With the technology of coincidence method, transit time spreads (TTSs) of PMTs are measured with Cherenkov light on the photocathode window of photomultiplier tube (PMT) produced by cascade γ radiation source, 60Co. ...With the technology of coincidence method, transit time spreads (TTSs) of PMTs are measured with Cherenkov light on the photocathode window of photomultiplier tube (PMT) produced by cascade γ radiation source, 60Co. TTSs with single and multi-photoelectron which are analyzed by convolution of Poisson and Gaussian are obtained. The study to XP2020 and XP2020Q PMTs shows that TTSs are consistent with data supplied by Philips. TTSs are inversely proportional to the square roots of number of photoelectrons. The method is feasible when single and multi-photoelectron can be distinguished.展开更多
The water Cherenkov detector array(WCDA) is an important part of the large high-altitude air shower observatory(LHAASO),which is in a research and development phase.The central scientific goal of LHAASO is to explore ...The water Cherenkov detector array(WCDA) is an important part of the large high-altitude air shower observatory(LHAASO),which is in a research and development phase.The central scientific goal of LHAASO is to explore the origin of high-energy cosmic rays of the universe and to push forward the frontier of new physics.To simplify the WCDA's readout electronics,a prototype of a front-end readout for an application-specific integrated circuit(ASIC) is designed based on the timeover-threshold method to achieve charge-to-time conversion.High-precision time measurement and charge measurement are necessary over a full dynamic range[1-4000photoelectrons(P.E.)].To evaluate the performance of this ASIC,a test system is designed that includes the front-end ASIC test module,digitization module,and test software.The first module needs to be customized for different ASIC versions,whereas the digitization module and test software are tested for general-purpose use.In the digitization module,a field programmable gate array-based time-todigital converter is designed with a bin size of 333 ps,which also integrates an inter-integrated circuit to configure the ASIC test module,and a universal serial bus interface is designed to transfer data to the remote computer.Test results indicate that the time resolution is better than 0.5 ns,and the charge resolution is better than 30%root mean square(RMS) at 1 P.E.and 3%RMS at 4000 P.E.,which are beyond the application requirements.展开更多
High precision time measurement is required in the readout of the neutron wall and TOF walls in the external target experiment of the Cooling Storage Ring(CSR) project in the Heavy Ion Research Facility in Lanzhou(HIR...High precision time measurement is required in the readout of the neutron wall and TOF walls in the external target experiment of the Cooling Storage Ring(CSR) project in the Heavy Ion Research Facility in Lanzhou(HIRFL).Considering the time walk correction,both time and charge are measured in the readout electronics.In this 16-channel measurement module,time and charge information are digitized by TDCs at the same time based on the Time-Over-Threshold(TOT) method;meanwhile,by employing high-density ASIC chips,the electronics complexity is effectively reduced.Test results indicate that this module achieves a time resolution better than 25 ps and a charge resolution better than 5%over the input amplitude range from 50 mV to 3V.展开更多
文摘With the technology of coincidence method, transit time spreads (TTSs) of PMTs are measured with Cherenkov light on the photocathode window of photomultiplier tube (PMT) produced by cascade γ radiation source, 60Co. TTSs with single and multi-photoelectron which are analyzed by convolution of Poisson and Gaussian are obtained. The study to XP2020 and XP2020Q PMTs shows that TTSs are consistent with data supplied by Philips. TTSs are inversely proportional to the square roots of number of photoelectrons. The method is feasible when single and multi-photoelectron can be distinguished.
基金supported by Gansu Province Higher Education Industry Support Plan Project(No.2023CYZC-40)Lanzhou Science and Technology Development Plan Project(No.2023-3-104)。
基金supported by the Knowledge Innovation Program of the Chinese Academy of Sciences(KJCX2-YW-N27)the CAS Center for Excellence in Particle Physics(CCEPP)
文摘The water Cherenkov detector array(WCDA) is an important part of the large high-altitude air shower observatory(LHAASO),which is in a research and development phase.The central scientific goal of LHAASO is to explore the origin of high-energy cosmic rays of the universe and to push forward the frontier of new physics.To simplify the WCDA's readout electronics,a prototype of a front-end readout for an application-specific integrated circuit(ASIC) is designed based on the timeover-threshold method to achieve charge-to-time conversion.High-precision time measurement and charge measurement are necessary over a full dynamic range[1-4000photoelectrons(P.E.)].To evaluate the performance of this ASIC,a test system is designed that includes the front-end ASIC test module,digitization module,and test software.The first module needs to be customized for different ASIC versions,whereas the digitization module and test software are tested for general-purpose use.In the digitization module,a field programmable gate array-based time-todigital converter is designed with a bin size of 333 ps,which also integrates an inter-integrated circuit to configure the ASIC test module,and a universal serial bus interface is designed to transfer data to the remote computer.Test results indicate that the time resolution is better than 0.5 ns,and the charge resolution is better than 30%root mean square(RMS) at 1 P.E.and 3%RMS at 4000 P.E.,which are beyond the application requirements.
基金Supported by the Knowledge Innovation Program of the Chinese Academy of Sciences(No.KJCX2-YW-N27)the National Natural Science Foundation of China(No.11079003)
文摘High precision time measurement is required in the readout of the neutron wall and TOF walls in the external target experiment of the Cooling Storage Ring(CSR) project in the Heavy Ion Research Facility in Lanzhou(HIRFL).Considering the time walk correction,both time and charge are measured in the readout electronics.In this 16-channel measurement module,time and charge information are digitized by TDCs at the same time based on the Time-Over-Threshold(TOT) method;meanwhile,by employing high-density ASIC chips,the electronics complexity is effectively reduced.Test results indicate that this module achieves a time resolution better than 25 ps and a charge resolution better than 5%over the input amplitude range from 50 mV to 3V.