A terahertz-wave generator based on optical parametric oscillator principle, detection based on combination of Fizeau wedged interferometer and an electro-optical crystal ZnTe has been studied. The analytical solution...A terahertz-wave generator based on optical parametric oscillator principle, detection based on combination of Fizeau wedged interferometer and an electro-optical crystal ZnTe has been studied. The analytical solution based on the basic principle of operation of solid wedge Fizeau interferometer has been realized. The mathematical calculations for THz frequency and intensity measurement dependent on wedge angle and fringe spacing have been considered. The efficiency of THz wave detection depends upon optimized wedge angle has been also realized. The feasibility of detection of THz waves' frequency and intensity by solid Fizeau interferometer (THz-waves' range of 1 - 3 THz) has been studied. By optimization of other parameters like thickness of Fizeau film, refractive index, material of Fizeau film, we can proceed towards the design of Fizeau interferometer for required research plans as it is a simple and inexpensive interferometer.展开更多
在高精度平面干涉仪系统评价标准中,仪器传递函数(Instrument Transfer Function,ITF)已经逐渐成为干涉仪性能的重要评价指标,它准确地反映了光学系统对于测量形貌不同空间频率的分辨能力。然而,ITF测试过程中的实验环境要求较为严格,...在高精度平面干涉仪系统评价标准中,仪器传递函数(Instrument Transfer Function,ITF)已经逐渐成为干涉仪性能的重要评价指标,它准确地反映了光学系统对于测量形貌不同空间频率的分辨能力。然而,ITF测试过程中的实验环境要求较为严格,干涉仪系统噪声会导致测试结果产生较大失真。为了能够准确表征干涉仪系统的性能,通过仿真分析与实际实验结合的方式,将仿真干涉图引入不同量级的高斯随机噪声,探究了噪声对于ITF测试结果的影响,提出测试误差的评价指标ITF_(RMS)值,分析了干涉仪系统的噪声容限,依据评价指标提出了几种不同的ITF测试优化方法,并搭建实验系统进行分析验证。实验结果表明,在未优化的ITF测试流程中,所搭建的干涉仪系统ITF测试的ITF_(RMS)值为0.1112,而优化后同样噪声量级的干涉仪系统所得ITF_(RMS)值则分别降至0.0693,0.0367,0.0579。此结果证明了优化方案的可行性,该方案能有效抑制干涉仪系统ITF测试过程中的噪声干扰影响。展开更多
In this study,we present a dual-Fizeau-interferometer-based high-speed and wide-range fiber-optic Fabry-Perot(F-P)demodulation system.We employ two Fizeau interferometers with air cavity thickness satisfying the quadr...In this study,we present a dual-Fizeau-interferometer-based high-speed and wide-range fiber-optic Fabry-Perot(F-P)demodulation system.We employ two Fizeau interferometers with air cavity thickness satisfying the quadrature requirement to increase the demodulation speed and broaden the demodulation range in order to address the issues of the existing fiber F-P demodulation system's sluggish demodulation rate and limited range.In order to investigate the demodulation properties of the dual-Fizeau-interferometer-based demodulation system,we derive and create a theoretical model of the system.The theoretical model,which primarily consists of the structural design of the interferometer and the study of the center wavelength of the light sources and their bandwidth selection,is used to construct the optical structure of the demodulation system.According to the calculation results,the demodulated signal exhibits the best contrast ratio when the two light sources'respective center wavelengths are 780nm and 850nm,and their bandwidths are 28nm and 30 nm.Finally,we finish evaluating the demodulation system's demodulation performance,parameter calibration,and assembly debugging.The test results demonstrate the constant operation of the demodulation system,an update rate of 100kHz,a demodulation range of 4.74μm,and a cavity length resolution of approximately 5 nm.Additionally,the system can perform high speed demodulation thanks to the light emitting diode's(LED's)nanosecond level switching speed and the usage of a single point detector.展开更多
Tilted Wave Interferometry(TWI)is a measurement technique for fast and flexible interferometric testing of aspheres and freeform surfaces.The first version of the tilted wave principle was implemented in a Twyman-Gree...Tilted Wave Interferometry(TWI)is a measurement technique for fast and flexible interferometric testing of aspheres and freeform surfaces.The first version of the tilted wave principle was implemented in a Twyman-Green type setup with separate reference arm,which is intrinsically susceptible to environmentally induced phase disturbances.In this contribution we present the TWI in a new robust common-path(Fizeau)configuration.The implementation of the Tilted Wave Fizeau Interferometer requires a new approach in illumination,calibration and evaluation.Measurements of two aspheres and a freeform surface show the flexibility and also the increased stability in both phase raw data and surface measurements,which leads to a reduced repeatability up to a factor of three.The novel configuration significantly relaxes the tolerances of the imaging optics used in the interferometer.We demonstrate this using simulations on calibration measurements,where we see an improvement of one order of magnitude compared to the classical Twyman-Green TWI approach and the capability to compensate higher order error contributions on the used optics.展开更多
文摘A terahertz-wave generator based on optical parametric oscillator principle, detection based on combination of Fizeau wedged interferometer and an electro-optical crystal ZnTe has been studied. The analytical solution based on the basic principle of operation of solid wedge Fizeau interferometer has been realized. The mathematical calculations for THz frequency and intensity measurement dependent on wedge angle and fringe spacing have been considered. The efficiency of THz wave detection depends upon optimized wedge angle has been also realized. The feasibility of detection of THz waves' frequency and intensity by solid Fizeau interferometer (THz-waves' range of 1 - 3 THz) has been studied. By optimization of other parameters like thickness of Fizeau film, refractive index, material of Fizeau film, we can proceed towards the design of Fizeau interferometer for required research plans as it is a simple and inexpensive interferometer.
文摘在高精度平面干涉仪系统评价标准中,仪器传递函数(Instrument Transfer Function,ITF)已经逐渐成为干涉仪性能的重要评价指标,它准确地反映了光学系统对于测量形貌不同空间频率的分辨能力。然而,ITF测试过程中的实验环境要求较为严格,干涉仪系统噪声会导致测试结果产生较大失真。为了能够准确表征干涉仪系统的性能,通过仿真分析与实际实验结合的方式,将仿真干涉图引入不同量级的高斯随机噪声,探究了噪声对于ITF测试结果的影响,提出测试误差的评价指标ITF_(RMS)值,分析了干涉仪系统的噪声容限,依据评价指标提出了几种不同的ITF测试优化方法,并搭建实验系统进行分析验证。实验结果表明,在未优化的ITF测试流程中,所搭建的干涉仪系统ITF测试的ITF_(RMS)值为0.1112,而优化后同样噪声量级的干涉仪系统所得ITF_(RMS)值则分别降至0.0693,0.0367,0.0579。此结果证明了优化方案的可行性,该方案能有效抑制干涉仪系统ITF测试过程中的噪声干扰影响。
文摘In this study,we present a dual-Fizeau-interferometer-based high-speed and wide-range fiber-optic Fabry-Perot(F-P)demodulation system.We employ two Fizeau interferometers with air cavity thickness satisfying the quadrature requirement to increase the demodulation speed and broaden the demodulation range in order to address the issues of the existing fiber F-P demodulation system's sluggish demodulation rate and limited range.In order to investigate the demodulation properties of the dual-Fizeau-interferometer-based demodulation system,we derive and create a theoretical model of the system.The theoretical model,which primarily consists of the structural design of the interferometer and the study of the center wavelength of the light sources and their bandwidth selection,is used to construct the optical structure of the demodulation system.According to the calculation results,the demodulated signal exhibits the best contrast ratio when the two light sources'respective center wavelengths are 780nm and 850nm,and their bandwidths are 28nm and 30 nm.Finally,we finish evaluating the demodulation system's demodulation performance,parameter calibration,and assembly debugging.The test results demonstrate the constant operation of the demodulation system,an update rate of 100kHz,a demodulation range of 4.74μm,and a cavity length resolution of approximately 5 nm.Additionally,the system can perform high speed demodulation thanks to the light emitting diode's(LED's)nanosecond level switching speed and the usage of a single point detector.
文摘Tilted Wave Interferometry(TWI)is a measurement technique for fast and flexible interferometric testing of aspheres and freeform surfaces.The first version of the tilted wave principle was implemented in a Twyman-Green type setup with separate reference arm,which is intrinsically susceptible to environmentally induced phase disturbances.In this contribution we present the TWI in a new robust common-path(Fizeau)configuration.The implementation of the Tilted Wave Fizeau Interferometer requires a new approach in illumination,calibration and evaluation.Measurements of two aspheres and a freeform surface show the flexibility and also the increased stability in both phase raw data and surface measurements,which leads to a reduced repeatability up to a factor of three.The novel configuration significantly relaxes the tolerances of the imaging optics used in the interferometer.We demonstrate this using simulations on calibration measurements,where we see an improvement of one order of magnitude compared to the classical Twyman-Green TWI approach and the capability to compensate higher order error contributions on the used optics.