This study presents a comprehensive impact analysis of the rotor angle stability of a proposed international connection between the Philippines and Sabah,Malaysia,as part of the Association of Southeast Asian Nations(...This study presents a comprehensive impact analysis of the rotor angle stability of a proposed international connection between the Philippines and Sabah,Malaysia,as part of the Association of Southeast Asian Nations(ASEAN)Power Grid.This study focuses on modeling and evaluating the dynamic performance of the interconnected system,considering the high penetration of renewable sources.Power flow,small signal stability,and transient stability analyses were conducted to assess the ability of the proposed linked power system models to withstand small and large disturbances,utilizing the Power Systems Analysis Toolbox(PSAT)software in MATLAB.All components used in the model are documented in the PSAT library.Currently,there is a lack of publicly available studies regarding the implementation of this specific system.Additionally,the study investigates the behavior of a system with a high penetration of renewable energy sources.Based on the findings,this study concludes that a system is generally stable when interconnection is realized,given its appropriate location and dynamic component parameters.Furthermore,the critical eigenvalues of the system also exhibited improvement as the renewable energy sources were augmented.展开更多
The paper proposes a novel H∞ load frequency control(LFC) design method for multi-area power systems based on an integral-based non-fragile distributed fixed-order dynamic output feedback(DOF) tracking-regulator cont...The paper proposes a novel H∞ load frequency control(LFC) design method for multi-area power systems based on an integral-based non-fragile distributed fixed-order dynamic output feedback(DOF) tracking-regulator control scheme. To this end, we consider a nonlinear interconnected model for multiarea power systems which also include uncertainties and timevarying communication delays. The design procedure is formulated using semi-definite programming and linear matrix inequality(LMI) method. The solution of the proposed LMIs returns necessary parameters for the tracking controllers such that the impact of model uncertainty and load disturbances are minimized. The proposed controllers are capable of receiving all or part of subsystems information, whereas the outputs of each controller are local. These controllers are designed such that the resilient stability of the overall closed-loop system is guaranteed. Simulation results are provided to verify the effectiveness of the proposed scheme. Simulation results quantify that the distributed(and decentralized) controlled system behaves well in presence of large parameter perturbations and random disturbances on the power system.展开更多
大规模分布式电源的存在允许配电网通过网络重构改变供电方式,实现部分区域在必要时刻以异步孤岛形式运行。但配电网运行方式的改变必然伴随着关键换流器控制模式的切换和参数的调整,如何平稳地实现配电分区在并网和孤岛之间的转换是实...大规模分布式电源的存在允许配电网通过网络重构改变供电方式,实现部分区域在必要时刻以异步孤岛形式运行。但配电网运行方式的改变必然伴随着关键换流器控制模式的切换和参数的调整,如何平稳地实现配电分区在并网和孤岛之间的转换是实现有源配电网安全可靠运行的重要内容。针对通过软开关(soft open point,SOP)实现柔性互联的配电分区,分析了该系统由并网转为异步孤岛运行的暂态特性,提出了基于参考功率自适应的改进下垂控制策略,并采用状态跟踪方法降低了配电网运行状态切换时刻的暂态波动,实现了配电网运行方式的平滑切换。在PSCAD/EMTDC环境下搭建了仿真模型进行验证,结果表明,所提控制方法可有效提升分区互联有源配电网运行的灵活性。展开更多
For a large-scale high voltage direct current (HVDC)asynchronous interconnected power grid, the frequency issue atthe power sending side under DC faults is a crucial problem.To solve this problem, based on rotor motio...For a large-scale high voltage direct current (HVDC)asynchronous interconnected power grid, the frequency issue atthe power sending side under DC faults is a crucial problem.To solve this problem, based on rotor motion equations, theeffect of unbalanced power on the system frequency under DCfaults is analyzed. The characteristics and dynamic developmentprocess of frequencies after the injection of disturbances areanalyzed. In addition, the actions and coordinated strategies ofvarious frequency control measures are also investigated. Basedon the testing projects of an asynchronous interconnection in theChina Southern Power Grid (CSG), the frequency features arestudied according to the measured PMU data. The outcome showsthat the frequency problem of the Yunnan Power Grid after anasynchronous interconnection can be solved and controlled. Italso shows that the frequency limit control (FLC) is importantfor the frequency regulation of large scale HVDC asynchronousinterconnected DC power grids. As demonstrated, DC FLC caneffectively suppress the deviation of the transient frequency.However, reasonable frequency regulation parameters shouldbe set and other area frequency control measures should becoordinated to maintain the frequency stability of the system.展开更多
A novel low-swing interface circuit for high-speed on-chip asynchronous interconnection is proposed in this paper. It takes a differential level-triggered latch to recover digital signal with ultra low-swing voltage l...A novel low-swing interface circuit for high-speed on-chip asynchronous interconnection is proposed in this paper. It takes a differential level-triggered latch to recover digital signal with ultra low-swing voltage less than 50 mV, and the driver part of the interface circuit is optimized for low power using the driver-array method, With a capacity to work up to 500 MHz, the proposed circuit, which is simulated and fabricated using SMIC 0.18-pm 1.8-V digital CMOS technology, consumes less power than previously reported designs.展开更多
文摘This study presents a comprehensive impact analysis of the rotor angle stability of a proposed international connection between the Philippines and Sabah,Malaysia,as part of the Association of Southeast Asian Nations(ASEAN)Power Grid.This study focuses on modeling and evaluating the dynamic performance of the interconnected system,considering the high penetration of renewable sources.Power flow,small signal stability,and transient stability analyses were conducted to assess the ability of the proposed linked power system models to withstand small and large disturbances,utilizing the Power Systems Analysis Toolbox(PSAT)software in MATLAB.All components used in the model are documented in the PSAT library.Currently,there is a lack of publicly available studies regarding the implementation of this specific system.Additionally,the study investigates the behavior of a system with a high penetration of renewable energy sources.Based on the findings,this study concludes that a system is generally stable when interconnection is realized,given its appropriate location and dynamic component parameters.Furthermore,the critical eigenvalues of the system also exhibited improvement as the renewable energy sources were augmented.
文摘The paper proposes a novel H∞ load frequency control(LFC) design method for multi-area power systems based on an integral-based non-fragile distributed fixed-order dynamic output feedback(DOF) tracking-regulator control scheme. To this end, we consider a nonlinear interconnected model for multiarea power systems which also include uncertainties and timevarying communication delays. The design procedure is formulated using semi-definite programming and linear matrix inequality(LMI) method. The solution of the proposed LMIs returns necessary parameters for the tracking controllers such that the impact of model uncertainty and load disturbances are minimized. The proposed controllers are capable of receiving all or part of subsystems information, whereas the outputs of each controller are local. These controllers are designed such that the resilient stability of the overall closed-loop system is guaranteed. Simulation results are provided to verify the effectiveness of the proposed scheme. Simulation results quantify that the distributed(and decentralized) controlled system behaves well in presence of large parameter perturbations and random disturbances on the power system.
文摘大规模分布式电源的存在允许配电网通过网络重构改变供电方式,实现部分区域在必要时刻以异步孤岛形式运行。但配电网运行方式的改变必然伴随着关键换流器控制模式的切换和参数的调整,如何平稳地实现配电分区在并网和孤岛之间的转换是实现有源配电网安全可靠运行的重要内容。针对通过软开关(soft open point,SOP)实现柔性互联的配电分区,分析了该系统由并网转为异步孤岛运行的暂态特性,提出了基于参考功率自适应的改进下垂控制策略,并采用状态跟踪方法降低了配电网运行状态切换时刻的暂态波动,实现了配电网运行方式的平滑切换。在PSCAD/EMTDC环境下搭建了仿真模型进行验证,结果表明,所提控制方法可有效提升分区互联有源配电网运行的灵活性。
文摘For a large-scale high voltage direct current (HVDC)asynchronous interconnected power grid, the frequency issue atthe power sending side under DC faults is a crucial problem.To solve this problem, based on rotor motion equations, theeffect of unbalanced power on the system frequency under DCfaults is analyzed. The characteristics and dynamic developmentprocess of frequencies after the injection of disturbances areanalyzed. In addition, the actions and coordinated strategies ofvarious frequency control measures are also investigated. Basedon the testing projects of an asynchronous interconnection in theChina Southern Power Grid (CSG), the frequency features arestudied according to the measured PMU data. The outcome showsthat the frequency problem of the Yunnan Power Grid after anasynchronous interconnection can be solved and controlled. Italso shows that the frequency limit control (FLC) is importantfor the frequency regulation of large scale HVDC asynchronousinterconnected DC power grids. As demonstrated, DC FLC caneffectively suppress the deviation of the transient frequency.However, reasonable frequency regulation parameters shouldbe set and other area frequency control measures should becoordinated to maintain the frequency stability of the system.
基金the 973 Program of China (Grant No.G1999032903)the National Science Fund for Distinguished Young Scholars (Grant No.60025101)the Major Program of National Natural Science Foundation of China (Grant No.90707002)
文摘A novel low-swing interface circuit for high-speed on-chip asynchronous interconnection is proposed in this paper. It takes a differential level-triggered latch to recover digital signal with ultra low-swing voltage less than 50 mV, and the driver part of the interface circuit is optimized for low power using the driver-array method, With a capacity to work up to 500 MHz, the proposed circuit, which is simulated and fabricated using SMIC 0.18-pm 1.8-V digital CMOS technology, consumes less power than previously reported designs.