期刊文献+
共找到4,744篇文章
< 1 2 238 >
每页显示 20 50 100
On Dynamic Channel Emulation in Sector MPAC for Over-the-Air Testing of Beamformed Massive MIMO Devices
1
作者 Xiaochen Chen Heng Wang +2 位作者 Weimin Wang Zheng Liu Yuanan Liu 《China Communications》 SCIE CSCD 2023年第4期41-56,共16页
In this article,novel emulation strategies for the sectored multiple probe anechoic chamber(SMPAC)are proposed to enable the reliable evaluation of the massive multiple-input multiple-output(MIMO)device operating at b... In this article,novel emulation strategies for the sectored multiple probe anechoic chamber(SMPAC)are proposed to enable the reliable evaluation of the massive multiple-input multiple-output(MIMO)device operating at beamforming mode,which requires a realistic non-stationary channel environment.For the dynamic propagation emulation,an efficient closed-form probe weighting strategy minimizing the power angular spectrum(PAS)emulation errors is derived,substantially reducing the associated computational complexity.On the other hand,a novel probe selection algorithm is proposed to reproduce a more accurate fading environment.Various standard channel models and setup configurations are comprehensively simulated to validate the capacity of the proposed methods.The simulation results show that more competent active probes are selected with the proposed method compared to the conventional algorithms.Furthermore,the derived closedform probe weighting strategy offers identical accuracy to that obtained with complicated numerical optimization.Moreover,a realistic dynamic channel measured in an indoor environment is reconstructed with the developed methodologies,and 95.6%PAS similarity can be achieved with 6 active probes.The satisfactory results demonstrate that the proposed algorithms are suitable for arbitrary channel emulation. 展开更多
关键词 BEAMFORMING channel emulation massive MIMO device multiple probe anechoic chamber(MPAC) over-the-air testing
下载PDF
Flexible substructure online hybrid test system using conventional testing devices 被引量:2
2
作者 Wang Tao Masayoshi Nakashima 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2013年第3期341-350,共10页
This paper presents a substructure online hybrid test system that is extensible for geographically distributed tests. This system consists of a set of devices conventionally used for cyclic tests to load the tested su... This paper presents a substructure online hybrid test system that is extensible for geographically distributed tests. This system consists of a set of devices conventionally used for cyclic tests to load the tested substructures onto the target displacement or the target force. Due to their robustness and portability, individual sets of conventional loading devices can be transported and reconfigured to realize physical loading in geographically remote laboratories. Another appealing feature is the flexible displacement-force mixed control that is particularly suitable for specimens having large disparities in stiffness during various performance stages. To conduct a substructure online hybrid test, an extensible framework is developed, which is equipped with a generalized interface to encapsulate each substructure. Multiple tested substructures and analyzed substructures using various structural program codes can be accommodated within the single framework, simply interfaced with the boundary displacements and forces. A coordinator program is developed to keep the boundaries among all substructures compatible and equilibrated. An Interuet-based data exchange scheme is also devised to transfer data among computers equipped with different software environments. A series of online hybrid tests are introduced, and the portability, flexibility, and extensibility of the online hybrid test system are demonstrated. 展开更多
关键词 substructure online hybrid test conventional loading device displacement-force mixed control coordinator program Interuet-based data exchange scheme
下载PDF
Research on the overload protection reliability of moulded case circuit-breakers and its test device 被引量:14
3
作者 LI Kui LU Jian-guo WU Yi QIN Zhi-jun YAO Dong-mei 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2007年第3期453-458,共6页
This paper analyzed the reliability and put forward the reliability index of overload protection for moulded case circuit breaker. The success rate was adopted as its reliability index of overload protection. Based on... This paper analyzed the reliability and put forward the reliability index of overload protection for moulded case circuit breaker. The success rate was adopted as its reliability index of overload protection. Based on the reliability index and the reli- ability level, the reliability examination plan was analyzed and a test device for the overload protection of moulded case cir- cuit-breaker was developed. In the reliability test of overload protection, two power sources were used, which reduced the time of conversion and regulation between two different test currents in the overload protection test, which made the characteristic test more accurate. The test device was designed on the base of a Windows system, which made its operation simple and friendly. 展开更多
关键词 超负载防护 可靠性 测试器 塑壳式断路器
下载PDF
Testing Research about Characteristic Parameters of the Grounding Device at 750 kV Substation of Riyue Mountain,Qinghai
4
作者 Chengshan Yang Yanjun Xin 《Meteorological and Environmental Research》 CAS 2013年第8期14-16,20,共4页
750 kV substation of Riyue Mountain, Qinghai is a substation that annual average thunderstorm days are the maximum at the same volt- age level and altitude in the wodd. We detailedly described testing methods and step... 750 kV substation of Riyue Mountain, Qinghai is a substation that annual average thunderstorm days are the maximum at the same volt- age level and altitude in the wodd. We detailedly described testing methods and steps of 6 characteristic parameters for grounding device of 750 kV substation by using 8000S comprehensive test system, and scientifically judged overall performance of the grounding device. Moreover, we espe- cially emphasized key and difficult points in testing process, providing reference for the majority of grounding test workers. 展开更多
关键词 750 kV substation Grounding device Characteristic parameters testing research China
下载PDF
A Smart Substation Field Secondary Device Testing Technique Based on Recurrence Principle
5
作者 Kanjun Zhang Lei Chen +5 位作者 Yongjun Xia Yang Lei Xin Shu Hengxuan Li Ting Wang Zhenan Du 《Journal of Power and Energy Engineering》 2014年第4期244-251,共8页
According to the demand of substation secondary device dynamic performance testing, a smart substation field testing technique based on recurrence principle is proposed in the paper, and the characteristics of smart s... According to the demand of substation secondary device dynamic performance testing, a smart substation field testing technique based on recurrence principle is proposed in the paper, and the characteristics of smart substation secondary device digitization and information sharing are used by the technique. The principle of testing technique is as follow: the digital simulation model is constructed on the basis of the substation’s actual construction, then the simulating data highly similar to substation’s actual electric quantity transient process is generated, at last, the substation digital secondary device can be tested by using data “recurrence” technique. The testing technique is verified and applied by constructing testing system, the application results show that the technique can effectively perform field test on the dynamic performance of digital secondary device, and the technique has good engineering implementation and application value. 展开更多
关键词 Smart Substation SECONDARY device Dynamic Performance Data RECURRENCE FIELD testING TECHNIQUE
下载PDF
Test and Evaluation of Stiffness of a Pin Turning Device for Large Marine Engine Crankshafts
6
作者 Y. H. Choi G. B. Ha +1 位作者 D. H. Kim H. S. An 《Journal of Power and Energy Engineering》 2013年第7期14-19,共6页
In order to prevent unwanted excited vibrations and to secure better machining precision in large size heavy duty machine tools dynamic stiffness is one of the most desirable and critical properties. In the past decad... In order to prevent unwanted excited vibrations and to secure better machining precision in large size heavy duty machine tools dynamic stiffness is one of the most desirable and critical properties. In the past decades, many researches on machine tool stiffness test and evaluation methodology have been made. However any methodology for a Pin Turning Device (PTD), which is a special kind of turning lathe for machining big size crankshaft pins, is rarely found among them. This study proposes a test and evaluation process of stiffness of a PTD by measuring frequency response function at the tool center point (TCP). For conformance proving for the proposed methodology, stiffness of a PTD obtained by the proposed method with impact hammer test (IHT) has been compared with that determined by FEM. 展开更多
关键词 PIN TURNING device (PTD) Machine Tool STIFFNESS COMPLIANCE Response Function Impact HAMMER test
下载PDF
A model test system with a dynamic load device for geotechnical engineering in cold regions
7
作者 ShuPing Zhao Wei Ma +1 位作者 GuiDe Jiao Fei Luo 《Research in Cold and Arid Regions》 2012年第2期115-120,共6页
A model test system with a dynamic load device for geotechnical engineering in cold regions is presented. This system consists of a model test tank, a refrigeration device and temperature controller, a dynamic load de... A model test system with a dynamic load device for geotechnical engineering in cold regions is presented. This system consists of a model test tank, a refrigeration device and temperature controller, a dynamic load device, together with sensors and data loggers for detecting stress, deformation, and temperature changes. The system can accommodate soil blocks up to 3 m in length, 2.5 m in width, and 1 m in height. The lowest temperature provided by the refrigeration device is -20 ℃. The maximum load provided by the dynamic load device is 100 kN and the vibration fi'equency of the dynamic load can range from 0.1 to 10 Hz. A number of waveforms, such as sine waves, rectangular waves, triangle waves, and other user-defined waves can be generated by the dynamic load device controller. 展开更多
关键词 model test system dynamic load device STRESS DEFORMATION temperature change
下载PDF
DEM Simulation to Determine the Influence on the Experimental Results of Tests of Iron Pellets When the Dimensions of the Test Device Are Varied
8
作者 Yerko Aguilera-Carvajal Yonathan Tapia Robledo Sebastián Perez Cortes 《International Journal of Modern Nonlinear Theory and Application》 2021年第2期65-80,共16页
The current study is based on the DEM computer simulation of three experimental test devices with different dimensions to determine the difference in the results of the formation of shear and repose angles that the pa... The current study is based on the DEM computer simulation of three experimental test devices with different dimensions to determine the difference in the results of the formation of shear and repose angles that the particles experience when grouped under the action of the gravitational force. In this respect, the experimental test devices with different height, width, and depth were geometrically modeled with iron pellet particles using morphology and a granulometric variation from 6 mm to 9 mm of equivalent diameter in its spherical shape. Depending on the results obtained, a reliable size of the experimental test device will be available to obtain the necessary data for a correct adjustment of the calibration parameters for the DEM simulation of mining-metallurgical processes that use granulated material of iron pellet. 展开更多
关键词 Discrete Elements Method CALIBRATION test device DEM Parameters
下载PDF
Design of New Elevator Pressure Guide Plate and Its Test Device
9
作者 Qihang Xu Shaoke Chen 《Mechanical Engineering Science》 2019年第1期7-13,共7页
Pressure guide plate plays a certain role in the safe operation of elevator.Based on understanding the respective performance of new and old pressure guide plates,this paper analyses the problems existing in the origi... Pressure guide plate plays a certain role in the safe operation of elevator.Based on understanding the respective performance of new and old pressure guide plates,this paper analyses the problems existing in the original pressure guide plate.It also conducts stress analysis according to the function of pressure guide plate on elevator,and designs a new type of pressure guide plate combined with technological capability and equipment.According to the stress characteristics,a test device is designed and a comparative test is made between the new type of pressure guide plate and the old in order to test the reliability of the new type of pressure guide plate.The test proves that the new pressure guide plate of elevator can meet the requirements of product use and safe operation of elevator products. 展开更多
关键词 PRESSURE GUIDE PLATE test device GUIDE RAILS ELEVATOR
下载PDF
基于Device Net现场总线的电动机综合保护测控装置
10
作者 张东中 佟为明 +1 位作者 刘勇 高洪伟 《电子器件》 EI CAS 2006年第4期1151-1154,共4页
为提高继电保护装置的通信方法、实时响应及信号处理等性能,开发了一种基于DeviceNet总线的双CPU结构的电动机综合保护测控装置。在分析DeviceNet数据触发方式、通信连接、报文类型等关键技术的基础上,实现了针对该装置的对象建模和设... 为提高继电保护装置的通信方法、实时响应及信号处理等性能,开发了一种基于DeviceNet总线的双CPU结构的电动机综合保护测控装置。在分析DeviceNet数据触发方式、通信连接、报文类型等关键技术的基础上,实现了针对该装置的对象建模和设备描述,并使其顺利通过联网测试。该装置集保护、测量、控制和通信等多种功能于一体。动态模拟试验和现场运行结果表明,该装置能对35 kV及以下电压等级的中压电动机的各种故障做出准确判断,并具有较高的测量精度和良好的控制性能。 展开更多
关键词 现场总线 电动机综合保护测控装置 数字信号处理器 单片机
下载PDF
Evaluation of mercury speciation and removal through air pollution control devices of a 190 MW boiler 被引量:13
11
作者 Chengli Wu Yan Cao +3 位作者 Zhongbing Dong Chinmin Cheng Hanxu Li Weiping Pan 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2010年第2期277-282,共6页
Air pollution control devices (APCDs) are installed at coal-fired power plants for air pollutant regulation. Selective catalytic reduction (SCR) and wet flue gas desulftLrization (FGD) systems have the co-benefi... Air pollution control devices (APCDs) are installed at coal-fired power plants for air pollutant regulation. Selective catalytic reduction (SCR) and wet flue gas desulftLrization (FGD) systems have the co-benefits of air pollutant and mercury removal. Configuration and operational conditions of APCDs and mercury speciation affect mercury removal efficiently at coal-fired utilities. The Ontario Hydro Method (OHM) recommended by the U.S. Environmental Protection Agency (EPA) was used to determine mercury speciation simultaneously at five sampling locations through SCR-ESP-FGD at a 190 MW unit. Chlorine in coal had been suggested as a factor affecting the mercury speciation in flue gas; and low-chlorine coal was purported to produce less oxidized mercury (Hg^2+) and more elemental mercury (Hg^0) at the SCR inlet compared to higher chlorine coal. SCR could oxidize elemental mercury into oxidized mercury when SCR was in service, and oxidation efficiency reached 71.0%. Therefore, oxidized mercury removal efficiency was enhanced through a wet FGD system. In the non-ozone season, about 89.5%-96.8% of oxidized mercury was controlled, but only 54.9%-68.8% of the total mercury was captured through wet FGD. Oxidized mercury removal efficiency was 95.9%-98.0%, and there was a big difference in the total mercury removal efficiencies from 78.0% to 90.2% in the ozone season. Mercury mass balance was evaluated to validate reliability of OHM testing data, and the ratio of mercury input in the coal to mercury output at the stack was from 0.84 to 1.08. 展开更多
关键词 mercury speciation mercury removal air pollution control device field testing
下载PDF
Parametric study of single confined fragment launch explosive device 被引量:3
12
作者 Pankaj K.Choudha A.Kumaraswamy Kusumkant D.Dhote 《Defence Technology(防务技术)》 SCIE EI CAS CSCD 2019年第2期179-185,共7页
In this article, parametric study of single confined fragment launch device was carried out. The configuration proposed was further studied to derive the empirical relationship for effect of fragment size,charge size,... In this article, parametric study of single confined fragment launch device was carried out. The configuration proposed was further studied to derive the empirical relationship for effect of fragment size,charge size, confinement thickness on fragment velocity. The simulations were carried out using ANSYSAUTODYNE explicit solver. Fragment velocities were estimated as a function of different parametric combinations of explosive quantities, charge length to diameter ratio, fragment height to diameter ratio,confinement thickness, fragment material and fragment mass. The data was further converted to charge to metal ratio under fragment and confinement. It was observed that, increase in confinement thickness,charge quantity and decrease in fragment height increases the fragment velocity. It is also noted that,charge to metal mass ratio under fragment significantly affects the fragment velocity. At the end, an empirical relationship for fragment velocity interms of all these parameters was established. Using these relations, two velocities 1831.92 m/s and 2523.9 m/s required for NATO STANAG 4496 IM test were estimated. The design parameters for these velocities are presented. Also, the results estimated using the empirical relationship has been compared with published experimental data. Error in the predicted velocities is within the acceptable range. The empirical relationship proposed will be useful for finalization of design of the fragment launch device. 展开更多
关键词 CONFINEMENT FRAGMENT size Empirical relationship FRAGMENT velocity Insensitive munition test FRAGMENT LAUNCHING device
下载PDF
Review on failure analysis of interconnections in power devices 被引量:2
13
作者 黄伟 陈志文 《China Welding》 CAS 2022年第1期6-14,共9页
Interconnections in microelectronic packaging are not only the physical carrier to realize the function of electronic circuits,but also the weak spots in reliability tests.Most of failures in power devices are caused ... Interconnections in microelectronic packaging are not only the physical carrier to realize the function of electronic circuits,but also the weak spots in reliability tests.Most of failures in power devices are caused by the malfunction of interconnections,including failure of bonding wire as well as cracks of solder layer.In fact,the interconnection failure of power devices is the result of a combination of factors such as electricity,temperature,and force.It is significant to investigate the failure mechanisms of various factors for the failure analysis of interconnections in power devices.This paper reviews the main failure modes of bonding wire and solder layer in the interconnection structure of power devices,and its failure mechanism.Then the reliability test method and failure analysis techniques of interconnection in power device are introduced.These methods are of great significance to the reliability analysis and life prediction of power devices. 展开更多
关键词 power device reliability test failure analysis INTERCONNECTION
下载PDF
In vitro evaluation of a new resilient, hard-carbon, thin-film coating as a bearing material for ventricular assist devices ——In Vitro Bearing Evaluation of BioMedFlex 被引量:1
14
作者 Nicole A. Mielke Alex L. Massiello +4 位作者 David J. Horvath Stephen M. Benefit Darren Burgess Leonard A. R. Golding Kiyotaka Fukamachi 《Journal of Biomedical Science and Engineering》 2010年第5期525-528,共4页
Our aim was to evaluate the potential use of BioMedFlex? (BMF), a new resilient, hard-carbon, thin- film coating, as a blood journal bearing material in Cleveland Heart’s continuous-flow left and right ven- tricular ... Our aim was to evaluate the potential use of BioMedFlex? (BMF), a new resilient, hard-carbon, thin- film coating, as a blood journal bearing material in Cleveland Heart’s continuous-flow left and right ven- tricular assist devices (VADs). BMF is not classified as a diamond-like carbon (DLC) and differs from other thin-film carbon coatings by its high flexural strength, radiopacity, and wear resistance. A 2- to 4-μm-thick BMF adhesion layer was deposited on the VAD journal bearing surfaces. A commercial DLC coating used in other clinical blood pump applications was used as a control. Durability and reliability of the BMF coating was verified in severe pump start/stop testing using 20 BMF-coated journal bearing pairs. The BMF-coated surfaces showed no coating failures, whereas 57% of the DLC bearing pairs developed scratches through the carbon coating, documenting that BMF can provide a durable coating in our blood journal bearing application. In conclusion, BMF has shown qualities that support its significant advantages as an alternative journal bea- ring material in Cleveland Heart pumps. Our plan includes biocompatibility testing with ongoing animal studies, endurance testing with submerged pumps running in saline, and assessment of batch coating processing capability. 展开更多
关键词 HEART Assist device DIAMOND-LIKE CARBON Materials testing WEAR Resistance Journal BEARING
下载PDF
Determination of inhibitory activity of Salvia miltiorrhiza extracts on xanthine oxidase with a paper-based analytical device 被引量:1
15
作者 Xingchu Gong Jingyuan Shao +2 位作者 Shangxin Guo Jingjing Pan Xiaohui Fan 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2021年第5期603-610,共8页
A novel paper-based analytical device(PAD)was prepared and applied to determine the xanthine oxidase(XOD)inhibitory activity of Salvia miltiorrhiza extracts(SME).First,polycaprolactone was 3D printed on filter paper a... A novel paper-based analytical device(PAD)was prepared and applied to determine the xanthine oxidase(XOD)inhibitory activity of Salvia miltiorrhiza extracts(SME).First,polycaprolactone was 3D printed on filter paper and heated to form hydrophobic barriers.Then the modified paper was cut according to the specific design.Necessary reagents including XOD for the colorimetric assay were immobilized on two separate pieces of paper.By simply adding phosphate buffer,the reaction was performed on the double-layer PAD.Quantitative results were obtained by analyzing the color intensity with the specialized device system(consisting of a smartphone,a detection box and sandwich plates).The 3Dprinted detection box was small,with a size of 9.0 cm×7.0 cm×11.5 cm.Color component G performed well in terms of linearity and detection limits and thus was identified as the index.The reaction conditions were optimized using a definitive screening design.Moreover,a 10%glycerol solution was found to be a suitable stabilizer.When the stabilizer was added,the activity of XOD could be maintained for at least 15 days under 4℃ or-20℃ storage conditions.The inhibitory activity of SME was investigated and compared to that of allopurinol.The results obtained with the PAD showed agreement with those obtained with the microplate method.In conclusion,the proposed PAD method is simple,accurate and has a potential for point-of-care testing.It also holds promise for use in rapid quality testing of medicinal herbs,intermediate products,and preparations of traditional Chinese medicines. 展开更多
关键词 Paper-based analytical device(PAD) Point-of-care testing Xanthine oxidase Salvia miltiorrhiza extract 3D printing
下载PDF
The properties of Sn-Zn-Al-La fusible alloy for mitigation devices of solid propellant rocket motors 被引量:1
16
作者 Zi-ting Wei Nan Li +5 位作者 Jian-xin Nie Jia-hao Liang Xue-yong Guo Shi Yan Tao Zhang Qing-jie Jiao 《Defence Technology(防务技术)》 SCIE EI CAS CSCD 2022年第9期1688-1696,共9页
The Al and La elements are added to the Sn9Zn alloy to obtain the fusible alloy for the mitigation devices of solid propellant rocket motors. Differential scanning calorimetry(DSC), metallographic analysis,scanning el... The Al and La elements are added to the Sn9Zn alloy to obtain the fusible alloy for the mitigation devices of solid propellant rocket motors. Differential scanning calorimetry(DSC), metallographic analysis,scanning electron microscopy(SEM), energy dispersive spectroscopy(EDS), tensile testing and fracture analysis were used to study the effect of Al and La elements on the microstructure, melting characteristics, and mechanical properties of the Sn9Zn alloy. Whether the fusible diaphragm can effectively relieve pressure was investigated by the hydrostatic pressure at high-temperature test. Experimental results show that the melting point of the Sn9Zn-0.8Al0·2La and Sn9Zn-3Al0·2La fusible alloys can meet the predetermined working temperature of ventilation. The mechanical properties of those are more than 35% higher than that of the Sn9Zn alloy at-50°C-70°C, and the mechanical strength is reduced by 80% at 175°C. It is proven by the hydrostatic pressure at high-temperature test that the fusible diaphragm can relieve pressure effectively and can be used for the design of the mitigation devices of solid propellant rocket motors. 展开更多
关键词 Mitigation devices Solid propellant rocket motors Sn9Zn Al element La element Hydrostatic pressure at high-temperature test
下载PDF
浅析IEC/EN 61643-11 Low Voltage Surge Protective Devices(低压浪涌保护器)标准及认证测试过程中常见问题 被引量:2
17
作者 王春 《日用电器》 2016年第5期17-21,33,共6页
本文解读了IEC 61643-11:2011及EN 61643-11:2012,Low Voltage Surge Protective Devices低压浪涌保护器测试标准,分析了TYPE 1 SPD,TYPE 2 SPD,TYPE 3 SPD产品在认证测试过程中的常见问题。
关键词 浪涌保护器 性能测试 常见波形 常见问题
下载PDF
Measurement Process of MOSFET Device Parameters with VEE Pro Software for DP4T RF Switch
18
作者 Viranjay M. Srivastava K. S. Yadav G. Singh 《International Journal of Communications, Network and System Sciences》 2011年第9期590-600,共11页
To design a Double-Pole Four-Throw (DP4T) RF switch, measurement of device parameters is required. In this DP4T RF switch CMOS is a unit cell, so with a thin oxide layer of thickness 628 ? which is measured optically.... To design a Double-Pole Four-Throw (DP4T) RF switch, measurement of device parameters is required. In this DP4T RF switch CMOS is a unit cell, so with a thin oxide layer of thickness 628 ? which is measured optically. Some of the material parameters were found by the curve drawn between Capacitance versus Voltage (C-V) and Capacitance versus Frequency (C-F) with the application of Visual Engineering Environment Programming (VEE Pro). To perform the measurement processing at a distance, from the hazardous room, we use VEE Pro software. In this research, to acquire a fine result for RF MOSFET, we vary the voltage with minor increments and perform the measurements by vary the applying voltage from +5 V to –5 V and then back to +5 V again and then save this result in a data sheet with respect to temperature, voltage and frequency using this program. We have investigated the characteristics of RF MOSFET, which will be used for the wireless telecommunication systems. 展开更多
关键词 Capacitance-Frequency CURVE CAPACITANCE-VOLTAGE CURVE DP4T SWITCH LCR Meter MOS device Radio FREQUENCY RF SWITCH testing VEE PRO VLSI
下载PDF
Design and application of a multichannel"cross"hot tearing tendency device:A study on hot tearing tendency of Al alloys
19
作者 Ming Su Wen-tao Zheng +5 位作者 Deng-ke Fu Hong-jun Huang Xiao-jiao Zuo Chun-yu Yue Yu-xiang Wang Xiao-guang Yuan 《China Foundry》 SCIE CAS 2022年第4期327-334,共8页
Hot tearing is one of the most serious defects during the casting solidification process.In this study,a new type of multichannel"cross"hot tearing device was designed.The hot cracks initiation and propagati... Hot tearing is one of the most serious defects during the casting solidification process.In this study,a new type of multichannel"cross"hot tearing device was designed.The hot cracks initiation and propagation were predicted by the relationship between temperature,shrinkage force and solidification time during the casting solidification process.The reliability and practicability of the multichannel"cross"hot tearing device were verified by casting experiments and numerical simulations.The theoretical calculation based on Clyne-Davies model and numerical simulation results show that the hot tearing tendency decreases in the order:2024 Al alloy>Al-Cu alloy>Al-Si alloy at a pouring temperature of 670°C and a mold temperature of 25°C.Feeding of liquid films at the end of solidification plays an important role in the propagation process of hot tearing.The decrease of hot tearing tendency is attributed to the feeding of liquid film and intergranular bridging. 展开更多
关键词 hot tearing testing device hot cracking tendency solidification process formation mechanism numerical simulation
下载PDF
Effects of left ventricular assist device on pulmonary functions and pulmonary hemodynamics:A meta-analysis
20
作者 Waqas Ullah Casey Meizinger +4 位作者 Zain Ali Ankur Panchal Rehan Saeed Donald C Haas Eduardo Rame 《World Journal of Cardiology》 2020年第11期550-558,共9页
BACKGROUND Given current evidence,the effect of left ventricular assist device(LVAD)implantation on pulmonary function tests remains controversial.AIM To better understand the factors contributing to the changes seen ... BACKGROUND Given current evidence,the effect of left ventricular assist device(LVAD)implantation on pulmonary function tests remains controversial.AIM To better understand the factors contributing to the changes seen on pulmonary function testing and the correlation with pulmonary hemodynamics after LVAD implantation.METHODS Electronic databases were queried to identify relevant articles.The summary effect size was estimated as a difference of overall means and standard deviation on a random-effects model.RESULTS A total of four studies comprising 219 patients were included.The overall mean forced expiratory volume in one second(FEV1),forced vital capacity(FVC)and diffusion lung capacity of carbon monoxide(DLCO)after LVAD implantation were significantly lower by 0.23 L(95%CI:0.11-0.34,P=00002),0.18 L(95%CI:0.03-0.34,P=0.02),and 3.16 mmol/min(95%CI:2.17-4.14,P<0.00001),respectively.The net post-LVAD mean value of the cardiac index was significantly higher by 0.49 L/min/m2(95%CI:0.31-0.66,P<0.00001)compared to pre-LVAD value.The pulmonary capillary wedge pressure and pulmonary vascular resistance were significantly reduced after LVAD implantation by 8.56 mmHg(95%CI:3.78-13.35,P=0.0004),and 0.83 Woods U(95%CI:0.11-1.55,P=0.02),respectively.There was no significant difference observed in the right atrial pressure after LVAD implantation(0.61 mmHg,95%CI:-2.00 to 3.32,P=0.65).Overall findings appear to be driven by studies using HeartMateII devices.CONCLUSION LVAD implantation might be associated with a significant reduction of the spirometric measures,including FEV1,FVC,and DLCO,and an overall improvement of pulmonary hemodynamics. 展开更多
关键词 Pulmonary function tests Left ventricular assist device SPIROMETRY Ventricular assist device
下载PDF
上一页 1 2 238 下一页 到第
使用帮助 返回顶部