Modular multilevel converters(MMCs)have been one of the most broadly used multilevel converter topologies in industrial applications,particularly in medium-voltage motor drives and high-voltage dc power conversion sys...Modular multilevel converters(MMCs)have been one of the most broadly used multilevel converter topologies in industrial applications,particularly in medium-voltage motor drives and high-voltage dc power conversion systems.However,due to the utilization of large amount of semiconductor devices,the reliability of MMCs becomes one of the severe challenges constraining their further development and applications.In this paper,common electrical faults of the MMC have been summarized and analyzed,including open-circuit switching faults,short-circuit switching faults,dc-bus short-circuit faults,and single line-to-ground faults on the ac side.A thorough and comprehensive review of the existing online fault diagnostic methods has been conducted.In addition,fault-tolerant operation strategies for such various fault scenarios in MMCs have been presented.All the fault diagnosis and fault-tolerant operation strategies are comparatively evaluated,which aims to provide a state-of-the-art reference on the MMC reliability for future research and industrial applications.展开更多
Modular multilevel resonant converter is an promising candidate for high voltage applications since it has advantageous features,such as high efficiency,high voltage capability and easy fault-tolerant operation.Howeve...Modular multilevel resonant converter is an promising candidate for high voltage applications since it has advantageous features,such as high efficiency,high voltage capability and easy fault-tolerant operation.However,the inequality of arm inductance in practice will lead to imbalance between the upper and lower arm voltages,which will induce large ripples in the circulating current and a dc bias on the voltage generated by modular circuits.To compensate for the voltage imbalance,effects of arm duty cycle changes on arm voltages are discussed.An arm voltage balancing control method is proposed:adjust arm duty cycle according to arm voltage deviation in every switching cycle.Simulation and experimental results are presented to validate the theoretical analysis and the proposed control method.展开更多
The modular multilevel converter(MMC)has become a promising topology for widespread power converter applications.However,an evident circulating current flowing between the phases will increase system losses and compli...The modular multilevel converter(MMC)has become a promising topology for widespread power converter applications.However,an evident circulating current flowing between the phases will increase system losses and complicate the heatsink design.This paper proposes a novel hybrid model predictive control method for MMCs.This method utilizes an indirect structure MPC and a sorting algorithm to implement current tracking and capacitor voltages balancing,considerably resulting in reduced calculation burden.In addition,different from the conventional MPC solutions,we add a simple proportional-integral(PI)controller to suppress circulating current through modifying the submodule(SM)inserted number,which is parallel to the MPC loop.This hybrid control solution combines both advantages of MPC and linear control,evidently resulting in improved performance of circulating current.Finally,the MATLAB/Simulink results of an 11-level MMC system verify the effectiveness of the proposed solution.展开更多
Solid state transformer(SST)can provide more advanced functionalities compared with conventional transformer,and has great potential in smart grid application.Recently,the SST with medium frequency(MF)isolation link a...Solid state transformer(SST)can provide more advanced functionalities compared with conventional transformer,and has great potential in smart grid application.Recently,the SST with medium frequency(MF)isolation link and magnetic integration feature has been proposed,which can reduce the system volume and thus increase the power density.However,the magnetic integration also introduces strong coupling between the line frequency(LF)and MF variables,which poses a great challenge on modeling and control issues.This paper proposes a modeling and control method for an SST with magnetic integration and mixed-frequency modulation.A mathematical model based on dual d-q references is deduced,and then a cascaded control system is designed according to the model.Parameters of the controller for the variables at one frequency are properly designed to avoid disturbance from the variables at the other frequency.The simulation and experimental results show good decoupling effect and satisfactory dynamics performance of the proposed control system.展开更多
A modular multilevel converter(MMC)integrated with split battery cells(BIMMCs)is proposed for the battery management system(BMS)and motor drive system.In order to reduce the switching losses,the state of charge(SOC)ba...A modular multilevel converter(MMC)integrated with split battery cells(BIMMCs)is proposed for the battery management system(BMS)and motor drive system.In order to reduce the switching losses,the state of charge(SOC)balancing strategy with a reduced switching-frequency(RSF)is proposed in this paper.The proposed RSF algorithm not only reduces the switching losses,but also features good balancing performance both in the unbalanced and balanced initial states.The results are verified by extensive simulations in MATLAB/Simulink surroundings.展开更多
This paper presents a new modular multilevel converter (MMC) topology. Compared to conventional multilevel converters, MMC has much lower switching frequency (50 Hz) resulting in lower switching losses, and consequent...This paper presents a new modular multilevel converter (MMC) topology. Compared to conventional multilevel converters, MMC has much lower switching frequency (50 Hz) resulting in lower switching losses, and consequently, lower total losses of the transmission system. The fundamental concept and the applied control scheme are introduced in detail. A modified multilevel fundamental switching modulation scheme adopting the multicarrier pulse width modulation concept is presented. A capacitor voltage balancing technique is proposed. With the established simulation model of the 11-level MMC, the modulation and balancing strategy presented are confirmed by MATLAB/SIMULINK simulations. The multicarrier pulse width modulation converter strategy enhances the fundamental output voltage and reduces total harmonic distortion. This new type of converter is suitable for high-voltage drive systems and power system applications such as high voltage dc (HVDC) transmission, reactive power compensation equipment and so on.展开更多
In this paper, a novel voltage balancing method of modular multilevel converters (MMCs) is proposed. This method divides the voltages of sub-module capacitors in each arm into several groups and the voltage balancing ...In this paper, a novel voltage balancing method of modular multilevel converters (MMCs) is proposed. This method divides the voltages of sub-module capacitors in each arm into several groups and the voltage balancing is based on these groups. The proposed method can save sorting time greatly compared with the conventional method. Simulation results on a MMC based three-phase inverter show validity of the proposed method.展开更多
The stop control strategy of modular multilevel converter based HVDC transmission system is proposed. This stop process is divided into stages of energy feedback and energy consumption. The DC voltage controller is co...The stop control strategy of modular multilevel converter based HVDC transmission system is proposed. This stop process is divided into stages of energy feedback and energy consumption. The DC voltage controller is coordinated to the used modules per phase when active power is transmitted prior to reactive power, so that the energy is fed back to the AC power grid connected to the converter station which uses the fixed dc voltage controller. In addition, in view of the different forms connected to the grid, specifically when the converter station supplies power for passive network, the passive converter station can take a certain auxiliary trigger strategy to make its maximum energy feedback to the grid. Finally, a simulation system of the MMC-HVDC system is constructed in Matlab/Simulink environment, and simulation results show that the proposed stop strategies are effective.展开更多
A novel DC traction power supply system suitable for energy feeding and de-icing is proposed in this paper for an urban rail transit catenary on the basis of the full bridge submodule (FBSM) modular multilevel convert...A novel DC traction power supply system suitable for energy feeding and de-icing is proposed in this paper for an urban rail transit catenary on the basis of the full bridge submodule (FBSM) modular multilevel converter (MMC). The FBSM-MMC is a novel type of voltage source converter (VSC) and can directly control the output DC voltage and conduct bipolar currents, thus flexibly controlling the power flow of the urban rail transit catenary. The proposed topology can overcome the inherent disadvantages of the output voltage drop in the diode rectifier units, increase the power supply distance and reduce the number of traction substations. The flexible DC technology can coordinate multiple FBSM-MMCs in a wide area and jointly complete the bidirectional control of catenary power flow during the operation of the electric locomotive, so as to realize the local consumption and optimal utilization of the recovered braking energy of the train. In addition, the FBSM-MMCs can also adjust the output current when the locomotive is out of service to prevent the catenary from icing in winter. The working modes of the proposed topology are illustrated in detail and the control strategy is specially designed for normal locomotive operations and catenary de-icing. Simulation cases conducted by PSCAD/EMTDC validate the proposed topology and its control strategy.展开更多
Dead time is necessary for the coupled power switches to prevent shoot-through,especially in the modular multilevel converters(MMCs)with a large number of power switches.This paper proposes a dead-time effect suppress...Dead time is necessary for the coupled power switches to prevent shoot-through,especially in the modular multilevel converters(MMCs)with a large number of power switches.This paper proposes a dead-time effect suppression strategy for MMCs with nearest level modulation.The operational principles of MMCs are first analyzed.According to the operational features of MMCs,the method that removes a switching signal from the coupled switches and the reduced switching frequency voltage balancing algorithms(RSFVBAs)are mixed in the proposed method.In the intervals that are furthest away from the zerocrossing points(ZCP)of arm currents,the single switching signal method can completely eliminate the dead-time effect(DTE).Alternatively,the DTE is suppressed by the RSFVBA in intervals that are close to the ZCP.By the combination of the two methods,the dependence of the DTE suppression method on currents is reduced and the influences of ZCP are also released without degrading the normal operation performance of MMCs.Moreover,the output performance of MMCs is improved and the voltage stress on the arm inductor dramatically decreases.Finally,the validation of the method is verified by the simulation results with the professional tool Matlab/Simulink.展开更多
The modular multilevel matrix converter(M3C)is a potential frequency converter for low-frequency AC transmission.However,capacitor voltage control of high-voltage and largecapacity M3C is more difficult,especially for...The modular multilevel matrix converter(M3C)is a potential frequency converter for low-frequency AC transmission.However,capacitor voltage control of high-voltage and largecapacity M3C is more difficult,especially for voltage balancing between branches.To solve this problem,this paper defines sequence circulating components and theoretically analyzes the influence mechanism of different sequence circulating components on branch capacitor voltage.A fully decoupled branch energy balancing control method based on four groups of sequence circulating components is proposed.This method can control capacitor voltages of nine branches in horizontal,vertical and diagonal directions.Considering influences of both circulating current and voltage,a cross decoupled control is designed to improve control precision.Simulation results are taken from a low-frequency transmission system based on PSCAD/EMTDC,and effectiveness and precision of the proposed branch energy balancing control method are verified in the case of nonuniform parameters and an unbalanced power system.展开更多
Due to the large number of submodules(SMs),and modular multilevel converters(MMCs)in high-voltage applications,they are usually regulated by the nearest level modulation(NLM).Moreover,the large number of SMs causes a ...Due to the large number of submodules(SMs),and modular multilevel converters(MMCs)in high-voltage applications,they are usually regulated by the nearest level modulation(NLM).Moreover,the large number of SMs causes a challenge for the fault diagnosis strategy(FDS).This paper proposes a currentless FDS for MMC with NLM.In FDS,the voltage sensor is relocated to measure the output voltage of the SM.To acquire the capacitor voltage and avoid increasing extra sensors,a capacitor voltage calculation method is proposed.Based on the measurement of output voltages,the faults can be detected and the number of different-type switch open-circuit faults can be confirmed from the numerous SMs in an arm,which narrows the scope of fault localization.Then,the faulty SMs and faulty switches in these SMs are further located without arm current according to the sorting of capacitor voltages in the voltage balancing algorithm.The FDS is independent of the arm current,which can reduce the communication cost in the hierarchical control system of MMC.Furthermore,the proposed FDS not only simplifies the identification of switch open-circuit faults by confirming the scope of faults,but also detects and locates multiple different-type faults in an arm.The effectiveness of the proposed strategy is verified by the simulation results.展开更多
Grid-forming control(GFC)is promising for power electronics based power systems with high renewable energy penetration.Naturally,the impedance modeling for GFC is necessary and has gained significant attention recentl...Grid-forming control(GFC)is promising for power electronics based power systems with high renewable energy penetration.Naturally,the impedance modeling for GFC is necessary and has gained significant attention recently.However,most of the impedance analyses for GFC are based on a twolevel converter(TLC)rather than a modular multilevel converter(MMC).MMC differs from TLC with respect to its dominant multi-frequency response.It is necessary to analyze the impedance of GFC-based MMC owing to its superiority in highvoltage direct current(HVDC)transmission to interlink two weak AC systems with high renewable energy penetration.As the main contribution,this paper presents the AC-and DC-side impedance analyses for the GFC-based MMC with both power and DC voltage control using the harmonic transfer function(HTF),and compares the impedances of GFC-based MMC and TLC.It is inferred that although the impedance is mainly influenced within 200 Hz,the instability still could occur owing to negative resistance triggered by relatively larger parameters.The difference in AC-side impedance with power and DC voltage control is not apparent with proper parameters,while the DC-side impedance differs significantly.The generalized Nyquist criterion is necessary for AC-side stability owing to the relatively large coupling terms under GFC.Moreover,the coupling between AC-and DC-side impedances is noneligible,especially considering the DC-side resonance around the system resonant peak.The effects of parameters,system strength,and virtual impedance on the impedance shaping are analyzed and verified through simulations.展开更多
The modular multilevel converter(MMC)is a promising topology for medium-voltage drive applications due to its high-quality output waveforms,low device switching frequency and voltage rating.However,the large cell capa...The modular multilevel converter(MMC)is a promising topology for medium-voltage drive applications due to its high-quality output waveforms,low device switching frequency and voltage rating.However,the large cell capacitor voltage ripple is a severe challenge faced by MMC at low motor speeds.Recently,a hybrid MMC(HMMC)topology is proven to be a competitive solution because of its lower cell capacitor voltage ripple and not demonstrating a common-mode voltage(CMV)problem compared with other methods.However,the DC-link switch with IGBT limits HMMC from being applied in highvoltage applications.This paper uses a thyristor instead of IGBT as the DC-link switch.To ensure the thyristor can be softly turned on and safely turned off,a new control scheme is proposed.When using this proposed scheme,HMMC can also tolerate the failure of the thyristor being turned-off without shutting down the system,effectively improving its reliability.The cell capacitor voltage ripple analysis is presented considering the effects of the thyristor switching process.In addition,a decoupled energy balancing control is utilized to suppress the fluctuation of the DC current.Experimental results obtained from a 380 V/7.5 kW downscaled prototype validate the effectiveness of starting up a motor from the standby mode to rated speed applying full-torque.展开更多
This paper proposes a single-ended fault detection scheme for long transmission lines using support vector machine(SVM)for multi-terminal direct current systems based on modular multilevel converter(MMC-MTDC).The sche...This paper proposes a single-ended fault detection scheme for long transmission lines using support vector machine(SVM)for multi-terminal direct current systems based on modular multilevel converter(MMC-MTDC).The scheme overcomes existing detection difficulties in the protection of long transmission lines resulting from high grounding resistance and attenuation,and also avoids the sophisticated process of threshold value selection.The high-frequency components in the measured voltage extracted by a wavelet transform and the amplitude of the zero-mode set of the positive-sequence voltage are the inputs to a trained SVM.The output of the SVM determines the fault type.A model of a four-terminal DC power grid with overhead transmission lines is built in PSCAD/EMTDC.Simulation results of EMTDC confirm that the proposed scheme achieves 100%accuracy in detecting short-circuit faults with high resistance on long transmission lines.The proposed scheme eliminates mal-operation of DC circuit breakers when faced with power order changes or AC-side faults.Its robustness and time delay are also assessed and shown to have no perceptible effect on the speed and accuracy of the detection scheme,thus ensuring its reliability and stability.展开更多
The modular multilevel converters(MMCs) are popularly used in high-voltage direct current(HVDC) transmission systems. However, for the direct modulation based MMC, its complex internal dynamics and the interaction wit...The modular multilevel converters(MMCs) are popularly used in high-voltage direct current(HVDC) transmission systems. However, for the direct modulation based MMC, its complex internal dynamics and the interaction with the grid impedance would induce the frequency coupling effect, which may lead to instability issues, especially in the case of weak grid. To effectively suppress the sub-and super-synchronous oscillations, this paper proposes a linear active disturbance rejection control(LADRC) based MMC control strategy. The LADRC mainly consists of the linear extended state observer(LESO) and the linear state error feedback(LSEF). And it is a potential method to enhance the system stability margin, attributing to its high anti-interference capability and good tracking performance. Thereupon, the system small-signal impedance model considering frequency coupling is established. And the effect of the introduction of the LADRC on the system stability is further investigated using the Nyquist criterion. Particularly, the influences of key control parameters on the stability are discussed in detail. Meanwhile, the impact of LADRC on the transient performance is explored through closed-loop zero poles. Finally, the correctness of the theoretical analysis and the effectiveness of the proposed control strategy are verified via electromagnetic simulations.展开更多
Non-isolated DC/DC converter based on modular multilevel converter(MMC)technology is expected to play an important role in future DC transmission grids.This paper presents a phasor analytical model for this new family...Non-isolated DC/DC converter based on modular multilevel converter(MMC)technology is expected to play an important role in future DC transmission grids.This paper presents a phasor analytical model for this new family of converters which is suitable for a range of studies like DC grid power flow or DC/DC parametric design.The 30th-order phasor model is derived in 3 coordinate frames:zero sequence(DC),fundamental frequency(dq),and double frequency(d2q2).The second-harmonic current suppression control is included as an option.Additionally,an estimation of the required control signals is presented,and a closed-loop model is developed which facilitates direct calculation of all variables and fast parametric studies.The accuracy of the proposed models is verified against a detailed PSCAD model for a wide range of parameters.The studies illustrate the importance of the second-harmonic components on the model accuracy.Finally,the impact of the converter parameters on the performance is studied,and a basic eigenvalue stability analysis is given.展开更多
文摘Modular multilevel converters(MMCs)have been one of the most broadly used multilevel converter topologies in industrial applications,particularly in medium-voltage motor drives and high-voltage dc power conversion systems.However,due to the utilization of large amount of semiconductor devices,the reliability of MMCs becomes one of the severe challenges constraining their further development and applications.In this paper,common electrical faults of the MMC have been summarized and analyzed,including open-circuit switching faults,short-circuit switching faults,dc-bus short-circuit faults,and single line-to-ground faults on the ac side.A thorough and comprehensive review of the existing online fault diagnostic methods has been conducted.In addition,fault-tolerant operation strategies for such various fault scenarios in MMCs have been presented.All the fault diagnosis and fault-tolerant operation strategies are comparatively evaluated,which aims to provide a state-of-the-art reference on the MMC reliability for future research and industrial applications.
基金the National Key Research and Development Program of China(No.2016YFB0100603)National Natural Science Foundation of China(No.51877193)。
文摘Modular multilevel resonant converter is an promising candidate for high voltage applications since it has advantageous features,such as high efficiency,high voltage capability and easy fault-tolerant operation.However,the inequality of arm inductance in practice will lead to imbalance between the upper and lower arm voltages,which will induce large ripples in the circulating current and a dc bias on the voltage generated by modular circuits.To compensate for the voltage imbalance,effects of arm duty cycle changes on arm voltages are discussed.An arm voltage balancing control method is proposed:adjust arm duty cycle according to arm voltage deviation in every switching cycle.Simulation and experimental results are presented to validate the theoretical analysis and the proposed control method.
基金This work was partially supported by the National Natural Science Foundation of China(11847104)General Program of National Natural Science Foundation of China(51977124)+2 种基金Shandong Natural Science Foundation(ZR2019QEE001)Natural Science Foundation of Jiangsu Province(BK20190204)National Distinguished Expert(Youth Talent)Program of China(31390089963058)。
文摘The modular multilevel converter(MMC)has become a promising topology for widespread power converter applications.However,an evident circulating current flowing between the phases will increase system losses and complicate the heatsink design.This paper proposes a novel hybrid model predictive control method for MMCs.This method utilizes an indirect structure MPC and a sorting algorithm to implement current tracking and capacitor voltages balancing,considerably resulting in reduced calculation burden.In addition,different from the conventional MPC solutions,we add a simple proportional-integral(PI)controller to suppress circulating current through modifying the submodule(SM)inserted number,which is parallel to the MPC loop.This hybrid control solution combines both advantages of MPC and linear control,evidently resulting in improved performance of circulating current.Finally,the MATLAB/Simulink results of an 11-level MMC system verify the effectiveness of the proposed solution.
基金the National Natural Science Foundation of China under Grant 51777085.
文摘Solid state transformer(SST)can provide more advanced functionalities compared with conventional transformer,and has great potential in smart grid application.Recently,the SST with medium frequency(MF)isolation link and magnetic integration feature has been proposed,which can reduce the system volume and thus increase the power density.However,the magnetic integration also introduces strong coupling between the line frequency(LF)and MF variables,which poses a great challenge on modeling and control issues.This paper proposes a modeling and control method for an SST with magnetic integration and mixed-frequency modulation.A mathematical model based on dual d-q references is deduced,and then a cascaded control system is designed according to the model.Parameters of the controller for the variables at one frequency are properly designed to avoid disturbance from the variables at the other frequency.The simulation and experimental results show good decoupling effect and satisfactory dynamics performance of the proposed control system.
文摘A modular multilevel converter(MMC)integrated with split battery cells(BIMMCs)is proposed for the battery management system(BMS)and motor drive system.In order to reduce the switching losses,the state of charge(SOC)balancing strategy with a reduced switching-frequency(RSF)is proposed in this paper.The proposed RSF algorithm not only reduces the switching losses,but also features good balancing performance both in the unbalanced and balanced initial states.The results are verified by extensive simulations in MATLAB/Simulink surroundings.
文摘This paper presents a new modular multilevel converter (MMC) topology. Compared to conventional multilevel converters, MMC has much lower switching frequency (50 Hz) resulting in lower switching losses, and consequently, lower total losses of the transmission system. The fundamental concept and the applied control scheme are introduced in detail. A modified multilevel fundamental switching modulation scheme adopting the multicarrier pulse width modulation concept is presented. A capacitor voltage balancing technique is proposed. With the established simulation model of the 11-level MMC, the modulation and balancing strategy presented are confirmed by MATLAB/SIMULINK simulations. The multicarrier pulse width modulation converter strategy enhances the fundamental output voltage and reduces total harmonic distortion. This new type of converter is suitable for high-voltage drive systems and power system applications such as high voltage dc (HVDC) transmission, reactive power compensation equipment and so on.
文摘In this paper, a novel voltage balancing method of modular multilevel converters (MMCs) is proposed. This method divides the voltages of sub-module capacitors in each arm into several groups and the voltage balancing is based on these groups. The proposed method can save sorting time greatly compared with the conventional method. Simulation results on a MMC based three-phase inverter show validity of the proposed method.
文摘The stop control strategy of modular multilevel converter based HVDC transmission system is proposed. This stop process is divided into stages of energy feedback and energy consumption. The DC voltage controller is coordinated to the used modules per phase when active power is transmitted prior to reactive power, so that the energy is fed back to the AC power grid connected to the converter station which uses the fixed dc voltage controller. In addition, in view of the different forms connected to the grid, specifically when the converter station supplies power for passive network, the passive converter station can take a certain auxiliary trigger strategy to make its maximum energy feedback to the grid. Finally, a simulation system of the MMC-HVDC system is constructed in Matlab/Simulink environment, and simulation results show that the proposed stop strategies are effective.
基金supported in part by National Key Research and Development Program of China(2017YFB1200801)Continuous Co-phase Traction Power System based on Static Power Converter(20192001148).
文摘A novel DC traction power supply system suitable for energy feeding and de-icing is proposed in this paper for an urban rail transit catenary on the basis of the full bridge submodule (FBSM) modular multilevel converter (MMC). The FBSM-MMC is a novel type of voltage source converter (VSC) and can directly control the output DC voltage and conduct bipolar currents, thus flexibly controlling the power flow of the urban rail transit catenary. The proposed topology can overcome the inherent disadvantages of the output voltage drop in the diode rectifier units, increase the power supply distance and reduce the number of traction substations. The flexible DC technology can coordinate multiple FBSM-MMCs in a wide area and jointly complete the bidirectional control of catenary power flow during the operation of the electric locomotive, so as to realize the local consumption and optimal utilization of the recovered braking energy of the train. In addition, the FBSM-MMCs can also adjust the output current when the locomotive is out of service to prevent the catenary from icing in winter. The working modes of the proposed topology are illustrated in detail and the control strategy is specially designed for normal locomotive operations and catenary de-icing. Simulation cases conducted by PSCAD/EMTDC validate the proposed topology and its control strategy.
基金supported by the State Key Laboratory of Advanced Power Transmission Technology(GEIRI-SKL-2020-011)。
文摘Dead time is necessary for the coupled power switches to prevent shoot-through,especially in the modular multilevel converters(MMCs)with a large number of power switches.This paper proposes a dead-time effect suppression strategy for MMCs with nearest level modulation.The operational principles of MMCs are first analyzed.According to the operational features of MMCs,the method that removes a switching signal from the coupled switches and the reduced switching frequency voltage balancing algorithms(RSFVBAs)are mixed in the proposed method.In the intervals that are furthest away from the zerocrossing points(ZCP)of arm currents,the single switching signal method can completely eliminate the dead-time effect(DTE).Alternatively,the DTE is suppressed by the RSFVBA in intervals that are close to the ZCP.By the combination of the two methods,the dependence of the DTE suppression method on currents is reduced and the influences of ZCP are also released without degrading the normal operation performance of MMCs.Moreover,the output performance of MMCs is improved and the voltage stress on the arm inductor dramatically decreases.Finally,the validation of the method is verified by the simulation results with the professional tool Matlab/Simulink.
基金supported by National Key R&D Program of China(No.2021YFB2401100).
文摘The modular multilevel matrix converter(M3C)is a potential frequency converter for low-frequency AC transmission.However,capacitor voltage control of high-voltage and largecapacity M3C is more difficult,especially for voltage balancing between branches.To solve this problem,this paper defines sequence circulating components and theoretically analyzes the influence mechanism of different sequence circulating components on branch capacitor voltage.A fully decoupled branch energy balancing control method based on four groups of sequence circulating components is proposed.This method can control capacitor voltages of nine branches in horizontal,vertical and diagonal directions.Considering influences of both circulating current and voltage,a cross decoupled control is designed to improve control precision.Simulation results are taken from a low-frequency transmission system based on PSCAD/EMTDC,and effectiveness and precision of the proposed branch energy balancing control method are verified in the case of nonuniform parameters and an unbalanced power system.
基金supported by the State Key Laboratory of Advanced Power Transmission Technology(GEIRI-SKL-2020-011)。
文摘Due to the large number of submodules(SMs),and modular multilevel converters(MMCs)in high-voltage applications,they are usually regulated by the nearest level modulation(NLM).Moreover,the large number of SMs causes a challenge for the fault diagnosis strategy(FDS).This paper proposes a currentless FDS for MMC with NLM.In FDS,the voltage sensor is relocated to measure the output voltage of the SM.To acquire the capacitor voltage and avoid increasing extra sensors,a capacitor voltage calculation method is proposed.Based on the measurement of output voltages,the faults can be detected and the number of different-type switch open-circuit faults can be confirmed from the numerous SMs in an arm,which narrows the scope of fault localization.Then,the faulty SMs and faulty switches in these SMs are further located without arm current according to the sorting of capacitor voltages in the voltage balancing algorithm.The FDS is independent of the arm current,which can reduce the communication cost in the hierarchical control system of MMC.Furthermore,the proposed FDS not only simplifies the identification of switch open-circuit faults by confirming the scope of faults,but also detects and locates multiple different-type faults in an arm.The effectiveness of the proposed strategy is verified by the simulation results.
基金supported by the State Grid Corporation Science and Technology Project(No.5100-202158335A-0-0-00).
文摘Grid-forming control(GFC)is promising for power electronics based power systems with high renewable energy penetration.Naturally,the impedance modeling for GFC is necessary and has gained significant attention recently.However,most of the impedance analyses for GFC are based on a twolevel converter(TLC)rather than a modular multilevel converter(MMC).MMC differs from TLC with respect to its dominant multi-frequency response.It is necessary to analyze the impedance of GFC-based MMC owing to its superiority in highvoltage direct current(HVDC)transmission to interlink two weak AC systems with high renewable energy penetration.As the main contribution,this paper presents the AC-and DC-side impedance analyses for the GFC-based MMC with both power and DC voltage control using the harmonic transfer function(HTF),and compares the impedances of GFC-based MMC and TLC.It is inferred that although the impedance is mainly influenced within 200 Hz,the instability still could occur owing to negative resistance triggered by relatively larger parameters.The difference in AC-side impedance with power and DC voltage control is not apparent with proper parameters,while the DC-side impedance differs significantly.The generalized Nyquist criterion is necessary for AC-side stability owing to the relatively large coupling terms under GFC.Moreover,the coupling between AC-and DC-side impedances is noneligible,especially considering the DC-side resonance around the system resonant peak.The effects of parameters,system strength,and virtual impedance on the impedance shaping are analyzed and verified through simulations.
基金This work was supported by the National Natural Science Foundation of China under Grant 51720105008 and 52177173。
文摘The modular multilevel converter(MMC)is a promising topology for medium-voltage drive applications due to its high-quality output waveforms,low device switching frequency and voltage rating.However,the large cell capacitor voltage ripple is a severe challenge faced by MMC at low motor speeds.Recently,a hybrid MMC(HMMC)topology is proven to be a competitive solution because of its lower cell capacitor voltage ripple and not demonstrating a common-mode voltage(CMV)problem compared with other methods.However,the DC-link switch with IGBT limits HMMC from being applied in highvoltage applications.This paper uses a thyristor instead of IGBT as the DC-link switch.To ensure the thyristor can be softly turned on and safely turned off,a new control scheme is proposed.When using this proposed scheme,HMMC can also tolerate the failure of the thyristor being turned-off without shutting down the system,effectively improving its reliability.The cell capacitor voltage ripple analysis is presented considering the effects of the thyristor switching process.In addition,a decoupled energy balancing control is utilized to suppress the fluctuation of the DC current.Experimental results obtained from a 380 V/7.5 kW downscaled prototype validate the effectiveness of starting up a motor from the standby mode to rated speed applying full-torque.
文摘This paper proposes a single-ended fault detection scheme for long transmission lines using support vector machine(SVM)for multi-terminal direct current systems based on modular multilevel converter(MMC-MTDC).The scheme overcomes existing detection difficulties in the protection of long transmission lines resulting from high grounding resistance and attenuation,and also avoids the sophisticated process of threshold value selection.The high-frequency components in the measured voltage extracted by a wavelet transform and the amplitude of the zero-mode set of the positive-sequence voltage are the inputs to a trained SVM.The output of the SVM determines the fault type.A model of a four-terminal DC power grid with overhead transmission lines is built in PSCAD/EMTDC.Simulation results of EMTDC confirm that the proposed scheme achieves 100%accuracy in detecting short-circuit faults with high resistance on long transmission lines.The proposed scheme eliminates mal-operation of DC circuit breakers when faced with power order changes or AC-side faults.Its robustness and time delay are also assessed and shown to have no perceptible effect on the speed and accuracy of the detection scheme,thus ensuring its reliability and stability.
基金supported in part by the National Natural Science Foundation of China (No.52077222)in part by the Natural Science Foundation of Shandong Province (No.ZR2020ME202)。
文摘The modular multilevel converters(MMCs) are popularly used in high-voltage direct current(HVDC) transmission systems. However, for the direct modulation based MMC, its complex internal dynamics and the interaction with the grid impedance would induce the frequency coupling effect, which may lead to instability issues, especially in the case of weak grid. To effectively suppress the sub-and super-synchronous oscillations, this paper proposes a linear active disturbance rejection control(LADRC) based MMC control strategy. The LADRC mainly consists of the linear extended state observer(LESO) and the linear state error feedback(LSEF). And it is a potential method to enhance the system stability margin, attributing to its high anti-interference capability and good tracking performance. Thereupon, the system small-signal impedance model considering frequency coupling is established. And the effect of the introduction of the LADRC on the system stability is further investigated using the Nyquist criterion. Particularly, the influences of key control parameters on the stability are discussed in detail. Meanwhile, the impact of LADRC on the transient performance is explored through closed-loop zero poles. Finally, the correctness of the theoretical analysis and the effectiveness of the proposed control strategy are verified via electromagnetic simulations.
文摘Non-isolated DC/DC converter based on modular multilevel converter(MMC)technology is expected to play an important role in future DC transmission grids.This paper presents a phasor analytical model for this new family of converters which is suitable for a range of studies like DC grid power flow or DC/DC parametric design.The 30th-order phasor model is derived in 3 coordinate frames:zero sequence(DC),fundamental frequency(dq),and double frequency(d2q2).The second-harmonic current suppression control is included as an option.Additionally,an estimation of the required control signals is presented,and a closed-loop model is developed which facilitates direct calculation of all variables and fast parametric studies.The accuracy of the proposed models is verified against a detailed PSCAD model for a wide range of parameters.The studies illustrate the importance of the second-harmonic components on the model accuracy.Finally,the impact of the converter parameters on the performance is studied,and a basic eigenvalue stability analysis is given.