期刊文献+
共找到11篇文章
< 1 >
每页显示 20 50 100
Determination of Lead in Lime-preserved Egg by Microwave Digestion and Flame Atomic Absorption Spectroscopy
1
作者 Mimi ZHANG 《Asian Agricultural Research》 2023年第7期51-53,共3页
[Objectives] To establish a method for determining the lead content in lime-preserved eggs, to provide a theoretical basis for the quality control of production enterprises and the sampling and testing of supervision ... [Objectives] To establish a method for determining the lead content in lime-preserved eggs, to provide a theoretical basis for the quality control of production enterprises and the sampling and testing of supervision departments. [Methods] The lead content in lime-preserved eggs was measured by the microwave digestion and flame atomic absorption spectroscopy. [Results] The method had a correlation coefficient of r2=0.998 in the injection concentration range of 0-4 mg/L. The detection limit of the method was 0.008 2 mg/kg. In the range of 0.2 to 1.0 mg/kg addition concentration, the recovery rate of the method was 92.5%-108.0%, and the relative standard deviation(RSD) was <5%. [Conclusions] This method is accurate and reliable, simple and efficient, and is suitable for the detection of lead in lime-preserved eggs. 展开更多
关键词 microwave digestion Flame atomic absorption spectroscopy Lime-preserved eggs LEAD
下载PDF
Application of closed-vessel microwave digestion method for the determination of multi-elements in environmental samples by sequential ICP-AES
2
作者 Xu Liqiang, Shen Wangxing and Zhu Jingfang Shanghai Institute of Metallurgy,Academia Sinica,Shanghai 200050,China 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 1989年第2期69-75,共7页
A closed-vessel microwave digestion method is described for the rapid dissolution of environmental samples such as foods, soils and sediments. Depending on the sample type, 0.1-0.2 g sample was decomposed with HNO3/H2... A closed-vessel microwave digestion method is described for the rapid dissolution of environmental samples such as foods, soils and sediments. Depending on the sample type, 0.1-0.2 g sample was decomposed with HNO3/H2O2 or HNO3 / H2O2/HF acid mixture in a PTFE digestion vessel by using microwave heating for 2-3 min at 500W of microwave power. The solution, or to which 0.5 g of boric acid was added, was diluted to 25-50 ml and directly determined by sequential ICP-AES. The accuracy of the procedure was validated by the analysis of six standard reference materials for 10 elements. Ail results were in a good agreements with the certified values. 展开更多
关键词 microwave digestion environmental sampl sequential ICP-AES elemental analysis.
下载PDF
Microwave digestion method in environmental analysis
3
作者 Zhang Yue (Wadsworth Centre ,New York State Department of Health School of Public Health,State University of New York at Albany.USA) Yu Yong, Hou Huiqi,Li Changlin(Environmental Science institute,Fudan University,Shanghai 200433, China) 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 1996年第4期407-413,共7页
This paper introduced the history,equipment and mechanism of the microwave digestion method. This paper studied the optimization parameter of digestion conditions, such as acid and acid combination, digestion time and... This paper introduced the history,equipment and mechanism of the microwave digestion method. This paper studied the optimization parameter of digestion conditions, such as acid and acid combination, digestion time and applied microwave power,particle size,and other factors.The analytical performance in environmental research and the modification of the microwave digestion method were also discussed. 展开更多
关键词 microwave digestion environmental analysis optimization parameter.
下载PDF
电感耦合等离子体质谱测定大气铅污染物
4
作者 郑永红 于水 +3 位作者 赵法 宋占军 刘丽萍 郭志英 《分析测试学报》 CAS CSCD 北大核心 2007年第z1期191-192,共2页
Inductively coupled plasma mass spectrometry(ICP-MS) was used to determine the concentration of Pb in atmospheric particulate samples,and the enrichment factor was calculated.The causes of the results were also discus... Inductively coupled plasma mass spectrometry(ICP-MS) was used to determine the concentration of Pb in atmospheric particulate samples,and the enrichment factor was calculated.The causes of the results were also discussed. 展开更多
关键词 Inductively coupled plasma mass spectrometry(ICP-MS) microwave digestion Enrichment factor
下载PDF
Microwave assisted digestion followed by ICP-MS for determination of trace metals in atmospheric and lake ecosystem 被引量:12
5
作者 Manan Ahmed Ying Hui Chin +1 位作者 Xinxin Guo Xing-Min Zhao 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2017年第5期1-10,共10页
The study of trace metals in the atmosphere and lake water is important due to their critical effects on humans, aquatic animals and the geochemical balance of ecosystems. The objective of this study was to investigat... The study of trace metals in the atmosphere and lake water is important due to their critical effects on humans, aquatic animals and the geochemical balance of ecosystems. The objective of this study was to investigate the concentration of trace metals in atmospheric and lake water samples during the rainy season (before and after precipitation) between November and December 2015. Typical methods of sample preparation for trace metal determination such as cloud point extraction, solid phase extraction and dispersive liquid- liquid micro-extraction are time-consuming and difficult to perform; therefore, there is a crucial need for development of more effective sample preparation procedure. A convection microwave assisted digestion procedure for extraction of trace metals was developed for use prior to inductively couple plasma-mass spectrometric determination. The result showed that metals like zinc (133.50-419.30 μg/m3) and aluminum (53.58-378.93 μg/m3) had higher concentrations in atmospheric samples as compared to lake samples before precipitation. On the other hand, the concentrations of zinc, aluminum, chromium and arsenic were significantly higher in lake samples after precipitation and lower in atmospheric samples. The relationship between physicochemical parameters (pH and turbidity) and heavy metal concentrations was investigated as well. Furthermore, enrichment factor analysis indicated that anthropogenic sources such as soil dust, biomass burning and fuel combustion influenced the metal concentrations in the atmosphere. 展开更多
关键词 Trace metals microwave digestion ICP-MS Atmospheric environment Lake ecosystem
原文传递
Direct Determination of Trace Impurities in High Purity Zinc Oxide by High Resolution Inductively Coupled Plasma Mass Spectrometry 被引量:2
6
作者 谢华林 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2006年第2期28-32,共5页
The determination of trace impurities in high purity zinc oxide by high resolution inductively coupled plasma mass spectrometry ( HR-ICP-MS ) was investigated. To overcome some poteutially problematic spectral iuter... The determination of trace impurities in high purity zinc oxide by high resolution inductively coupled plasma mass spectrometry ( HR-ICP-MS ) was investigated. To overcome some poteutially problematic spectral iuterference, measurements were acquired in both middle and high resolution modes. The matrix effects due to the presence of excess HCl and zinc were evaluated. The optimum conditions for the determination were tested and discussed. The standard addition method was employed for quantitative analysis. The detection limits ranged from 0.02μg/ g to 6 μg/ g depending on the elements. The experimental resalts for the determination of Na, Mg, Ca, Cr, Mn, Fe, Co, Ni, Cu, Mo, Cd, Sb and Pb in several high purity zinc oxide powders were presented. 展开更多
关键词 high purity zinc oxide trace impurities high resolution inductively coupled plasma mass spectrometry spectral interferences microwave digestion
下载PDF
Determination of Heavy Metals in Tobacco by ICP-MS and Analysis of Uncertainty 被引量:2
7
作者 Bo YANG Fengmin DUAN +1 位作者 Jinling DING Zhijuan BAO 《Asian Agricultural Research》 2016年第10期51-54,共4页
The research aims to set up the determination method of heavy metals in tobacco by ICP-MS and analyze its uncertainty. Microwave digest technique is used for decomposition of the tobacco samples. Bi,Sc,Ge and In are e... The research aims to set up the determination method of heavy metals in tobacco by ICP-MS and analyze its uncertainty. Microwave digest technique is used for decomposition of the tobacco samples. Bi,Sc,Ge and In are employed as internal standards to eliminate the interference of the matrix. A method is developed for simultaneous determination of Cr,Cu,As,Cd,Hg and Pb in tobacco from Yunnan Province by ICP-MS,and the measurement uncertainty is evaluated by metrological method. The test results indicate that in the content range of0- 1. 0 g / ml,the linearly dependent coefficient of six elements is 1. 0000,and the RSD achieves 1. 5%- 11%( n = 8). The elemental content in tobacco is as follows: Cr( 2. 92,0. 24) mg / kg,Cu( 3. 64,0. 24) mg / kg,As( 0. 467,0. 025) mg / kg,Cd( 3. 12,0. 15) mg / kg,Hg( 0. 035,0. 006) mg/kg,Pb( 4. 62,0. 36) mg/kg. The uncertainty of sample size,the constant volume of the sample solution can be neglected. It is concluded that the method is accurate,simple,sensitive and rapid. 展开更多
关键词 ICP-MS TOBACCO Heavy metals microwave digestion Uncertainty measurement
下载PDF
Analysis of trace elements in air particulate matters by non-suppressed ion chromatography
8
作者 Feng Yingsheng(Y.S.Fung) and Tan Weiming (W.M.Tam)Department of Chemistry,Hong Kong University,Hong Kong 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 1991年第1期29-39,共11页
The application of non-suppressed ion chromatography for monitoring of trace elements in air particulate matter was studied in the present investigation. The results indicate that the use of microwave acid digestion m... The application of non-suppressed ion chromatography for monitoring of trace elements in air particulate matter was studied in the present investigation. The results indicate that the use of microwave acid digestion method is superior in comparison with the conventional thermal acid digestion method as it leads to higher recovery, better reproducibility, lower volatility loss, better protection against environmental contamination and much less digestion time (5 minutes vs. 24 hours). The use of eluent as extractant is shown to reduce the water dip problem in the chro-matogram. The addition of chelating agent in the eluent coupled with UV detection is shown to provide satisfactory chromatographic separation and good sensitivity for the analysis of transition metals present in the air particulate matter. Using the U.S. National Bureau of Standards Reference Material 1648 Urban Particulate Matter as standard for checking, the analytical procedure is shown to give good recovery and reproducibility for the detection of the following cations and anions in air particulate matter: Fe2 Cu, Mn, Pb, Zn, Mg, Na, HN4+, Cl-, NO3- and SO42-. Field test was also performed to check the applicability of the method and the results obtained were discussed in the present paper. 展开更多
关键词 non-suppressed ion chromatography air particulate matter trace metals analysis anions analysis microwave digestion.
下载PDF
Trace Metal Pollution From Traffic in Denizli-Turkey During Dry Season
9
作者 UMIT DIVRIKLI DURALI MENDIL +2 位作者 MUSTAFA TUZEN MUSTAFA SOYLAK LATIF ELCI 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2006年第4期254-261,共8页
Objective To determine the metal contents of date palm (Pheonix dactylifera) samples in dry season from Denizli-Turkey for investigation of heavy metal-polluted traffic. Method The levels of iron, copper, zinc, lead... Objective To determine the metal contents of date palm (Pheonix dactylifera) samples in dry season from Denizli-Turkey for investigation of heavy metal-polluted traffic. Method The levels of iron, copper, zinc, lead, cadmium, nickel, chromium, and manganese ions in the leaves of thirty five date palm (Pheonix dactylifera) samples collected from various levels of traffic in the streets of Denizli-Turkey were determined by graphite furnace or flame atomic absorption spectrometry. The wet, dry, and microwave digestion procedures for the date palm (Pheonix dactylifera) leaves were compared. The accuracy of the digestion procedures was checked using a standard reference material (IAEA-336 Lichen, SRM). Results Microwave digestion procedure for the leaves was preferred because it was more proper with respect to both time and recovery than dry and wet digestion. The levels of the heavy metal ions investigated were the highest on the samples from high traffic level. Also correlations between metal levels and traffic volume for all the metals were investigated. Conclusion In the light of our findings, the date palm (Phoenix dactylifera) leaves are suitable as a biomonitor for atmospheric heavy metal-polluted traffic. Significant correlations can be obtained between traffic levels and heavy metal concentrations. 展开更多
关键词 Phoenix dactylifera microwave digestion Atomic absorption spectrometry Denizli TURKEY
下载PDF
Determination of Harmful Elements and Analysis of Pollution Level in Lysimachia christinae
10
作者 Li WAN Ya GUO +2 位作者 Qin XIANG Qi XIAO Wenwu YANG 《Medicinal Plant》 CAS 2022年第5期31-33,共3页
[Objectives]To detect content of Pb,Cd,Hg,As,Cu,Zn,and Cr in Lysimachia christinae,and to analyze the pollution level.[Methods]Seven kinds of elements in L.christinae were determined by Inductively coupled plasma mass... [Objectives]To detect content of Pb,Cd,Hg,As,Cu,Zn,and Cr in Lysimachia christinae,and to analyze the pollution level.[Methods]Seven kinds of elements in L.christinae were determined by Inductively coupled plasma mass spectrometry and analyzed by single index and comprehensive index.[Results]The seven heavy metal elements showed good linearity in their respective concentration ranges.The recoveries of the samples were 84.5%-109.5%,and the RSD values were 2.30%-5.10%.Comparing the measured results of heavy metal elements with the limit values stipulated in the 2020 edition of the Chinese Pharmacopoeia and other standards,the Cr element in 19 batches of samples exceeded the standard,and the Zn element in 7 batches of samples exceeded the standard.The exceeding rates were 100.0%and 36.8%,respectively;the content of other heavy metal elements did not exceed the standard.The order of individual index from large to small was Cr,Zn,Cd,Hg,Cu,As,and Pb,and the average comprehensive pollution level was mild pollution and above.[Conclusions]L.christinae was mainly polluted by Cr,followed by Zn;this study can provide basic data for drafting of the limit standard for heavy metal elements in L.christinae. 展开更多
关键词 Lysimachia christinae Heavy metals elements Harmful elements ICP-MS microwave digestion Single factor index method Comprehensive index method Pollution level analysis Quality control
下载PDF
Optimization of microwave pretreatment of lignocellulosic waste for enhancing methane production: Hyacinth as an example 被引量:1
11
作者 Bai-Hang Zhao Jie Chen +3 位作者 Han-Qing Yu Zhen-Hu Hu Zheng-Bo Yue Jun Li 《Frontiers of Environmental Science & Engineering》 SCIE EI CAS CSCD 2017年第6期161-169,共9页
The effect of microwave pretreatment on the anaerobic degradation of hyacinth was investigated using response surface methodology (RSM). The components oflignin and the other constituents of hyacinth were altered by... The effect of microwave pretreatment on the anaerobic degradation of hyacinth was investigated using response surface methodology (RSM). The components oflignin and the other constituents of hyacinth were altered by microwave pretreatment. Comparison of the near-infrared spectra of hyacinth pretreated by microwave irradiation and water-heating pretreatment revealed that no new compounds were generated during hyacinth pretreatment by microwave irradiation. Atomic force microscopy observations indicated that the physical structures of hyacinth were disrupted by microwave pretreatment. The yield of methane per gram of the microwave-irradiated substrate increased by 38.3% as compared to that of the substrate pretreated via water-heating. A maximum methane yield of 221 mL·g-sub^-1 was obtained under the optimum pretreatment conditions (substrate concentration (pSC) = 20.1 g·L^-1 and pretreatment time (PT) = 14.6 min) using RSM analysis. A maximum methane production rate of 0.76 mL·h^-1· g-sub^-1 was obtained by applying PSC = 9.5 g·L^-1 and PT= 11 min. Interactive item coefficient analysis showed that methane production was dependent on the PSC and PT, separately, whereas the interactive effect of the PSC and PT on methane production was not significant. The same trend was also observed for the methane production rate. 展开更多
关键词 microwave pretreatment Response surface methodology Methane production Hyacinth Anaerobic digestion
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部