Previously, we presented several empirical equations using the cosmic microwave background (CMB) temperature. Next, we propose an empirical equation for the fine-structure constant. Considering the compatibility among...Previously, we presented several empirical equations using the cosmic microwave background (CMB) temperature. Next, we propose an empirical equation for the fine-structure constant. Considering the compatibility among these empirical equations, the CMB temperature (Tc) and gravitational constant (G) were calculated to be 2.726312 K and 6.673778 × 10−11 m3∙kg−1∙s−2, respectively. Every equation can be explained numerically in terms of the Compton length of an electron (λe), the Compton length of a proton (λp) and α. Furthermore, every equation can also be explained in terms of the Avogadro number and the number of electrons at 1 C. We show that every equation can be described in terms of the Planck constant. Then, the ratio of the gravitational force to the electric force can be uniquely determined with the assumption of minimum mass. In this report, we describe the algorithms used to explain these equations in detail. Thus, there are no dimension mismatch problems.展开更多
In this paper, two microwave irradiation methods:(i) liquid-phase microwave irradiation(MWI) reduction of graphite oxide suspension dissolved in de-ionized water and N, N-dimethylformamide, respectively, and(ii...In this paper, two microwave irradiation methods:(i) liquid-phase microwave irradiation(MWI) reduction of graphite oxide suspension dissolved in de-ionized water and N, N-dimethylformamide, respectively, and(ii) solid-phase MWI reduction of graphite oxide powder have been successfully carried out to reduce graphite oxide. The reduced graphene oxide products are thoroughly characterized by scanning electron microscopy, atomic force microscopy, X-ray photoelectron spectroscopy, Fourier transform infrared spectral analysis, Raman spectroscopy, UV-Vis absorption spectral analysis,and four-point probe conductivity measurements. The results show that both methods can efficiently remove the oxygencontaining functional groups attached to the graphite layers, though the solid-phase MWI reduction method can obtain far more efficiently a higher quality-reduced graphene oxide with fewer defects. The I(D)/I(G) ratio of the solid-phase MWI sample is as low as 0.46, which is only half of that of the liquid-phase MWI samples. The electrical conductivity of the reduced graphene oxide by the solid method reaches 747.9 S/m, which is about 25 times higher than that made by the liquid-phase method.展开更多
To improve drying uniformity and anthocyanin content of the raspberry puree dried in a continuous microwave dryer,the effects of process parameters(microwave intensity,air velocity,and drying time)on evaluation indexe...To improve drying uniformity and anthocyanin content of the raspberry puree dried in a continuous microwave dryer,the effects of process parameters(microwave intensity,air velocity,and drying time)on evaluation indexes(average temperature,average moisture content,average retention rate of the total anthocyanin content,temperature contrast value,and moisture dispersion value)were investigated via the response surface method(RSM)and the artificial neural network(ANN)with genetic algorithm(GA).The results showed that the microwave intensity and drying time dominated the changes of evaluation indexes.Overall,the ANN model was superior to the RSM model with better estimation ability,and higher drying uniformity and anthocyanin retention rate were achieved for the ANN-GA model compared with RSM.The optimal parameters were microwave intensity of 5.53 W•g^(-1),air velocity of 1.22 m·s^(-1),and drying time of 5.85 min.This study might provide guidance for process optimization of microwave drying berry fruits.展开更多
The easy-plane anisotropy of the Y_(2)Co_(17)rare earth soft magnetic alloy has high saturation magnetization and operating frequency,and good impedance matching.Therefore,it is expected to become a kind of high-perfo...The easy-plane anisotropy of the Y_(2)Co_(17)rare earth soft magnetic alloy has high saturation magnetization and operating frequency,and good impedance matching.Therefore,it is expected to become a kind of high-performance microwave absorbing material.In this paper,Y_(2)Co_(17)alloy was prepared by a reduction-diffusion method,and its micropowder was prepared as polyurethane(PU)based composite absorbing materials(Y_(2)Co_(17)/PU composites).The microwave properties of composites with different volume fractions were calculated.The composites showed outstanding absorption characteristics in the range of 20-30 vol%,and the minimum reflection loss(RL)was less than-50 d B.When the volume fraction was25%,the effective absorption bandwidth could cover the X-band at a thickness of 1.5 mm,and the Ku-band at a thickness of1.08 mm.The absorption mechanism was analyzed by the interface reflection model.The RL absorption peak bandwidth mechanism was discussed by using the amplitude relation and calculating the effective absorption bandwidth at different thicknesses.The effective absorption bandwidth values were in good agreement with the theoretical expectation.展开更多
The new catalytic kinetic spectrophotometric method for Au(III) determination was developed and validated. It was based on the catalytic effect of gold on the oxidation of sudan red III by ammonium peroxodisulfate ...The new catalytic kinetic spectrophotometric method for Au(III) determination was developed and validated. It was based on the catalytic effect of gold on the oxidation of sudan red III by ammonium peroxodisulfate ((NH4)2S2O8) with nitrilo triacetic acid as an activator in microemulsion and H2SO4 medium. Under optimum conditions, there was the linearity of the calibration curve in the concentration range from 0 to 20 μg/L Au(Ⅲ) at 520 nm. The relative standard deviation was 3.0% with a correlation coefficient of 0.9986. The detection limit achieved was 9.75 × 10^-5 μg/mL. A new method using a column packed with sulfhydryl dextrose gel (SDG) as a solid-phase extractant has been developed for the preconcentration and separation of Au(Ⅲ) ions. The method has been applied to the determination of trace gold with satisfactory results.展开更多
A trust region method is proposed to solve the problem of microwave tomography,which is very difficult to be solved for its ill-posedness and nonlinearity. Compared with the Levenberg-Marquardt method, this method int...A trust region method is proposed to solve the problem of microwave tomography,which is very difficult to be solved for its ill-posedness and nonlinearity. Compared with the Levenberg-Marquardt method, this method introduces more a priori knowledge and might obtain better results, though the two methods are equal in some cases.展开更多
A passive and multi-channel microwave sounder onboard the Chang'e-2 orbiter has successfully acquired microwave observations of the lunar surface and subsurface structure. Compared with the Chang'e-1 orbiter, the Ch...A passive and multi-channel microwave sounder onboard the Chang'e-2 orbiter has successfully acquired microwave observations of the lunar surface and subsurface structure. Compared with the Chang'e-1 orbiter, the Chang'e-2 orbiter obtained more accurate and comprehensive microwave brightness temperature data, which are helpful for further research. Since there is a close relationship between mi- crowave brightness temperature data and some related properties of the lunar regolith, such as the thickness, temperature and dielectric constant, precise and high resolution brightness temperature data are necessary for such research. However, through the detection mechanism of the microwave sounder, the brightness temperature data ac- quired from the microwave sounder are weighted by the antenna radiation pattern, so the data are the convolution of the antenna radiation pattern with the lunar brightness temperature. In order to obtain the real lunar brightness temperature, a deconvolution method is needed. The aim of this paper is to solve the problem associated with per- forming deconvolution of the lunar brightness temperature. In this study, we introduce the maximum entropy method (MEM) to process the brightness temperature data and achieve excellent results. The paper mainly includes the following aspects: first, we introduce the principle of the MEM; second, through a series of simulations, the MEM has been verified as an efficient deconvolution method; and third, the MEM is used to process the Chang'e-2 microwave data and the results are significant.展开更多
This work presents an optimal design method of antenna aperture illumination for microwave power transmission with an annular collection area.The objective is to maximize the ratio of the power radiated on the annular...This work presents an optimal design method of antenna aperture illumination for microwave power transmission with an annular collection area.The objective is to maximize the ratio of the power radiated on the annular collection area to the total transmitted power.By formulating the aperture amplitude distribution through a summation of a special set of series,the optimal design problem can be reduced to finding the maximum ratio of two real quadratic forms.Based on the theory of matrices,the solution to the formulated optimization problem is to determine the largest characteristic value and its associated characteristic vector.To meet security requirements,the peak radiation levels outside the receiving area are considered to be extra constraints.A hybrid grey wolf optimizer and Nelder–Mead simplex method is developed to deal with this constrained optimization problem.In order to demonstrate the effectiveness of the proposed method,numerical experiments on continuous apertures are conducted;then,discrete arrays of isotropic elements are employed to validate the correctness of the optimized results.Finally,patch arrays are adopted to further verify the validity of the proposed method.展开更多
Fe-based carbon materials are widely considered promising to replace Pt/C as next-generation electrocatalysts towards oxygen reduction reaction (ORR). However, the preparation of Fe-based carbon materials is still car...Fe-based carbon materials are widely considered promising to replace Pt/C as next-generation electrocatalysts towards oxygen reduction reaction (ORR). However, the preparation of Fe-based carbon materials is still carried out by conventional heating method (CHM). Herein, a novel microwave-assisted carbon bath method (MW-CBM) was proposed, which only took 35 min to synthesize Fe/Fe3C nanoparticles encapsulated in N-doped carbon layers derived from Prussian blue (PB). The catalyst contained large specific surface area and mesoporous structure, abundant Fe-Nx and C–N active sites, unique core-shell structure. Due to the synergistic effects of these features, the as-prepared Fe/Fe3C@NC-2 displayed outstanding ORR activity with onset potential of 0.98 VRHE and halfwave potential of 0.87 VRHE, which were more positive than 20 wt.% Pt/C (0.93 VRHE and 0.82 VRHE). Besides, Fe/Fe3C@NC-2 gave a better stability and methanol tolerance than Pt/C towards ORR in alkaline media, too.展开更多
This paper investigates a microwave heating method for the determination of chemical oxygen demand (COD) in seawater. The influences of microwave-power, heating time and standard substances on the results are studied....This paper investigates a microwave heating method for the determination of chemical oxygen demand (COD) in seawater. The influences of microwave-power, heating time and standard substances on the results are studied. Using the proposed method, we analyzed the glucose standard solution, the coefficient of variation being less than 2%. Compared with the traditional electric stove heating method, the results of F-test and T-test showed that there was no significant difference between the two methods, but the microwave method had slightly higher precision and reproducibility than the electric stove method. With the microwave heating method, several seawater samples from Jiaozhou Bay and the South Yellow Sea were also analyzed. The recovery was between 97.5% and 104.3%. This new method has the advantages of shortening the heating time, improving the working efficiency and having simple operation and therefore can be used to analyze the COD in seawater.展开更多
A Pt/graphene‐TiO2catalyst was prepared by a microwave‐assisted solvothermal method and was characterized by X‐ray diffraction,scanning electron microscopy,transmission electron microscopy,cyclic voltammetry,and li...A Pt/graphene‐TiO2catalyst was prepared by a microwave‐assisted solvothermal method and was characterized by X‐ray diffraction,scanning electron microscopy,transmission electron microscopy,cyclic voltammetry,and linear sweep voltammetry.The cubic TiO2particles were approximately60nm in size and were distributed on the graphene sheets.The Pt nanoparticles were uniformly distributed between the TiO2particles and the graphene sheet.The catalyst exhibited a significant improvement in activity and stability towards the oxygen reduction reaction compared with Pt/C,which resulted from the high electronic conductivity of graphene and strong metal‐support interactions.展开更多
As concepts closely related to microwave absorption properties,impedance matching and phase matching were rarely combined with material parameters to regulate properties and explore related mechanisms.In this work,red...As concepts closely related to microwave absorption properties,impedance matching and phase matching were rarely combined with material parameters to regulate properties and explore related mechanisms.In this work,reduction–diffusion method was innovatively applied to synthesize rare earth alloy Y_(2)Fe_(17).In order to regulate the electromagnetic parameters of absorbers,the Y_(2)Fe_(17)N_(3-δ)particles were coated with silica(Y_(2)Fe_(17)N_(3-δ)@SiO_(2))and absorbers with different volume fractions were prepared.The relationship between impedance matching,matching thickness,and the strongest reflection loss peak(RLmin)was presented obviously.Compared to the microwave absorption properties of Y_(2)Fe_(17)N_(3-δ)/PU absorber,Y_(2)Fe_(17)N_(3-δ)@SiO_(2)/PU absorbers are more conducive to the realization of microwave absorption material standards which are thin thickness,light weight,strong absorbing intensity,and broad bandwidth.Based on microwave frequency bands,the microwave absorption properties of the absorbers were analyzed and the related parameters were listed.As an important parameter related to perfect matching,reflection factor(√ε_(r)/μ_(r))was discussed combined with microwave amplitude attenuation.According to the origin and mathematical model of bandwidth,the formula of EAB(RL<-10 dB)was derived and simplified.The calculated bandwidths agreed well with experimental results.展开更多
A new approach based on resonance technique and modified boundary ele-ment method is presented to calculate the impedance parameter matrix of a microwaveN-port network of waveguide structure.A two port network is take...A new approach based on resonance technique and modified boundary ele-ment method is presented to calculate the impedance parameter matrix of a microwaveN-port network of waveguide structure.A two port network is taken as a numerical ex-ample and the results show that the approach occupys the advantages of high accuracyand less computation effort.展开更多
Decoction of Kampo medicines plays an important role in clinical practice, especially in individualized treatment, while the inconvenience and a long time requirement of the decocting process are impediments to its wi...Decoction of Kampo medicines plays an important role in clinical practice, especially in individualized treatment, while the inconvenience and a long time requirement of the decocting process are impediments to its widespread use in Japan. In this study, we improved the decocting method by using a microwave oven such as those found in most kitchens. To validate the feasibility and safety of this new method, we decocted kakkonto, which is the most widely used formula in clinical treatment in Japan, and keishikabushito, which contains toxic components using a microwave oven. Regarding the contents of 8 characteristic components in the kakkonto decoction and the contents of 6 toxic components in the keishikabushito decoction as indices, and with the extraction and detoxification effects equal to those of the conventional decocting method as targets, we optimized the decocting conditions with Response Surface Methods. With this new method, it took 35 min to obtain almost the same extraction effect for kakkonto as with the conventional decocting method, which takes 40 min;meanwhile, it took only 45 min to detoxify keishikabushito, which takes 60 min using the conventional decocting method. Decocting Kampo medicines with a microwave oven is feasible and as safe as the conventional decocting method. It is a convenient, safe, time-saving method, and may be applied widely in clinical practice. This innovation should allow more patients to benefit from decoction and the individualized treatment it offers.展开更多
In this peper we have synthesized powder crystal form (Y,Gd) BO3:Eu(3+)Phosphors by microwave heating method. ItS structure belongs to hexagonal system with lattice parameters a=0.3796,c=0. 8835. Its excitation spetra...In this peper we have synthesized powder crystal form (Y,Gd) BO3:Eu(3+)Phosphors by microwave heating method. ItS structure belongs to hexagonal system with lattice parameters a=0.3796,c=0. 8835. Its excitation spetra peaks at 239.0nm and 240. 0nm monitored at the emission of 589nm and 612nm respectively, the half peak width is 40nm. Under 240nm excitation the phosphors show a strons oranse-red luminescence, the fluorescent intensity ratio for I589/I612 is 1.9/1展开更多
This article examined in detail microwave radiometer functioning algorithm with synchronously using of the two types of pulse modulation: amplitude pulse modulation and pulse-width modulation. This allows a zero-radio...This article examined in detail microwave radiometer functioning algorithm with synchronously using of the two types of pulse modulation: amplitude pulse modulation and pulse-width modulation. This allows a zero-radiometer measurement method to realize when the fluctuation effect of the receiver gain and the influence of its own noise changes are minimized. A zero balance automatically maintains in radiometer. The antenna signal is indirectly determined through the signal duration that controls the pulse-width modulation. An analytical expression of the fluctuation sensitivity was obtained in a general form. From its analysis gain in sensitivity, conditions were defined by the optimizing of the radiometer input knot’s construction. Three modifications of the radiometer input knot were researched. Fluctuation sensitivity at different measurement range was determined for modification of the radiometer input knot.展开更多
Using a low power microwave generator and a surfatron discharge cavity, Ti3O5 was synthesized via the hydrogenation of TiO2 in surface wave induced microwave plasma. Besides, the chemical behavior of hydrogen in the p...Using a low power microwave generator and a surfatron discharge cavity, Ti3O5 was synthesized via the hydrogenation of TiO2 in surface wave induced microwave plasma. Besides, the chemical behavior of hydrogen in the plasma and its influence on the formation of Ti3O5 were preliminarily studied.展开更多
Objective: To investigate the electromagnetic field and specific absorptionrate (SAR) distribution of different structure applicators with different depths for treating bonetumors using microwave hyperthermia. Methods...Objective: To investigate the electromagnetic field and specific absorptionrate (SAR) distribution of different structure applicators with different depths for treating bonetumors using microwave hyperthermia. Methods: The finite element method (FEM) was used to calculate,electromagnetic field and SAR distribution. Two different structure applicators were simulated. Theone is simple coaxial antenna, which has been successfully used in clinic treating bone tumors inTangdu hospital of the Forth Military Medical University several years. It was formed by a coaxialcable peeled off the out copper at end. The other applicator was coaxial- slot antenna, which waswidely used in microwave hyperthermia. The applicator inserted into the cylindrical bone withdifferent depths, and worked at the frequency of 2 450 MHz. Results: The electric field and SARgenerated by the simple coaxial applicator were mainly concentrated out the tissues, and were notuniform in the tissues, while the coaxial- slot applicator well transmits the electric field and SARinto the tissues, and can easily treat different position by adjusting the slat position.Conclusion: The results calculated by EFM, were well accordant with the experimental and clinicalresulls, and will be important for improving the clinical effects of microwave hyperthermia.展开更多
A novel synthesis method of carbon-coated LiNil/3Mnl/3COl/302 cathode material for lithium-ion battery was reported. The carbon coating was produced from a precursor, glucose, by microwave-pyrolysis method. The prepar...A novel synthesis method of carbon-coated LiNil/3Mnl/3COl/302 cathode material for lithium-ion battery was reported. The carbon coating was produced from a precursor, glucose, by microwave-pyrolysis method. The prepared powders were characterized by scanning electron microscopy (SEM), X-ray diffraction (XRD), X-ray fluorescence (XRF) and charge/discharge tests. XRD results indicate that the carbon coating does not change the phase structure of LiNil/3Mnl/3C01/302 material. SEM results show that the surface of spherical carbon-coated material becomes rough. Electrochemical performance results show that the carbon coating can improve the cycling performance of LiNii/3Mnl/3C01/302. The specific discharge capacity retention of the carbon-coated LiNi1/3Mnt/3Col/30z reached 85.0%-96.0% at the 50th cycle at 0.2C rate, and the specific discharge capacity retention is improved at a high rate.展开更多
文摘Previously, we presented several empirical equations using the cosmic microwave background (CMB) temperature. Next, we propose an empirical equation for the fine-structure constant. Considering the compatibility among these empirical equations, the CMB temperature (Tc) and gravitational constant (G) were calculated to be 2.726312 K and 6.673778 × 10−11 m3∙kg−1∙s−2, respectively. Every equation can be explained numerically in terms of the Compton length of an electron (λe), the Compton length of a proton (λp) and α. Furthermore, every equation can also be explained in terms of the Avogadro number and the number of electrons at 1 C. We show that every equation can be described in terms of the Planck constant. Then, the ratio of the gravitational force to the electric force can be uniquely determined with the assumption of minimum mass. In this report, we describe the algorithms used to explain these equations in detail. Thus, there are no dimension mismatch problems.
基金Project supported by the National Natural Science Foundation of China(Grant No.61176090)the National Science and Technology Project 02,China(Grant No.2013ZX02303-004)
文摘In this paper, two microwave irradiation methods:(i) liquid-phase microwave irradiation(MWI) reduction of graphite oxide suspension dissolved in de-ionized water and N, N-dimethylformamide, respectively, and(ii) solid-phase MWI reduction of graphite oxide powder have been successfully carried out to reduce graphite oxide. The reduced graphene oxide products are thoroughly characterized by scanning electron microscopy, atomic force microscopy, X-ray photoelectron spectroscopy, Fourier transform infrared spectral analysis, Raman spectroscopy, UV-Vis absorption spectral analysis,and four-point probe conductivity measurements. The results show that both methods can efficiently remove the oxygencontaining functional groups attached to the graphite layers, though the solid-phase MWI reduction method can obtain far more efficiently a higher quality-reduced graphene oxide with fewer defects. The I(D)/I(G) ratio of the solid-phase MWI sample is as low as 0.46, which is only half of that of the liquid-phase MWI samples. The electrical conductivity of the reduced graphene oxide by the solid method reaches 747.9 S/m, which is about 25 times higher than that made by the liquid-phase method.
基金Supported by the National Natural Science Foundation of China(32072352)。
文摘To improve drying uniformity and anthocyanin content of the raspberry puree dried in a continuous microwave dryer,the effects of process parameters(microwave intensity,air velocity,and drying time)on evaluation indexes(average temperature,average moisture content,average retention rate of the total anthocyanin content,temperature contrast value,and moisture dispersion value)were investigated via the response surface method(RSM)and the artificial neural network(ANN)with genetic algorithm(GA).The results showed that the microwave intensity and drying time dominated the changes of evaluation indexes.Overall,the ANN model was superior to the RSM model with better estimation ability,and higher drying uniformity and anthocyanin retention rate were achieved for the ANN-GA model compared with RSM.The optimal parameters were microwave intensity of 5.53 W•g^(-1),air velocity of 1.22 m·s^(-1),and drying time of 5.85 min.This study might provide guidance for process optimization of microwave drying berry fruits.
基金Project supported by the National Key R&D Program of China(Grant No.2021YFB3501302)the National Natural Science Foundation of China(Grant No.51731001)supported by the State Key Laboratory of Baiyunobo Rare Earth Resource Researches and Comprehensive Utilization’s key of research and development projects。
文摘The easy-plane anisotropy of the Y_(2)Co_(17)rare earth soft magnetic alloy has high saturation magnetization and operating frequency,and good impedance matching.Therefore,it is expected to become a kind of high-performance microwave absorbing material.In this paper,Y_(2)Co_(17)alloy was prepared by a reduction-diffusion method,and its micropowder was prepared as polyurethane(PU)based composite absorbing materials(Y_(2)Co_(17)/PU composites).The microwave properties of composites with different volume fractions were calculated.The composites showed outstanding absorption characteristics in the range of 20-30 vol%,and the minimum reflection loss(RL)was less than-50 d B.When the volume fraction was25%,the effective absorption bandwidth could cover the X-band at a thickness of 1.5 mm,and the Ku-band at a thickness of1.08 mm.The absorption mechanism was analyzed by the interface reflection model.The RL absorption peak bandwidth mechanism was discussed by using the amplitude relation and calculating the effective absorption bandwidth at different thicknesses.The effective absorption bandwidth values were in good agreement with the theoretical expectation.
文摘The new catalytic kinetic spectrophotometric method for Au(III) determination was developed and validated. It was based on the catalytic effect of gold on the oxidation of sudan red III by ammonium peroxodisulfate ((NH4)2S2O8) with nitrilo triacetic acid as an activator in microemulsion and H2SO4 medium. Under optimum conditions, there was the linearity of the calibration curve in the concentration range from 0 to 20 μg/L Au(Ⅲ) at 520 nm. The relative standard deviation was 3.0% with a correlation coefficient of 0.9986. The detection limit achieved was 9.75 × 10^-5 μg/mL. A new method using a column packed with sulfhydryl dextrose gel (SDG) as a solid-phase extractant has been developed for the preconcentration and separation of Au(Ⅲ) ions. The method has been applied to the determination of trace gold with satisfactory results.
文摘A trust region method is proposed to solve the problem of microwave tomography,which is very difficult to be solved for its ill-posedness and nonlinearity. Compared with the Levenberg-Marquardt method, this method introduces more a priori knowledge and might obtain better results, though the two methods are equal in some cases.
基金Supported by the National Natural Science Foundation of China
文摘A passive and multi-channel microwave sounder onboard the Chang'e-2 orbiter has successfully acquired microwave observations of the lunar surface and subsurface structure. Compared with the Chang'e-1 orbiter, the Chang'e-2 orbiter obtained more accurate and comprehensive microwave brightness temperature data, which are helpful for further research. Since there is a close relationship between mi- crowave brightness temperature data and some related properties of the lunar regolith, such as the thickness, temperature and dielectric constant, precise and high resolution brightness temperature data are necessary for such research. However, through the detection mechanism of the microwave sounder, the brightness temperature data ac- quired from the microwave sounder are weighted by the antenna radiation pattern, so the data are the convolution of the antenna radiation pattern with the lunar brightness temperature. In order to obtain the real lunar brightness temperature, a deconvolution method is needed. The aim of this paper is to solve the problem associated with per- forming deconvolution of the lunar brightness temperature. In this study, we introduce the maximum entropy method (MEM) to process the brightness temperature data and achieve excellent results. The paper mainly includes the following aspects: first, we introduce the principle of the MEM; second, through a series of simulations, the MEM has been verified as an efficient deconvolution method; and third, the MEM is used to process the Chang'e-2 microwave data and the results are significant.
基金supported in part by the National Key Research and Development Program of China(2021YFB3900300)in part by the National Natural Science Foundation of China(62201416)+2 种基金in part by the Fundamental Research Funds for the Central Universities(QTZX23070)in part by the Qin Chuang Yuan High-Level Innovative and Entrepreneurial Talents Project(QCYRCXM-2022-314)in part by Singapore Ministry of Education Academic Research Fund Tier 1。
文摘This work presents an optimal design method of antenna aperture illumination for microwave power transmission with an annular collection area.The objective is to maximize the ratio of the power radiated on the annular collection area to the total transmitted power.By formulating the aperture amplitude distribution through a summation of a special set of series,the optimal design problem can be reduced to finding the maximum ratio of two real quadratic forms.Based on the theory of matrices,the solution to the formulated optimization problem is to determine the largest characteristic value and its associated characteristic vector.To meet security requirements,the peak radiation levels outside the receiving area are considered to be extra constraints.A hybrid grey wolf optimizer and Nelder–Mead simplex method is developed to deal with this constrained optimization problem.In order to demonstrate the effectiveness of the proposed method,numerical experiments on continuous apertures are conducted;then,discrete arrays of isotropic elements are employed to validate the correctness of the optimized results.Finally,patch arrays are adopted to further verify the validity of the proposed method.
基金supported by the National Natural Science Foundation of China (U1303291)the Program for Changjiang Scholars and Innovative Research Team in University (No. IRT_15R46)
文摘Fe-based carbon materials are widely considered promising to replace Pt/C as next-generation electrocatalysts towards oxygen reduction reaction (ORR). However, the preparation of Fe-based carbon materials is still carried out by conventional heating method (CHM). Herein, a novel microwave-assisted carbon bath method (MW-CBM) was proposed, which only took 35 min to synthesize Fe/Fe3C nanoparticles encapsulated in N-doped carbon layers derived from Prussian blue (PB). The catalyst contained large specific surface area and mesoporous structure, abundant Fe-Nx and C–N active sites, unique core-shell structure. Due to the synergistic effects of these features, the as-prepared Fe/Fe3C@NC-2 displayed outstanding ORR activity with onset potential of 0.98 VRHE and halfwave potential of 0.87 VRHE, which were more positive than 20 wt.% Pt/C (0.93 VRHE and 0.82 VRHE). Besides, Fe/Fe3C@NC-2 gave a better stability and methanol tolerance than Pt/C towards ORR in alkaline media, too.
文摘This paper investigates a microwave heating method for the determination of chemical oxygen demand (COD) in seawater. The influences of microwave-power, heating time and standard substances on the results are studied. Using the proposed method, we analyzed the glucose standard solution, the coefficient of variation being less than 2%. Compared with the traditional electric stove heating method, the results of F-test and T-test showed that there was no significant difference between the two methods, but the microwave method had slightly higher precision and reproducibility than the electric stove method. With the microwave heating method, several seawater samples from Jiaozhou Bay and the South Yellow Sea were also analyzed. The recovery was between 97.5% and 104.3%. This new method has the advantages of shortening the heating time, improving the working efficiency and having simple operation and therefore can be used to analyze the COD in seawater.
基金supported by the National Natural Science Foundation of China(21376113)the Jiangsu Specially Appointed Professor Projectthe Graduate Student Scientific Research Innovation Projects in Jiangsu Province(KYZZ15_0384)~~
文摘A Pt/graphene‐TiO2catalyst was prepared by a microwave‐assisted solvothermal method and was characterized by X‐ray diffraction,scanning electron microscopy,transmission electron microscopy,cyclic voltammetry,and linear sweep voltammetry.The cubic TiO2particles were approximately60nm in size and were distributed on the graphene sheets.The Pt nanoparticles were uniformly distributed between the TiO2particles and the graphene sheet.The catalyst exhibited a significant improvement in activity and stability towards the oxygen reduction reaction compared with Pt/C,which resulted from the high electronic conductivity of graphene and strong metal‐support interactions.
基金Project supported by the National Key Research and Development Program of China(Grant No.2021YFB3501300)the National Natural Science Foundation of China(Grant No.51731001)the Fund from the State Key Laboratory of Baiyunobo Rare Earth Resource Researches and Comprehensive Utilization’s Key Research and Development Projects。
文摘As concepts closely related to microwave absorption properties,impedance matching and phase matching were rarely combined with material parameters to regulate properties and explore related mechanisms.In this work,reduction–diffusion method was innovatively applied to synthesize rare earth alloy Y_(2)Fe_(17).In order to regulate the electromagnetic parameters of absorbers,the Y_(2)Fe_(17)N_(3-δ)particles were coated with silica(Y_(2)Fe_(17)N_(3-δ)@SiO_(2))and absorbers with different volume fractions were prepared.The relationship between impedance matching,matching thickness,and the strongest reflection loss peak(RLmin)was presented obviously.Compared to the microwave absorption properties of Y_(2)Fe_(17)N_(3-δ)/PU absorber,Y_(2)Fe_(17)N_(3-δ)@SiO_(2)/PU absorbers are more conducive to the realization of microwave absorption material standards which are thin thickness,light weight,strong absorbing intensity,and broad bandwidth.Based on microwave frequency bands,the microwave absorption properties of the absorbers were analyzed and the related parameters were listed.As an important parameter related to perfect matching,reflection factor(√ε_(r)/μ_(r))was discussed combined with microwave amplitude attenuation.According to the origin and mathematical model of bandwidth,the formula of EAB(RL<-10 dB)was derived and simplified.The calculated bandwidths agreed well with experimental results.
文摘A new approach based on resonance technique and modified boundary ele-ment method is presented to calculate the impedance parameter matrix of a microwaveN-port network of waveguide structure.A two port network is taken as a numerical ex-ample and the results show that the approach occupys the advantages of high accuracyand less computation effort.
文摘Decoction of Kampo medicines plays an important role in clinical practice, especially in individualized treatment, while the inconvenience and a long time requirement of the decocting process are impediments to its widespread use in Japan. In this study, we improved the decocting method by using a microwave oven such as those found in most kitchens. To validate the feasibility and safety of this new method, we decocted kakkonto, which is the most widely used formula in clinical treatment in Japan, and keishikabushito, which contains toxic components using a microwave oven. Regarding the contents of 8 characteristic components in the kakkonto decoction and the contents of 6 toxic components in the keishikabushito decoction as indices, and with the extraction and detoxification effects equal to those of the conventional decocting method as targets, we optimized the decocting conditions with Response Surface Methods. With this new method, it took 35 min to obtain almost the same extraction effect for kakkonto as with the conventional decocting method, which takes 40 min;meanwhile, it took only 45 min to detoxify keishikabushito, which takes 60 min using the conventional decocting method. Decocting Kampo medicines with a microwave oven is feasible and as safe as the conventional decocting method. It is a convenient, safe, time-saving method, and may be applied widely in clinical practice. This innovation should allow more patients to benefit from decoction and the individualized treatment it offers.
文摘In this peper we have synthesized powder crystal form (Y,Gd) BO3:Eu(3+)Phosphors by microwave heating method. ItS structure belongs to hexagonal system with lattice parameters a=0.3796,c=0. 8835. Its excitation spetra peaks at 239.0nm and 240. 0nm monitored at the emission of 589nm and 612nm respectively, the half peak width is 40nm. Under 240nm excitation the phosphors show a strons oranse-red luminescence, the fluorescent intensity ratio for I589/I612 is 1.9/1
文摘This article examined in detail microwave radiometer functioning algorithm with synchronously using of the two types of pulse modulation: amplitude pulse modulation and pulse-width modulation. This allows a zero-radiometer measurement method to realize when the fluctuation effect of the receiver gain and the influence of its own noise changes are minimized. A zero balance automatically maintains in radiometer. The antenna signal is indirectly determined through the signal duration that controls the pulse-width modulation. An analytical expression of the fluctuation sensitivity was obtained in a general form. From its analysis gain in sensitivity, conditions were defined by the optimizing of the radiometer input knot’s construction. Three modifications of the radiometer input knot were researched. Fluctuation sensitivity at different measurement range was determined for modification of the radiometer input knot.
文摘Using a low power microwave generator and a surfatron discharge cavity, Ti3O5 was synthesized via the hydrogenation of TiO2 in surface wave induced microwave plasma. Besides, the chemical behavior of hydrogen in the plasma and its influence on the formation of Ti3O5 were preliminarily studied.
文摘Objective: To investigate the electromagnetic field and specific absorptionrate (SAR) distribution of different structure applicators with different depths for treating bonetumors using microwave hyperthermia. Methods: The finite element method (FEM) was used to calculate,electromagnetic field and SAR distribution. Two different structure applicators were simulated. Theone is simple coaxial antenna, which has been successfully used in clinic treating bone tumors inTangdu hospital of the Forth Military Medical University several years. It was formed by a coaxialcable peeled off the out copper at end. The other applicator was coaxial- slot antenna, which waswidely used in microwave hyperthermia. The applicator inserted into the cylindrical bone withdifferent depths, and worked at the frequency of 2 450 MHz. Results: The electric field and SARgenerated by the simple coaxial applicator were mainly concentrated out the tissues, and were notuniform in the tissues, while the coaxial- slot applicator well transmits the electric field and SARinto the tissues, and can easily treat different position by adjusting the slat position.Conclusion: The results calculated by EFM, were well accordant with the experimental and clinicalresulls, and will be important for improving the clinical effects of microwave hyperthermia.
基金Project(U1202272)supported by the National Natural Science Foundation of China
文摘A novel synthesis method of carbon-coated LiNil/3Mnl/3COl/302 cathode material for lithium-ion battery was reported. The carbon coating was produced from a precursor, glucose, by microwave-pyrolysis method. The prepared powders were characterized by scanning electron microscopy (SEM), X-ray diffraction (XRD), X-ray fluorescence (XRF) and charge/discharge tests. XRD results indicate that the carbon coating does not change the phase structure of LiNil/3Mnl/3C01/302 material. SEM results show that the surface of spherical carbon-coated material becomes rough. Electrochemical performance results show that the carbon coating can improve the cycling performance of LiNii/3Mnl/3C01/302. The specific discharge capacity retention of the carbon-coated LiNi1/3Mnt/3Col/30z reached 85.0%-96.0% at the 50th cycle at 0.2C rate, and the specific discharge capacity retention is improved at a high rate.