期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
China Federation of International Mining Capacity Cooperation Enterprises Established
1
《China Nonferrous Metals Monthly》 2017年第10期7-7,共1页
On September 22,the inaugural meeting of the China Federation of International Mining CapacityCooperationEnterprises('Federation')was held in Tianjin.Vice Minister of Land and Resources Cao Weixing attended th... On September 22,the inaugural meeting of the China Federation of International Mining CapacityCooperationEnterprises('Federation')was held in Tianjin.Vice Minister of Land and Resources Cao Weixing attended the meeting and delivered a speech.Heads of the departments and units directly under the National Development and Reform Commission(NDRC)and the Ministry of 展开更多
关键词 China Federation of International mining capacity Cooperation Enterprises Established
原文传递
Vertical load capacities of roof truss cross members
2
作者 Gearhart David F. Mohamed Khaled Morsy 《International Journal of Mining Science and Technology》 SCIE EI CSCD 2016年第3期517-520,共4页
Trusses used for roof support in coal mines are constructed of two grouted bolts installed at opposing forty-five degree angles into the roof and a cross member that ties the angled bolts together. The load on the cro... Trusses used for roof support in coal mines are constructed of two grouted bolts installed at opposing forty-five degree angles into the roof and a cross member that ties the angled bolts together. The load on the cross member is vertical, which is transverse to the longitudinal axis, and therefore the cross member is loaded in the weakest direction. Laboratory tests were conducted to determine the vertical load capacity and deflection of three different types of cross members. Single-point load tests, with the load applied in the center of the specimen and double-point load tests, with a span of 2.4 m, were conducted. For the single-point load configuration, the yield of the 25 mm solid bar cross member was nominally 98 kN of vertical load, achieved at 42 cm of deflection. For cable cross members, yield was not achieved even after 45 cm of deflection. Peak vertical loads were about 89 kN for 17 mm cables and67 kN for the 15 mm cables. For the double-point load configurations, the 25 mm solid bar cross members yielded at 150 kN of vertical load and 25 cm of deflection. At 25 cm of deflection individual cable strands started breaking at 133 and 111 kN of vertical load for the 17 and 15 mm cable cross members respectively. 展开更多
关键词 Roof truss Coal mining Ground control Load capacity Roof support
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部