The terahertz band,a unique segment of the electromagnetic spectrum,is crucial for observing the cold,dark universe and plays a pivotal role in cutting-edge scientific research,including the study of cosmic environmen...The terahertz band,a unique segment of the electromagnetic spectrum,is crucial for observing the cold,dark universe and plays a pivotal role in cutting-edge scientific research,including the study of cosmic environments that support life and imaging black holes.High-sensitivity superconductor–insulator–superconductor(SIS)mixers are essential detectors for terahertz astronomical telescopes and interferometric arrays.Compared to the commonly used classical Nb/AlO_(x)/Nb superconducting tunnel junction,the Nb/AlN/NbN hybrid superconducting tunnel junction has a higher energy gap voltage and can achieve a higher critical current density.This makes it particularly promising for the development of ultra-wideband,high-sensitivity coherent detectors or mixers in various scientific research fields.In this paper,we present a superconducting SIS mixer based on Nb/AlN/NbN parallel-connected twin junctions(PCTJ),which has a bandwidth extending up to490 GHz–720 GHz.The best achieved double-sideband(DSB)noise temperature(sensitivity)is below three times the quantum noise level.展开更多
This work aims to systematically study hydrodynamics and mixing characteristics of non-Newtonian fluid(carboxyl methyl cellulose,CMC)in dual shaft eccentric mixer.Fluid rheology was described by the power law rheologi...This work aims to systematically study hydrodynamics and mixing characteristics of non-Newtonian fluid(carboxyl methyl cellulose,CMC)in dual shaft eccentric mixer.Fluid rheology was described by the power law rheological model.Computational fluid dynamics was employed to simulate the velocity field and shear rate inside the stirred tank.The influence mechanism of the rotational modes,height difference between impellers,impeller eccentricities,and impeller types on the flow field have been well investigated.We studied the performance of different dual-shaft eccentric mixers at the constant power input with its fluid velocity profiles,average shear strain rate,mixing time and mixing energy.The counter-rotation mode shows better mixing performance than co-rotation mode,and greater eccentricity can shorten mixing time on the basis of same stirred condition.To intensify the hydrodynamic interaction between impellers and enhance the overall mixing performance of the dual shaft eccentric mixers,it is critical to have a reasonable combination of impellers and an appropriate spatial position of impellers.展开更多
Numerous studies have been conducted on microfluidic mixers in various microanalysis systems, which elucidated the manipulation and control of small fluid volumes within microfluidic chips. These studies have demonstr...Numerous studies have been conducted on microfluidic mixers in various microanalysis systems, which elucidated the manipulation and control of small fluid volumes within microfluidic chips. These studies have demonstrated the ability to control fluids and samples precisely at the microscale. Microfluidic mixers provide high sensitivity for biochemical analysis due to their small volumes and high surface-to-volume ratios. A promising approach in drug delivery is the rapid microfluidic mixer-based extraction of elemental iodine at the micro level, demonstrating the versatility and the potential to enhance diagnostic imaging and accuracy in targeted drug delivery. Micro-mixing inside microfluidic chips plays a key role in biochemical analysis. The experimental study describes a microfluidic mixer for extraction of elemental iodine using carbon tetrachloride with a gas bubble mixing process. Gas bubbles are generated inside the microcavity to create turbulence and micro-vortices resulting in uniform mixing of samples. The bubble mixing of biochemical samples is analyzed at various pressure levels to validate the simulated results in computational fluid dynamics(CFD). The experimental setup includes a high-resolution camera and an air pump to observe the mixing process and volume at different pressure levels with time. The bubble formation is controlled by adjusting the inert gas flow inside the microfluidic chip. Microfluidic chip-based gas bubble mixing effects have been elaborated at various supplied pressures.展开更多
基金Project supported in part by the National Key Research and Development Program of China(Grant Nos.2023YFA1608201 and 2023YFF0722301)the National Natural Science Foundation of China(Grant Nos.11925304,12020101002,12333013,12273119,and 12103093)supported by grant from the Russian Science Foundation(Grant No.23-7900019)。
文摘The terahertz band,a unique segment of the electromagnetic spectrum,is crucial for observing the cold,dark universe and plays a pivotal role in cutting-edge scientific research,including the study of cosmic environments that support life and imaging black holes.High-sensitivity superconductor–insulator–superconductor(SIS)mixers are essential detectors for terahertz astronomical telescopes and interferometric arrays.Compared to the commonly used classical Nb/AlO_(x)/Nb superconducting tunnel junction,the Nb/AlN/NbN hybrid superconducting tunnel junction has a higher energy gap voltage and can achieve a higher critical current density.This makes it particularly promising for the development of ultra-wideband,high-sensitivity coherent detectors or mixers in various scientific research fields.In this paper,we present a superconducting SIS mixer based on Nb/AlN/NbN parallel-connected twin junctions(PCTJ),which has a bandwidth extending up to490 GHz–720 GHz.The best achieved double-sideband(DSB)noise temperature(sensitivity)is below three times the quantum noise level.
基金supported by the National Natural Science Foundation of China(22078030,52021004)National Natural Science Foundation of Chongqing(2022NSCQ-LZX0271)+2 种基金Fundamental Research Funds for the Central Universities(2022CDJQY-005)National Key Research and Development Project(2019YFC1905802,2022YFC3901204)Key Project of Independent Research Project of State Key Laboratory of coal mine disaster dynamics and control(2011DA105287-zd201902).
文摘This work aims to systematically study hydrodynamics and mixing characteristics of non-Newtonian fluid(carboxyl methyl cellulose,CMC)in dual shaft eccentric mixer.Fluid rheology was described by the power law rheological model.Computational fluid dynamics was employed to simulate the velocity field and shear rate inside the stirred tank.The influence mechanism of the rotational modes,height difference between impellers,impeller eccentricities,and impeller types on the flow field have been well investigated.We studied the performance of different dual-shaft eccentric mixers at the constant power input with its fluid velocity profiles,average shear strain rate,mixing time and mixing energy.The counter-rotation mode shows better mixing performance than co-rotation mode,and greater eccentricity can shorten mixing time on the basis of same stirred condition.To intensify the hydrodynamic interaction between impellers and enhance the overall mixing performance of the dual shaft eccentric mixers,it is critical to have a reasonable combination of impellers and an appropriate spatial position of impellers.
基金Project supported by the National Natural Science Foundation of China (Grant No. 51175101)。
文摘Numerous studies have been conducted on microfluidic mixers in various microanalysis systems, which elucidated the manipulation and control of small fluid volumes within microfluidic chips. These studies have demonstrated the ability to control fluids and samples precisely at the microscale. Microfluidic mixers provide high sensitivity for biochemical analysis due to their small volumes and high surface-to-volume ratios. A promising approach in drug delivery is the rapid microfluidic mixer-based extraction of elemental iodine at the micro level, demonstrating the versatility and the potential to enhance diagnostic imaging and accuracy in targeted drug delivery. Micro-mixing inside microfluidic chips plays a key role in biochemical analysis. The experimental study describes a microfluidic mixer for extraction of elemental iodine using carbon tetrachloride with a gas bubble mixing process. Gas bubbles are generated inside the microcavity to create turbulence and micro-vortices resulting in uniform mixing of samples. The bubble mixing of biochemical samples is analyzed at various pressure levels to validate the simulated results in computational fluid dynamics(CFD). The experimental setup includes a high-resolution camera and an air pump to observe the mixing process and volume at different pressure levels with time. The bubble formation is controlled by adjusting the inert gas flow inside the microfluidic chip. Microfluidic chip-based gas bubble mixing effects have been elaborated at various supplied pressures.