Heavy metals,notably Pb2+and Cu^(2+),are some of the most persistent contaminants found in groundwater.Frequent monitoring of these metals,which relies on efficient,sensitive,cost-effective,and reliable methods,is a n...Heavy metals,notably Pb2+and Cu^(2+),are some of the most persistent contaminants found in groundwater.Frequent monitoring of these metals,which relies on efficient,sensitive,cost-effective,and reliable methods,is a necessity.We present a nanocomposite-based miniaturized electrode for the concurrent measurement of Pb2+and Cu^(2+)by exploiting the electroanalytical technique of square wave voltammetry.We also propose a facile in situ hydrothermal calcination method to directly grow binder-free mesoporous Ni O on a three-dimensional nickel foam,which is then electrochemically seeded with gold nanoparticles(Au NPs).The meticulous design of a low-barrier Ohmic contact between mesoporous Ni O and Au NPs facilitates target-mediated nanochannel-confined electron transfer within mesoporous Ni O.As a result,the heavy metals Pb2+(0.020 mg.L^(-1)detection limit;2.0–16.0 mg.L^(-1)detection range)and Cu^(2+)(0.013 mg.L^(-1)detection limit;0.4–12.8 mg.L^(-1)detection range)can be detected simultaneously with high precision.Furthermore,other heavy metal ions and common interfering ions found in groundwater showed negligible impacts on the electrode’s performance,and the recovery rate of groundwater samples varied between 96.3%±2.1%and 109.4%±0.6%.The compactness,flexible shape,low power consumption,and ability to remotely operate our electrode pave the way for onsite detection of heavy metals in groundwater,thereby demonstrating the potential to revolutionize the field of environmental monitoring.展开更多
The polypyrrole is the high conductive polymer which was coated onto indium tin oxide (ITO) glass substrate by electroplated technique to fabricate a miniaturized reference electrode.Besides,the morphology of the ITO...The polypyrrole is the high conductive polymer which was coated onto indium tin oxide (ITO) glass substrate by electroplated technique to fabricate a miniaturized reference electrode.Besides,the morphology of the ITO glass reference electrode electroplated with pyrrole has been studied through the instrumental analysis utilizing cyclic voltammetry (CV). Furthermore,the sensing characteristics of the reference electrode have been measured by using commercial instrumental amplifier as the readout circuit.Using the high conductive polymer as miniaturized reference electrode has many advantages such as easy fabrication of coating polymer,without any expensive fabricating equipment,easy carry by the miniaturized technique.Hence,it is suitable for the reference electrode production.展开更多
基金supported by the National Key Research and Development Project of China(2019YFC1804802)。
文摘Heavy metals,notably Pb2+and Cu^(2+),are some of the most persistent contaminants found in groundwater.Frequent monitoring of these metals,which relies on efficient,sensitive,cost-effective,and reliable methods,is a necessity.We present a nanocomposite-based miniaturized electrode for the concurrent measurement of Pb2+and Cu^(2+)by exploiting the electroanalytical technique of square wave voltammetry.We also propose a facile in situ hydrothermal calcination method to directly grow binder-free mesoporous Ni O on a three-dimensional nickel foam,which is then electrochemically seeded with gold nanoparticles(Au NPs).The meticulous design of a low-barrier Ohmic contact between mesoporous Ni O and Au NPs facilitates target-mediated nanochannel-confined electron transfer within mesoporous Ni O.As a result,the heavy metals Pb2+(0.020 mg.L^(-1)detection limit;2.0–16.0 mg.L^(-1)detection range)and Cu^(2+)(0.013 mg.L^(-1)detection limit;0.4–12.8 mg.L^(-1)detection range)can be detected simultaneously with high precision.Furthermore,other heavy metal ions and common interfering ions found in groundwater showed negligible impacts on the electrode’s performance,and the recovery rate of groundwater samples varied between 96.3%±2.1%and 109.4%±0.6%.The compactness,flexible shape,low power consumption,and ability to remotely operate our electrode pave the way for onsite detection of heavy metals in groundwater,thereby demonstrating the potential to revolutionize the field of environmental monitoring.
文摘The polypyrrole is the high conductive polymer which was coated onto indium tin oxide (ITO) glass substrate by electroplated technique to fabricate a miniaturized reference electrode.Besides,the morphology of the ITO glass reference electrode electroplated with pyrrole has been studied through the instrumental analysis utilizing cyclic voltammetry (CV). Furthermore,the sensing characteristics of the reference electrode have been measured by using commercial instrumental amplifier as the readout circuit.Using the high conductive polymer as miniaturized reference electrode has many advantages such as easy fabrication of coating polymer,without any expensive fabricating equipment,easy carry by the miniaturized technique.Hence,it is suitable for the reference electrode production.