A sewage heat pump system and its application based on a project in Chongqing,China,were discussed. Based on the sewage conditions,a feasibility analysis of the sewage heat pump air conditioning system was conducted. ...A sewage heat pump system and its application based on a project in Chongqing,China,were discussed. Based on the sewage conditions,a feasibility analysis of the sewage heat pump air conditioning system was conducted. The theoretical and quantitative calculations indicate that sewage flux in the city sewage main pipe in the project can satisfy heat exchange requirements,and taking water from the pipes has relatively small influence on the pipe net in summer and winter. The sewage heat pump air-conditioning system can save 21.5% operating cost in one year,which is energy efficient and environmentally friendly.展开更多
The exergy analysis and finite time thermodynamic methods had been employed to analyze the compound condensation process (CCP). It was based on the air-cooling heat pump unit. The cooling capacity of the chiller unit ...The exergy analysis and finite time thermodynamic methods had been employed to analyze the compound condensation process (CCP). It was based on the air-cooling heat pump unit. The cooling capacity of the chiller unit is about 1 kW, and the work refrigerant is R22/R407C/R410A/CO2. The MATLAB/SIMULINK software was employed to build the simulation model. The thermodynamic simulation model is significant for the optimization of parameters of the unit, such as condensation and evaporation temperature and mass flow of the sanitary hot water and size of hot water storage tank. The COP of the CCP of R410A system is about 3% - 5% higher than the CCP of the R22 system, while CCP of the R407C system is a little lower than the CCP of R22 system. And the CCP of CO2 trans-critical system has advantage in the hot supply mode. The simulation method provided a theoretical reference for developing the production of CCP with substitute refrigerant R407C/R410A/CO2.展开更多
An air source heat pump(ASHP)with refrigerant injection is proposed for the air conditioning system of electric vehicles(EVs),especially for efficient heating in cold winter,when there is no wasted heat of engines.The...An air source heat pump(ASHP)with refrigerant injection is proposed for the air conditioning system of electric vehicles(EVs),especially for efficient heating in cold winter,when there is no wasted heat of engines.The simulation model is built with the framework of two-phase fluid network,where the compressor is separated as two compressors and the economizer is treated as two heat exchangers in the injection path and the main refrigerant path.With the validated simulation model,the heating performance is analyzed,and the results show that the coefficient of performance(COP)of ASHP with refrigerant injection is higher than 1.4 and the discharge temperature is less than 100℃ when the outdoor temperature is-20℃.The above performance ensures that the air conditioning system and EVs can operate normally with high efficiency even in the cold winter,which is much helpful for the practicability of EVs.展开更多
Energy-saving air-conditioner with hot water is an air source heat pump air-conditioner,which can also supply hot water.The hot water is heated by a double pipe condenser connected with an air-cooled condenser in seri...Energy-saving air-conditioner with hot water is an air source heat pump air-conditioner,which can also supply hot water.The hot water is heated by a double pipe condenser connected with an air-cooled condenser in series in the system.This experiment of the energy-saving air-conditioner was carried out in the enthalpy-difference air-conditioner laboratory.The hot water temperature and the compressor's discharge and suction pressure were recorded in the working condition,where the ambient temperature was at 43 ℃,35 ℃,21 ℃,7 ℃,and 2 ℃ separately.The results showed that the system operated stably and reliably.This system can supply 240 L hot water at 50 ℃ in the whole year,and its coefficience of performance(COP)is much higher than the conventional air source heat pump system.Its energy conservation was proved by comparing the thermal efficiency with other sourece water heaters.展开更多
The application of air conditioning heat pump(ACHP) in electric vehicles could lead to significant electrical power saving effect. As for an air conditioning heat pump system for electric vehicles, the influence of re...The application of air conditioning heat pump(ACHP) in electric vehicles could lead to significant electrical power saving effect. As for an air conditioning heat pump system for electric vehicles, the influence of refrigerant charge amount should be investigated during the design phase. In this study, experimental method was employed to investigate the influence of the refrigerant charge amount on the performance of the ACHP system. The results showed that the refrigerant charge amount had different influence on the refrigerant properties at various locations within the system. The coefficient of performance and pressure-enthalpy diagram were calculated, and showed a close relationship with refrigerant charge amount under different compressor speeds. The degree of subcooling and the degree of superheating were recorded and the critical charge amount was determined by a typical practical test method. In addition, the critical refrigerant charge amount determined by the experimental method was also compared with two typical void fraction correlation models, and the model with consideration of two phase stream reaction of the refrigerant showed a good estimation accuracy on the critical charge amount.展开更多
以增程式电动汽车为研究对象,与热泵空调技术相结合,设计可利用发动机余热、电驱系统余热、PTC(positive temperature coefficient)、车外空气等多种热源的乘员舱制热方案。制定乘员舱多热源制热控制策略,搭建AMESim和Simulink联合仿真...以增程式电动汽车为研究对象,与热泵空调技术相结合,设计可利用发动机余热、电驱系统余热、PTC(positive temperature coefficient)、车外空气等多种热源的乘员舱制热方案。制定乘员舱多热源制热控制策略,搭建AMESim和Simulink联合仿真模型,对方案和策略进行仿真分析。仿真结果表明:在有余热利用的情况下,乘员舱制热优先选取发动机余热回收模式,其次选择电驱余热回收热泵模式;在无余热利用情况下,-10℃及以上温度选择空气源热泵制热,-10℃以下选择PTC进行制热。将多热源集成式制热策略与PTC单独制热、空气源热泵制热策略进行对比分析,结果表明:在不同环境温度下多热源集成式制热策略总能耗均最低,在环境温度为-20℃时,集成式制热能耗比PTC制热能耗降低32.1%,比空气源热泵制热能耗降低50.7%。展开更多
基金Project(50838009) supported by the National Natural Science Foundation of ChinaProjects(2006BAJ02A09+1 种基金2006BAJ02A13-4) supported by the National Key Technologies R&D ProgramProject(2006BAJ01A06-3) supported by the Key R & D Program during the Eleventh Five-Year Plan Period,China
文摘A sewage heat pump system and its application based on a project in Chongqing,China,were discussed. Based on the sewage conditions,a feasibility analysis of the sewage heat pump air conditioning system was conducted. The theoretical and quantitative calculations indicate that sewage flux in the city sewage main pipe in the project can satisfy heat exchange requirements,and taking water from the pipes has relatively small influence on the pipe net in summer and winter. The sewage heat pump air-conditioning system can save 21.5% operating cost in one year,which is energy efficient and environmentally friendly.
文摘The exergy analysis and finite time thermodynamic methods had been employed to analyze the compound condensation process (CCP). It was based on the air-cooling heat pump unit. The cooling capacity of the chiller unit is about 1 kW, and the work refrigerant is R22/R407C/R410A/CO2. The MATLAB/SIMULINK software was employed to build the simulation model. The thermodynamic simulation model is significant for the optimization of parameters of the unit, such as condensation and evaporation temperature and mass flow of the sanitary hot water and size of hot water storage tank. The COP of the CCP of R410A system is about 3% - 5% higher than the CCP of the R22 system, while CCP of the R407C system is a little lower than the CCP of R22 system. And the CCP of CO2 trans-critical system has advantage in the hot supply mode. The simulation method provided a theoretical reference for developing the production of CCP with substitute refrigerant R407C/R410A/CO2.
基金supported by the National Key Research and Development Program of China(No.2016YFB0601602)National Natural Science Foundation of China(No.51676199)
文摘An air source heat pump(ASHP)with refrigerant injection is proposed for the air conditioning system of electric vehicles(EVs),especially for efficient heating in cold winter,when there is no wasted heat of engines.The simulation model is built with the framework of two-phase fluid network,where the compressor is separated as two compressors and the economizer is treated as two heat exchangers in the injection path and the main refrigerant path.With the validated simulation model,the heating performance is analyzed,and the results show that the coefficient of performance(COP)of ASHP with refrigerant injection is higher than 1.4 and the discharge temperature is less than 100℃ when the outdoor temperature is-20℃.The above performance ensures that the air conditioning system and EVs can operate normally with high efficiency even in the cold winter,which is much helpful for the practicability of EVs.
基金Supported by Leading Academic Discipline Project of Shanghai Municipal Education Commission(J50502)
文摘Energy-saving air-conditioner with hot water is an air source heat pump air-conditioner,which can also supply hot water.The hot water is heated by a double pipe condenser connected with an air-cooled condenser in series in the system.This experiment of the energy-saving air-conditioner was carried out in the enthalpy-difference air-conditioner laboratory.The hot water temperature and the compressor's discharge and suction pressure were recorded in the working condition,where the ambient temperature was at 43 ℃,35 ℃,21 ℃,7 ℃,and 2 ℃ separately.The results showed that the system operated stably and reliably.This system can supply 240 L hot water at 50 ℃ in the whole year,and its coefficience of performance(COP)is much higher than the conventional air source heat pump system.Its energy conservation was proved by comparing the thermal efficiency with other sourece water heaters.
基金supported by The Open Project Program of State Key Laboratory of Fire Science (No. HZ2018-KF03)Shanghai Sailing Program (No. 18YF1417900)Huaqiao University Scientific Research Foundation (No. 16BS801)
文摘The application of air conditioning heat pump(ACHP) in electric vehicles could lead to significant electrical power saving effect. As for an air conditioning heat pump system for electric vehicles, the influence of refrigerant charge amount should be investigated during the design phase. In this study, experimental method was employed to investigate the influence of the refrigerant charge amount on the performance of the ACHP system. The results showed that the refrigerant charge amount had different influence on the refrigerant properties at various locations within the system. The coefficient of performance and pressure-enthalpy diagram were calculated, and showed a close relationship with refrigerant charge amount under different compressor speeds. The degree of subcooling and the degree of superheating were recorded and the critical charge amount was determined by a typical practical test method. In addition, the critical refrigerant charge amount determined by the experimental method was also compared with two typical void fraction correlation models, and the model with consideration of two phase stream reaction of the refrigerant showed a good estimation accuracy on the critical charge amount.
文摘以增程式电动汽车为研究对象,与热泵空调技术相结合,设计可利用发动机余热、电驱系统余热、PTC(positive temperature coefficient)、车外空气等多种热源的乘员舱制热方案。制定乘员舱多热源制热控制策略,搭建AMESim和Simulink联合仿真模型,对方案和策略进行仿真分析。仿真结果表明:在有余热利用的情况下,乘员舱制热优先选取发动机余热回收模式,其次选择电驱余热回收热泵模式;在无余热利用情况下,-10℃及以上温度选择空气源热泵制热,-10℃以下选择PTC进行制热。将多热源集成式制热策略与PTC单独制热、空气源热泵制热策略进行对比分析,结果表明:在不同环境温度下多热源集成式制热策略总能耗均最低,在环境温度为-20℃时,集成式制热能耗比PTC制热能耗降低32.1%,比空气源热泵制热能耗降低50.7%。