell from coverslip and putting the cell in front of perfusion tubing, whole cell patch clamp technique was used to record hASICla currents evoked by low pH external solution. Results Using cell floating method, the amplitude of hASICla currents activated by pH 5.0 in HEK293 cells is twice as large as that by the conventional method where the cells remain attached to coverslip. The time to reach peak at two different recording conditions is (21±5) ms and (270±25) ms, respectively. Inactivation time constants are (496±23) ms and (2284±120) ms, respectively. The cell floating method significantly increases the amiloride potency of block on hASIC 1 a [IC50 is (3.4± 1.1 ) μmol/L and (2.4± 0.9) μmol/L, respectively]. Both recording methods have similar pH activation ECs0 (6.6±0.6, 6.6±0.7, respectively). Conclusion ASICs channel activation requires fast exchange of extracellular solution with the different pH values. With cell floating method, the presence of hASIC la current was re-confirmed and the biophysical and pharmacological properties of hASIC la channel in HEK293 cells was precisely characterized. This method could be used to study all ASICs and other ligand-gated channels that require fast extracellular solution exchange.
基金Project supported by the National Natural Science Foundation of China (Grant Nos 50772120 and 60490290)Funds of the Chinese Academy of Sciences for Key Topics in Innovation Engineering (Grant No KJCXZYW.NANO.06)the National Basic Research Program of China (Grant No 2007CB935400)
文摘We report on new experimental results for below-diffraction-limited hybrid recording. In our experiments, by means of focused laser assisted magnetic recording, the magnetic domains within TbFeCo thin films are obtained under an external perpendicular direct magnetic field. For a single magnetic medium, the domain size is mainly determined by the focused spot, which is about 620 nm for the laser wavelength λ=406 nm, and a numerical aperture of the lens of 0.80. However, when a silicon thin film structure is inserted between the substrate and the magnetic medium, the recording domains can be reduced obviously. By optimizing the experimental condition, even the size can be reduced to about 100 nm, which is below the diffraction limit, i.e. about 1/6 of the spot size. This is very useful for improving the hybrid recording density in practical applications.
基金National Key Technology R&D Program Under Grant No.2009BAK55B05Nonprofit Industry Research Project of CEA Under Grant No.201108003Science Foundation of Institute of Engineering Mechanics,CEA Under Grant No.2010C01
文摘Local site conditions play an important role in the effective application of strong motion recordings.In the China National Strong Motion Observation Network System(NSMONS),some of the stations do not provide borehole information,and correspondingly,do not assign the site classes yet.In this paper,site classification methodologies for free-field strong motion stations are reviewed and the limitations and uncertainties of the horizontal-to-vertical spectral ratio(HVSR) methods are discussed.Then,a new method for site classification based on the entropy weight theory is proposed.The proposed method avoids the head or tail joggle phenomenon by providing the objective and subjective weights.The method was applied to aftershock recordings from the 2008 Wenchuan earthquake,and 54 free-field NSMONS stations were selected for site classification and the mean HVSRs were calculated.The results show that the improved HVSR method proposed in this paper has a higher success rate and could be adopted in NSMONS.
基金supported by the National Natural Science Foundation of China (No. 51101013)Specialized Research Fund for the Doctoral Program of Higher Education of China(No. 20090006120013)the Fundamental Research Funds for the Central Universities (FRF-TP-12-038A)
文摘The thickness of CoP thin films prepared by wet chemical deposition is of crucial importance on magnetic property and recording perform-ance. The coercivity of CoP films decreased with increasing film thickness. The coercivity was 45.37 kA m 1 at the thickness of 300 nm, and decreased to 21.65 kA m 1 at 5.7 μm. Recording performance tests indicate that, for drums with the same size, different recorded magnetic pole density have different thickness requirements. For 40 mm diameter magnetic drum, the optimal CoP thickness is 3~10 μm for 256 re-corded magnetic poles, 1~2 μm for 512 recorded magnetic poles, and 500~800 nm for 1024 recorded magnetic poles.
文摘In this paper a fault location and recording system based on a computer network is presented. A brief description of the system structure and main features are given. Emphasis is placed on the accurate fault location method for extra high voltage and long distance transmission lines.
基金National Natural Science Foundation of China Under Grant No.40374017
文摘Current practice uses predictive models to extrapolate long-period response spectra based on far-field recordings in moderate and weak earthquakes. However, the spectra are not long enough and the data are often not reliable, which means that the seismic design code cannot accurately define seismic design requirements for long-period structures. The near-field recordings in the main-shock of the Chi-Chi earthquake have a large signal-to-noise ratio (SNR), which makes them suitable for studying the long-period acceleration response spectrum up to 20 sec. The acceleration response spectra from 246 stations within 120 km of the causative fault are statistically analyzed in this paper. The influence of distance and site conditions on long-period response spectrum is discussed, and the shapes of the amplification spectra are compared with the standard spectra specified in the seismic design code of China. Finally, suggestions for future revisions to the code are proposed.
基金Project supported by the National Natural Science Foundation of China (Grant No 60577035).
文摘The advantages of read-only storage is the predominance of optical recording relative to magnetic and other rewritable methods. Multilevel (ML) read-only technology has been a trend to improve the data capacity and transfer rate. Based on the principle and coding method of ML, this paper demonstrates some ML read-only recording methods, of which a new ML read-only recording is developed. This recording method integrates amplitude modulation achieved by the reaction mechanism of physics and chemistry of photoresist with the run-length-limited technology. The discs can be achieved using standard photoresist mastering and replication techniques with great compatibility to conventional binary read-only discs.
文摘Determining the upper boundary of the cobalt-rich crust distribution of a guyot is important for estimating the mineral resources available, however, it has also long been an unsolved question. Correlations between the sub-bottom structures, revealed by sub-bottom profiling, and crust distribution can be revealed for the first time by the synchronous application of sub-bottom profiling and deep-sea video recording. The lower boundary of the sediment corresponds with the upper boundary of the crust. By analysis of these two kinds of data, the lower boundary of the sediment can be determined; therefore, the upper boundary of the crust distribution can be deduced. According to this method of analysis, the upper boundary of water depth of crust distribution of a seamount in the western Pacific is about 1 560 m.
基金Supported by Research Project of Henan Science and Technology Foundation(0124110209,0211061900).
文摘A new kind of simple and flexible CO2 welding system was developed to carry out waveform control. The system consisted of IGBT inverter, PWM circuit and microprocessor unit ( MPU) , in which the output current of constant current (CC) power supply could be changed according to transient physical state, and the variable down slope rate control could be used to ensure a stable welding process. The welding experiment results proved the effectiveness of this control approach.
文摘The patch clamp recording technique in vivois a blind patch clamp recording methods to record the current of the spinal or cereral neurons of anaes:hesia ( or awake) animals. This technique can be used to study the synaptic function and plasticity in central nervous system in vivoin order to understand the physiological properties of the ion channels from an integrated point of view. The advantage of this technique have already presented itself in the study of the synaptic transmission and nervous network. Nowadays, in vivo patch whole-cell recording technique in combination with other techniques is becoming a common method in the research fields.
文摘Virtual memory management is always a very essential issue of the modern microprocessor design. A memory management unit (MMU) is designed to implement a virtual machine for user programs, and provides a management mechanism between the operating system and user programs. This paper analyzes the tradeoffs considered in the MMU design of Unity 11 CPU of Peking University, and introduces in detail the solution of pure hardware table walking with two level page table organization. The implementation takes care of required operations and high performances needed by modern operating systems and low costs needed by embedded systems. This solution has been silicon proven, and successfully porting the Linux 2.4.17 kernel, the XWindow system, GNOME and most application software onto the Unity platform.
基金Project supported by the National Natural Science Foundation of China (50671008,50871014,50831002)
文摘Cr/SmCo/Cr thin films with Sm concentration of 37.7 at.% were deposited on glass substrates by magnetron sputtering. Measurement of magnetic properties showed that the SmCo film possessed good magnetic anisotropy, a high coercivity of 3019 kA/m and low magnetic exchange coupling. Microstructure analysis showed that crystallized SmCo5 magnetic phase, non-magnetic SmCo2 phase and Sm2Co7 phase co-existed in the film. The non-magnetic SmCo2 phase might function as isolator of SmCo grains, leading to a decrease of magnetic exchange coupling. Moreover, a Cr2O3 oxide layer which could protect the SmCo layer from oxidation formed at the surface of the Cr cap layer.
文摘AIM: To record calcium and potassium currents in acutely isolated smooth muscle cells of mesenteric arterial branches in rats. METHODS: Smooth muscle cells were freshly isolated by collagenase digest and mechanical trituration with polished pipettes. Patch clamp technique in whole-cell mode was employed to record calcium and potassium currents. RESULTS: The procedure dissociated smooth muscle cells without impairing the electrophysiological characteristics of the cells. The voltage-gated Ca^2+ and potassium currents were successfully recorded using whole-cell patch clamp configuration. CONCLUSION: The method dissociates smooth muscle cells from rat mesenteric arterial branches. Voltage-gated channel currents can be recorded in this preparation.
基金the National Natural Science Foundation of China,No.30570232the Natural Science Foundation of Guangdong Province,No. 05005910Key Laboratory of Ecology and Environmental Science in Guangdong Higher Education
文摘BACKGROUND: Electrophysiological properties of the song nucleus have been revealed using conventional techniques, such as intracellular and extracellular recording. Research concerning the neuronal activation properties and regulations of the song system at the cellular and ion channel level may help reveal the neural mechanism of song learning. OBJECTIVE: To perform whole-cell recording of robust nucleus of the arcopallium (RA) neurons in brain slices from adult zebra finches (Taeniopygia guttata) and observe the action potential, sodium/potassium current and the spontaneous postsynaptic current of RA neurons. DESIGN, TIME AND SETTING: Self-controlled, neuroelectrophysiological experiment. The study was performed at the Neurophysiology Laboratory of South China Normal University from April to September 2008. MATERIALS: Flaming/Brown puller P-97 was purchased from Sutter Ins, USA; Axopatch 700B amplifier and Digidata 1332A converter were purchased from Axon Instrument, USA; pClamp software was provided by Axon Instrument, USA. METHODS: RA neurons were acutely isolated from 24 healthy male zebra finches. The action potential, voltage-gate sodium/potassium current and spontaneous postsynaptic current were recorded by whole-cell recording technology. Data were analyzed by pClamp software. MAIN OUTCOME MEASURES: The amplitude and frequency of the action potential, and the amplitude of the voltage-dependent and spontaneous postsynaptic currents, were measured. RESULTS: (1) Testing of action potential: Cells exhibited a stable current-voltage relationship following a series of hyperpolarization stepped currents, and an action potential was triggered by the spike threshold. All the recorded cells displayed repetitive firing following depolarizing current injection, with a frequency beyond 100 Hz. (2) Testing of voltage-gate currents: The inward and outward whole-cell currents were observed after a series of depolarizing voltage steps. The inward current disappeared following the application of tetrodotoxin and the outward current was significantly inhibited by application of 4-aminopyfidione and tetraethylammonium chloride. (3) Testing of spontaneous postsynaptic current: The majority of recorded cells exhibited an inward synaptic current when the membrane potential was maintained at -60 mV, with some cells exhibiting a robustly outward current when the membrane potential was maintained at -30 mV. Tetrodotoxin was unable to affect the spontaneous postsynaptic current. Following application of bicuculline [y-aminobutyric acid (A) receptor antagonist] and high concentration kynurenic acid (ionotropic glutamate receptor antagonist), the inward and outward currents were completely inhibited. CONCLUSION: Under these experimental conditions, the action potential, sodium/potassium current and spontaneous postsynaptic current were recorded successfully in RA neurons. This indicates that the cells preserved relatively intact synaptic connections and normal physiological activity, which is required for investigating ion channels. The inward and outward whole-cell currents were sodium and potassium currents, respectively. The postsynaptic y-aminobutyric acid (A) receptors and ionotropic glutamate receptors contributed to the spontaneous postsynaptic current.
基金supported by the China Capital Health Research and Development of Special (No. 2018-14111)the National Natural Science Foundation of China (grant No. 62004007 and No. 82027805)the China Postdoctoral Science Foundation Grant (No. 2021M700258)
文摘Microneedle array(MNA)electrodes are an effective solution to achieve high-quality surface biopotential recording without the coordination of conductive gel and are thus very suitable for long-term wearable applications.Existing schemes are limited by flexibility,biosafety,and manufacturing costs,which create large barriers for wider applications.Here,we present a novel flexible MNA electrode that can simultaneously achieve flexibility of the substrate to fit a curved body surface,robustness of microneedles to penetrate the skin without fracture,and a simplified process to allow mass production.The compatibility with wearable wireless systems and the short preparation time of the electrodes significantly improves the comfort and convenience of electrophysiological recording.The normalized electrode–skin contact impedance reaches 0.98 kΩcm^(2)at 1 kHz and 1.50 kΩcm^(2)at 10 Hz,a record low value compared to previous reports and approximately 1/250 of the standard electrodes.The morphology,biosafety,and electrical/mechanical properties are fully characterized,and wearable recordings with a high signal-to-noise ratio and low motion artifacts are realized.The first reported clinical study of microneedle electrodes for surface electrophysiological monitoring was conducted in tens of healthy and sleep-disordered subjects with 44 nights of recording(over 8 h per night),providing substantial evidence that the electrodes can be leveraged to substitute for clinical standard electrodes.
文摘The article discusses the possibility of further modernization of the standard microprocessor relay protection of AC overhead system feeders DPA-27.5-TNF, which is operated on the Trans-Baikal Railway by creating an additional automated system of unified templates necessary for the occurrence of “trainability” elements. The templates will be formed via a separate dedicated channel for transmission, processing and storage of the necessary information, not related to the operation of the terminal, with its subsequent visualization at the workplace of the duty personnel of traction substations, together with information from the “GID” software received via another dedicated wired channel. With the help of such a base of unified preset templates, in the future, it will be possible not only to identify the specific causes of each emergency shutdown but also to reduce their number by dynamically adjusting the existing presets of the standard operation algorithm.