期刊文献+
共找到4,074篇文章
< 1 2 204 >
每页显示 20 50 100
Double contrast-enhanced ultrasonography improves diagnostic accuracy of T staging compared with multi-detector computed tomography in gastric cancer patients
1
作者 Yan-Fen Xu Hui-Yun Ma +4 位作者 Gui-Ling Huang Yu-Ting Zhang Xue-Yan Wang Ming-Jie Wei Xiao-Qing Pei 《World Journal of Gastroenterology》 SCIE CAS 2024年第23期3005-3015,共11页
BACKGROUND Gastric cancer(GC)is the most common malignant tumor and ranks third for cancer-related deaths among the worldwide.The disease poses a serious public health problem in China,ranking fifth for incidence and ... BACKGROUND Gastric cancer(GC)is the most common malignant tumor and ranks third for cancer-related deaths among the worldwide.The disease poses a serious public health problem in China,ranking fifth for incidence and third for mortality.Knowledge of the invasive depth of the tumor is vital to treatment decisions.AIM To evaluate the diagnostic performance of double contrast-enhanced ultrasonography(DCEUS)for preoperative T staging in patients with GC by comparing with multi-detector computed tomography(MDCT).METHODS This single prospective study enrolled patients with GC confirmed by preoperative gastroscopy from July 2021 to March 2023.Patients underwent DCEUS,including ultrasonography(US)and intravenous contrast-enhanced ultrasonography(CEUS),and MDCT examinations for the assessment of preoperative T staging.Features of GC were identified on DCEUS and criteria developed to evaluate T staging according to the 8th edition of AJCC cancer staging manual.The diagnostic performance of DCEUS was evaluated by comparing it with that of MDCT and surgical-pathological findings were considered as the gold standard.RESULTS A total of 229 patients with GC(80 T1,33 T2,59 T3 and 57 T4)were included.Overall accuracies were 86.9%for DCEUS and 61.1%for MDCT(P<0.001).DCEUS was superior to MDCT for T1(92.5%vs 70.0%,P<0.001),T2(72.7%vs 51.5%,P=0.041),T3(86.4%vs 45.8%,P<0.001)and T4(87.7%vs 70.2%,P=0.022)staging of GC.CONCLUSION DCEUS improved the diagnostic accuracy of preoperative T staging in patients with GC compared with MDCT,and constitutes a promising imaging modality for preoperative evaluation of GC to aid individualized treatment decision-making. 展开更多
关键词 Double contrast-enhanced ultrasonography multi-detector computed tomography Gastric cancer T staging
下载PDF
Efficacy of multi-slice spiral computed tomography in evaluating gastric cancer recurrence after endoscopic submucosal dissection 被引量:2
2
作者 Jian-Jun Yin Xiao Hu +1 位作者 Sen Hu Guo-Hong Sheng 《World Journal of Gastrointestinal Oncology》 SCIE 2023年第9期1636-1643,共8页
BACKGROUND Recurrence is the major challenge facing endoscopic submucosal dissection(ESD)-based treatment therapies for early gastric cancer(EGC).Urgent development of simple and easy surveillance approaches will enha... BACKGROUND Recurrence is the major challenge facing endoscopic submucosal dissection(ESD)-based treatment therapies for early gastric cancer(EGC).Urgent development of simple and easy surveillance approaches will enhance clinical treatment of the disease.AIM To explore the role of computed tomography(CT)recurrence in evaluating EGC after ESD treatment.METHODS We retrospectively recruited patients from our endoscopy department,between January 2002 and December 2015,and analyzed their basic characteristics,including symptoms,CT results,and results of endoscopy with biopsy,among others.RESULTS Among a total of 2150 patients EGC patients surveyed,1362 met our inclusion and exclusion criteria and were therefore enrolled in our study.The cohort’s sensitivity of CT for recurrent GC and specificity were 44.22%and 43.86%,respectively,with negative and positive predictive values of 40.15%(275/685)and 48.01%(325/677),respectively.The area under the curve of arterial and venous CT values for recurrent EGC were 0.545,and 0.604,respectively.Receiver operating characteristic curve revealed no statistically significant differences between arterial and venous CT values for recurrent EGC.CONCLUSION Enhanced CT has superior diagnostic efficacy,but less accuracy,compared to gold standard techniques in patients with recurrent EGC. 展开更多
关键词 Computed tomography Early gastric cancer Gastric cancer Multi-slice spiral computed tomography
下载PDF
Diagnostic ability of multi-detector spiral computed tomography for pathological lymph node metastasis of advanced gastric cancer 被引量:5
3
作者 Zhi-Yong Jiang Shinichi Kinami +5 位作者 Naohiko Nakamura Takashi Miyata Hideto Fujita Hiroyuki Takamura Nobuhiko Ueda Takeo Kosaka 《World Journal of Gastrointestinal Oncology》 SCIE CAS 2020年第4期435-446,共12页
BACKGROUND The reliability of preoperative nodal diagnosis of advanced gastric cancer by multi-detector spiral computed tomography(MDCT)is still unclear.AIM To examine the diagnostic ability of MDCT more precisely by ... BACKGROUND The reliability of preoperative nodal diagnosis of advanced gastric cancer by multi-detector spiral computed tomography(MDCT)is still unclear.AIM To examine the diagnostic ability of MDCT more precisely by using data on intranodal pathological metastatic patterns.METHODS A total of 108 patients with advanced gastric cancer who underwent MDCT and curative gastrectomy at Kanazawa Medical University Hospital were enrolled in this study.The nodal sizes measured on computed tomography(CT)images were compared with the pathology results.A receiver-operating characteristic curve was constructed,from which the critical value(CV)was calculated by using the data of the first 69 patients retrospectively.By using the CV,sensitivity and specificity were calculated with prospectively collected data from 39 consecutive patients.This enabled a more precise one-to-one correspondence of lymph nodes between CT and pathological examination by using the size data of lymph node mapping.The intranodal pathological metastatic patterns were classified into the following four types:Small nodular,peripheral,large nodular,and diffuse.RESULTS Although all the cases were clinically suspected as having metastasis,81 had lymph node metastasis and 27 had no metastasis.The number of dissected,detected on CT,and metastatic nodes were,4241,897,and 801,respectively.The CV obtained from the receiver-operating characteristic was 7.6 mm for the long axis.The sensitivity was 91.4%and the specificity was 47.3%in the prospective phase.The large nodular and diffuse metastases were easy to diagnose becausemetastatic nodes with a large axis often exhibit these forms.CONCLUSION The ability of MDCT to contribute to a nodal diagnosis of advanced gastric cancer was examined prospectively with precise size data from node mapping,using a CV of 7.6 mm for the long axis that was calculated from the retrospectively collected data.The sensitivity was as high as 91%,and would be improved when referring to the enhanced patterns.However,its specificity was as low as 47%,because most of metastatic nodes in gastric cancer being small in size.The small nodular or peripheral type metastatic nodes were often small and considered difficult to diagnose. 展开更多
关键词 Advanced GASTRIC cancer LYMPH node METASTASIS multi-detector spiral COMPUTED tomography PATHOLOGICAL diagnosis
下载PDF
Coronary Artery Anomalies Detected by Multi-Detector Computed Tomography: A Single Centre Experience
4
作者 Basma Hammad Eman El-sharkawy +6 位作者 Yasser Morsi Noha Shabaan Salah Eltahan Mohamed Elshafi Shady Abohashem Tanveer Mir Mostafa Elwany 《World Journal of Cardiovascular Diseases》 2023年第6期261-274,共14页
Background: Coronary artery anomalies (CAA) prevalence represents less than 1% of congenital heart diseases. It includes anomalies in origin, course, and termination. Its detection has been easier with advances i... Background: Coronary artery anomalies (CAA) prevalence represents less than 1% of congenital heart diseases. It includes anomalies in origin, course, and termination. Its detection has been easier with advances in imaging techniques using multi-detector computed tomography (MDCT). MDCT helps not only detection of the anomalous origin, but it allows delineation of the course and termination of the arteries, differentiation between benign and malignant courses, and guiding therapeutic interventions. Results: There were consecutive patients with a low-to-intermediate probability of coronary artery disease scanned with 128 MDCT. Each patient underwent a non-contrast prospective gating acquisition for coronary calcium scoring followed by contrast-enhanced helical retrospective gated scans for the detection of coronary artery origin, course, termination, and detection of concomitant atherosclerosis. We scanned 1000 patients with a mean age of 57.5 ± 8.3, and 68% were males. Thirty-two anomalies were noted (3.2%) including;nineteen (1.9%) anomalous origin from the opposite sinus, three (0.3%) anomalous left coronary arteries from the pulmonary artery (ALCAPA), one (0.1%) super dominant left anterior descending artery (LAD) giving origin to the posterior descending artery (PDA), three single coronary arteries (0.3%)in which the left main (LM) and right coronary arteries were originating with a common stem from the right coronary sinus (RCS)and the LM took a pre-pulmonic course. Along with six (0.6%) dual LAD including five (0.5%) patients with type I (short LAD and long diagonal), there was one (0.1%) type 4 with an extra LAD originating from the RCS with a pre-pulmonic course. Conclusions: MDCT allows easy detection of coronary anomalies with high spatial resolution and overcomes limitations in conventional invasive coronary angiography. Based on our study we recommend the use of MDCT as an efficient and feasible modality for the diagnosis of coronary anomalies once this pathology is clinically suspected. 展开更多
关键词 Coronary Artery Anomalies Spatial Resolution multi-detector Computed tomography
下载PDF
Multi-slice spiral computed tomography in differential diagnosis of gastric stromal tumors and benign gastric polyps,and gastric stromal tumor risk stratification assessment 被引量:4
5
作者 Xiao-Long Li Peng-Fei Han +2 位作者 Wei Wang Li-Wei Shao Ying-Wei Wang 《World Journal of Gastrointestinal Oncology》 SCIE 2022年第10期2004-2013,共10页
BACKGROUND The biological characteristics of gastric stromal tumors are complex,and their incidence has increased in recent years.Gastric stromal tumors(GST)have potential malignant tendencies,and the probability of t... BACKGROUND The biological characteristics of gastric stromal tumors are complex,and their incidence has increased in recent years.Gastric stromal tumors(GST)have potential malignant tendencies,and the probability of transformation into malignant tumors is as high as 20%-30%.AIM To investigate the value of multi-slice spiral computed tomography(MSCT)in the differential diagnosis of GST and benign gastric polyps,and GST risk stratification assessment.METHODS We included 64 patients with GST(GST group)and 60 with benign gastric polyps(control group),confirmed by pathological examination after surgery in PLA General Hospital,from January 2016 to June 2021.The differences in the MSCT imaging characteristic parameters and enhanced CT values between the two groups before surgery were compared.According to the National Institutes of Health’s standard,GST is divided into low-and high-risk groups for MSCT imaging characteristic parameters and enhanced CT values.RESULTS The incidences of extraluminal growth,blurred boundaries,and ulceration in the GST group were significantly higher than those in the control group(P<0.05).The CT values and enhanced peak CT values in the arterial phase in the CST group were higher than those in the control group(P<0.05).The MSCT differential diagnosis of GST and gastric polyp sensitivity,specificity,misdiagnosis rate,missed diagnosis rate,and areas under the curve(AUCs)were 73.44%,83.33%,26.56%,16.67%,0.784,respectively.The receiver operating characteristic curves were plotted with the arterial CT value and enhanced peak CT value,with a statistical difference.The results showed that the sensitivity,specificity,misdiagnosis rate,missed diagnosis rate,and AUC value of arterial CT in the differential diagnosis of GST and gastric polyps were 80.18%,62.20%,19.82%,37.80%,and 0.710,respectively.The sensitivity,specificity,misdiagnosis rate,missed diagnosis rate,and AUC value of the enhanced peak CT value in the differential diagnosis of GST and gastric polyps were 67.63%,60.40%,32.37%,39.60%,and 0.710,respectively.The incidence of blurred lesion boundaries and ulceration in the high-risk group was significantly higher than that in the low-risk group(P<0.05).The arterial phase and enhanced peak CT values in the high-risk group were significantly higher than those in the low-risk group(P<0.05).CONCLUSION Presurgical MSCT examination has important value in the differential diagnosis of GST and gastric benign polyps and can effectively evaluate the risk grade of GST patients. 展开更多
关键词 Multi-slice spiral computed tomography Differential diagnosis Gastric stromal tumor Benign gastric polyps Risk stratification
下载PDF
Multi-slice spiral computed tomography in diagnosing unstable pelvic fractures in elderly and effect of less invasive stabilization 被引量:4
6
作者 Jian-Guo Huang Zhi-Yuan Zhang +2 位作者 Liang Li Guang-Bao Liu Xiong Li 《World Journal of Clinical Cases》 SCIE 2022年第14期4470-4479,共10页
BACKGROUND Older people are more likely to experience pelvic fractures than younger people.Multi-slice spiral computed tomography(CT)uses three-dimensional(3D)reconstruction technology to generate 3D images that can c... BACKGROUND Older people are more likely to experience pelvic fractures than younger people.Multi-slice spiral computed tomography(CT)uses three-dimensional(3D)reconstruction technology to generate 3D images that can clearly demonstrate the 3D space of fractures and detect fractures at a higher rate.AIM To investigate the clinical value of multi-slice spiral CT 3D reconstruction in the diagnosis of unstable pelvic fractures in the elderly as well as the effect of less invasive stabilization.METHODS A total of 86 patients with unstable pelvic fractures treated between March 2016 and March 2019 underwent femoral supracondylar bone traction before surgery.Pelvic radiography and multi-row spiral CT were performed successively once the patient’s vital signs and hemodynamic indices were stable.Secondary processing of the original data was performed to obtain 3D reconstruction images and determine the vertical displacement of the pelvis.After basic or complete reduction,minimally invasive internal fixation using hollow lag screws was performed.The detection rates of fracture location and classification by X-ray and CT reconstruction were compared.Patients were divided into two groups according to the presence or absence of preoperative 3D reconstruction to compare postoperative reduction,wound healing time,fracture healing time,hospitalization time,visual analog scale(VAS)score,poor internal fixation,and functional recovery.RESULTS The diagnostic coincidence rates of X-rays for pubic symphysis,ilium wing,sacroiliac periarticular,and sacral fractures were lower than those of CT reconstruction.The coincidence rate of CT reconstruction in the clinical classification of pelvic fractures was 100%,whereas 11 cases were misdiagnosed by X-ray;the total coincidence rate was 87.21%.The total excellent and good rates of postoperative reduction were significantly higher in the study group than in the control group(P<0.05).The wound healing,fracture healing,and hospitalization times were significantly shorter in the study group than in the control group(P<0.05).The VAS scores decreased in both groups postoperatively and were lower in the study group than in the control group(P<0.05).The total incidence of poor postoperative internal fixation was significantly lower in the study group than in the control group(P<0.05).The overall rate of postoperative functional recovery was significantly higher in the study group than in the control group(P<0.05).CONCLUSION Multi-slice spiral CT has high guiding significance for the diagnosis,classification,and treatment of unstable pelvic fractures in the elderly.Preoperative 3D reconstruction can effectively shorten the operation time and promote fracture healing,while minimally invasive internal fixation can effectively reduce pain and promote functional recovery of fracture sites,making it worthy of clinical application. 展开更多
关键词 Multi-slice spiral computed tomography Three-dimensional reconstruction Unstable pelvic fracture Minimally invasive internal fixation Diagnostic value
下载PDF
Diagnosis of Congenital Aortic Arch Anomalies in Chinese Children by Multi-Detector Computed Tomography Angiography 被引量:2
7
作者 陈鑫 屈艳娟 +2 位作者 彭志远 鲁锦国 马小静 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2013年第3期447-451,共5页
Summary: The purpose of this study was to evaluate the value of multi-detector computed tomography (MDCT) angiography for the diagnosis of congenital aortic arch anomalies and present the radiological images of con... Summary: The purpose of this study was to evaluate the value of multi-detector computed tomography (MDCT) angiography for the diagnosis of congenital aortic arch anomalies and present the radiological images of congenital aortic arch anomalies in Chinese children. MDCT angiography and transthoracic echocardiography (TTE) were applied for the diagnosis of congenital aortic arch anomalies in 362 Chi- nese children between May 2006 and December 2011 (age ranges from 5 days to 12 years; mean age, 3.3 years). Surgery and/or catheter angiography (CA) were conducted in all patients to confirm the final diagnosis. In the 362 Chinese children with congenital heart anomalies, congenital aortic arch anomalies were definitely diagnosed in 198 children and 164 children ruled out by operation and/or (CA). Among the 198 children with anomalies, coarctation of aorta (CoA), interruption of aortic arch (IAA), fight aor- tic arch, aberrant right subclavian artery and double aortic arch were diagnosed in 134, 32, 20, 10 and 2 children respectively, and there were 6 cases with uncommon congenital aortic arch anomalies: 2 had double aortic arch including 1 with five branches of the aortic arch, 2 had isolation of the right sub- clavian artery with two patent ductus arteriosus (PDA), 1 had an isolation of the common carotid artery with a PDA, and 1 had double PDA with a single ventricle and pulmonary artery atresia. Among the 32 children with IAA, 28 were of type A, and 4 were of type B. The diagnostic sensitivity, specificity and accuracy of MDCT angiography for congenital aortic arch anomaiies were 100% (198/198), 98% (161/164) and 99% (359/362), respectively. The diagnostic sensitivity, specificity and accuracy of TTE were 92% (182/198), 81% (133/164) and 87% (315/362), respectively. In conclusion, MDCT angiogra- phy is a reliable, noninvasive imaging technique for the diagnosis of congenital aortic arch anomalies in children. Sometimes, even more information can be obtained from this technique than from conven- tional angiography. 展开更多
关键词 congenital anomalies multi-detector computed tomography angiography aortic arch
下载PDF
Segmental radiofrequency ablation of pulmonary vein ostia for patients with refractory paroxysmal atrial fibrillation using multi-slice spiral computed tomography guidance 被引量:6
8
作者 JIANG Chen-yang(蒋晨阳) +7 位作者 WANG Jian-an(王建安) HE Hong(何红) SUN Yong(孙勇) ZHOU Bin-quan(周斌全) 《Journal of Zhejiang University-Science B(Biomedicine & Biotechnology)》 SCIE CAS CSCD 2005年第12期1153-1156,共4页
Objective: To evaluate the safety and clinical efficacy of segmental radiofrequency ablation of pulmonary vein (PV)ostia for patients with refractory paroxysmal atrial fibrillation (AF) under multi-slice spiral comput... Objective: To evaluate the safety and clinical efficacy of segmental radiofrequency ablation of pulmonary vein (PV)ostia for patients with refractory paroxysmal atrial fibrillation (AF) under multi-slice spiral computed tomography (MSCT)guidance before the procedure. Methods: A series of 58 consecutive patients with refractory paroxysmal AF were enrolled to undergo segmental radiofrequency ablation ofPV ostia. The 36 male and 22 female patients with mean age of (57.4±9.5) (32~79)atrium (LA) and proximal PVs. Patients then underwent segmental radiofrequency ablation of PV ostia using PV circular mapping catheter manipulated several times to ensure complete isolation between PVs and LA. Results: No complications occurred during the procedure. One patient developed delayed cardiac tamponade, which was drained percutaneously. The mean follow-up time was (17.1±9.3) months. Forty-one patients (95%) experienced improved quality of life one month after the procedure. Thirty-six patients (83%) showed stable sinus rhythm, while 10 patients (23%) required additional anti-arrhythmic drugs. AF returned≥1time in 6 (14%) patients who underwent anti-arrhythmic drug therapy, but the number of episodes was less than that before the procedure. However, one patient experienced recurrent episodes of atrial flutter. Conclusion: It is safe and effective to perform segmental radiofrequency ablation of PV ostia for patients with refractory paroxysmal AF using MSCT guidance mappening. 展开更多
关键词 心室纤维颤动 肺静脉 消融术 X线断层摄影术 治疗方法
下载PDF
3D Reconstruction with Spiral Computed Tomography in Choroidal Osteoma 被引量:1
9
作者 Francisco Javier Ascaso Laura Herrera +4 位作者 Laura Villén Rafael Lasierra Juan Ibanez Diana Pérez José Angel Cristóbal 《Open Journal of Ophthalmology》 2013年第1期4-6,共3页
Choroidal osteoma (CO) is a rare, ossifying benign tumor originated in the choroid that typically occurs in otherwise healthy young women (1,2). It is characterized by a yellowish, well demarcated lesion in the juxtap... Choroidal osteoma (CO) is a rare, ossifying benign tumor originated in the choroid that typically occurs in otherwise healthy young women (1,2). It is characterized by a yellowish, well demarcated lesion in the juxtapapillary or macular area. The diagnosis is clinical and can be confirmed with the use of fluorescein or indocyanine angiography, optical coherence tomography, computed tomography or magnetic resonance imaging. Choroidal neovascularization or subretinal fluid, the main causes for vision loss, can be treated with laser therapy, photodynamic therapy or intravitreal antivascular endothelial growth factor therapy. We present a case of choroidal osteoma, showing the role of the high resolution 3D spiral computed tomography. 展开更多
关键词 Choroidal Osteoma 3D spiral Computed tomography ULTRASONOGRAPHY Fluorescein Angiography
下载PDF
A spontaneous strangulated transomental hernia: Prospective and retrospective multi-detector computed tomography findings
10
作者 Luigi Camera Angela De Gennaro +5 位作者 Margaret Longobardi Stefania Masone Emanuela Calabrese Walter Del Vecchio Giovanni Persico Marco Salvatore 《World Journal of Radiology》 CAS 2014年第2期26-30,共5页
Transomental hernias are among the rarest type of all internal hernias which overall account for less than 6% of small bowel obstructions. Most transomental hernias occurring in adults are either iatrogenic or post-tr... Transomental hernias are among the rarest type of all internal hernias which overall account for less than 6% of small bowel obstructions. Most transomental hernias occurring in adults are either iatrogenic or post-traumatic. More rarely, a spontaneous herniation of small bowel loops may result from senile atrophy of the omentum. We report a case of an 86-year-old male who presented with signs and symptoms of small bowel obstruction but had no past surgical or traumatic abdominal history. At contrast-enhanced multi-detector row computed tomography(CT), a cluster of fluid-filled dilated small bowel loops could be appreciated in the left flank, with associated signs of bowel wall ischemia. Swirling of the mesenteric vessels could also be appreciated and CT findings were prospectively considered consistent with a strangulated small bowel volvulus. At laparotomy, no derotation had to be performed but up to 100 cm of gangrenous small bowel loops had to be resected because of a transomental hernia through a small defect in the left part of the greater omentum. Retrospective reading of CT images was performed and findings suggestive of transomental herniation could then be appreciated. 展开更多
关键词 Small BOWEL OBSTRUCTION Internal HERNIAS Transomental HERNIA multi-detector row computed tomography STRANGULATION
下载PDF
Portal vein computed tomography imaging characteristics and their relationship with bleeding risk in patients with liver cirrhosis undergoing interventional therapy 被引量:1
11
作者 Xue-Jing Song Jing-Lei Liu +1 位作者 Shu-Ya Jia Kai Zhang 《World Journal of Clinical Cases》 SCIE 2023年第18期4277-4286,共10页
BACKGROUND This study aimed to analyze the predictive value of multi-slice spiral computed tomography(CT)perfusion imaging for upper gastrointestinal bleeding in patients with cirrhotic portal hypertension.A total of ... BACKGROUND This study aimed to analyze the predictive value of multi-slice spiral computed tomography(CT)perfusion imaging for upper gastrointestinal bleeding in patients with cirrhotic portal hypertension.A total of 62 patients with cirrhotic portal hypertension and 28 healthy individuals were included.The results showed that multi-slice spiral CT perfusion imaging had a significant predictive value for upper gastrointestinal bleeding in patients with cirrhotic portal hypertension.The vascular area,number of vascular cross-sections,and gastric coronary vein diameter(GCVD)showed high predictive values,with the vascular area having the best predictive value.AIM To investigate the predictive accuracy of multi-slice spiral CT perfusion imaging for upper gastrointestinal bleeding in patients with cirrhosis and portal hypertension.METHODS This study included 62 patients with cirrhotic portal hypertension(disease group)and 28 healthy individuals(control group).The disease group was further divided into two subgroups:Group A(n=27,bleeding)and group B(n=35,no bleeding).All patients underwent multi-slice spiral CT perfusion imaging at our hospital,and we compared various parameters such as liver blood flow,vein size,number of blood vessels,and blood vessel area between the two groups.We employed statistical analysis to identify factors associated with upper gastrointestinal bleeding and created a graph comparing the predictive value of different factors for bleeding.RESULTS We found no difference in hepatic artery(HAP)levels among the three groups(all P>0.05).The portal vein levels in groups A and B were much lower than in the control group;group A was much lower than group B(all P<0.05).The HAP perfusion index levels in groups A and B were much higher than in the control group;group A was much higher than group B(all P<0.05).The portal vein diameter,splenic vein diameter,and GCVD levels in groups A and B were much higher than in the control group;those in group A were much higher than those in group B(all P<0.05).The number of blood vessels and blood vessel area in groups A and B were much higher than in the control group;those in group A were much higher than those in group B(all P<0.05).The statistical method showed a strong link between GCVD,number of blood vessels,blood vessel area,and upper gastrointestinal bleeding(odds ratio=1.275,1.346,1.397,P<0.05).The graph showed that GCVD,number of blood vessels,and blood vessel area could predict bleeding well,with blood vessel area having the best prediction power.CONCLUSION That multi-slice spiral CT perfusion imaging can predict upper gastrointestinal bleeding well in patients with cirrhosis and high blood pressure in the portal vein.GCVD,number of blood vessels,and blood vessel area had high prediction power.The blood vessel area had the best prediction power,with an area under the curve of 0.831. 展开更多
关键词 Multi-slice spiral computed tomography PERFUSION CIRRHOSIS Portal hypertension Upper gastrointestinal bleeding Predictive value
下载PDF
Accuracy of linear vs spiral tomography:Alveolar crest to sinus/nasal floor height
12
作者 Mahsa Yoozbashizadeh Seyed Ahmad Fatemitabar +1 位作者 Ehsan Sedighara Arash Nikgoo 《World Journal of Stomatology》 2013年第4期91-96,共6页
AIM:To determine the accuracy of tomography in the linear measurement of alveolar bone at maxillary sinus/nose location.METHODS:Two dry skulls each marked with 10 pairs of guttaperchas placed on buccal and lingual sid... AIM:To determine the accuracy of tomography in the linear measurement of alveolar bone at maxillary sinus/nose location.METHODS:Two dry skulls each marked with 10 pairs of guttaperchas placed on buccal and lingual sides of the maxillary ridge were used in this in vitro study.The distance between the alveolar crest and the sinus/nasal floor was measured on tomographic views,prepared by linear and spiral techniques.The ridges were then sectioned so that each section would include one pair of buccal and lingual guttaperchas.The actual distances directly measured on the sections were compared to those of the equivalent tomographic sections(the magnification co-efficient was applied).Paired t-test was used to statistically analyze the data.RESULTS:The measurement error with the application of linear tomography and spiral tomography wasshown to be 0.455±0.838 mm(P=0.029)and 0.17±0.78 mm(P=0.347),respectively.There was a statistically significant difference between the liner tomography values and actual values(P=0.029).This difference was representative of underestimation.McNamara’s test was used to assess the±1 mm error;73.7%of the linear values and 84.2%of the spiral values were within the±1 mm error limit.Mc Namara’s test did not show any significant differences between the 2methods in this regard(P=0.625).The linear values were significantly different to the actual values(P=0.029)but not to the spiral values(P=0.185).CONCLUSION:Spiral tomography has enough accuracy for the measurement of alveolar ridge height.Although linear tomography somewhat underestimates the actual values it provides satisfactory accuracy. 展开更多
关键词 LINEAR tomography spiral tomography MAXILLARY SINUS Dental implants
下载PDF
Multi-Detector Row Computed Tomography Urography (MDCTU) in the Evaluation of Microscopic Hematuria in Adults
13
作者 Mohamed A. Mahmoud Mustafa Z. Mahmoud +3 位作者 Mohammed A. Ali Omer Mohamed E. M. Garalnabi Ahmed Abukonna Maram A. Fagiri 《Open Journal of Radiology》 2015年第1期20-27,共8页
Multi-detector row computed tomography urography (MDCTU) becomes the imaging modality of choice for evaluation of the kidneys and urinary tract. The aim of this study was to discuss and illustrate the role of MDCTU, o... Multi-detector row computed tomography urography (MDCTU) becomes the imaging modality of choice for evaluation of the kidneys and urinary tract. The aim of this study was to discuss and illustrate the role of MDCTU, on a 32-row CT scanner in the evaluation a variety of entities that were frequently associated with microscopic hematuria in adults. This prospective cohort study was performed in the period of August 2013 to October 2014. Fifty positive participants to microscopic hematuria were examined at the radiology department of Alnilin Diagnostic Medical Center and Antalya Medical Center. Computed tomography urography (CTU) scanning was performed using two powerful performances, high speed multi-detector row on 32-row CT scanners (Siemens Healthcare Global, Somatom Emotion Duo Eco). Statistical analysis was done through the standard Statistical Package for the Social Sciences (SPSS Inc., Chicago, IL, USA) version 15 for windows. MDCTU established the correct cause of microscopic hematuria in (44;88%) of participants. In (6;12%) of participants, no cause of hematuria was identified based on the standard of references. The causes of hematuria in (41;82%) participants were diseases in the upper urinary tract, while urinary bladder neoplasms (2;4%) and diverticulum (1;2%) were the causes of hematuria (3;6%) in the lower urinary tract. Thirty two-row MDCTU scanner demonstrated satisfactory results in the investigation of microscopic hematuria, being able to demonstrate a wide spectrum of diseases affecting the urinary tract is the main advantage of the technique. 展开更多
关键词 HEMATURIA Imaging Three-Dimensional multi-detector COMPUTED tomography UROLOGIC Diseases
下载PDF
Coronary arterial bypass graft patency evaluated by multi-detector computed tomography and magnetic resonance imaging
14
作者 Li Yang 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2007年第4期248-249,共2页
  The progression of atherosclerosis of the coronary artery does not stop after coronary arterial bypass grafting (CABG) surgery.……
关键词 CABG Coronary arterial bypass graft patency evaluated by multi-detector computed tomography and magnetic resonance imaging
下载PDF
Predictive Factors of the Presence and Number of Noncalcified Coronary Plaque in Japanese Patients with Zero Coronary Artery Calcium Score Using 64-Slice Multi-Detector Computed Tomography
15
作者 Yoshiki Noda Ryo Matsutera +8 位作者 Yoshinori Yasuoka Kiyoshi Kume Hidenori Adachi Susumu Hattori Ryo Araki Motohiro Kosugi Yasuaki Kohama Tetsufumi Nakashima Tatsuya Sasaki 《Advances in Computed Tomography》 2013年第3期112-120,共9页
Background: Factors that can predict the presence and number of noncalcified coronary plaques (NCP) in Japanese patients with zero coronary artery calcium scores (CACS) essentially remain undefined. Methods and Result... Background: Factors that can predict the presence and number of noncalcified coronary plaques (NCP) in Japanese patients with zero coronary artery calcium scores (CACS) essentially remain undefined. Methods and Results: We assessed independent predictors of the presence and number of segments with NCP in 111 Japanese patients with zero CACS who underwent 64-slice multi-detector computed tomography at our hospital. Thirty five patients (32%) had NCP, and 24 patients (22%) had ≥ 2 NCPs. Multiple logistic regression analysis revealed that significant predictors for the presence of NCP were age (odds ratio [OR]: 1.06, 95% confidence interval [CI] 1.01 - 1.11, p = 0.021), male (OR: 3.61, 95% CI 1.40 - 9.35, p = 0.008) and diabetes mellitus (OR: 3.10, 95% CI 1.02 - 9.45, p = 0.046), and those for the presence of ≥ 2 NCPs were age (OR: 1.08, 95% CI 1.02 - 1.15, p = 0.007) and a current smoking habit (OR: 5.09, 95% CI 1.00 - 25.74, p = 0.049). Multiple linear regression analysis identified advanced age, male gender and diabetes mellitus as independent predictors of the number of NCPs. A novel score calculated from the above four predictors showed moderate accuracy for a diagnosis of NCP and ≥ 2 NCPs, with areas under receiver operating curves of 0.738 and 0.736, respectively. Conclusions: Male Japanese patients with zero CACS, advanced age, diabetes mellitus and a current smoking habit might have NCPs. 展开更多
关键词 ZERO CORONARY Artery Calcium Score NUMBER of Noncalcified CORONARY PLAQUE 64-Slice multi-detector Computed tomography Japanese Patients
下载PDF
Computed tomography diagnosed left ovarian venous thrombophlebitis after vaginal delivery:A case report
16
作者 Jin-Jin Wang Chu-Chu Hui +1 位作者 Yi-Ding Ji Wei Xu 《World Journal of Clinical Cases》 SCIE 2023年第4期896-902,共7页
BACKGROUND Postpartum ovarian vein thrombophlebitis(POVT)is a rare but serious postpartum complication that affects mostly postpartum women.A high index of suspicion is required when faced with sudden postpartum abdom... BACKGROUND Postpartum ovarian vein thrombophlebitis(POVT)is a rare but serious postpartum complication that affects mostly postpartum women.A high index of suspicion is required when faced with sudden postpartum abdominal pain.CASE SUMMARY A 25-year-old healthy woman who accepted a vaginal delivery procedure suffered fever(temperature 39.6℃)one day after delivery,accompanied with left lower abdominal pain.Physical examination indicated mild tenderness in the left lower abdomen,accompanied with rebound pain.The patient was confirmed to have left ovarian venous thrombosis with inflammation after receiving a multidetector row computed tomography scan.CONCLUSION POVT is a rare and dangerous postpartum complication.A high index of suspicion is required for the occurrence of ovarian venous thrombosis when faced with postpartum abdominal pain and fever.Early application of Doppler ultrasound,computed tomography,magnetic resonance imaging and other auxiliary examinations is conducive to timely and accurate diagnosis of POVT,thus reducing maternal mortality. 展开更多
关键词 Ovarian venous thrombosis POSTPARTUM multi-detector row computed tomography Case report
下载PDF
CT双能量成像参数对肺结节病变性质的鉴别价值研究
17
作者 张东升 盛茂 +1 位作者 何家伟 陶磊 《中国临床医学影像杂志》 CAS CSCD 北大核心 2024年第6期406-410,共5页
目的:研究CT双能量成像参数对肺结节病变性质的鉴别价值。方法:2021年12月一2023年1月合肥市第二人民医院收治的102例恶性肺结节患者作为恶性组,同期收治的106例良性肺结节患者作为良性组,所有患者均经病理学检查确诊,比较两组患者影像... 目的:研究CT双能量成像参数对肺结节病变性质的鉴别价值。方法:2021年12月一2023年1月合肥市第二人民医院收治的102例恶性肺结节患者作为恶性组,同期收治的106例良性肺结节患者作为良性组,所有患者均经病理学检查确诊,比较两组患者影像学特征及CT双能量成像参数,进行肺结节病变性质的CT双能量成像征象、参数多因素分析,采用受试者工作特征(ROC)曲线分析CT双能量成像参数对肺结节病变性质的鉴别价值。结果:恶性组强化不均匀、淋巴结增大、结节边缘毛刺/分叶、血管受累患者占比高于良性组(P<0.05)。恶性组动脉期、静脉期能谱曲线斜率及容积CT剂量指数均高于良性组(P<0.05)。多因素Logistic回归分析结果显示,动脉期、静脉期能谱曲线斜率及容积CT剂量指数较高是肺结节恶性病变的危险因素(OR=1.451、1.502、1.640,P<0.05)。动脉期、静脉期能谱曲线斜率及容积CT剂量指数联合鉴别肺结节病变性质的曲线下面积(AUC)值高于三者单独检测(P<0.05)。结论:肺结节良性病变和恶性病变患者之间影像学特征、动脉期及静脉期能谱曲线斜率、容积CT剂量指数存在明显差异,且动脉期、静脉期能谱曲线斜率及容积CT剂量指数是肺结节恶性病变的危险因素,三者联合对肺结节病变性质的鉴别具有较好价值。 展开更多
关键词 肺肿瘤 体层摄影术 螺旋计算机
下载PDF
超高端螺旋CT单心跳心脏技术判别冠脉狭窄和斑块性质的临床价值及合并基础疾病对准确性的影响
18
作者 赵宇明 侯鹏 +2 位作者 王爽 纪俊雨 赵树媛 《中国临床医学影像杂志》 CAS CSCD 北大核心 2024年第1期46-50,共5页
目的:研究超高端螺旋CT单心跳心脏技术判别冠脉狭窄和斑块性质的临床价值及合并基础疾病对准确性的影响。方法:本研究采用前瞻性研究方法,以我院2022年7月—2023年1月诊断并进行治疗的冠心病患者96例作为研究对象,根据患者的冠脉狭窄程... 目的:研究超高端螺旋CT单心跳心脏技术判别冠脉狭窄和斑块性质的临床价值及合并基础疾病对准确性的影响。方法:本研究采用前瞻性研究方法,以我院2022年7月—2023年1月诊断并进行治疗的冠心病患者96例作为研究对象,根据患者的冠脉狭窄程度,Ⅰ级病变患者33例,Ⅱ级病变患者22例,Ⅲ级病变患者41例。根据斑块性质分析,其中稳定性斑块患者55例,不稳定性斑块患者41例,所有患者入组后均接受256排CT行单心跳心脏冠脉成像、冠脉造影(ICA)和血管内超声(IVUS)检查,比较单心跳心脏冠脉成像诊断冠脉血管狭窄以及不稳定性斑块的诊断效能,研究合并基础疾病对准确性的影响。结果:本研究中,单心跳心脏冠脉成像诊断冠脉血管狭窄Ⅲ级病变的灵敏度为80.49%,单心跳心脏冠脉成像诊断冠脉血管狭窄Ⅲ级病变的ROC曲线下面积为0.771,合并高血压、糖尿病、高脂血症等,会造成单心跳心脏冠脉成像诊断冠脉血管狭窄Ⅲ级病变的效能下降。单心跳心脏冠脉成像诊断冠脉血管不稳定斑块的灵敏度为80.21%,单心跳心脏冠脉成像诊断冠脉血管不稳定斑块的ROC曲线下面积为0.775,合并高血压、糖尿病、高脂血症等,会造成单心跳心脏冠脉成像诊断冠脉血管不稳定斑块的诊断效能下降。结论:超高端螺旋CT单心跳心脏技术判别冠脉狭窄和斑块性质的灵敏度均超过80%以上,合并高血压、糖尿病以及高脂血症患者,会造成冠脉狭窄和斑块性质的判定准确性以及灵敏度的下降。 展开更多
关键词 冠状动脉狭窄 冠心病 体层摄影术 螺旋计算机
下载PDF
CT与MRI在膝关节软骨损伤分级诊断中的效能分析
19
作者 李俊 周静仪 蔡世华 《中国临床医学影像杂志》 CAS CSCD 北大核心 2024年第8期585-588,共4页
目的:探究CT与MRI在膝关节软骨损伤分级诊断中的效能。方法:回顾性选取我院2021年1月-2023年1月收治的80例膝关节软骨损伤患者为研究对象,对所有患者行CT、MRI和关节镜检查,通过关节镜检查的结果,评估二者的分级诊断效能,并比较CT与MRI... 目的:探究CT与MRI在膝关节软骨损伤分级诊断中的效能。方法:回顾性选取我院2021年1月-2023年1月收治的80例膝关节软骨损伤患者为研究对象,对所有患者行CT、MRI和关节镜检查,通过关节镜检查的结果,评估二者的分级诊断效能,并比较CT与MRI在膝关节软骨损伤分级诊断中的诊断价值。结果:患者经CT检查诊断的分级结果为Ⅰ级28例,Ⅰ级34例,Ⅲ级及以上18例;经MRI检查诊断的分级结果为Ⅰ级31例,Ⅱ级29例,Ⅲ级及以上20例。与关节镜检查的结果对比,CT的分级诊断准确率为81.25%(65/80),MRI的分级诊断准确率为95.00%(76/80)。MRI检查诊断膝关节软骨损伤患者的I级诊断准确率、总准确率要高于CT检查,差异有统计学意义(P<0.05)。结论:CT与MRI均可对膝关节软骨损伤进行分级诊断,但MRI对膝关节软骨损伤分级的诊断准确率高于CT,具有更高的诊断效能。 展开更多
关键词 膝关节 创伤和损伤 体层摄影术 螺旋计算机 磁共振成像
下载PDF
螺旋CT三维扫描重建联合3D打印用于髋臼骨折手术的价值研究
20
作者 王姗姗 牛俊巧 +3 位作者 王佳 李小娟 洪悦 王利 《中国医学装备》 2024年第5期59-63,共5页
目的:探讨螺旋CT三维扫描重建联合3D打印技术在髋臼骨折外科手术中的应用价值。方法:选取2018年1月至2020年12月新疆维吾尔自治区人民医院收治的71例髋臼骨折并接受手术治疗的患者,依据治疗方式的不同将其分为观察组(38例)和对照组(33... 目的:探讨螺旋CT三维扫描重建联合3D打印技术在髋臼骨折外科手术中的应用价值。方法:选取2018年1月至2020年12月新疆维吾尔自治区人民医院收治的71例髋臼骨折并接受手术治疗的患者,依据治疗方式的不同将其分为观察组(38例)和对照组(33例),观察组采用螺旋CT三维重建,并以3D打印辅助内固定治疗,对照组采用常规手术治疗。比较两组患者手术效果及恢复情况。结果:观察组骨折复位质量评分及分项百分制髋功能评分高于对照组,术中出血量、术中透视次数、手术用时及住院时间均明显低于对照组,差异均有统计学意义(t=23.426、4.216、3.425、17.783,P<0.05);观察组和对照组骨折复位优良率分别为94.74%和78.79%,差异有统计学意义(x^(2)=4.059,P<0.05);观察组患者髋关节功能评分中疼痛、功能及关节活动均高于对照组,差异有统计学意义(t=-4.873、-5.776、-6.247,P<0.05);观察组并发症发生率明显低于对照组,差异有统计学意义(x^(2)=4.059,P<0.05)。结论:在髋臼骨折围术期应用螺旋CT三维重建结合3D打印可进一步保证手术的安全性和可行性,提高手术质量和效率,促进术后恢复。 展开更多
关键词 螺旋CT 三维重建 3D打印 髋臼骨折
下载PDF
上一页 1 2 204 下一页 到第
使用帮助 返回顶部