The Mixed Refrigerant(MR)component is an important factor influencing the performances of natural gas lique-faction processes.However,there is a lack of systematic research about the utilization of propane pre-cooled(...The Mixed Refrigerant(MR)component is an important factor influencing the performances of natural gas lique-faction processes.However,there is a lack of systematic research about the utilization of propane pre-cooled(C3/MRC).In this paper,this mixed refrigerant cycle liquefaction process is simulated using the HYSYS software and the main influential parameters involved in the process are varied to analyze their influence on the liquefaction rate and power consumption.The results show that an effective way for lowering the power consumption of the compressor consists of reducing the flow through the compressor through optimization of the percentage of mixed refrigerant.The power consumption of the compressor in the hybrid refrigeration process is affected by both flow and pressure ratios.Its specific power consumption can be reduced by increasing the flow and decreasing the pressure ratio at the same time.The increase in refrigerant pressure at the high-pressure end can significantly mitigate the energy loss of the heat exchanger and compressor.展开更多
The optimal design of a compression refrigeration system(CRS) with multiple temperature levels is very important to chemical process industries and also represents considerable challenges in process systems engineerin...The optimal design of a compression refrigeration system(CRS) with multiple temperature levels is very important to chemical process industries and also represents considerable challenges in process systems engineering. In this paper, a general methodology for the optimal synthesis of the CRS, which simultaneously integrates CRS and Heat Exchanger Networks(HEN) to minimize the total compressor shaft work consumption based on an MINLP model, has been proposed. The major contribution of this method is in addressing the optimal design of refrigeration cycle with variable refrigeration temperature levels. The method can be used to make major decisions in the CRS design, such as the number of levels, temperature levels, and heat transfer duties. The performance of the developed methodology has been illustrated with a case study of an ethylene CRS in an industrial ethylene plant, and the optimal solution has been examined by rigorous simulations in Aspen Plus to verify its feasibility and consistency.展开更多
Refrigeration system holds an important role in process industries. The optimal synthesis cannot only reduce the energy consumption, but also save the production costs. In this study, a general methodology is develope...Refrigeration system holds an important role in process industries. The optimal synthesis cannot only reduce the energy consumption, but also save the production costs. In this study, a general methodology is developed for the optimal design of refrigeration cycle and heat exchanger network(HEN) simultaneously. Taking the heat integration between the external heat sources/sinks and the refrigeration cycle into consideration, a superstructure with sub-coolers is developed. Through defining logical variables that indicate the relative temperature positions of refrigerant streams after sub-coolers, the synthesis is formulated as a Generalized Disjunctive Programming(GDP) problem based on LP transshipment model, with the target of minimizing the total compressor shaft work in the refrigeration system. The GDP model is then reformulated as a Mixed Integer Nonlinear Programming(MINLP) problem with the aid of binary variables and Big-M Constraint Method. The efficacy of the process synthesis model is demonstrated by a case study of ethylene refrigeration system. The result shows that the optimization can significantly reduce the exergy loss as well as the total compression shaft work.展开更多
基金supported by the Science Development Funding Program of Dongying of China(Grant No.DJ2021006)Science Development Funding Program of Dongying of China(Grant No.DJ2021008).
文摘The Mixed Refrigerant(MR)component is an important factor influencing the performances of natural gas lique-faction processes.However,there is a lack of systematic research about the utilization of propane pre-cooled(C3/MRC).In this paper,this mixed refrigerant cycle liquefaction process is simulated using the HYSYS software and the main influential parameters involved in the process are varied to analyze their influence on the liquefaction rate and power consumption.The results show that an effective way for lowering the power consumption of the compressor consists of reducing the flow through the compressor through optimization of the percentage of mixed refrigerant.The power consumption of the compressor in the hybrid refrigeration process is affected by both flow and pressure ratios.Its specific power consumption can be reduced by increasing the flow and decreasing the pressure ratio at the same time.The increase in refrigerant pressure at the high-pressure end can significantly mitigate the energy loss of the heat exchanger and compressor.
基金Supported by the National Natural Science Foundation of China(21676183)
文摘The optimal design of a compression refrigeration system(CRS) with multiple temperature levels is very important to chemical process industries and also represents considerable challenges in process systems engineering. In this paper, a general methodology for the optimal synthesis of the CRS, which simultaneously integrates CRS and Heat Exchanger Networks(HEN) to minimize the total compressor shaft work consumption based on an MINLP model, has been proposed. The major contribution of this method is in addressing the optimal design of refrigeration cycle with variable refrigeration temperature levels. The method can be used to make major decisions in the CRS design, such as the number of levels, temperature levels, and heat transfer duties. The performance of the developed methodology has been illustrated with a case study of an ethylene CRS in an industrial ethylene plant, and the optimal solution has been examined by rigorous simulations in Aspen Plus to verify its feasibility and consistency.
基金Supported by the National Natural Science Foundation of China(21676183)
文摘Refrigeration system holds an important role in process industries. The optimal synthesis cannot only reduce the energy consumption, but also save the production costs. In this study, a general methodology is developed for the optimal design of refrigeration cycle and heat exchanger network(HEN) simultaneously. Taking the heat integration between the external heat sources/sinks and the refrigeration cycle into consideration, a superstructure with sub-coolers is developed. Through defining logical variables that indicate the relative temperature positions of refrigerant streams after sub-coolers, the synthesis is formulated as a Generalized Disjunctive Programming(GDP) problem based on LP transshipment model, with the target of minimizing the total compressor shaft work in the refrigeration system. The GDP model is then reformulated as a Mixed Integer Nonlinear Programming(MINLP) problem with the aid of binary variables and Big-M Constraint Method. The efficacy of the process synthesis model is demonstrated by a case study of ethylene refrigeration system. The result shows that the optimization can significantly reduce the exergy loss as well as the total compression shaft work.