The main ideas in the development of the solvent extraction mixer settler focused on achieving clean phase separation,minimizing the loss of the reagents and decreasing the surface area of the settlers.The role of baf...The main ideas in the development of the solvent extraction mixer settler focused on achieving clean phase separation,minimizing the loss of the reagents and decreasing the surface area of the settlers.The role of baffles in a mechanically agitated vessel is to ensure even distribution,reduce settler turbulence,promote the stability of power drawn by the impeller and to prevent swirling and vortexing of liquid,thus,greatly improving the mixing of liquid.The insertion of the appropriate number of baffles clearly improves the extent of liquid mixing.However,excessive baffling would interrupt liquid mixing and lengthen the mixing time.Computational fluid dynamics(CFD) provides a tool for determining detailed information on fluid flow(hydrodynamics) which is necessary for modeling subprocesses in mixer settler.A total of 54 final CFD runs were carried out representing different combinations of variables like number of baffles,density and impeller speed.CFD data shows that amount of separation increases with increasing baffles number and decreasing impeller speed.展开更多
Drop size distribution(DSD) or mean droplet size(d32) and liquid holdup are two key parameters in a liquid–liquid extraction process. Understanding and accurately predicting those parameters are of great importance i...Drop size distribution(DSD) or mean droplet size(d32) and liquid holdup are two key parameters in a liquid–liquid extraction process. Understanding and accurately predicting those parameters are of great importance in the optimal design of extraction columns as well as mixer–settlers. In this paper, the method of built-in endoscopic probe combined with pulse laser was adopted to measure the droplet size in liquid–liquid dispersions with a pump-impeller in a rectangular mixer. The dispersion law of droplets with holdup range 1% to 24% in batch process and larger flow ratio range 1/5 to 5/1 in continuous process was studied. Under the batch operation condition, the DSD abided by log-normal distribution. With the increase of impeller speed or decrease of dispersed phase holdup, the d32 decreased. In addition, a prediction model of d32 of kerosene/deionized system was established as d32/D = 0.13(1 + 5.9φ)We-0.6. Under the continuous operation condition, the general model for droplet size prediction of kerosene/water system was presented as d32/D = C3(1 + C4φ)We-0.6. For the surfactant system and extraction system, the prediction models met a general model as d32/D = bφnWe-0.6.展开更多
文摘The main ideas in the development of the solvent extraction mixer settler focused on achieving clean phase separation,minimizing the loss of the reagents and decreasing the surface area of the settlers.The role of baffles in a mechanically agitated vessel is to ensure even distribution,reduce settler turbulence,promote the stability of power drawn by the impeller and to prevent swirling and vortexing of liquid,thus,greatly improving the mixing of liquid.The insertion of the appropriate number of baffles clearly improves the extent of liquid mixing.However,excessive baffling would interrupt liquid mixing and lengthen the mixing time.Computational fluid dynamics(CFD) provides a tool for determining detailed information on fluid flow(hydrodynamics) which is necessary for modeling subprocesses in mixer settler.A total of 54 final CFD runs were carried out representing different combinations of variables like number of baffles,density and impeller speed.CFD data shows that amount of separation increases with increasing baffles number and decreasing impeller speed.
基金Supported by the National Natural Science Foundation of China(NSFC)(21636004)the National Safety Academy Foundation(U1530107)the National Basic Research Program of China(2012CBA01203).
文摘Drop size distribution(DSD) or mean droplet size(d32) and liquid holdup are two key parameters in a liquid–liquid extraction process. Understanding and accurately predicting those parameters are of great importance in the optimal design of extraction columns as well as mixer–settlers. In this paper, the method of built-in endoscopic probe combined with pulse laser was adopted to measure the droplet size in liquid–liquid dispersions with a pump-impeller in a rectangular mixer. The dispersion law of droplets with holdup range 1% to 24% in batch process and larger flow ratio range 1/5 to 5/1 in continuous process was studied. Under the batch operation condition, the DSD abided by log-normal distribution. With the increase of impeller speed or decrease of dispersed phase holdup, the d32 decreased. In addition, a prediction model of d32 of kerosene/deionized system was established as d32/D = 0.13(1 + 5.9φ)We-0.6. Under the continuous operation condition, the general model for droplet size prediction of kerosene/water system was presented as d32/D = C3(1 + C4φ)We-0.6. For the surfactant system and extraction system, the prediction models met a general model as d32/D = bφnWe-0.6.