A new convenient sulfide electrochemical sensor for marine environmental in situ monitoring and real time survey was developed. The new sensor based on a solid Ag 2S membrane electrode has outstanding chemical sensiti...A new convenient sulfide electrochemical sensor for marine environmental in situ monitoring and real time survey was developed. The new sensor based on a solid Ag 2S membrane electrode has outstanding chemical sensitivity and stability. It responds to the activity of sulfide ions according to a Nernstian slope of -31mV/decade. The sensor can be used to determine the total concentration of sulfides ( C T) by calibrating the pH value of the solution to a standard pH. The practical measurement range for total sulfide concentration is 0.1-10 mg/L in seawater. The sensor has a very low potential drift (<4mV) during two months in 0.1 mg/L sulfide seawater. This paper describes the preparation of the sensitive membrane and some main properties of the sensor.展开更多
Through the analysis of the principle, error sources and precision of trigonometric leveling, this paper points out the key problems about first order leveling replaced by trigonometric leveling; and for the first tim...Through the analysis of the principle, error sources and precision of trigonometric leveling, this paper points out the key problems about first order leveling replaced by trigonometric leveling; and for the first time puts forward that, in some given conditions, it is not only feasible but also valuable to replace first order leveling by precise trigonometric leveling, and proves it by experimentation as well. The content and conclusion of this paper have consulting significance and practicable value for our setting down relational criterion and production practice.展开更多
文摘A new convenient sulfide electrochemical sensor for marine environmental in situ monitoring and real time survey was developed. The new sensor based on a solid Ag 2S membrane electrode has outstanding chemical sensitivity and stability. It responds to the activity of sulfide ions according to a Nernstian slope of -31mV/decade. The sensor can be used to determine the total concentration of sulfides ( C T) by calibrating the pH value of the solution to a standard pH. The practical measurement range for total sulfide concentration is 0.1-10 mg/L in seawater. The sensor has a very low potential drift (<4mV) during two months in 0.1 mg/L sulfide seawater. This paper describes the preparation of the sensitive membrane and some main properties of the sensor.
文摘Through the analysis of the principle, error sources and precision of trigonometric leveling, this paper points out the key problems about first order leveling replaced by trigonometric leveling; and for the first time puts forward that, in some given conditions, it is not only feasible but also valuable to replace first order leveling by precise trigonometric leveling, and proves it by experimentation as well. The content and conclusion of this paper have consulting significance and practicable value for our setting down relational criterion and production practice.