【目的】明晰地下储气库的热力学过程是压缩空气储能(compressed air energy storage,CAES)电站安全设计与运行调度的重要基础。【方法】现有地下储气库热力学模型在计算热量交换时,存在高压储气阶段热损失偏大和低压储气库阶段补热过...【目的】明晰地下储气库的热力学过程是压缩空气储能(compressed air energy storage,CAES)电站安全设计与运行调度的重要基础。【方法】现有地下储气库热力学模型在计算热量交换时,存在高压储气阶段热损失偏大和低压储气库阶段补热过多的不足。本文在全面分析地下储气库热力学模型理论基础合理性的前提下,先分析储气库热量计算偏差的形成根源;再提出改进模型。【结果】研究结果表明:现有的热力学计算解析模型忽略了CAES地下储气库在运行过程中温度分布的不均匀性,这种温度分布的不均匀导致储气室洞壁与压缩空气之间的对流换热模型失真,导致温度计算结果偏差大。考虑混合对流换热的改进模型二可以较好地解决储气阶段温度计算结果与真实结果之间偏差过大的问题。算例分析证明了改进模型二的合理性。【结论】本文的改进模型二可为CAES地下储气库容积优化设计与效率分析提供计算依据。展开更多
To utilize heat and electricity in a clean and integrated manner,a zero-carbon-emission micro Energy Internet(ZCE-MEI) architecture is proposed by incorporating non-supplementary fired compressed air energy storage(NS...To utilize heat and electricity in a clean and integrated manner,a zero-carbon-emission micro Energy Internet(ZCE-MEI) architecture is proposed by incorporating non-supplementary fired compressed air energy storage(NSF-CAES) hub.A typical ZCE-MEI combining power distribution network(PDN) and district heating network(DHN) with NSF-CAES is considered in this paper.NSF-CAES hub is formulated to take the thermal dynamic and pressure behavior into account to enhance dispatch flexibility.A modified Dist Flow model is utilized to allow several discrete and continuous reactive power compensators to maintain voltage quality of PDN.Optimal operation of the ZCE-MEI is firstly modeled as a mixed integer nonlinear programming(MINLP).Several transformations and simplifications are taken to convert the problem as a mixed integer linear programming(MILP)which can be effectively solved by CPLEX.A typical test system composed of a NSF-CAES hub,a 33-bus PDN,and an 8-node DHN is adopted to verify the effectiveness of the proposed ZCE-MEI in terms of reducing operation cost and wind curtailment.展开更多
文摘【目的】明晰地下储气库的热力学过程是压缩空气储能(compressed air energy storage,CAES)电站安全设计与运行调度的重要基础。【方法】现有地下储气库热力学模型在计算热量交换时,存在高压储气阶段热损失偏大和低压储气库阶段补热过多的不足。本文在全面分析地下储气库热力学模型理论基础合理性的前提下,先分析储气库热量计算偏差的形成根源;再提出改进模型。【结果】研究结果表明:现有的热力学计算解析模型忽略了CAES地下储气库在运行过程中温度分布的不均匀性,这种温度分布的不均匀导致储气室洞壁与压缩空气之间的对流换热模型失真,导致温度计算结果偏差大。考虑混合对流换热的改进模型二可以较好地解决储气阶段温度计算结果与真实结果之间偏差过大的问题。算例分析证明了改进模型二的合理性。【结论】本文的改进模型二可为CAES地下储气库容积优化设计与效率分析提供计算依据。
基金supported in part by the National Natural Science Foundation of China(No.51321005,No.51377092,No.51577163)Opening Foundation of the Qinghai Province Key Laboratory of Photovoltaic Power Generation and Grid-connected Technology
文摘To utilize heat and electricity in a clean and integrated manner,a zero-carbon-emission micro Energy Internet(ZCE-MEI) architecture is proposed by incorporating non-supplementary fired compressed air energy storage(NSF-CAES) hub.A typical ZCE-MEI combining power distribution network(PDN) and district heating network(DHN) with NSF-CAES is considered in this paper.NSF-CAES hub is formulated to take the thermal dynamic and pressure behavior into account to enhance dispatch flexibility.A modified Dist Flow model is utilized to allow several discrete and continuous reactive power compensators to maintain voltage quality of PDN.Optimal operation of the ZCE-MEI is firstly modeled as a mixed integer nonlinear programming(MINLP).Several transformations and simplifications are taken to convert the problem as a mixed integer linear programming(MILP)which can be effectively solved by CPLEX.A typical test system composed of a NSF-CAES hub,a 33-bus PDN,and an 8-node DHN is adopted to verify the effectiveness of the proposed ZCE-MEI in terms of reducing operation cost and wind curtailment.