The Microwave-Induced Plasma (MIP) has received considerable attention during the past decade since theintroduction of the Becnakker Cavity. It has been commonly used as an atomization cell for atomic emission spectro...The Microwave-Induced Plasma (MIP) has received considerable attention during the past decade since theintroduction of the Becnakker Cavity. It has been commonly used as an atomization cell for atomic emission spectrometry (AES) and atomic absorption spectrometry (AAS), and a great success was achieved for both techniques. More展开更多
In this paper, a new MPT(microwave plasma torch) device has been used as a atomizer for atomic fluorescence spectrometry. Spme elements, such as Zn, Cd, Hg, Pb, As, Co, Mg, Cu, Ag, Mn, Fe have been investigated in det...In this paper, a new MPT(microwave plasma torch) device has been used as a atomizer for atomic fluorescence spectrometry. Spme elements, such as Zn, Cd, Hg, Pb, As, Co, Mg, Cu, Ag, Mn, Fe have been investigated in detail.展开更多
考察了消解方式、消解酸体系、升温时间和目标温度对样品消解效果的影响,提出了微波消解-电感耦合等离子体原子发射光谱法(ICP-AES)同时测定钛及钛合金中Fe、Si、Mn、Mo、B、Al、Sn、Cr、V、Zr、Mg、Nb、Pd、Ni、Ta、W、Nd、Ru、Cu等19...考察了消解方式、消解酸体系、升温时间和目标温度对样品消解效果的影响,提出了微波消解-电感耦合等离子体原子发射光谱法(ICP-AES)同时测定钛及钛合金中Fe、Si、Mn、Mo、B、Al、Sn、Cr、V、Zr、Mg、Nb、Pd、Ni、Ta、W、Nd、Ru、Cu等19种元素含量的方法。取0.1000 g钛及钛合金样品置于聚四氟乙烯消解罐中,再加入8.0 mL 33%(体积分数)盐酸溶液、3.0 mL 25%(体积分数)氢氟酸溶液、1.0 mL 50%(体积分数)硝酸溶液和0.5 mL高氯酸,将其置于微波消解仪于最高消解温度120℃下保持10 min,冷却至室温,用水将消解液定容至50 mL,采用ICP-AES测定质量分数不大于1.0%的元素,将样品溶液稀释10倍,同法测定质量分数大于1.0%的元素。结果表明,19种元素的质量浓度在一定范围内与对应的响应强度呈线性关系,检出限(3s)为0.006~0.033 mg·L^(-1)。对4种钛合金标准样品和3种钛合金实际样品进行分析,并与标准方法GB/T 4698系列的测定结果进行对比,结果显示本方法的测定值与认定值基本一致。以两种钛合金标准样品和两种钛合金实际样品为研究对象进行精密度试验,每个样品平行测定5次,测定值的相对标准偏差均小于4.0%。展开更多
目的:建立一种简便、高效、灵敏的硝酸-盐酸混合酸-石墨消解仪消解-氢化物发生原子荧光光谱法测定猪肝样品中(干粉)全硒含量。方法:使用HCl和HNO+3对猪肝样品(干粉)进行消解,采用原子荧光光度计测定猪肝中全硒含量。结果:硒工作曲线的...目的:建立一种简便、高效、灵敏的硝酸-盐酸混合酸-石墨消解仪消解-氢化物发生原子荧光光谱法测定猪肝样品中(干粉)全硒含量。方法:使用HCl和HNO+3对猪肝样品(干粉)进行消解,采用原子荧光光度计测定猪肝中全硒含量。结果:硒工作曲线的线性范围是2~20μg·L^(-1),相关系数为0.999 7;检出限和定量限分别是0.029μg·L^(-1)和0.098μg·L^(-1),不同浓度下的加标回收率在91.2%~111.4%,日内精密度为1.2%,日间精密度2.1%。同时对石墨消解仪消解样品条件进行了单因素条件优化,最优化条件为消解还原溶剂4 mL HCl和1 mL HNO+3,最佳料液比1/25(0.200 g/5 mL),消解温度采用离心管最大耐受温度120℃,消解时间3 h。结论:本研究为猪肝中全硒含量的测定提供了一种简单、快捷、高效、环保的方法。展开更多
文摘The Microwave-Induced Plasma (MIP) has received considerable attention during the past decade since theintroduction of the Becnakker Cavity. It has been commonly used as an atomization cell for atomic emission spectrometry (AES) and atomic absorption spectrometry (AAS), and a great success was achieved for both techniques. More
文摘In this paper, a new MPT(microwave plasma torch) device has been used as a atomizer for atomic fluorescence spectrometry. Spme elements, such as Zn, Cd, Hg, Pb, As, Co, Mg, Cu, Ag, Mn, Fe have been investigated in detail.
文摘考察了消解方式、消解酸体系、升温时间和目标温度对样品消解效果的影响,提出了微波消解-电感耦合等离子体原子发射光谱法(ICP-AES)同时测定钛及钛合金中Fe、Si、Mn、Mo、B、Al、Sn、Cr、V、Zr、Mg、Nb、Pd、Ni、Ta、W、Nd、Ru、Cu等19种元素含量的方法。取0.1000 g钛及钛合金样品置于聚四氟乙烯消解罐中,再加入8.0 mL 33%(体积分数)盐酸溶液、3.0 mL 25%(体积分数)氢氟酸溶液、1.0 mL 50%(体积分数)硝酸溶液和0.5 mL高氯酸,将其置于微波消解仪于最高消解温度120℃下保持10 min,冷却至室温,用水将消解液定容至50 mL,采用ICP-AES测定质量分数不大于1.0%的元素,将样品溶液稀释10倍,同法测定质量分数大于1.0%的元素。结果表明,19种元素的质量浓度在一定范围内与对应的响应强度呈线性关系,检出限(3s)为0.006~0.033 mg·L^(-1)。对4种钛合金标准样品和3种钛合金实际样品进行分析,并与标准方法GB/T 4698系列的测定结果进行对比,结果显示本方法的测定值与认定值基本一致。以两种钛合金标准样品和两种钛合金实际样品为研究对象进行精密度试验,每个样品平行测定5次,测定值的相对标准偏差均小于4.0%。
文摘目的:建立一种简便、高效、灵敏的硝酸-盐酸混合酸-石墨消解仪消解-氢化物发生原子荧光光谱法测定猪肝样品中(干粉)全硒含量。方法:使用HCl和HNO+3对猪肝样品(干粉)进行消解,采用原子荧光光度计测定猪肝中全硒含量。结果:硒工作曲线的线性范围是2~20μg·L^(-1),相关系数为0.999 7;检出限和定量限分别是0.029μg·L^(-1)和0.098μg·L^(-1),不同浓度下的加标回收率在91.2%~111.4%,日内精密度为1.2%,日间精密度2.1%。同时对石墨消解仪消解样品条件进行了单因素条件优化,最优化条件为消解还原溶剂4 mL HCl和1 mL HNO+3,最佳料液比1/25(0.200 g/5 mL),消解温度采用离心管最大耐受温度120℃,消解时间3 h。结论:本研究为猪肝中全硒含量的测定提供了一种简单、快捷、高效、环保的方法。