Unmanned Aerial Vehicles(UAvs)as aerial base stations to provide communication services for ground users is a flexible and cost-effective paradigm in B5G.Besides,dynamic resource allocation and multi-connectivity can ...Unmanned Aerial Vehicles(UAvs)as aerial base stations to provide communication services for ground users is a flexible and cost-effective paradigm in B5G.Besides,dynamic resource allocation and multi-connectivity can be adopted to further harness the potentials of UAVs in improving communication capacity,in such situations such that the interference among users becomes a pivotal disincentive requiring effective solutions.To this end,we investigate the Joint UAV-User Association,Channel Allocation,and transmission Power Control(J-UACAPC)problem in a multi-connectivity-enabled UAV network with constrained backhaul links,where each UAV can determine the reusable channels and transmission power to serve the selected ground users.The goal was to mitigate co-channel interference while maximizing long-term system utility.The problem was modeled as a cooperative stochastic game with hybrid discrete-continuous action space.A Multi-Agent Hybrid Deep Reinforcement Learning(MAHDRL)algorithm was proposed to address this problem.Extensive simulation results demonstrated the effectiveness of the proposed algorithm and showed that it has a higher system utility than the baseline methods.展开更多
DC-inverter split air-conditioner is widely used in Chinese homes as a result of its high-efficiency and energy-saving. Recently, the researches on its outdoor unit have focused on the influence of surrounding structu...DC-inverter split air-conditioner is widely used in Chinese homes as a result of its high-efficiency and energy-saving. Recently, the researches on its outdoor unit have focused on the influence of surrounding structures upon the aerodynamic and acoustic performance, however they are only limited to the influence of a few parameters on the performance, and practical design of the unit requires more detailed parametric analysis. Three-dimensional computational fluid dynamics(CFD) and computational aerodynamic acoustics(CAA) simulation based on FLUENT solver is used to study the influence of surrounding structures upon the aforementioned properties of the unit. The flow rate and sound pressure level are predicted for different rotating speed, and agree well with the experimental results. The parametric influence of three main surrounding structures(i.e. the heat sink, the bell-mouth type shroud and the outlet grille) upon the aerodynamic performance of the unit is analyzed thoroughly. The results demonstrate that the tip vortex plays a major role in the flow fields near the blade tip and has a great effect on the flow field of the unit. The inlet ring's size and throat's depth of the bell-mouth type shroud, and the through-flow area and configuration of upwind and downwind sections of the outlet grille are the most important factors that affect the aerodynamic performance of the unit. Furthermore, two improved schemes against the existing prototype of the unit are developed, which both can significantly increase the flow rate more than 6 %(i.e. 100 m3·h~(-1)) at given rotating speeds. The inevitable increase of flow noise level when flow rate is increased and the advantage of keeping a lower rotating speed are also discussed. The presented work could be a useful guideline in designing the aerodynamic and acoustic performance of the split air-conditioner in engineering practice.展开更多
In this paper, we investigate the Toeplitz operators with positive measure symbols on the Bergman spaces of bounded multi-connected domains and show that a Toeplitz operator is bounded or compact if and only if the sy...In this paper, we investigate the Toeplitz operators with positive measure symbols on the Bergman spaces of bounded multi-connected domains and show that a Toeplitz operator is bounded or compact if and only if the symbol measure is a Carleson or vanishing Carleson measure respectively.展开更多
China is the largest producer and consumer of hydrochlorofluorocarbons (HCFCs), and the production of HCFC-22 accounts for more than 80% of all HCFCs. This paper concentrates on the residential air-conditioner indus...China is the largest producer and consumer of hydrochlorofluorocarbons (HCFCs), and the production of HCFC-22 accounts for more than 80% of all HCFCs. This paper concentrates on the residential air-conditioner industry and analyzes the environmental benefits of accelerating the phase-out of HCFC-22 in China. According to the comparison of the baseline and phase-out scenarios of HCFC-22, the findings show that using HC-290 (propane) as a refrigerant alternative will directly reduce the greenhouse effect, and indirectly reduce the emission of greenhouse gases due to a reduction in the electricity consumption. The comparison of two scenarios of HC-290 and HFC-410A refrigerant alternatives shows that the use of HC-290 refrigerant will produce significantly higher environmental benefits than the HFC-410A refrigerant.展开更多
HFC-134a is the most important alternative to CFC-12 used in the mobile air-conditioner sector in China. The con- sumption of HFC-134a has been increasing rapidly in recent years. It becomes the most consumed HFC in t...HFC-134a is the most important alternative to CFC-12 used in the mobile air-conditioner sector in China. The con- sumption of HFC-134a has been increasing rapidly in recent years. It becomes the most consumed HFC in the sector. Selecting 2005 as the base line year, future consumption and emission amounts of HFC-134a are estimated through an analysis of a combined scenario: 1) replacement by non-HFC-134a blends, 2) good practice in servicing, 3) technology promotion, and 4) government policies on control of HFC-134a emissions. The analysis shows that HFC-134a consumption and emissions will continue to increase in the next 10 years. The projected HFC-134a consumption will approach 20,150 t and 34,875 t in 2010 and 2015 respectively, while the estimated emission amounts will reach 16,065 t and 30,186 t (i.e., 21 Mt CO2-eq and 39 Mt CO2-eq emissions) correspondingly. Compared with the business-as-usual scenario, the expected emission reductions in 2010 and 2015 will range between 6.7 Mt CO2-eq and 13.0 Mt CO2-eq.展开更多
This paper studies the influence of a finite container on an ideal gas.The trace of the heat kernel (t) =exp, where are the eigenvalues of the negative Laplacian -in Rn(n = 2 or 3), is studied for a general multi-conn...This paper studies the influence of a finite container on an ideal gas.The trace of the heat kernel (t) =exp, where are the eigenvalues of the negative Laplacian -in Rn(n = 2 or 3), is studied for a general multi-connected bounded drum ft which is surrounded by simply connected bounded domains Ωi with smooth boundaries Ωi(i = 1,… ,m) where the Dirichlet, Neumann and Robin boundary conditions on Ωi(i = 1,…,m) are considered. Some geometrical properties of Ω are determined. The thermodynamic quantities for an ideal gas enclosed in Ω are examined by using the asymptotic expansions of (t) for short-time t. It is shown that the ideal gas can not feel the shape of its container Ω, although it can feel some geometrical properties of it.展开更多
In order to expand the natural energy and the energy conservation, "the smart PV (photovoltaic power generation) & EV (electric vehicle) system" has been proposed and the effect has been clarified. In the smart...In order to expand the natural energy and the energy conservation, "the smart PV (photovoltaic power generation) & EV (electric vehicle) system" has been proposed and the effect has been clarified. In the smart PV & EV system, it is important that electric vehicles become popular. Therefore, the AI-EV (air-conditioner integrated electric vehicle) has been proposed. In this paper, the AI-EV is designed based on the required car air-conditioner capacity. And, the value of AI-EV is compared with a gasoline vehicle, HV (hybrid vehicle) and EV using the mathematical simulation model As a result, it is clarified that the minimum displacement of the small-engine is 120 cc for AI-EV. In the smart PV & EV system, AI-EV can reduce CO_2 emissions by 20% almost the same as EV. Additionally, AI-EV is able to gain the cruising range more than twice as long as EV.展开更多
Aim: To investigate the effect of air-conditioner exposure on semen quality. Methods: The data came from the healthy male volunteers, aged 22 to 30 years, who went to centers for maternity and children health for prem...Aim: To investigate the effect of air-conditioner exposure on semen quality. Methods: The data came from the healthy male volunteers, aged 22 to 30 years, who went to centers for maternity and children health for premarital physical examination in Shanghai, Henan, Zhejiang and Hebei from December 1998 to February 2000. The sampling size is 304. Results: Among the subjects, 90 (29.6 %) had air-conditioner at home and the rest did not. X2-test and multiple logistic regression analyses showed that, the difference between the exposure and control groups was statistically significant in semen volume, sperm density and proportion of sperm with normal morphology. The three indexes were lower in the exposure group. Conclusion: Air-conditioner exposure possibly influences the semen quality.展开更多
The increasing demand for industrial automation and intelligence has put forward higher requirements for the reliability of industrial wireless communication technology.As an international standard based on 802.11,Wir...The increasing demand for industrial automation and intelligence has put forward higher requirements for the reliability of industrial wireless communication technology.As an international standard based on 802.11,Wireless networks for Industrial Automation-Factory Automation(WIA-FA)greatly improves the reliability in factory automation scenarios by Time Division Multiple Access(TDMA).However,in ultra-dense WIA-FA networks with mobile users,the basic connection management mechanism is inefficient.Most of the handover and resource management algorithms are all based on frequency division multiplexing,not suitable for the TDMA in the WIA-FA network.Therefore,we propose Load-aware Connection Management(LACM)algorithm to adjust the linkage and balance the load of access devices to avoid blocking and improve the reliability of the system.And then we simulate the algorithm to find the optimal settings of the parameters.After comparing with other existing algorithms,the result of the simulation proves that LACM is more efficient in reliability and maintains high reliability of more than 99.8%even in the ultra-dense moving scenario with 1500 field devices.Besides,this algorithm ensures that only a few signaling exchanges are required to ensure load bal-ancing,which is no more than 5 times,and less than half of the best state-of-the-art algorithm.展开更多
To explore the relationship between summer office set air-conditioning temperature and energy consumption related to air conditioning use to provide human thermal comfort,a comparison experiment was conducted in three...To explore the relationship between summer office set air-conditioning temperature and energy consumption related to air conditioning use to provide human thermal comfort,a comparison experiment was conducted in three similar offices at temperatures of 24,26 and 28 ℃ respectively. A thermal comfort questionnaire survey was conducted. It is demonstrated that air-conditioner energy consumption at the set temperature of 28 ℃ is 113% and 271% lower than at 26 ℃ and 24 ℃,respectively. A linear relationship exists between air-conditioner energy consumption and the indoor and outdoor temperature difference. When comfortably dressed,over 80% of research participants accept the set temperature of 28 ℃. The regression analysis leads to a neutral temperature of 26.2 ℃ and an acceptable temperature of 28.2 ℃ for over 80% of the research participants subjects,indicating that the current 26 ℃ set temperature for offices in summer,required by Chinese General Office of the State Council,can be increased to 28 ℃. Moreover,analysis of predicted mean vote(PMV) index shows that a set temperature of 27 ℃,not 26 ℃,is sufficiently comfortable for office staff wearing long-sleeve shirts,long pants and leather shoes.展开更多
In order to make maximum use of the EV (electric vehicle) battery, evaluating the remaining battery capacity and the power consumption is important. Evaluation method of the remaining battery capacity with accuracy ...In order to make maximum use of the EV (electric vehicle) battery, evaluating the remaining battery capacity and the power consumption is important. Evaluation method of the remaining battery capacity with accuracy has been proposed. Moreover, the evaluation method of the power consumption for traveling has been proposed. However, the power consumption for vehicle-mounted air-conditioner is 30%. It is necessary to calculate the power consumption for both traveling and air-conditioning. In this paper, the authors have constructed a mathematical model which calculates the EV power consumption for both traveling and air-conditioning. The calculated results of this model have been compared to actual traveling data. In addition, factors which have a impact on the EV power consumption have been studied. As a result, the EV power consumption is greately varied by slope resistance, acceleration resistance and required air-conditioning load. Moreover, it is clarified that the air-conditioner consumes approximately 25% to 50% of the total power consumption in a hot summer day. In addition, the acceleration and the air-conditioning load differ depending on each vehicle driver. Therefore, in order to evaluate the EV power consumption practically, it is necessary to reflect the characteristics of each vehicle driver.展开更多
Facility management and maintenance of the Thermal-Energy-Storage Air-Conditioning(TES-AC)system is a tedious task at a large scale mainly due to the charging load that can increase energy consumption if needed to be ...Facility management and maintenance of the Thermal-Energy-Storage Air-Conditioning(TES-AC)system is a tedious task at a large scale mainly due to the charging load that can increase energy consumption if needed to be charged at peak hours.Besides,maintenance of TES-AC at a large scale gets complex as it contains many sensor data.By utilizing deep learning techniques on the sensor data,charging load prediction can be made possible,so facility managers can prepare in advance.However,a deep learning-based application will be unusable if it is not deployed in a user-friendly manner where facility managers can benefit from this application.Hence,this research focuses on gathering design guidelines for a deep learning-based application and further validates the design considerations with a developed application for efficient human-computer interaction through qualitative analysis.The approach taken to gather design guidelines demonstrated a positive correlation between expert-suggested features and the user-friendly aspect of the application as 67.08%of participants found the features suggested by experts to be most satisfactory.Furthermore,it evaluates user satisfaction with the advanced developed application for TES-AC according to the gathered design guidelines.展开更多
Suitable control of the humidity can contribute to electric energy savings. However, the present dehumidification system has many weak points. The liquid desiccant air-conditioning system has recently gained growing i...Suitable control of the humidity can contribute to electric energy savings. However, the present dehumidification system has many weak points. The liquid desiccant air-conditioning system has recently gained growing interest from the stand point of reducing energy consumption during dehumidification. In order to find the appropriate ionic liquids(ILs) as a desiccant for the liquid desiccant air-conditioner system, we conducted a systematic evaluation of the humidification capability of 16 types of ILs. Among the tested ILs, tributyl(methyl)phosphonium dimethyl phosphate([P4441][DMPO_4]) exhibited the best dehumidification capacity and had a less corrosive effect on four types of metals as possible piping materials. It should be noted that this [P_(4441)][DMPO_4] has a very stable nature and produced no odor while conducting the experiment and storing for over 1 year at room temperature under ambient conditions. Furthermore, it was revealed that a 77%(w/w) aqueous solution of [P4441][DMPO_4] worked as an efficient desiccant liquid for the liquid desiccant air-conditioner system.展开更多
In this paper, the existence of global attractors for the 2D autonomous g- Navier-Stokes equations on multi-connected bounded domains is investigated under the general assumptions of boundaries. The estimation of the ...In this paper, the existence of global attractors for the 2D autonomous g- Navier-Stokes equations on multi-connected bounded domains is investigated under the general assumptions of boundaries. The estimation of the Hausdorff dimensions for global attractors is given.展开更多
This paper aims to find a more general analysis method for the refrigeration performance,and to design a high efficiency modular cooling structure of water-cooled plate.A new analysis method,namely current and refrige...This paper aims to find a more general analysis method for the refrigeration performance,and to design a high efficiency modular cooling structure of water-cooled plate.A new analysis method,namely current and refrigeration rate density analysis,is proposed.The general refrigeration performance calculation equations are obtained.A finite-time thermodynamic model of the thermoelectric device is established considering Thomson effect.The basic structure of water-cooled thermoelectric air-conditioner is designed and the specific calculation method is given.The influences of input current density,filling factor and heat transfer conditions on refrigeration performance of the thermoelectric air-conditioner are analyzed,which is compared with refrigeration performance of air-cooled thermoelectric air-conditioner.The results show that the maximum refrigeration rate density of the water-cooled thermoelectric air-conditioner is 8.65 k W/m^(2),and the maximum coefficient of performance(COP)is 2.27 in the case of the cooling temperature differenceΔT=5 K.Compared withΔT=5 K,the maximum refrigeration rate density and the maximum COP ofΔT=15 K decreases by 27.98%and 76.65%,respectively.At the filling factorθ=0.43,the refrigeration rate density and COP are 2.57 k W/m~2 and 1.24,respectively.The experimental device of thermoelectric air-conditioner is established to verify the model.The experimental results show that the maximum value of input current and COP is 4 A and 0.95 with the efficient water-cooling method,respectively.The experimental data coincides with the theoretical calculation,which shows the validity of the analysis method and cooling method.展开更多
Nowadays,the most notable uncertainty for an electricity utility lies in the electrical demand of end-users.Demand response(DR)has acquired considerable attention due to uncertain generation outputs from intermittent ...Nowadays,the most notable uncertainty for an electricity utility lies in the electrical demand of end-users.Demand response(DR)has acquired considerable attention due to uncertain generation outputs from intermittent renewable energy sources and advancements of smart grid technologies.The percentage of the air-conditioner(AC)load over the total load demand in a building is usually very high.Therefore,controlling the power demand of ACs is one of significant measures for implementing DR.In this paper,the increasing development of ACs,and their impacts on power demand are firstly introduced,with an overview of possible DR programs.Then,a comprehensive review and discussion on control techniques and DR programs for ACs to manage electricity utilization in residential and commercial energy sectors are carried out.Next,comparative analysis among various programs and projects utilized in different countries for optimizing electricity consumption by ACs is presented.Finally,the conclusions along with future recommendations and challenges for optimal employment of ACs are presented in the perspective of power systems.展开更多
The controlling algorithm was studied for the inverter-driven multi-type air conditioner using electronic expansion valve(EEV) in outdoor unit. The performance of inverter-driven air conditioner with two different uni...The controlling algorithm was studied for the inverter-driven multi-type air conditioner using electronic expansion valve(EEV) in outdoor unit. The performance of inverter-driven air conditioner with two different units was investigated by varying the outdoor ambient temperature and compressor speed. Based on the test results, the effect of EEV opening on the indoor unit exit superheat was discussed. For the specified outdoor ambient temperature scope and the EEV opening, the superheats of indoor units decrease with the outdoor ambient temperature rising. Improper distribution of refrigerant into each indoor unit will causes excessive superheat difference between two indoor units. Suggestions were then given for the controlling of the superheat.展开更多
On the bafis of the generalized von K(?)rm(?)n theory for perforated thin plates established in [1,2], the existence of buckled states for perforated plates subjected to self-equilibrating inplane forces along each ed...On the bafis of the generalized von K(?)rm(?)n theory for perforated thin plates established in [1,2], the existence of buckled states for perforated plates subjected to self-equilibrating inplane forces along each edge systematically is investigated. This work completely generalizes the results in [3, 4].展开更多
The trace of the wave kernel μ(t) =∑ω=1^∞ exp(-itEω^1/2), where {Eω}ω^∞=1 are the eigenvalues of the negative Laplacian -△↓2 = -∑k^3=1 (δ/δxk)^2 in the (x^1, x^2, x^3)-space, is studied for a vari...The trace of the wave kernel μ(t) =∑ω=1^∞ exp(-itEω^1/2), where {Eω}ω^∞=1 are the eigenvalues of the negative Laplacian -△↓2 = -∑k^3=1 (δ/δxk)^2 in the (x^1, x^2, x^3)-space, is studied for a variety of bounded domains, where -∞ 〈 t 〈 ∞ and i= √-1. The dependence of μ (t) on the connectivity of bounded domains and the Dirichlet, Neumann and Robin boundary conditions are analyzed. Particular attention is given for a multi-connected vibrating membrane Ω in Ra surrounded by simply connected bounded domains Ω j with smooth bounding surfaces S j (j = 1,……, n), where a finite number of piecewise smooth Dirichlet, Neumann and Robin boundary conditions on the piecewise smooth components Si^* (i = 1 + kj-1,……, kj) of the bounding surfaces S j are considered, such that S j = Ui-1+kj-1^kj Si^*, where k0=0. The basic problem is to extract information on the geometry Ω by using the wave equation approach from a complete knowledge of its eigenvalues. Some geometrical quantities of Ω (e.g. the volume, the surface area, the mean curvuture and the Gaussian curvature) are determined from the asymptotic expansion ofexpansion of μ(t) for small │t│.展开更多
基金supported in part by the National Natural Science Foundation of China(grant nos.61971365,61871339,62171392)Digital Fujian Province Key Laboratory of IoT Communication,Architecture and Safety Technology(grant no.2010499)+1 种基金the State Key Program of the National Natural Science Foundation of China(grant no.61731012)the Natural Science Foundation of Fujian Province of China No.2021J01004.
文摘Unmanned Aerial Vehicles(UAvs)as aerial base stations to provide communication services for ground users is a flexible and cost-effective paradigm in B5G.Besides,dynamic resource allocation and multi-connectivity can be adopted to further harness the potentials of UAVs in improving communication capacity,in such situations such that the interference among users becomes a pivotal disincentive requiring effective solutions.To this end,we investigate the Joint UAV-User Association,Channel Allocation,and transmission Power Control(J-UACAPC)problem in a multi-connectivity-enabled UAV network with constrained backhaul links,where each UAV can determine the reusable channels and transmission power to serve the selected ground users.The goal was to mitigate co-channel interference while maximizing long-term system utility.The problem was modeled as a cooperative stochastic game with hybrid discrete-continuous action space.A Multi-Agent Hybrid Deep Reinforcement Learning(MAHDRL)algorithm was proposed to address this problem.Extensive simulation results demonstrated the effectiveness of the proposed algorithm and showed that it has a higher system utility than the baseline methods.
基金Supported by Program for Changjiang Scholars and Innovative Research Team in University,Ministry of Education of China(PCSIRT)
文摘DC-inverter split air-conditioner is widely used in Chinese homes as a result of its high-efficiency and energy-saving. Recently, the researches on its outdoor unit have focused on the influence of surrounding structures upon the aerodynamic and acoustic performance, however they are only limited to the influence of a few parameters on the performance, and practical design of the unit requires more detailed parametric analysis. Three-dimensional computational fluid dynamics(CFD) and computational aerodynamic acoustics(CAA) simulation based on FLUENT solver is used to study the influence of surrounding structures upon the aforementioned properties of the unit. The flow rate and sound pressure level are predicted for different rotating speed, and agree well with the experimental results. The parametric influence of three main surrounding structures(i.e. the heat sink, the bell-mouth type shroud and the outlet grille) upon the aerodynamic performance of the unit is analyzed thoroughly. The results demonstrate that the tip vortex plays a major role in the flow fields near the blade tip and has a great effect on the flow field of the unit. The inlet ring's size and throat's depth of the bell-mouth type shroud, and the through-flow area and configuration of upwind and downwind sections of the outlet grille are the most important factors that affect the aerodynamic performance of the unit. Furthermore, two improved schemes against the existing prototype of the unit are developed, which both can significantly increase the flow rate more than 6 %(i.e. 100 m3·h~(-1)) at given rotating speeds. The inevitable increase of flow noise level when flow rate is increased and the advantage of keeping a lower rotating speed are also discussed. The presented work could be a useful guideline in designing the aerodynamic and acoustic performance of the split air-conditioner in engineering practice.
基金This work was supported by the NSF (19971061) of China and the Science Foundation ofFushun Petroleum Institute.
文摘In this paper, we investigate the Toeplitz operators with positive measure symbols on the Bergman spaces of bounded multi-connected domains and show that a Toeplitz operator is bounded or compact if and only if the symbol measure is a Carleson or vanishing Carleson measure respectively.
文摘China is the largest producer and consumer of hydrochlorofluorocarbons (HCFCs), and the production of HCFC-22 accounts for more than 80% of all HCFCs. This paper concentrates on the residential air-conditioner industry and analyzes the environmental benefits of accelerating the phase-out of HCFC-22 in China. According to the comparison of the baseline and phase-out scenarios of HCFC-22, the findings show that using HC-290 (propane) as a refrigerant alternative will directly reduce the greenhouse effect, and indirectly reduce the emission of greenhouse gases due to a reduction in the electricity consumption. The comparison of two scenarios of HC-290 and HFC-410A refrigerant alternatives shows that the use of HC-290 refrigerant will produce significantly higher environmental benefits than the HFC-410A refrigerant.
文摘HFC-134a is the most important alternative to CFC-12 used in the mobile air-conditioner sector in China. The con- sumption of HFC-134a has been increasing rapidly in recent years. It becomes the most consumed HFC in the sector. Selecting 2005 as the base line year, future consumption and emission amounts of HFC-134a are estimated through an analysis of a combined scenario: 1) replacement by non-HFC-134a blends, 2) good practice in servicing, 3) technology promotion, and 4) government policies on control of HFC-134a emissions. The analysis shows that HFC-134a consumption and emissions will continue to increase in the next 10 years. The projected HFC-134a consumption will approach 20,150 t and 34,875 t in 2010 and 2015 respectively, while the estimated emission amounts will reach 16,065 t and 30,186 t (i.e., 21 Mt CO2-eq and 39 Mt CO2-eq emissions) correspondingly. Compared with the business-as-usual scenario, the expected emission reductions in 2010 and 2015 will range between 6.7 Mt CO2-eq and 13.0 Mt CO2-eq.
文摘This paper studies the influence of a finite container on an ideal gas.The trace of the heat kernel (t) =exp, where are the eigenvalues of the negative Laplacian -in Rn(n = 2 or 3), is studied for a general multi-connected bounded drum ft which is surrounded by simply connected bounded domains Ωi with smooth boundaries Ωi(i = 1,… ,m) where the Dirichlet, Neumann and Robin boundary conditions on Ωi(i = 1,…,m) are considered. Some geometrical properties of Ω are determined. The thermodynamic quantities for an ideal gas enclosed in Ω are examined by using the asymptotic expansions of (t) for short-time t. It is shown that the ideal gas can not feel the shape of its container Ω, although it can feel some geometrical properties of it.
文摘In order to expand the natural energy and the energy conservation, "the smart PV (photovoltaic power generation) & EV (electric vehicle) system" has been proposed and the effect has been clarified. In the smart PV & EV system, it is important that electric vehicles become popular. Therefore, the AI-EV (air-conditioner integrated electric vehicle) has been proposed. In this paper, the AI-EV is designed based on the required car air-conditioner capacity. And, the value of AI-EV is compared with a gasoline vehicle, HV (hybrid vehicle) and EV using the mathematical simulation model As a result, it is clarified that the minimum displacement of the small-engine is 120 cc for AI-EV. In the smart PV & EV system, AI-EV can reduce CO_2 emissions by 20% almost the same as EV. Additionally, AI-EV is able to gain the cruising range more than twice as long as EV.
文摘Aim: To investigate the effect of air-conditioner exposure on semen quality. Methods: The data came from the healthy male volunteers, aged 22 to 30 years, who went to centers for maternity and children health for premarital physical examination in Shanghai, Henan, Zhejiang and Hebei from December 1998 to February 2000. The sampling size is 304. Results: Among the subjects, 90 (29.6 %) had air-conditioner at home and the rest did not. X2-test and multiple logistic regression analyses showed that, the difference between the exposure and control groups was statistically significant in semen volume, sperm density and proportion of sperm with normal morphology. The three indexes were lower in the exposure group. Conclusion: Air-conditioner exposure possibly influences the semen quality.
基金supported by NSFC project(grant No.61971359)Chongqing Municipal Key Laboratory of Institutions of Higher Education(grant No.cquptmct-202104)+1 种基金Fundamental Research Funds for the Central Universities,Sichuan Science and Technology Project(grant no.2021YFQ0053)State Key Laboratory of Rail Transit Engineering Informatization(FSDI).
文摘The increasing demand for industrial automation and intelligence has put forward higher requirements for the reliability of industrial wireless communication technology.As an international standard based on 802.11,Wireless networks for Industrial Automation-Factory Automation(WIA-FA)greatly improves the reliability in factory automation scenarios by Time Division Multiple Access(TDMA).However,in ultra-dense WIA-FA networks with mobile users,the basic connection management mechanism is inefficient.Most of the handover and resource management algorithms are all based on frequency division multiplexing,not suitable for the TDMA in the WIA-FA network.Therefore,we propose Load-aware Connection Management(LACM)algorithm to adjust the linkage and balance the load of access devices to avoid blocking and improve the reliability of the system.And then we simulate the algorithm to find the optimal settings of the parameters.After comparing with other existing algorithms,the result of the simulation proves that LACM is more efficient in reliability and maintains high reliability of more than 99.8%even in the ultra-dense moving scenario with 1500 field devices.Besides,this algorithm ensures that only a few signaling exchanges are required to ensure load bal-ancing,which is no more than 5 times,and less than half of the best state-of-the-art algorithm.
基金Project(50838009) supported by the National Natural Science Foundation of ChinaProjects(2006BAJ02A09,2006BAJ02A13-4) supported by the National Key Technologies R & D Program of China
文摘To explore the relationship between summer office set air-conditioning temperature and energy consumption related to air conditioning use to provide human thermal comfort,a comparison experiment was conducted in three similar offices at temperatures of 24,26 and 28 ℃ respectively. A thermal comfort questionnaire survey was conducted. It is demonstrated that air-conditioner energy consumption at the set temperature of 28 ℃ is 113% and 271% lower than at 26 ℃ and 24 ℃,respectively. A linear relationship exists between air-conditioner energy consumption and the indoor and outdoor temperature difference. When comfortably dressed,over 80% of research participants accept the set temperature of 28 ℃. The regression analysis leads to a neutral temperature of 26.2 ℃ and an acceptable temperature of 28.2 ℃ for over 80% of the research participants subjects,indicating that the current 26 ℃ set temperature for offices in summer,required by Chinese General Office of the State Council,can be increased to 28 ℃. Moreover,analysis of predicted mean vote(PMV) index shows that a set temperature of 27 ℃,not 26 ℃,is sufficiently comfortable for office staff wearing long-sleeve shirts,long pants and leather shoes.
文摘In order to make maximum use of the EV (electric vehicle) battery, evaluating the remaining battery capacity and the power consumption is important. Evaluation method of the remaining battery capacity with accuracy has been proposed. Moreover, the evaluation method of the power consumption for traveling has been proposed. However, the power consumption for vehicle-mounted air-conditioner is 30%. It is necessary to calculate the power consumption for both traveling and air-conditioning. In this paper, the authors have constructed a mathematical model which calculates the EV power consumption for both traveling and air-conditioning. The calculated results of this model have been compared to actual traveling data. In addition, factors which have a impact on the EV power consumption have been studied. As a result, the EV power consumption is greately varied by slope resistance, acceleration resistance and required air-conditioning load. Moreover, it is clarified that the air-conditioner consumes approximately 25% to 50% of the total power consumption in a hot summer day. In addition, the acceleration and the air-conditioning load differ depending on each vehicle driver. Therefore, in order to evaluate the EV power consumption practically, it is necessary to reflect the characteristics of each vehicle driver.
文摘Facility management and maintenance of the Thermal-Energy-Storage Air-Conditioning(TES-AC)system is a tedious task at a large scale mainly due to the charging load that can increase energy consumption if needed to be charged at peak hours.Besides,maintenance of TES-AC at a large scale gets complex as it contains many sensor data.By utilizing deep learning techniques on the sensor data,charging load prediction can be made possible,so facility managers can prepare in advance.However,a deep learning-based application will be unusable if it is not deployed in a user-friendly manner where facility managers can benefit from this application.Hence,this research focuses on gathering design guidelines for a deep learning-based application and further validates the design considerations with a developed application for efficient human-computer interaction through qualitative analysis.The approach taken to gather design guidelines demonstrated a positive correlation between expert-suggested features and the user-friendly aspect of the application as 67.08%of participants found the features suggested by experts to be most satisfactory.Furthermore,it evaluates user satisfaction with the advanced developed application for TES-AC according to the gathered design guidelines.
基金supported by a fund for environmental research from Tottori University
文摘Suitable control of the humidity can contribute to electric energy savings. However, the present dehumidification system has many weak points. The liquid desiccant air-conditioning system has recently gained growing interest from the stand point of reducing energy consumption during dehumidification. In order to find the appropriate ionic liquids(ILs) as a desiccant for the liquid desiccant air-conditioner system, we conducted a systematic evaluation of the humidification capability of 16 types of ILs. Among the tested ILs, tributyl(methyl)phosphonium dimethyl phosphate([P4441][DMPO_4]) exhibited the best dehumidification capacity and had a less corrosive effect on four types of metals as possible piping materials. It should be noted that this [P_(4441)][DMPO_4] has a very stable nature and produced no odor while conducting the experiment and storing for over 1 year at room temperature under ambient conditions. Furthermore, it was revealed that a 77%(w/w) aqueous solution of [P4441][DMPO_4] worked as an efficient desiccant liquid for the liquid desiccant air-conditioner system.
基金Project supported by the National Natural Science Fundation of China (No. 11171269)the Natural Science Basic Research Plan in Shaanxi Province of China (No. 2012JM1012)the Scientific Research Program Funded by Shaanxi Provincial Education Department (No. 12JK0849)
文摘In this paper, the existence of global attractors for the 2D autonomous g- Navier-Stokes equations on multi-connected bounded domains is investigated under the general assumptions of boundaries. The estimation of the Hausdorff dimensions for global attractors is given.
基金supported by The National Natural Science Foundation of P.R.China(Project No.11974429 and Project No.51576207)the Natural Science Foundation of Naval University of Engineering(20161505)。
文摘This paper aims to find a more general analysis method for the refrigeration performance,and to design a high efficiency modular cooling structure of water-cooled plate.A new analysis method,namely current and refrigeration rate density analysis,is proposed.The general refrigeration performance calculation equations are obtained.A finite-time thermodynamic model of the thermoelectric device is established considering Thomson effect.The basic structure of water-cooled thermoelectric air-conditioner is designed and the specific calculation method is given.The influences of input current density,filling factor and heat transfer conditions on refrigeration performance of the thermoelectric air-conditioner are analyzed,which is compared with refrigeration performance of air-cooled thermoelectric air-conditioner.The results show that the maximum refrigeration rate density of the water-cooled thermoelectric air-conditioner is 8.65 k W/m^(2),and the maximum coefficient of performance(COP)is 2.27 in the case of the cooling temperature differenceΔT=5 K.Compared withΔT=5 K,the maximum refrigeration rate density and the maximum COP ofΔT=15 K decreases by 27.98%and 76.65%,respectively.At the filling factorθ=0.43,the refrigeration rate density and COP are 2.57 k W/m~2 and 1.24,respectively.The experimental device of thermoelectric air-conditioner is established to verify the model.The experimental results show that the maximum value of input current and COP is 4 A and 0.95 with the efficient water-cooling method,respectively.The experimental data coincides with the theoretical calculation,which shows the validity of the analysis method and cooling method.
基金jointly supported by National Key R&D Program of China(No.2016YFB0900100)National Natural Science Foundation of China(No.51777185)Natural Science Foundation of Zhejiang Province(No.LY17E070003)。
文摘Nowadays,the most notable uncertainty for an electricity utility lies in the electrical demand of end-users.Demand response(DR)has acquired considerable attention due to uncertain generation outputs from intermittent renewable energy sources and advancements of smart grid technologies.The percentage of the air-conditioner(AC)load over the total load demand in a building is usually very high.Therefore,controlling the power demand of ACs is one of significant measures for implementing DR.In this paper,the increasing development of ACs,and their impacts on power demand are firstly introduced,with an overview of possible DR programs.Then,a comprehensive review and discussion on control techniques and DR programs for ACs to manage electricity utilization in residential and commercial energy sectors are carried out.Next,comparative analysis among various programs and projects utilized in different countries for optimizing electricity consumption by ACs is presented.Finally,the conclusions along with future recommendations and challenges for optimal employment of ACs are presented in the perspective of power systems.
文摘The controlling algorithm was studied for the inverter-driven multi-type air conditioner using electronic expansion valve(EEV) in outdoor unit. The performance of inverter-driven air conditioner with two different units was investigated by varying the outdoor ambient temperature and compressor speed. Based on the test results, the effect of EEV opening on the indoor unit exit superheat was discussed. For the specified outdoor ambient temperature scope and the EEV opening, the superheats of indoor units decrease with the outdoor ambient temperature rising. Improper distribution of refrigerant into each indoor unit will causes excessive superheat difference between two indoor units. Suggestions were then given for the controlling of the superheat.
基金State Education Commission of the People's Republic of China
文摘On the bafis of the generalized von K(?)rm(?)n theory for perforated thin plates established in [1,2], the existence of buckled states for perforated plates subjected to self-equilibrating inplane forces along each edge systematically is investigated. This work completely generalizes the results in [3, 4].
文摘The trace of the wave kernel μ(t) =∑ω=1^∞ exp(-itEω^1/2), where {Eω}ω^∞=1 are the eigenvalues of the negative Laplacian -△↓2 = -∑k^3=1 (δ/δxk)^2 in the (x^1, x^2, x^3)-space, is studied for a variety of bounded domains, where -∞ 〈 t 〈 ∞ and i= √-1. The dependence of μ (t) on the connectivity of bounded domains and the Dirichlet, Neumann and Robin boundary conditions are analyzed. Particular attention is given for a multi-connected vibrating membrane Ω in Ra surrounded by simply connected bounded domains Ω j with smooth bounding surfaces S j (j = 1,……, n), where a finite number of piecewise smooth Dirichlet, Neumann and Robin boundary conditions on the piecewise smooth components Si^* (i = 1 + kj-1,……, kj) of the bounding surfaces S j are considered, such that S j = Ui-1+kj-1^kj Si^*, where k0=0. The basic problem is to extract information on the geometry Ω by using the wave equation approach from a complete knowledge of its eigenvalues. Some geometrical quantities of Ω (e.g. the volume, the surface area, the mean curvuture and the Gaussian curvature) are determined from the asymptotic expansion ofexpansion of μ(t) for small │t│.