The microstructures of conch shell were observed with scanning electronic microscope (SEM), and a kind of inclined-cross microstructure of aragonite sheets was found. The maximal pull-out force of the inclined-cros...The microstructures of conch shell were observed with scanning electronic microscope (SEM), and a kind of inclined-cross microstructure of aragonite sheets was found. The maximal pull-out force of the inclined-cross microstructure was analyzed based on its representative model and compared with that of a conventional 0 °- structure. The experimental result indicates that the maximal pull-out force of the inclined-cross microstructure is markedly larger than that of the 0°- structure.展开更多
Suction caissons have been widely used as anchors and foundations for floating and fixed offshore platforms. The pull-out performance of conventional suction caissons (with upright walls) has been investigated by a ...Suction caissons have been widely used as anchors and foundations for floating and fixed offshore platforms. The pull-out performance of conventional suction caissons (with upright walls) has been investigated by a number of researchers. However, no attention has been paid to tapered suction caissons. This paper deals with the performance of tapered suction caissons under vertical pull-out loads. A numerical approach is used for this purpose. The numerical model is first verified against test data available for common upright caissons. The verified model is then used to study the pullout performance of tapered suction caissons. It is noticed that the pull-out capacities exhibited by tapered suction caissons are in general considerably higher than those from their corresponding traditional upright caissons. To obtain an insight into this superior behaviour, effects from certain soil/caisson/drainage parameters on the pull-out capacity of tapered suction caissons are studied. Soil cohesion is noticed to have a linear improving effect on the capacity of both upright and ta- pered suction caissons. The soil internal friction angle is noticed to have an exponential increasing effect on the pull-out capacity. With a constant caisson diameter, an increase in the aspect ratio is seen to particularly influence the pull-out capacity. With a constant caisson length, an increase in the aspect ratio is discovered to result in non-linear decrease in the pull-out capacity. Under undrained conditions, tapered models generally show less sensitivity to above mentioned soil/caisson parameters as compared with those under drained conditions.展开更多
针对传统电缆舞动检测器在面对电磁干扰和持续供电时灵敏度低、信噪比差、安装复杂和需额外供电等问题,提出一种新型双端Mach-Zehnder(M-Z)电缆扰动监测系统.该系统采用双端光纤M-Z光路结构,可实现长距离、大尺度、多维度的在线监测和...针对传统电缆舞动检测器在面对电磁干扰和持续供电时灵敏度低、信噪比差、安装复杂和需额外供电等问题,提出一种新型双端Mach-Zehnder(M-Z)电缆扰动监测系统.该系统采用双端光纤M-Z光路结构,可实现长距离、大尺度、多维度的在线监测和结构安全预警,从而实时定位舞动位置.该系统的检波器力学单元采用硅胶弹性体和黄铜质量块推挽式结构,经ANSYS软件进行参数化建模和有限元分析后,得出其固有频率为106.77 Hz,与实验所测数据的相对误差仅为1.65%.实验结果表明,该检测器在0~140 Hz内的相对灵敏度为41.25~66.78 dB (rad/Pa),对舞动信号具有较高灵敏度的检测能力.展开更多
文摘The microstructures of conch shell were observed with scanning electronic microscope (SEM), and a kind of inclined-cross microstructure of aragonite sheets was found. The maximal pull-out force of the inclined-cross microstructure was analyzed based on its representative model and compared with that of a conventional 0 °- structure. The experimental result indicates that the maximal pull-out force of the inclined-cross microstructure is markedly larger than that of the 0°- structure.
文摘Suction caissons have been widely used as anchors and foundations for floating and fixed offshore platforms. The pull-out performance of conventional suction caissons (with upright walls) has been investigated by a number of researchers. However, no attention has been paid to tapered suction caissons. This paper deals with the performance of tapered suction caissons under vertical pull-out loads. A numerical approach is used for this purpose. The numerical model is first verified against test data available for common upright caissons. The verified model is then used to study the pullout performance of tapered suction caissons. It is noticed that the pull-out capacities exhibited by tapered suction caissons are in general considerably higher than those from their corresponding traditional upright caissons. To obtain an insight into this superior behaviour, effects from certain soil/caisson/drainage parameters on the pull-out capacity of tapered suction caissons are studied. Soil cohesion is noticed to have a linear improving effect on the capacity of both upright and ta- pered suction caissons. The soil internal friction angle is noticed to have an exponential increasing effect on the pull-out capacity. With a constant caisson diameter, an increase in the aspect ratio is seen to particularly influence the pull-out capacity. With a constant caisson length, an increase in the aspect ratio is discovered to result in non-linear decrease in the pull-out capacity. Under undrained conditions, tapered models generally show less sensitivity to above mentioned soil/caisson parameters as compared with those under drained conditions.
文摘针对传统电缆舞动检测器在面对电磁干扰和持续供电时灵敏度低、信噪比差、安装复杂和需额外供电等问题,提出一种新型双端Mach-Zehnder(M-Z)电缆扰动监测系统.该系统采用双端光纤M-Z光路结构,可实现长距离、大尺度、多维度的在线监测和结构安全预警,从而实时定位舞动位置.该系统的检波器力学单元采用硅胶弹性体和黄铜质量块推挽式结构,经ANSYS软件进行参数化建模和有限元分析后,得出其固有频率为106.77 Hz,与实验所测数据的相对误差仅为1.65%.实验结果表明,该检测器在0~140 Hz内的相对灵敏度为41.25~66.78 dB (rad/Pa),对舞动信号具有较高灵敏度的检测能力.