期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
Acoustic wireless communication based on parameter modulation and complex Lorenz chaotic systems with complex parameters and parametric attractors
1
作者 Fang-Fang Zhang Rui Gao Jian Liu 《Chinese Physics B》 SCIE EI CAS CSCD 2021年第8期248-259,共12页
As the competition for marine resources is increasingly fierce,the security of underwater acoustic communication has attracted a great deal of attention.The information and location of the communicating platform can b... As the competition for marine resources is increasingly fierce,the security of underwater acoustic communication has attracted a great deal of attention.The information and location of the communicating platform can be leaked during the traditional underwater acoustic communication technology.According to the unique advantages of chaos communication,we put forward a novel communication scheme using complex parameter modulation and the complex Lorenz system.Firstly,we design a feedback controller and parameter update laws in a complex-variable form with rigorous mathematical proofs(while many previous references on the real-variable form were only special cases in which the imaginary part was zero),which can be realized in practical engineering;then we design a new communication scheme employing parameter modulation.The main parameter spaces of the complex Lorenz system are discussed,then they are adopted in our communication scheme.We also find that there exist parametric attractors in the complex Lorenz system.We make numerical simulations in two channels for digital signals and the simulations verify our conclusions. 展开更多
关键词 parameter modulation identification chaotic system acoustic wireless communication
下载PDF
Parameters optimization for direct contact membrane distillation based on orthogonal experiment
2
作者 李娜 王寿江 +2 位作者 张龙明 刘安军 龚伟 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2012年第1期79-86,共8页
Parameter optimization integrating operation parameters and structure parameters for the purpose of high permeate flux,high productivity and low exergy consumption of direct contact membrane distillation (DCMD) proces... Parameter optimization integrating operation parameters and structure parameters for the purpose of high permeate flux,high productivity and low exergy consumption of direct contact membrane distillation (DCMD) process was conducted based on Taguchi experimental design. L16(45) orthogonal experiments were carried out with feed inlet temperature,permeate stream inlet temperature,flow rate,module packing density and length-diameter ratio as optimization parameters and with permeate flux,water productivity per unit volume of module and water production per unit exergy loss separately as optimization objectives. By using range analysis method,the dominance degree of the various influencing factors for the three objectives was analyzed and the optimum condition was obtained for the three objectives separately. Furthermore,the multi-objectives optimization was performed based on a weight grade method. The combined optimum conditions are feed inlet temperature 75℃,packing density 30% ,length-diameter ratio 10,permeate stream inlet temperature 30 ℃ and flow rate 25 L/h,which is in order of their dominance degree,and the validity of the optimization scheme was confirmed. 展开更多
关键词 direct contact membrane distillation operating conditions module configurations parameters orthogonal experiment single and multi-objective optimization
下载PDF
Influence of Structure Parameters on Performance of the Thermoelectric Module
3
作者 杜群贵 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2011年第3期464-468,共5页
A numerical model of thermoelectric module (TEM) is created by academic analysis,and the impacts of the resistance ratio and thermoelement size on the output power and thermoelectric efficiency of the TEM are analyz... A numerical model of thermoelectric module (TEM) is created by academic analysis,and the impacts of the resistance ratio and thermoelement size on the output power and thermoelectric efficiency of the TEM are analyzed by the MATLAB numerical calculation.The numerical model is validated by the ANSYS thermal,electrical,and structural coupling simulation.The effects of the variable physical property parameters and contact effect on the output power and thermoelectric efficiency are evaluated,and the concept of aspect ratio optimal domain is proposed,which provides a new design approach for the TEM. 展开更多
关键词 thermoelectric module (TEM) thermoelement contact effect variable physical property parameters output power thermoelectric efficiency
下载PDF
Demodulator for Chaotic Secure Communication Based on Proportional-integral Feedback Design
4
作者 邹润民 YangTao 《High Technology Letters》 EI CAS 2002年第3期67-71,共5页
A scheme of chaotic secure communication based on the parameter modulation and the inversion of a chaotic dynamical system is analyzed. According to this scheme, information signal is modulated by a bifurcation parame... A scheme of chaotic secure communication based on the parameter modulation and the inversion of a chaotic dynamical system is analyzed. According to this scheme, information signal is modulated by a bifurcation parameter of the transmitter, which is in chaotic state. In the receiver, a proportional integral feedback demodulator is used to demodulate the information signal, which only uses the available synchronizing error as well as stateness of receiver. The purpose of this demodulator is proposed to overcome the influence of differentiation operation, nonlinear part and singularities in chaotic system. Numerical simulation is proposed to show the effectiveness of this demodulator. 展开更多
关键词 chaotic secure communication PI demodulator chaotic synchronization parameter modulation
下载PDF
Effect of tilt angle on the performance and electrical parameters of a PV module:Comparative indoor and outdoor experimental investigation 被引量:2
5
作者 M.A.A.Mamun M.M.Islam +1 位作者 M.Hasanuzzaman Jeyraj Selvaraj 《Energy and Built Environment》 2022年第3期278-290,共13页
Photovoltaic(PV)system’s performance is significantly affected by its orientation and tilt angle.Experimental investigation(indoor and outdoor)has been carried out to trace the variation in PV performance and electri... Photovoltaic(PV)system’s performance is significantly affected by its orientation and tilt angle.Experimental investigation(indoor and outdoor)has been carried out to trace the variation in PV performance and electrical parameters at varying tilt angles in Malaysian conditions.There were two experimental modus:1)varying module tilt under constant irradiation level,2)varying irradiation intensity at the optimum tilt set up.For the former scheme,the irradiation level was maintained at 750 W/m^(2),and for the later arrangement,the module tilt angle was varied from 0 o to 80 o by means of a single-axis tracker.Results show that under constant irradiation of 750 W/m^(2),every 5 o increase in tilt angle causes a power drop of 2.09 W at indoor and 3.45 W at outdoor.In contrast,for the same condition,efficiency decreases by 0.54%for indoor case and by 0.76%at outdoor.On the other hand,for every 100 W/m^(2)increase in irradiation,solar cell temperature rises by 7.52℃at indoor and by 5.67℃at outdoor.As of module electrical parameters,open-circuit voltage,short-circuit current,maximum power point voltage and maximum power point current drops substantially with increasing tilt angle,whereas fill factor drops rather gradually.Outdoor experimental investigation confirms that the optimum tilt angle at Malaysian conditions is 15 o and orienting a PV module this angle will maximize the sun’s energy captured and thereby enhance its performance. 展开更多
关键词 PHOTOVOLTAIC Irradiation intensity Tilt angle PV performance Module electrical parameters
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部