Stainless steel continuous annealing furnace is mainly used for heat treatment of hot-rolled strip steel.The combustion air will be enabled to heat to 520℃by waste heat recovery system,but the discharge temperature i...Stainless steel continuous annealing furnace is mainly used for heat treatment of hot-rolled strip steel.The combustion air will be enabled to heat to 520℃by waste heat recovery system,but the discharge temperature is still up to about 300℃.Owing to with development of global emphasis on energy conservation energy saving and discharge reduction,it's significant to lower the discharge temperature to below 200℃, for the sake of achieving rational use of waste heat resource.Through the analysis of the existing heat recovery system by this study,it is proved that mixing low temperature with flue gas in high temperature standard will increase the capacity of the flue gas and deteriorate the quality of remaining heat resource.In stead of that,increasing the combustion air temperature to 600℃on the basis of stability temperature for the prerequisite of recuperator design,and giving priority to reducing fuel consumption are the better way.The recovery and recycle of low temperature gas are also be introduced.It is demonstrated by the way of setting a secondary recuperator at the exit of the primary recuperator,and using low temperature flue gas to heat the air used for drying the strip steel,the exhuast temperature of flue gas can be reduced to lower than 200℃.At the same time,the steam required for heating air is saved,the energy reserve as high as 2 300 t of standard coal per year.展开更多
The low-grade heat source recovery is usually constrained by the physical characteristics of the hot fluid medium. The present work focuses on the importance of energy recovery from low-temperature waste energy source...The low-grade heat source recovery is usually constrained by the physical characteristics of the hot fluid medium. The present work focuses on the importance of energy recovery from low-temperature waste energy sources and its conversion to useful electrical power. The thermal performance analysis is based on the utilization of R-123, R-134a, R-290, R-245fa, R-1234ze-E, and R-1233zd-E fluids in a simple organic Rankine cycle (SORC). A waste energy source from an industrial sector is suggested to be available at a temperature greater than 110 °C. A hypothetical organic Rankine cycle of 10 kW nominal heat recovery was implemented to evaluate the cycle performance. It operates at evaporation and condensation temperatures of 90 °C and 45 °C, respectively. The selected vapor superheat degree at the expander entrance was 5 °C - 15 °C, and the liquid was subcooled by 5 °C at the discharge port of condenser. The estimated first law cycle thermal efficiency fell in the range of 6.4% - 7.7%. The results showed that the thermal efficiencies of R-134a, R-123, R-245fa, R-1233zd-E, and R-1234ze-E were higher than that of R-290 by 10% - 14%, 11% - 12%, 9% - 12%, 4% - 7% and 1% - 3%, respectively. R-1233zd-E, R-1234ze-E, and R-290 showed close thermal efficiency values, and it fell in the range of 6.7% - 7% for the (SORC) at a superheat degree of 15 °C. At the same superheat degree, the corresponding range of thermal efficiency for R-134a, R-123 and R-245fa fell within 7.5% - 7.7%. R-134a possessed the highest net power output of the (SORC);it reached a value of 0.91 kW as predicted at 15 °C superheat degree. Increasing the expander volumetric efficiency value by 10% improved the cycle thermal efficiency by 10% - 12%.展开更多
Thermal loss of exhaust flue gas accounts for the largest proportion of the total boiler thermal loss. Nowadays in China, the exhaust gas temperature in many thermal power plants is much higher than the designed value...Thermal loss of exhaust flue gas accounts for the largest proportion of the total boiler thermal loss. Nowadays in China, the exhaust gas temperature in many thermal power plants is much higher than the designed value, thus, the recycle and reuse of the waste heat of tail flue gas is necessary. However, lower exhaust gas temperature will aggravate low temperature corrosion of the tail heating surface, which also causes huge economic losses. In order to solve this problem, this paper designs a monitoring experiment platform of flue gas low temperature corrosion, which can measure the corrosion condition of different materials by different flue gas compositions and temperature corrosion speeds. Besides, effects of low temperature corrosion factors are analyzed to find the best exhaust gas temperature and the surface material of tail heating surface.展开更多
文摘Stainless steel continuous annealing furnace is mainly used for heat treatment of hot-rolled strip steel.The combustion air will be enabled to heat to 520℃by waste heat recovery system,but the discharge temperature is still up to about 300℃.Owing to with development of global emphasis on energy conservation energy saving and discharge reduction,it's significant to lower the discharge temperature to below 200℃, for the sake of achieving rational use of waste heat resource.Through the analysis of the existing heat recovery system by this study,it is proved that mixing low temperature with flue gas in high temperature standard will increase the capacity of the flue gas and deteriorate the quality of remaining heat resource.In stead of that,increasing the combustion air temperature to 600℃on the basis of stability temperature for the prerequisite of recuperator design,and giving priority to reducing fuel consumption are the better way.The recovery and recycle of low temperature gas are also be introduced.It is demonstrated by the way of setting a secondary recuperator at the exit of the primary recuperator,and using low temperature flue gas to heat the air used for drying the strip steel,the exhuast temperature of flue gas can be reduced to lower than 200℃.At the same time,the steam required for heating air is saved,the energy reserve as high as 2 300 t of standard coal per year.
文摘The low-grade heat source recovery is usually constrained by the physical characteristics of the hot fluid medium. The present work focuses on the importance of energy recovery from low-temperature waste energy sources and its conversion to useful electrical power. The thermal performance analysis is based on the utilization of R-123, R-134a, R-290, R-245fa, R-1234ze-E, and R-1233zd-E fluids in a simple organic Rankine cycle (SORC). A waste energy source from an industrial sector is suggested to be available at a temperature greater than 110 °C. A hypothetical organic Rankine cycle of 10 kW nominal heat recovery was implemented to evaluate the cycle performance. It operates at evaporation and condensation temperatures of 90 °C and 45 °C, respectively. The selected vapor superheat degree at the expander entrance was 5 °C - 15 °C, and the liquid was subcooled by 5 °C at the discharge port of condenser. The estimated first law cycle thermal efficiency fell in the range of 6.4% - 7.7%. The results showed that the thermal efficiencies of R-134a, R-123, R-245fa, R-1233zd-E, and R-1234ze-E were higher than that of R-290 by 10% - 14%, 11% - 12%, 9% - 12%, 4% - 7% and 1% - 3%, respectively. R-1233zd-E, R-1234ze-E, and R-290 showed close thermal efficiency values, and it fell in the range of 6.7% - 7% for the (SORC) at a superheat degree of 15 °C. At the same superheat degree, the corresponding range of thermal efficiency for R-134a, R-123 and R-245fa fell within 7.5% - 7.7%. R-134a possessed the highest net power output of the (SORC);it reached a value of 0.91 kW as predicted at 15 °C superheat degree. Increasing the expander volumetric efficiency value by 10% improved the cycle thermal efficiency by 10% - 12%.
文摘Thermal loss of exhaust flue gas accounts for the largest proportion of the total boiler thermal loss. Nowadays in China, the exhaust gas temperature in many thermal power plants is much higher than the designed value, thus, the recycle and reuse of the waste heat of tail flue gas is necessary. However, lower exhaust gas temperature will aggravate low temperature corrosion of the tail heating surface, which also causes huge economic losses. In order to solve this problem, this paper designs a monitoring experiment platform of flue gas low temperature corrosion, which can measure the corrosion condition of different materials by different flue gas compositions and temperature corrosion speeds. Besides, effects of low temperature corrosion factors are analyzed to find the best exhaust gas temperature and the surface material of tail heating surface.