As the demand for more efficient and adaptable power distribution systems intensifies, especially in rural areas, innovative solutions like the Capacitor-Coupled Substation with a Controllable Network Transformer (CCS...As the demand for more efficient and adaptable power distribution systems intensifies, especially in rural areas, innovative solutions like the Capacitor-Coupled Substation with a Controllable Network Transformer (CCS-CNT) are becoming increasingly critical. Traditional power distribution networks, often limited by unidirectional flow capabilities and inflexibility, struggle to meet the complex demands of modern energy systems. The CCS-CNT system offers a transformative approach by enabling bidirectional power flow between high-voltage transmission lines and local distribution networks, a feature that is essential for integrating renewable energy sources and ensuring reliable electrification in underserved regions. This paper presents a detailed mathematical representation of power flow within the CCS-CNT system, emphasizing the control of both active and reactive power through the adjustment of voltage levels and phase angles. A control algorithm is developed to dynamically manage power flow, ensuring optimal performance by minimizing losses and maintaining voltage stability across the network. The proposed CCS-CNT system demonstrates significant potential in enhancing the efficiency and reliability of power distribution, making it particularly suited for rural electrification and other applications where traditional methods fall short. The findings underscore the system's capability to adapt to varying operational conditions, offering a robust solution for modern power distribution challenges.展开更多
A general model of flexible isolation systems which involves both the passive and active control factors is established by inserting actuators into an passive isolation system. And the power flow transmission function...A general model of flexible isolation systems which involves both the passive and active control factors is established by inserting actuators into an passive isolation system. And the power flow transmission function in such a system as with multi disturbance, multi mounts, passive isolators and actuators is deduced. By means of the numerical simulation method, the influence of actuators on power flow transmission characteristic is studied. And as a conclusion, the passive active synthetic control strategy of power flow is summarized.展开更多
L-shaped plates have become an important focuses in structural vibration research. To determine their vibration characteristics, this paper applied a mobility power flow method. Firstly, the L-shaped plate was divided...L-shaped plates have become an important focuses in structural vibration research. To determine their vibration characteristics, this paper applied a mobility power flow method. Firstly, the L-shaped plate was divided into two substructures to simplify analysis. The coupled bending moment was then deduced by applying a continuous vibration property on the common edge. Next, the response on any point of the plate and the input and transmitted power flow formulas were calculated. Numerical simulations showed the distribution of the coupled bending moment and the response of the whole structure. The validity of this method was verified by the SEA approach.展开更多
A novel combined model of the vibration control for the coupled flexiblesystem and its general mathematic description are developed. In presented model, active and passivecontrols as well as force and moment controls ...A novel combined model of the vibration control for the coupled flexiblesystem and its general mathematic description are developed. In presented model, active and passivecontrols as well as force and moment controls are combined into a single unit to achieve theefficient vibration control of the flexible structures by multi-approaches. Considering thecomplexity of the energy transmission in the vibrating system, the transmission channels of thepower flow transmitted into the foundation are discussed, and the general forces and thecorresponding velocities are combined into a single function, respectively. Under the controlstrategy of the minimum power flow, the transmission characteristics of the power flow areinvestigated. From the presented numerical examples, it is obvious that the analytical model iseffective, and both force and moment controls are able to depress vibration energy substantially.展开更多
Heat exchanger systems(HXSs)or heat recovery steam generators(HRSGs)are commonly used in 100 kW to 50 MW combined cooling,heating,and power(CCHP)systems.Power flow coupling(PFC)is found in HXSs and is complex for rese...Heat exchanger systems(HXSs)or heat recovery steam generators(HRSGs)are commonly used in 100 kW to 50 MW combined cooling,heating,and power(CCHP)systems.Power flow coupling(PFC)is found in HXSs and is complex for researchers to quantify.This could possibly mislead the dispatch schedule and result in the inaccurate dispatch.PFC is caused by the inlet and outlet temperatures of each component,gas flow pressure variation,conductive medium flow rate,and atmosphere condition variation.In this paper,the expression of PFC is built by using quadratic functions to fit the non!inearit>of thermal dynamics.While fitting the model,the environmental condition needs prediction,which is calculated using phase space reconstruction(PSR)Kalman filter.In order to solve the complex quadratic dispatch model,a hybrid following electricity load(FEL)and following thermal load(FTL)mode for reducing the dimension of dispatch model,and a feasible zone analysis(FZA)method are proposed.As a result,the PFC problem of CCHP system is solved,and the dispatch cost,investment cost,and the maximum power requirements are optimized.In this paper,a case in Jinan,China is studied.The PFC model is proven to be more precise and accurate compared with traditional models.展开更多
Based on its prototype of machine-isolator-foundation systems, a theoretical model for dynamic coupled linear system is established, in which both the passive and active control factors are considered. Power flow is u...Based on its prototype of machine-isolator-foundation systems, a theoretical model for dynamic coupled linear system is established, in which both the passive and active control factors are considered. Power flow is used as the cost function to evaluate the isolation effectiveness. And the transmission of vibratory power flow from a vibrating rigid body into a simply supported thin panel through passive isolators and actuators is investigated numerically. The active control strategy is summarized in the conclusion.展开更多
文摘As the demand for more efficient and adaptable power distribution systems intensifies, especially in rural areas, innovative solutions like the Capacitor-Coupled Substation with a Controllable Network Transformer (CCS-CNT) are becoming increasingly critical. Traditional power distribution networks, often limited by unidirectional flow capabilities and inflexibility, struggle to meet the complex demands of modern energy systems. The CCS-CNT system offers a transformative approach by enabling bidirectional power flow between high-voltage transmission lines and local distribution networks, a feature that is essential for integrating renewable energy sources and ensuring reliable electrification in underserved regions. This paper presents a detailed mathematical representation of power flow within the CCS-CNT system, emphasizing the control of both active and reactive power through the adjustment of voltage levels and phase angles. A control algorithm is developed to dynamically manage power flow, ensuring optimal performance by minimizing losses and maintaining voltage stability across the network. The proposed CCS-CNT system demonstrates significant potential in enhancing the efficiency and reliability of power distribution, making it particularly suited for rural electrification and other applications where traditional methods fall short. The findings underscore the system's capability to adapt to varying operational conditions, offering a robust solution for modern power distribution challenges.
文摘A general model of flexible isolation systems which involves both the passive and active control factors is established by inserting actuators into an passive isolation system. And the power flow transmission function in such a system as with multi disturbance, multi mounts, passive isolators and actuators is deduced. By means of the numerical simulation method, the influence of actuators on power flow transmission characteristic is studied. And as a conclusion, the passive active synthetic control strategy of power flow is summarized.
基金Supported by the National Natural Science Foundation under Grant No. 50675177.
文摘L-shaped plates have become an important focuses in structural vibration research. To determine their vibration characteristics, this paper applied a mobility power flow method. Firstly, the L-shaped plate was divided into two substructures to simplify analysis. The coupled bending moment was then deduced by applying a continuous vibration property on the common edge. Next, the response on any point of the plate and the input and transmitted power flow formulas were calculated. Numerical simulations showed the distribution of the coupled bending moment and the response of the whole structure. The validity of this method was verified by the SEA approach.
文摘A novel combined model of the vibration control for the coupled flexiblesystem and its general mathematic description are developed. In presented model, active and passivecontrols as well as force and moment controls are combined into a single unit to achieve theefficient vibration control of the flexible structures by multi-approaches. Considering thecomplexity of the energy transmission in the vibrating system, the transmission channels of thepower flow transmitted into the foundation are discussed, and the general forces and thecorresponding velocities are combined into a single function, respectively. Under the controlstrategy of the minimum power flow, the transmission characteristics of the power flow areinvestigated. From the presented numerical examples, it is obvious that the analytical model iseffective, and both force and moment controls are able to depress vibration energy substantially.
基金the National Natural Science Foundation of China(No.61733010).
文摘Heat exchanger systems(HXSs)or heat recovery steam generators(HRSGs)are commonly used in 100 kW to 50 MW combined cooling,heating,and power(CCHP)systems.Power flow coupling(PFC)is found in HXSs and is complex for researchers to quantify.This could possibly mislead the dispatch schedule and result in the inaccurate dispatch.PFC is caused by the inlet and outlet temperatures of each component,gas flow pressure variation,conductive medium flow rate,and atmosphere condition variation.In this paper,the expression of PFC is built by using quadratic functions to fit the non!inearit>of thermal dynamics.While fitting the model,the environmental condition needs prediction,which is calculated using phase space reconstruction(PSR)Kalman filter.In order to solve the complex quadratic dispatch model,a hybrid following electricity load(FEL)and following thermal load(FTL)mode for reducing the dimension of dispatch model,and a feasible zone analysis(FZA)method are proposed.As a result,the PFC problem of CCHP system is solved,and the dispatch cost,investment cost,and the maximum power requirements are optimized.In this paper,a case in Jinan,China is studied.The PFC model is proven to be more precise and accurate compared with traditional models.
文摘Based on its prototype of machine-isolator-foundation systems, a theoretical model for dynamic coupled linear system is established, in which both the passive and active control factors are considered. Power flow is used as the cost function to evaluate the isolation effectiveness. And the transmission of vibratory power flow from a vibrating rigid body into a simply supported thin panel through passive isolators and actuators is investigated numerically. The active control strategy is summarized in the conclusion.