期刊文献+
共找到216,349篇文章
< 1 2 250 >
每页显示 20 50 100
Method for rapid warning and activity concentration estimates in online waterγ-spectrometry systems
1
作者 Meng Wang Yi Gu +5 位作者 Mao-Lin Xiong Liang-Quan Ge Qing-Xian Zhang Guo-Qiang Zeng Heng Lu Sheng-Liang Guo 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第3期1-12,共12页
Onlineγ-spectrometry systems for inland waters,most of which extract samples in situ and in real time,are able to produce reliable activity concentration measurements for waterborne radionuclides only when they are d... Onlineγ-spectrometry systems for inland waters,most of which extract samples in situ and in real time,are able to produce reliable activity concentration measurements for waterborne radionuclides only when they are distributed relatively uniformly and enter into a steady-state diffusion regime in the measurement chamber.To protect residents’health and ensure the safety of the living environment,better timeliness is required for this measurement method.To address this issue,this study established a mathematical model of the online waterγ-spectrometry system so that rapid warning and activity estimates can be obtained for water under non-steady-state(NSS)conditions.In addition,the detection efficiency of the detector for radionuclides during the NSS diffusion process was determined by applying the computational fluid dynamics technique in conjunction with Monte Carlo simulations.On this basis,a method was developed that allowed the online waterγ-spectrometry system to provide rapid warning and activity concentration estimates for radionuclides in water.Subsequent analysis of the NSS-mode measurements of^(40)K radioactive solutions with different activity concentrations determined the optimum warning threshold and measurement time for producing accurate activity concentration estimates for radionuclides.The experimental results show that the proposed NSS measurement method is able to give warning and yield accurate activity concentration estimates for radionuclides 55.42 and 69.42 min after the entry of a 10 Bq/L^(40)K radioactive solution into the measurement chamber,respectively.These times are much shorter than the 90 min required by the conventional measurement method.Furthermore,the NSS measurement method allows the measurement system to give rapid(within approximately 15 min)warning when the activity concentrations of some radionuclides reach their respective limits stipulated in the Guidelines for Drinking-water Quality of the WHO,suggesting that this method considerably enhances the warning capacity of in situ online waterγ-spectrometry systems. 展开更多
关键词 Water radioactivity monitoring Dynamic detection efficiency Rapid warning Activity estimation
下载PDF
Energy evolution and structural health monitoring of coal under different failure modes:An experimental study
2
作者 Yarong Xue Xueqiu He +4 位作者 Dazhao Song Zhenlei Li Majid Khan Taoping Zhong Fei Yang 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2024年第5期917-928,共12页
Structural instability in underground engineering,especially in coal-rock structures,poses significant safety risks.Thus,the development of an accurate monitoring method for the health of coal-rock bodies is crucial.T... Structural instability in underground engineering,especially in coal-rock structures,poses significant safety risks.Thus,the development of an accurate monitoring method for the health of coal-rock bodies is crucial.The focus of this work is on understanding energy evolution patterns in coal-rock bodies under complex conditions by using shear,splitting,and uniaxial compression tests.We examine the changes in energy parameters during various loading stages and the effects of various failure modes,resulting in an innovative energy dissipation-based health evaluation technique for coal.Key results show that coal bodies go through transitions between strain hardening and softening mechanisms during loading,indicated by fluctuations in elastic energy and dissipation energy density.For tensile failure,the energy profile of coal shows a pattern of “high dissipation and low accumulation” before peak stress.On the other hand,shear failure is described by “high accumulation and low dissipation” in energy trends.Different failure modes correlate with an accelerated increase in the dissipation energy before destabilization,and a significant positive correlation is present between the energy dissipation rate and the stress state of the coal samples.A novel mathematical and statistical approach is developed,establishing a dissipation energy anomaly index,W,which categorizes the structural health of coal into different danger levels.This method provides a quantitative standard for early warning systems and is adaptable for monitoring structural health in complex underground engineering environments,contributing to the development of structural health monitoring technology. 展开更多
关键词 energy dissipation structural health monitoring early warning coal-rock mechanics failure mode
下载PDF
Design and Construction of Automatic Monitoring System for Open-pit Coal Mine Slopes
3
作者 Yu LUO 《Asian Agricultural Research》 2024年第6期19-21,24,共4页
[Objectives]To monitor the stability of open-pit coal mine slopes in real time and ensure the safety of coal mine production.[Methods]The automatic monitoring system of coal mine slope was explored in depth,and the co... [Objectives]To monitor the stability of open-pit coal mine slopes in real time and ensure the safety of coal mine production.[Methods]The automatic monitoring system of coal mine slope was explored in depth,and the core functions of the system were designed comprehensively.According to the design function of the automatic monitoring system,the slope automatic monitoring system was constructed.Besides,in accordance with the actual situation of the slope,the monitoring frequency of slopes was set scientifically,and the key indicators such as rainfall,deep displacement and surface displacement of the slopes were monitored in an all-round and multi-angle way.[Results]During the monitoring period,the overall condition of the slope remained good,and no landslides or other geological disasters occurred.At the same time,the overall rainfall in the slope area remained low.In terms of monitoring data,the horizontal displacement and settlement of the slopes increased first and then tended to be stable.Specifically,the maximum horizontal displacement during the monitoring period was 22.74 mm,while the maximum settlement was 18.65 mm.[Conclusions]The automatic slope monitoring system has obtained remarkable achievements in practical application.It not only improves the accuracy and efficiency of slope stability monitoring,but also provides valuable reference experience for similar projects. 展开更多
关键词 SLOPE monitoring Automatic monitoring technology Global NAVIGATION Satellite SYSTEM (GNSS) monitoring SYSTEM Early warning
下载PDF
Deformation warning index for reinforced concrete dam based on structural health monitoring data and numerical simulation 被引量:1
4
作者 Ming-qiang Zhan Bo Chen Zhong-ru Wu 《Water Science and Engineering》 EI CAS CSCD 2023年第4期408-418,共11页
The material mechanical parameters of the dam body and foundation will change when a dam is reinforced during the aging process.This causes significant changes in the structural state of the project and makes it diffi... The material mechanical parameters of the dam body and foundation will change when a dam is reinforced during the aging process.This causes significant changes in the structural state of the project and makes it difficult to ensure its structural safety.In this study,a new deformation warning index for reinforced concrete dams was developed according to the prototype monitoring data,statistical models,three-dimensional finite element model(FEM)numerical simulation,and the critical conditions of the dam structure.A statistical model was established to separate the water pressure component.Then,a three-dimensional FEM of the reinforced concrete dam was constructed to simulate the water pressure component.Furthermore,the deformation components that affected the mechanical parameters of the dam under the same amount of reservoir water level change were separated and quantified accurately.In addition,the method for inversion of comprehensive mechanical parameters after dam reinforcement was used.The influence mechanisms of the deformation behavior of concrete dams under the reservoir water level and temperature changes were investigated.A new deformation warning index was developed by combining the forward-simulated critical water pressure component and temperature component in the period of extreme temperature decrease with the aging component separated by the statistical model.The new deformation warning index considers the structural state of the dam before and after reinforcement and links the structural strength criterion and the deformation evolution mechanisms.It provides a theoretical foundation and decision support for long-term service and operation management of reinforced dams. 展开更多
关键词 Deformation warning index Structural health monitoring Finite element simulation REINFORCEMENT Multiple-arch dam Parameter inverse analysis
下载PDF
Comparing 11 early warning scores and three shock indices in early sepsis prediction in the emergency department
5
作者 Rex Pui Kin Lam Zonglin Dai +6 位作者 Eric Ho Yin Lau Carrie Yuen Ting Ip Ho Ching Chan Lingyun Zhao Tat ChiTsang Matthew Sik Hon Tsui Timothy Hudson Rainer 《World Journal of Emergency Medicine》 SCIE CAS CSCD 2024年第4期273-282,共10页
BACKGROUND:This study aimed to evaluate the discriminatory performance of 11 vital sign-based early warning scores(EWSs)and three shock indices in early sepsis prediction in the emergency department(ED).METHODS:We per... BACKGROUND:This study aimed to evaluate the discriminatory performance of 11 vital sign-based early warning scores(EWSs)and three shock indices in early sepsis prediction in the emergency department(ED).METHODS:We performed a retrospective study on consecutive adult patients with an infection over 3 months in a public ED in Hong Kong.The primary outcome was sepsis(Sepsis-3 definition)within 48 h of ED presentation.Using c-statistics and the DeLong test,we compared 11 EWSs,including the National Early Warning Score 2(NEWS2),Modified Early Warning Score,and Worthing Physiological Scoring System(WPS),etc.,and three shock indices(the shock index[SI],modified shock index[MSI],and diastolic shock index[DSI]),with Systemic Inflammatory Response Syndrome(SIRS)and quick Sequential Organ Failure Assessment(qSOFA)in predicting the primary outcome,intensive care unit admission,and mortality at different time points.RESULTS:We analyzed 601 patients,of whom 166(27.6%)developed sepsis.NEWS2 had the highest point estimate(area under the receiver operating characteristic curve[AUROC]0.75,95%CI 0.70-0.79)and was significantly better than SIRS,qSOFA,other EWSs and shock indices,except WPS,at predicting the primary outcome.However,the pooled sensitivity and specificity of NEWS2≥5 for the prediction of sepsis were 0.45(95%CI 0.37-0.52)and 0.88(95%CI 0.85-0.91),respectively.The discriminatory performance of all EWSs and shock indices declined when used to predict mortality at a more remote time point.CONCLUSION:NEWS2 compared favorably with other EWSs and shock indices in early sepsis prediction but its low sensitivity at the usual cut-off point requires further modification for sepsis screening. 展开更多
关键词 SEPSIS Emergency department Clinical prediction rule Early warning score Shock index
下载PDF
Early warning method for thermal runaway of lithium-ion batteries under thermal abuse condition based on online electrochemical impedance monitoring
6
作者 Yuxuan Li Lihua Jiang +5 位作者 Ningjie Zhang Zesen Wei Wenxin Mei Qiangling Duan Jinhua Sun Qingsong Wang 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2024年第5期74-86,共13页
Early warning of thermal runaway(TR)of lithium-ion batteries(LIBs)is a significant challenge in current application scenarios.Timely and effective TR early warning technology is urgently required considering the curre... Early warning of thermal runaway(TR)of lithium-ion batteries(LIBs)is a significant challenge in current application scenarios.Timely and effective TR early warning technology is urgently required considering the current fire safety situation of LIBs.In this work,we report an early warning method of TR with online electrochemical impedance spectroscopy(EIS)monitoring,which overcomes the shortcomings of warning methods based on traditional signals such as temperature,gas,and pressure with obvious delay and high cost.With in-situ data acquisition through accelerating rate calorimeter(ARC)-EIS test,the crucial features of TR were extracted using the RReliefF algorithm.TR mechanisms corresponding to the features at specific frequencies were analyzed.Finally,a three-level warning strategy for single battery,series module,and parallel module was formulated,which can successfully send out an early warning signal ahead of the self-heating temperature of battery under thermal abuse condition.The technology can provide a reliable basis for the timely intervention of battery thermal management and fire protection systems and is expected to be applied to electric vehicles and energy storage devices to realize early warning and improve battery safety. 展开更多
关键词 Online EIS measurement Lithium-ion batterysafety Multistage thermal runaway early warning SENSITIVITYANALYSIS
下载PDF
Accuracy of FreeStyle Libre flash glucose monitoring in patients with type 2 diabetes who migrated from highlands to plains
7
作者 Zeng-Mei Sun Yuan-Ze Du +11 位作者 Su-Yuan Wang Shu-Yao Sun Yan Ye Xue-Ping Sun Ming-Xia Li Hua He Wun-Chun Long Cheng-Hui Zhang Xuan-Yu Yao Wu-Yi Fan Ling Wang Yun-Hong Wu 《World Journal of Diabetes》 SCIE 2024年第6期1254-1262,共9页
BACKGROUND The FreeStyle Libre flash glucose monitoring(FGM)system entered the Chinese market in 2017 to complement the self-monitoring of blood glucose.Due to its increased usage in clinics,the number of studies inve... BACKGROUND The FreeStyle Libre flash glucose monitoring(FGM)system entered the Chinese market in 2017 to complement the self-monitoring of blood glucose.Due to its increased usage in clinics,the number of studies investigating its accuracy has increased.However,its accuracy has not been investigated in highland populations in China.AIM To evaluate measurements recorded using the FreeStyle Libre FGM system compared with capillary blood glucose measured using the enzyme electrode method in patients with type 2 diabetes(T2D)who had migrated within 3 mo from highlands to plains.METHODS Overall,68 patients with T2D,selected from those who had recently migrated from highlands to plains(within 3 mo),were hospitalized at the Department of Endocrinology from August to October 2017 and underwent continuous glucose monitoring(CGM)with the FreeStyle Libre FGM system for 14 d.Throughout the study period,fingertip capillary blood glucose was measured daily using the enzyme electrode method(Super GL,China),and blood glucose levels were read from the scanning probe during fasting and 2 h after all three meals.Moreover,the time interval between reading the data from the scanning probe and collecting fingertip capillary blood was controlled to<5 min.The accuracy of the FGM system was evaluated according to the CGM guidelines.Subsequently,the factors influencing the mean absolute relative difference(MARD)of this system were analyzed by a multiple linear regression method.RESULTS Pearson’s correlation analysis showed that the fingertip and scanned glucose levels were positively correlated(R=0.86,P=0.00).The aggregated MARD of scanned glucose was 14.28±13.40%.Parker's error analysis showed that 99.30%of the data pairs were located in areas A and B.According to the probe wear time of the FreeStyle Libre FGM system,MARD_(1 d) and MARD_(2-14 d) were 16.55%and 14.35%,respectively(t=1.23,P=0.22).Multiple stepwise regression analysis showed that MARD did not correlate with blood glucose when the largest amplitude of glycemic excursion(LAGE)was<5.80 mmol/L but negatively correlated with blood glucose when the LAGE was≥5.80 mmol/L.CONCLUSION The FreeStyle Libre FGM system has good accuracy in patients with T2D who had recently migrated from highlands to plains.This system might be ideal for avoiding the effects of high hematocrit on blood glucose monitoring in populations that recently migrated to plains.MARD is mainly influenced by glucose levels and fluctuations,and the accuracy of the system is higher when the blood glucose fluctuation is small.In case of higher blood glucose level fluctuations,deviation in the scanned glucose levels is the highest at extremely low blood glucose levels. 展开更多
关键词 Type 2 diabetes Flash glucose monitoring ACCURACY Continuous glucose monitor High altitude
下载PDF
Identification of Early Warning Signals of Infectious Diseases in Hospitals by Integrating Clinical Treatment and Disease Prevention
8
作者 Lei ZHANG Min-ye LI +2 位作者 Chen ZHI Min ZHU Hui MA 《Current Medical Science》 SCIE CAS 2024年第2期273-280,共8页
The global incidence of infectious diseases has increased in recent years,posing a significant threat to human health.Hospitals typically serve as frontline institutions for detecting infectious diseases.However,accur... The global incidence of infectious diseases has increased in recent years,posing a significant threat to human health.Hospitals typically serve as frontline institutions for detecting infectious diseases.However,accurately identifying warning signals of infectious diseases in a timely manner,especially emerging infectious diseases,can be challenging.Consequently,there is a pressing need to integrate treatment and disease prevention data to conduct comprehensive analyses aimed at preventing and controlling infectious diseases within hospitals.This paper examines the role of medical data in the early identification of infectious diseases,explores early warning technologies for infectious disease recognition,and assesses monitoring and early warning mechanisms for infectious diseases.We propose that hospitals adopt novel multidimensional early warning technologies to mine and analyze medical data from various systems,in compliance with national strategies to integrate clinical treatment and disease prevention.Furthermore,hospitals should establish institution-specific,clinical-based early warning models for infectious diseases to actively monitor early signals and enhance preparedness for infectious disease prevention and control. 展开更多
关键词 infectious disease disease prevention and control medical data warning signals
下载PDF
Application and management of continuous glucose monitoring in diabetic kidney disease
9
作者 Xin-Miao Zhang Quan-Quan Shen 《World Journal of Diabetes》 SCIE 2024年第4期591-597,共7页
Diabetic kidney disease(DKD)is a common complication of diabetes mellitus that contributes to the risk of end-stage kidney disease(ESKD).Wide glycemic var-iations,such as hypoglycemia and hyperglycemia,are broadly fou... Diabetic kidney disease(DKD)is a common complication of diabetes mellitus that contributes to the risk of end-stage kidney disease(ESKD).Wide glycemic var-iations,such as hypoglycemia and hyperglycemia,are broadly found in diabetic patients with DKD and especially ESKD,as a result of impaired renal metabolism.It is essential to monitor glycemia for effective management of DKD.Hemoglobin A1c(HbA1c)has long been considered as the gold standard for monitoring glycemia for>3 months.However,assessment of HbA1c has some bias as it is susceptible to factors such as anemia and liver or kidney dysfunction.Continuous glucose monitoring(CGM)has provided new insights on glycemic assessment and management.CGM directly measures glucose level in interstitial fluid,reports real-time or retrospective glucose concentration,and provides multiple glycemic metrics.It avoids the pitfalls of HbA1c in some contexts,and may serve as a precise alternative to estimation of mean glucose and glycemic variability.Emerging studies have demonstrated the merits of CGM for precise monitoring,which allows fine-tuning of glycemic management in diabetic patients.Therefore,CGM technology has the potential for better glycemic monitoring in DKD patients.More research is needed to explore its application and management in different stages of DKD,including hemodialysis,peritoneal dialysis and kidney transplantation. 展开更多
关键词 Diabetic kidney disease Continuous glucose monitoring Glycemic monitoring HEMODIALYSIS Peritoneal dialysis Kidney transplantation
下载PDF
Push forward LC-MS-based therapeutic drug monitoring and pharmacometabolomics for anti-tuberculosis precision dosing and comprehensive clinical management
10
作者 Nguyen Quang Thu Nguyen Tran Nam Tien +3 位作者 Nguyen Thi Hai Yen Thuc-Huy Duong Nguyen Phuoc Long Huy Truong Nguyen 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2024年第1期16-38,共23页
The spread of tuberculosis(TB),especially multidrug-resistant TB and extensively drug-resistant TB,has strongly motivated the research and development of new anti-TB drugs.New strategies to facilitate drug combination... The spread of tuberculosis(TB),especially multidrug-resistant TB and extensively drug-resistant TB,has strongly motivated the research and development of new anti-TB drugs.New strategies to facilitate drug combinations,including pharmacokinetics-guided dose optimization and toxicology studies of first-and second-line anti-TB drugs have also been introduced and recommended.Liquid chromatography-mass spectrometry(LC-MS)has arguably become the gold standard in the analysis of both endo-and exo-genous compounds.This technique has been applied successfully not only for therapeutic drug monitoring(TDM)but also for pharmacometabolomics analysis.TDM improves the effectiveness of treatment,reduces adverse drug reactions,and the likelihood of drug resistance development in TB patients by determining dosage regimens that produce concentrations within the therapeutic target window.Based on TDM,the dose would be optimized individually to achieve favorable outcomes.Pharmacometabolomics is essential in generating and validating hypotheses regarding the metabolism of anti-TB drugs,aiding in the discovery of potential biomarkers for TB diagnostics,treatment monitoring,and outcome evaluation.This article highlighted the current progresses in TDM of anti-TB drugs based on LC-MS bioassay in the last two decades.Besides,we discussed the advantages and disadvantages of this technique in practical use.The pressing need for non-invasive sampling approaches and stability studies of anti-TB drugs was highlighted.Lastly,we provided perspectives on the prospects of combining LC-MS-based TDM and pharmacometabolomics with other advanced strategies(pharmacometrics,drug and vaccine developments,machine learning/artificial intelligence,among others)to encapsulate in an all-inclusive approach to improve treatment outcomes of TB patients. 展开更多
关键词 TUBERCULOSIS Therapeutic drug monitoring LC-MS MIPD Pharmacometabolomics Precision medicine
下载PDF
ARHCS (Automatic Rainfall Half-Life Cluster System): A Landslides Early Warning System (LEWS) Using Cluster Analysis and Automatic Threshold Definition
11
作者 Cassiano Antonio Bortolozo Luana Albertani Pampuch +8 位作者 Marcio Roberto Magalhães De Andrade Daniel Metodiev Adenilson Roberto Carvalho Tatiana Sussel Gonçalves Mendes Tristan Pryer Harideva Marturano Egas Rodolfo Moreda Mendes Isadora Araújo Sousa Jenny Power 《International Journal of Geosciences》 CAS 2024年第1期54-69,共16页
A significant portion of Landslide Early Warning Systems (LEWS) relies on the definition of operational thresholds and the monitoring of cumulative rainfall for alert issuance. These thresholds can be obtained in vari... A significant portion of Landslide Early Warning Systems (LEWS) relies on the definition of operational thresholds and the monitoring of cumulative rainfall for alert issuance. These thresholds can be obtained in various ways, but most often they are based on previous landslide data. This approach introduces several limitations. For instance, there is a requirement for the location to have been previously monitored in some way to have this type of information recorded. Another significant limitation is the need for information regarding the location and timing of incidents. Despite the current ease of obtaining location information (GPS, drone images, etc.), the timing of the event remains challenging to ascertain for a considerable portion of landslide data. Concerning rainfall monitoring, there are multiple ways to consider it, for instance, examining accumulations over various intervals (1 h, 6 h, 24 h, 72 h), as well as in the calculation of effective rainfall, which represents the precipitation that actually infiltrates the soil. However, in the vast majority of cases, both the thresholds and the rain monitoring approach are defined manually and subjectively, relying on the operators’ experience. This makes the process labor-intensive and time-consuming, hindering the establishment of a truly standardized and rapidly scalable methodology on a large scale. In this work, we propose a Landslides Early Warning System (LEWS) based on the concept of rainfall half-life and the determination of thresholds using Cluster Analysis and data inversion. The system is designed to be applied in extensive monitoring networks, such as the one utilized by Cemaden, Brazil’s National Center for Monitoring and Early Warning of Natural Disasters. 展开更多
关键词 Landslides Early warning System (LEWS) Cluster Analysis LandSLIDES Brazil
下载PDF
Nanomaterial-assisted wearable glucose biosensors for noninvasive real-time monitoring:Pioneering point-of-care and beyond
12
作者 Moein Safarkhani Abdullah Aldhaher +5 位作者 Golnaz Heidari Ehsan Nazarzadeh Zare Majid Ebrahimi Warkiani Omid Akhavan YunSuk Huh Navid Rabiee 《Nano Materials Science》 EI CAS CSCD 2024年第3期263-283,共21页
This review explores glucose monitoring and management strategies,emphasizing the need for reliable and userfriendly wearable sensors that are the next generation of sensors for continuous glucose detection.In additio... This review explores glucose monitoring and management strategies,emphasizing the need for reliable and userfriendly wearable sensors that are the next generation of sensors for continuous glucose detection.In addition,examines key strategies for designing glucose sensors that are multi-functional,reliable,and cost-effective in a variety of contexts.The unique features of effective diabetes management technology are highlighted,with a focus on using nano/biosensor devices that can quickly and accurately detect glucose levels in the blood,improving patient treatment and control of potential diabetes-related infections.The potential of next-generation wearable and touch-sensitive nano biomedical sensor engineering designs for providing full control in assessing implantable,continuous glucose monitoring is also explored.The challenges of standardizing drug or insulin delivery doses,low-cost,real-time detection of increased blood sugar levels in diabetics,and early digital health awareness controls for the adverse effects of injectable medication are identified as unmet needs.Also,the market for biosensors is expected to expand significantly due to the rising need for portable diagnostic equipment and an ever-increasing diabetic population.The paper concludes by emphasizing the need for further research and development of glucose biosensors to meet the stringent requirements for sensitivity and specificity imposed by clinical diagnostics while being cost-effective,stable,and durable. 展开更多
关键词 Glucose sensor BIOSENSOR Wearable devices NONINVASIVE Real-time monitoring
下载PDF
Clinical/Behavioral Monitoring of Rodents and Rabbits Undergoing Scientific Experiments
13
作者 Luiz Cesar Cavalcanti Pereira Jhônata Willy Rocha Coelho +5 位作者 Hyago da Silva Medeiros Elidio Rita de Cássia dos Passos Ferraz Da Silva João Gabriel Regis Sobral Bárbara Alves de Brito Soledade Leandro Thomaz Vilela Isabele Barbieri Dos Santos 《Open Journal of Veterinary Medicine》 CAS 2024年第5期91-109,共19页
Background: We currently have international and national guidelines regarding the assessment and monitoring of clinical signs and humane endpoints in animals used in teaching and research, which make the performance o... Background: We currently have international and national guidelines regarding the assessment and monitoring of clinical signs and humane endpoints in animals used in teaching and research, which make the performance of these activities mandatory for any experiment and professional working in this area. Assigning the severity of a research experiment is the result of an analysis of records of observations of the animal’s behavior, and clinical signs. The aim of this study was to describe the importance of carrying out a severity assessment associated with clinical and behavioral monitoring of rodents and rabbits during experimentation to maintain the welfare of these animals undergoing scientific research. Methods: The literature search was carried out using the following terms: “Monitoring”;“Humane endpoints”;“Animal welfare”, “Rodents”;“Rabbits”, and as connectors “and”;“or”, in the following databases: PubMed;LILACS/BIREME and SciELO. Results: A total of 987 articles were identified in the databases, and 20 of these studies were included in this review. Conclusions: Humane endpoint protocols and procedure severity tables are of the utmost importance, both from an ethical point and to refine the results of research conducted on laboratory animals. They should be drawn up jointly by the teams responsible for the project and the maintenance of the animals during the research period, and the data obtained should be published so that the scientific community can have access to it, helping to disseminate these practices, as well as helping to draw up new procedures. Monitoring and evaluating the welfare and clinical condition of animals undergoing scientific research procedures is the responsibility of the professors, researchers, veterinarians, and animal facility coordinators. The Ethics Committee on the Use of Animals must monitor all the activities conducted with the animals, by inspecting the experimental procedures and the physical environment of the laboratory animal facility where the animals are housed. 展开更多
关键词 monitoring Humane Endpoints Animal Welfare Experimental Design Laboratory Animals’ Investigations
下载PDF
An improved typhoon monitoring model based on precipitable water vapor and pressure
14
作者 Junyu Li Haojie Li +7 位作者 Lilong Liu Jiaqing Chen Yibin Yao Mingyun Hu Liangke Huang Fade Chen Tengxu Zhang Lv Zhou 《Geodesy and Geodynamics》 EI CSCD 2024年第3期276-290,共15页
The potential of monitoring the movement of typhoons using the precipitable water vapor(PWV) has been confirmed. However, monitoring the movement of typhoon is focused on PWV, making it difficult to describe the movem... The potential of monitoring the movement of typhoons using the precipitable water vapor(PWV) has been confirmed. However, monitoring the movement of typhoon is focused on PWV, making it difficult to describe the movement of a typhoon in detail minutely and resulting in insufficient accuracy. Hence,based on PWV and meteorological data, we propose an improved typhoon monitoring mode. First, the European Centre for Medium-Range Weather Forecasts Reanalysis 5-derived PWV(ERA5-PWV) and the Global Navigation Satellite System-derived PWV(GNSS-PWV) were compared with the reference radiosonde PWV(RS-PWV). Then, using the PWV and atmospheric parameters derived from ERA5, we discussed the anomalous variations of PWV, pressure(P), precipitation, and wind speed during different typhoons. Finally, we compiled a list of critical factors related to typhoon movement, PWV and P. We developed an improved multi-factor typhoon monitoring mode(IMTM) with different models(i.e.,IMTM-I and IMTM-II) in different cases with a higher density of GNSS observation or only Numerical Weather Prediction(NWP) data. The IMTM was evaluated through the reference movement speeds of HATO and Mangkhut from the China Meteorological Observatory Typhoon Network(CMOTN). The results show that the root mean square(RMS) of the IMTM-I is 1.26 km/h based on ERA5-P and ERA5-PWV,and the absolute bias values are mostly within 2 km/h. Compared with the models considering the single factor ERA5-P/ERA5-PWV, the RMS of the IMTM-I is improved by 26.3% and 38.5%, respectively. The IMTM-II model manifests a residual of only 0.35 km/h. Compared with the single-factor model based on GNSS-PWV/P, the residual of the IMTM-II model is reduced by 90.8% and 84.1%, respectively. These results propose that the typhoon movement monitoring approach combining PWV and P has evident advantages over the single-factor model and is expected to supplement traditional typhoon monitoring. 展开更多
关键词 TYPHOON GNSS/ERA5 PWV PRESSURE monitoring Improved model
下载PDF
Pretreatment and analysis techniques development of TKIs in biological samples for pharmacokinetic studies and therapeutic drug monitoring
15
作者 Lan Chen Yuan Zhang +5 位作者 Yi-Xin Zhang Wei-Lai Wang De-Mei Sun Peng-Yun Li Xue-Song Feng Yue Tan 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2024年第4期439-459,共21页
Tyrosine kinase inhibitors(TKIs)have emerged as the first-line small molecule drugs in many cancer therapies,exerting their effects by impeding aberrant cell growth and proliferation through the modulation of tyrosine... Tyrosine kinase inhibitors(TKIs)have emerged as the first-line small molecule drugs in many cancer therapies,exerting their effects by impeding aberrant cell growth and proliferation through the modulation of tyrosine kinase-mediated signaling pathways.However,there exists a substantial inter-individual variability in the concentrations of certain TKIs and their metabolites,which may render patients with compromised immune function susceptible to diverse infections despite receiving theoretically efficacious anticancer treatments,alongside other potential side effects or adverse reactions.Therefore,an urgent need exists for an up-to-date review concerning the biological matrices relevant to bioanalysis and the sampling methods,clinical pharmacokinetics,and therapeutic drug monitoring of different TKIs.This paper provides a comprehensive overview of the advancements in pretreatment methods,such as protein precipitation(PPT),liquid-liquid extraction(LLE),solid-phase extraction(SPE),micro-SPE(μ-SPE),magnetic SPE(MSPE),and vortex-assisted dispersive SPE(VA-DSPE)achieved since 2017.It also highlights the latest analysis techniques such as newly developed high performance liquid chromatography(HPLC)and high-resolution mass spectrometry(HRMS)methods,capillary electrophoresis(CE),gas chromatography(GC),supercritical fluid chromatography(SFC)procedures,surface plasmon resonance(SPR)assays as well as novel nanoprobes-based biosensing techniques.In addition,a comparison is made between the advantages and disadvantages of different approaches while presenting critical challenges and prospects in pharmacokinetic studies and therapeutic drug monitoring. 展开更多
关键词 TKIs Microextraction technique HRMS methods Pharmacokinetic studies Therapeutic drug monitoring
下载PDF
Long-term hydrochemical monitoring and geothermometry:understanding groundwater salinization and thermal fluid contamination in Mila’s basin,Northeastern Algeria
16
作者 Yasmina Bouroubi-Ouadfel Adnane Souffi Moulla Abdelkader Khiari 《Acta Geochimica》 EI CAS CSCD 2024年第3期459-477,共19页
The regular hydrochemical monitoring of groundwater in the Mila basin over an extended period has provided valuable insights into the origin of dissolved salts and the hydrogeochemical processes controlling water sali... The regular hydrochemical monitoring of groundwater in the Mila basin over an extended period has provided valuable insights into the origin of dissolved salts and the hydrogeochemical processes controlling water salinization.The data reveals that the shallow Karst aquifer shows an increase in TDS of 162 mg L^(-1) while the ther-mal carbonate aquifer that is also used for drinking water supply exhibits an increase of 178 mg L^(-1).Additionally,significant temperature variations are recorded at the sur-face in the shallow aquifers and the waters are carbo-gaseous.Analysis of dissolved major and minor elements has identified several processes influencing the chemical composition namely:dissolution of evaporitic minerals,reduction of sulphates,congruent and incongruent car-bonates’dissolution,dedolomitization and silicates’weathering.The hydrogeochemical and geothermometric results show a mixing of saline thermal water with recharge water of meteoric origin.Two main geothermalfields have been identified,a partially evolved water reservoir and a water reservoir whosefluid interacts with sulphuric acid(H_(2)S)of magmatic origin.These hot waters that are char-acterized by a strong hydrothermal alteration do ascend through faults and fractures and contribute to the contamination of shallower aquifers.Understanding the geothermometry and the hydrogeochemistry of waters is crucial for managing and protecting the quality of groundwater resources in the Mila basin,in order to ensure sustainable water supply for the region.A conceptual model for groundwater circulation and mineralization acquisition has been established to further enhance under-standing in this regard. 展开更多
关键词 Hydrochemical monitoring HYDROGEOCHEMISTRY SALINIZATION Geothermal reservoir CONTAMINATION Mila’s basin
下载PDF
Microarrow sensor array with enhanced skin adhesion for transdermal continuous monitoring of glucose and reactive oxygen species
17
作者 Xinshuo Huang Baoming Liang +9 位作者 Shantao Zheng Feifei Wu Mengyi He Shuang Huang Jingbo Yang Qiangqiang Ouyang Fanmao Liu Jing Liu Hui-jiuan Chen Xi Xie 《Bio-Design and Manufacturing》 SCIE EI CAS CSCD 2024年第1期14-30,共17页
Conventional blood sampling for glucose detection is prone to cause pain and fails to continuously record glucose fluctuations in vivo.Continuous glucose monitoring based on implantable electrodes could induce pain an... Conventional blood sampling for glucose detection is prone to cause pain and fails to continuously record glucose fluctuations in vivo.Continuous glucose monitoring based on implantable electrodes could induce pain and potential tissue inflammation,and the presence of reactive oxygen species(ROS)due to inflammationmay affect glucose detection.Microneedle technology is less invasive,yet microneedle adhesion with skin tissue is limited.In this work,we developed a microarrow sensor array(MASA),which provided enhanced skin surface adhesion and enabled simultaneous detection of glucose and H_(2)O_(2)(representative of ROS)in interstitial fluid in vivo.The microarrows fabricated via laser micromachining were modified with functional coating and integrated into a patch of a three-dimensional(3D)microneedle array.Due to the arrow tip mechanically interlocking with the tissue,the microarrow array could better adhere to the skin surface after penetration into skin.The MASA was demonstrated to provide continuous in vivo monitoring of glucose and H_(2)O_(2) concentrations,with the detection of H_(2)O_(2) providing a valuable reference for assessing the inflammation state.Finally,the MASA was integrated into a monitoring system using custom circuitry.This work provides a promising tool for the stable and reliable monitoring of blood glucose in diabetic patients. 展开更多
关键词 Microarrow sensor array Glucose sensing Reactive oxygen species sensing Integrated system Continuous monitoring
下载PDF
Comparative Analysis of ARIMA and LSTM Model-Based Anomaly Detection for Unannotated Structural Health Monitoring Data in an Immersed Tunnel
18
作者 Qing Ai Hao Tian +4 位作者 Hui Wang Qing Lang Xingchun Huang Xinghong Jiang Qiang Jing 《Computer Modeling in Engineering & Sciences》 SCIE EI 2024年第5期1797-1827,共31页
Structural Health Monitoring(SHM)systems have become a crucial tool for the operational management of long tunnels.For immersed tunnels exposed to both traffic loads and the effects of the marine environment,efficient... Structural Health Monitoring(SHM)systems have become a crucial tool for the operational management of long tunnels.For immersed tunnels exposed to both traffic loads and the effects of the marine environment,efficiently identifying abnormal conditions from the extensive unannotated SHM data presents a significant challenge.This study proposed amodel-based approach for anomaly detection and conducted validation and comparative analysis of two distinct temporal predictive models using SHM data from a real immersed tunnel.Firstly,a dynamic predictive model-based anomaly detectionmethod is proposed,which utilizes a rolling time window for modeling to achieve dynamic prediction.Leveraging the assumption of temporal data similarity,an interval prediction value deviation was employed to determine the abnormality of the data.Subsequently,dynamic predictive models were constructed based on the Autoregressive Integrated Moving Average(ARIMA)and Long Short-Term Memory(LSTM)models.The hyperparameters of these models were optimized and selected using monitoring data from the immersed tunnel,yielding viable static and dynamic predictive models.Finally,the models were applied within the same segment of SHM data,to validate the effectiveness of the anomaly detection approach based on dynamic predictive modeling.A detailed comparative analysis discusses the discrepancies in temporal anomaly detection between the ARIMA-and LSTM-based models.The results demonstrated that the dynamic predictive modelbased anomaly detection approach was effective for dealing with unannotated SHM data.In a comparison between ARIMA and LSTM,it was found that ARIMA demonstrated higher modeling efficiency,rendering it suitable for short-term predictions.In contrast,the LSTM model exhibited greater capacity to capture long-term performance trends and enhanced early warning capabilities,thereby resulting in superior overall performance. 展开更多
关键词 Anomaly detection dynamic predictive model structural health monitoring immersed tunnel LSTM ARIMA
下载PDF
Appropriateness of Amikacin Dose Prescription, Monitoring and Safety during Hospitalization as an Impact of Clinical Pharmacologist Intervention, in the Israeli Regional Hospital
19
作者 Renata Shihmanter Olga Lazar Lidia Arcavi 《Journal of Biosciences and Medicines》 2024年第3期337-354,共18页
Background: Use of inappropriate amikacin dose is one of the most important factors in inducing toxicity, prolonged hospitalization as well as in increasing patient’s mortality. Objective: The aims of this study are ... Background: Use of inappropriate amikacin dose is one of the most important factors in inducing toxicity, prolonged hospitalization as well as in increasing patient’s mortality. Objective: The aims of this study are the analysis of amikacin dose, serum level and the examination of the effectiveness of the clinical pharmacologist (CP) therapeutic drug monitoring (TDM) intervention to guarantee the safety of amikacin use. Methods: This is a one-year retrospective observational chart review study, which evaluates amikacin dose, serum drug level, development of adverse effects in patients on amikacin with or without CP TDM consultation. Results: Amikacin was prescribed for 393 complex patients, with median age 83. Amikacin group (AG) included 140 (32%) courses with CP consultation (AG1) and 292 (68%) courses without CP consultation (AG2). The distribution of most study characteristics in both groups was similar including amikacin dose (9-10 mg/kg/day), renal failure (14%) and mortality (12%). Acceptance for CP consultation was in 46% of amikacin courses and dose changes were done in 63% after CP intervention. Prolonged antibiotic course (4.6 ± 1.5 vs 3.8 ± 1.6 days, p < 0.0001) and the patient’s hemodynamic instability (15% vs 7%, p = 0.01) were more frequent in the AG1 compared to the AG2. There was a strong association between CP consultation and prolonged hospitalization (p = 0.005), while no association between it and amikacin adverse effects, renal failure or mortality. Conclusions: There was no trend to reducing amikacin toxicity, days of hospitaliza tion or mortality in patients with CP consultation. CP TDM intervention was more in the management of complicated clinical situations. However, it is necessary to optimize it. 展开更多
关键词 AMIKACIN Therapeutic Drug monitoring APPROPRIATE Clinical Pharmacologist SAFETY Adverse Effects
下载PDF
VR-based digital twin for remote monitoring of mining equipment:Architecture and a case study
20
作者 Jovana PLAVŠIĆ Ilija MIŠKOVIĆNorman BKeevil 《虚拟现实与智能硬件(中英文)》 EI 2024年第2期100-112,共13页
Background Traditional methods for monitoring mining equipment rely primarily on visual inspections,which are time-consuming,inefficient,and hazardous.This article introduces a novel approach to monitoring mission-cri... Background Traditional methods for monitoring mining equipment rely primarily on visual inspections,which are time-consuming,inefficient,and hazardous.This article introduces a novel approach to monitoring mission-critical systems and services in the mining industry by integrating virtual reality(VR)and digital twin(DT)technologies.VR-based DTs enable remote equipment monitoring,advanced analysis of machine health,enhanced visualization,and improved decision making.Methods This article presents an architecture for VR-based DT development,including the developmental stages,activities,and stakeholders involved.A case study on the condition monitoring of a conveyor belt using real-time synthetic vibration sensor data was conducted using the proposed methodology.The study demonstrated the application of the methodology in remote monitoring and identified the need for further development for implementation in active mining operations.The article also discusses interdisciplinarity,choice of tools,computational resources,time and cost,human involvement,user acceptance,frequency of inspection,multiuser environment,potential risks,and applications beyond the mining industry.Results The findings of this study provide a foundation for future research in the domain of VR-based DTs for remote equipment monitoring and a novel application area for VR in mining. 展开更多
关键词 Virtual reality Digital twin Condition monitoring Mining equipment
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部