Theoretical and experimental analysis of a new refrigerant mixture BY-3 was conducted based on a single-stage vapor compression refrigeration system. The water-water heat pump system used BY-3 to produce hot water whe...Theoretical and experimental analysis of a new refrigerant mixture BY-3 was conducted based on a single-stage vapor compression refrigeration system. The water-water heat pump system used BY-3 to produce hot water when the low temperature was 20 ℃. The following results were obtained: the highest temperature at the condenser outlet reached about 85 ℃; when the difference between the water temperatures at the condenser outlet and the evaporator inlet was less than 40 ℃, the coefficient of performance (COP) was larger than 4; when the difference reached 55 ℃, the COP still kept 3; the discharge temperature of BY-3 was lower than 100 ℃, and the refrigerant vapor pressure kept lower than 1.8 MPa. When the water temperature at the condenser outlet reached over 85 ℃, nearly a 5 ℃ superheating temperature was maintained.展开更多
A moderate pressure/high temperature zonal metamorphic complex in the Tongulack Mountain Ridge, Altai, Russia, is described, and the applicability of the models of magmatic intrusion and fluid flow to explanation of i...A moderate pressure/high temperature zonal metamorphic complex in the Tongulack Mountain Ridge, Altai, Russia, is described, and the applicability of the models of magmatic intrusion and fluid flow to explanation of its origin discussed. The Precambrian complex was formed at 500–700°C and 3.0–5.5 kbars; it is a linear, 25–30 km wide, thermal anticline with a curved axis showing symmetric metamorphic zoning. The metamorphism was isochemical by its nature, as is corroborated by the chemical compositions of the rocks. Four zones can be recognized within the metamorphic complex: chloritic (on the peripheries), cordieritic, sillimanitic and staurolite-out (in the centre). The zones are separated by successive isograds: cordierite, staurolite-in or sillimanite and staurolite-out. It is argued that the origin of the metamorphic zoning can be explained best by a combined fluid-magmatic model; conductive heat flow from the intrusion predominated considerably over the fluid flux in heat transfer: the fluid flow rate was estimated as about 3 ? 10?9 g/cm2, ? s. The modern position of the axial region of the metamorphic belt is predicted to be lying roughly about 1.5 km above the roof of the intrusive body.展开更多
基金Supported by Major State Basic Research Development Program of China ("973" Program, No. 2009CB219907)the Program for Changjiang Scholars and Innovative Research Team in University (No. IRT0936)
文摘Theoretical and experimental analysis of a new refrigerant mixture BY-3 was conducted based on a single-stage vapor compression refrigeration system. The water-water heat pump system used BY-3 to produce hot water when the low temperature was 20 ℃. The following results were obtained: the highest temperature at the condenser outlet reached about 85 ℃; when the difference between the water temperatures at the condenser outlet and the evaporator inlet was less than 40 ℃, the coefficient of performance (COP) was larger than 4; when the difference reached 55 ℃, the COP still kept 3; the discharge temperature of BY-3 was lower than 100 ℃, and the refrigerant vapor pressure kept lower than 1.8 MPa. When the water temperature at the condenser outlet reached over 85 ℃, nearly a 5 ℃ superheating temperature was maintained.
文摘A moderate pressure/high temperature zonal metamorphic complex in the Tongulack Mountain Ridge, Altai, Russia, is described, and the applicability of the models of magmatic intrusion and fluid flow to explanation of its origin discussed. The Precambrian complex was formed at 500–700°C and 3.0–5.5 kbars; it is a linear, 25–30 km wide, thermal anticline with a curved axis showing symmetric metamorphic zoning. The metamorphism was isochemical by its nature, as is corroborated by the chemical compositions of the rocks. Four zones can be recognized within the metamorphic complex: chloritic (on the peripheries), cordieritic, sillimanitic and staurolite-out (in the centre). The zones are separated by successive isograds: cordierite, staurolite-in or sillimanite and staurolite-out. It is argued that the origin of the metamorphic zoning can be explained best by a combined fluid-magmatic model; conductive heat flow from the intrusion predominated considerably over the fluid flux in heat transfer: the fluid flow rate was estimated as about 3 ? 10?9 g/cm2, ? s. The modern position of the axial region of the metamorphic belt is predicted to be lying roughly about 1.5 km above the roof of the intrusive body.