The features of a quasi-two-dimensional( quasi-2D) model for simulating two-phase water hammer flows with vaporous cavity in a pipe are investigated. The quasi-2D model with discrete vaporous cavity in the pipe is pro...The features of a quasi-two-dimensional( quasi-2D) model for simulating two-phase water hammer flows with vaporous cavity in a pipe are investigated. The quasi-2D model with discrete vaporous cavity in the pipe is proposed in this paper. This model uses the quasi-2D model for pure liquid zone and one-dimensional( 1D) discrete vapor cavity model for vaporous cavity zone. The quasi-2D model solves two-dimensional equations for both axial and radial velocities and 1D equations for both pressure head and discharge by the method of characteristics. The 1D discrete vapor cavity model is used to simulate the vaporous cavity occurred when the pressure in the local pipe is lower than the vapor pressure of the liquid. The proposed model is used to simulate two-phase water flows caused by the rapid downstream valve closure in a reservoir-pipe-valve system.The results obtained by the proposed model are compared with those by the corresponding 1D model and the experimental ones provided by the literature,respectively. The comparison shows that the maximum pressure heads simulated by the proposed model are more accurate than those by the corresponding 1D model.展开更多
Purpose of present work is to develop a reliable and simple method for structural analysis of RC Shear Walls. The shear wall is simulated by a truss model as the bar of a truss is the simplest finite element. An itera...Purpose of present work is to develop a reliable and simple method for structural analysis of RC Shear Walls. The shear wall is simulated by a truss model as the bar of a truss is the simplest finite element. An iterative method is used. Initially, there are only concrete bars. Repeated structural analyses are performed. After each structural analysis, every concrete bar exceeding tensile strength is replaced by a steel bar. For every concrete bar exceeding compressive strength, first its section area is increased. If this is not enough, a steel bar is placed at the side of it. For every steel bar exceeding tensile or compressive strength, its section area is increased. After the end of every structural analysis, if all concrete and steel bars fall within tensile and compressive strengths, the output data are written and the analysis is terminated. Otherwise, the structural analysis is repeated. As all the necessary conditions (static, elastic, linearized geometric) are satisfied and the stresses of ALL concrete and steel bars fall within the tensile and compressive strengths, the results are acceptable. Usually, the proposed method exhibits a fast convergence in 4 - 5 repeats of structural analysis of the RC Shear Wall.展开更多
基金Sponsored by the National Natural Science Foundation of China(Grant No.51208160)the Natural Science Foundation of Heilongjiang Province(Grant No.QC2012C056)
文摘The features of a quasi-two-dimensional( quasi-2D) model for simulating two-phase water hammer flows with vaporous cavity in a pipe are investigated. The quasi-2D model with discrete vaporous cavity in the pipe is proposed in this paper. This model uses the quasi-2D model for pure liquid zone and one-dimensional( 1D) discrete vapor cavity model for vaporous cavity zone. The quasi-2D model solves two-dimensional equations for both axial and radial velocities and 1D equations for both pressure head and discharge by the method of characteristics. The 1D discrete vapor cavity model is used to simulate the vaporous cavity occurred when the pressure in the local pipe is lower than the vapor pressure of the liquid. The proposed model is used to simulate two-phase water flows caused by the rapid downstream valve closure in a reservoir-pipe-valve system.The results obtained by the proposed model are compared with those by the corresponding 1D model and the experimental ones provided by the literature,respectively. The comparison shows that the maximum pressure heads simulated by the proposed model are more accurate than those by the corresponding 1D model.
文摘Purpose of present work is to develop a reliable and simple method for structural analysis of RC Shear Walls. The shear wall is simulated by a truss model as the bar of a truss is the simplest finite element. An iterative method is used. Initially, there are only concrete bars. Repeated structural analyses are performed. After each structural analysis, every concrete bar exceeding tensile strength is replaced by a steel bar. For every concrete bar exceeding compressive strength, first its section area is increased. If this is not enough, a steel bar is placed at the side of it. For every steel bar exceeding tensile or compressive strength, its section area is increased. After the end of every structural analysis, if all concrete and steel bars fall within tensile and compressive strengths, the output data are written and the analysis is terminated. Otherwise, the structural analysis is repeated. As all the necessary conditions (static, elastic, linearized geometric) are satisfied and the stresses of ALL concrete and steel bars fall within the tensile and compressive strengths, the results are acceptable. Usually, the proposed method exhibits a fast convergence in 4 - 5 repeats of structural analysis of the RC Shear Wall.