This paper proposes a new Predictive Direct Power Control(P-DPC) solution for three-phase grid-connected inverters, which combines direct power control strategy with the predictive control strategy and space vector pu...This paper proposes a new Predictive Direct Power Control(P-DPC) solution for three-phase grid-connected inverters, which combines direct power control strategy with the predictive control strategy and space vector pulse width modulation(SVPWM), obtaining both high transient performance and a constant switching frequency. This control solution can achieve decoupling control for active and reactive power and an adjustable power factor. Meanwhile, the grid-connected current can approximately be sinusoidal. The feasibility and advantages of the control strategy are verified by the simulation and experiment compared with another existing P-DPC.展开更多
In wind power generation system the grid-connected inverter is an important section for energy conversion and transmission, of which the performance has a direct influence on the entire wind power generation system. T...In wind power generation system the grid-connected inverter is an important section for energy conversion and transmission, of which the performance has a direct influence on the entire wind power generation system. The mathematical model of the grid-connected inverter is deduced firstly. Then, the space vector pulse width modulation (SVPWM) is analyzed. The power factor can be controlled close to unity, leading or lagging, which is realized based on H-type current controller and grid voltage vector-oriented control. The control strategy is verified by the simulation and experimental results with a good sinusoidal current, a small harmonic component and a fast dynamic response.展开更多
The overall performance of photovoltaic (PV) inverter imphes many different technical issues.One of the key criterias is based on the measurement of the conversion and the maximum power point tracking (MPPT) effic...The overall performance of photovoltaic (PV) inverter imphes many different technical issues.One of the key criterias is based on the measurement of the conversion and the maximum power point tracking (MPPT) efficiency and its applicable evaluation in practice.Intense work has been done in the last few years to formulate applicable standards for measuring static and dynamic efficiencies worldwide.Besides that,this work is presenting on novel methods of analysis on non-trivial system characteristics impacting the final evaluation on the overall performance of the PV inverter.The elaborated testing procedures for complex system behavior under highly nonlinear conditions (unintentional partial shading, mismatching of DC strings) are explained and characterized.With the help of experimental results, the exclusive impact on the overall efficiency is illustrated and helpful statements are given on the resulting technical characteristics of MPP strategies.展开更多
This research paper proposes a single phase fifteen level inverter for a grid connected PV system.The proposed inverter is also called cascaded asymmetric multilevel inverter.By adopting appropriate hybrid modulation ...This research paper proposes a single phase fifteen level inverter for a grid connected PV system.The proposed inverter is also called cascaded asymmetric multilevel inverter.By adopting appropriate hybrid modulation technique improved output voltage is obtained with minimum number of power electronic switches.By reducing the number of gate triggering circuits of the switches,the size and power consumption of the driving circuits can be reduced.The total harmonic distortion of the output of the inverter is improved by this inverter.The proposed inverter developed by cascading a full bridge inverter with modified H bridge multilevel inverter.The validity of the proposed system is verified through MATLAB simulations.展开更多
There has been a noticeable increase in use of Solar PV based systems for power generation, given its renewable nature. A solar PV based grid tie inverters are used for dc-ac conversion. The conventional line commutat...There has been a noticeable increase in use of Solar PV based systems for power generation, given its renewable nature. A solar PV based grid tie inverters are used for dc-ac conversion. The conventional line commutated ac-to-dc inverters have square-shaped line current which contains higher-order harmonics. The line current with the high harmonic contents generates EMI and moreover it causes more heating of the core of distribution/power transformers. Alternatively, PWM based inverters using MOSFET/IGBT switches are also used for the same purpose. However, apart from higher switching losses, the power handling capability and reliability of these devices are quite low in comparison to thyristors/SCR. Nevertheless, the conventional thyristor based forced commutated inverters are not suitable for PWM applications due to the problems of commutation circuits. A pure sinusoidal line current or waveform with low har- monic contents is the most desirable. In the present work, a multilevel line commutated inverter topology has been proposed and analyzed which improves the wave shape and hence reduces the total harmonic distortion (THD) of the line current in a grid tie line commutated inverter. The scheme has successfully been implemented and tested. Moreover, the performance of the proposed topology is far better than the conventional line-commutated inverter. It reduces THD, losses, switching stress and EMI.展开更多
A novel topology of the current-source grid-connected inverter is proposed based on the immittance converter theory. A control strategy of sine-sine pulse width modulation (PWM) is studied. Compared with the traditi...A novel topology of the current-source grid-connected inverter is proposed based on the immittance converter theory. A control strategy of sine-sine pulse width modulation (PWM) is studied. Compared with the traditional current-source inverter, the power frequency inductors and power frequency transformer are replaced with high frequency inductors and a high frequency transformer. Thus, the proposed inverter has advantages of small volume, low cost, low total harmonic distortion (THD), low power losses, high power factor (PF) and simple control. Furthermore, grid voltage cannot influence output current of the grid-connected inverter and the current-source inverter with a high PF that approaches one has been realized. Finally, validity of the theory analysis and feasibility of the control scheme are shown by simulation and experimental results.展开更多
This paper presents the results of research on the application of inverter in the grid connected solar photovoltaics (PV) system. The main content of the article is to control the three-phase grid connected inverter t...This paper presents the results of research on the application of inverter in the grid connected solar photovoltaics (PV) system. The main content of the article is to control the three-phase grid connected inverter to meet the requirement of controlling the reactive power to zero at a node of the distribution network while maximizing the active power transmitted to the grid. The control circuits are synthesized on the dq coordinate system and verified on the simulation model by Matlab/Simulink. Both simulation and experimental prototype on 5 kW inverter, being connected to low voltage grid, have been built to show the good results and the practical readiness for implementation.展开更多
As to the concrete topology of three-phase LCL type grid-connected inverter with damping resistance, mathematical model was deduced in detail, using method of equivalent transformation to the structure diagram, dampin...As to the concrete topology of three-phase LCL type grid-connected inverter with damping resistance, mathematical model was deduced in detail, using method of equivalent transformation to the structure diagram, damping resistance was virtualized, mathematical model under the DQ frame that can realize decoupling control was established, a dual-loop control strategy for grid-connected inverter with LCL filter was proposed, the system stability was analyzed and the design method of controller was given. The proposed method overcame the flaws of loss increase, efficiency reduce and cost increase which were caused by damping resistance in LCL type grid-connected inverter, the system efficiency and power supply quality of the output were improved. Feasibility and effectiveness of the new method were validated by simulation and experimental results.展开更多
This paper presents, tests and compares three earthing systems (TT, TN and IT) for Micro-Grid (MG) protection against various fault types during the connected mode. The main contribution of this work is including the ...This paper presents, tests and compares three earthing systems (TT, TN and IT) for Micro-Grid (MG) protection against various fault types during the connected mode. The main contribution of this work is including the models of all the micro sources which interfaced to the MG by power electronic inverters. Inverters in turns are provided with current limiters and this also included in the inverter models to exactly simulate the real situation in the MG during fault times. Results proved that the most suitable earthing system for MG protection during the connecting mode is the TN earthing system. That system leads to a suitable amount of fault current sufficient to activate over current protection relays. With using TN system, Touch voltages at the faulted bus and all other consumer’s buses are less than the safety limited value if current limiter is included with the transformer of the main grid which connects MG. For the two others earthing systems (TT and IT), fault current is small and nearly equal to the over load current which make over current protection relay can not differentiate between fault current and overload current. All models of micro sources, earthing systems, inverters, main grid and control schemes are built using Matlab?/Simulink? environment.展开更多
This paper presents a simple approach of a topology already known in the literature, applied in active power transfer from direct current source to any alternating current voltage source, whether the utility power or ...This paper presents a simple approach of a topology already known in the literature, applied in active power transfer from direct current source to any alternating current voltage source, whether the utility power or a voltage inverter that is forming an isolated AC grid. The photovoltaic inverter works as current controlled voltage source inverter that provides a sinusoidal current to the AC grid. The inverter is insulated from the grid by a transformer. The system is discussed and modeled. Simulation results of this application are presented and experimental results validate this topology.展开更多
基金supported by the national 863 program (2011AA050204)
文摘This paper proposes a new Predictive Direct Power Control(P-DPC) solution for three-phase grid-connected inverters, which combines direct power control strategy with the predictive control strategy and space vector pulse width modulation(SVPWM), obtaining both high transient performance and a constant switching frequency. This control solution can achieve decoupling control for active and reactive power and an adjustable power factor. Meanwhile, the grid-connected current can approximately be sinusoidal. The feasibility and advantages of the control strategy are verified by the simulation and experiment compared with another existing P-DPC.
基金supported by Delta Power Electronic Science and Education Development in 2007 (Grant No.DRES2007002)
文摘In wind power generation system the grid-connected inverter is an important section for energy conversion and transmission, of which the performance has a direct influence on the entire wind power generation system. The mathematical model of the grid-connected inverter is deduced firstly. Then, the space vector pulse width modulation (SVPWM) is analyzed. The power factor can be controlled close to unity, leading or lagging, which is realized based on H-type current controller and grid voltage vector-oriented control. The control strategy is verified by the simulation and experimental results with a good sinusoidal current, a small harmonic component and a fast dynamic response.
文摘The overall performance of photovoltaic (PV) inverter imphes many different technical issues.One of the key criterias is based on the measurement of the conversion and the maximum power point tracking (MPPT) efficiency and its applicable evaluation in practice.Intense work has been done in the last few years to formulate applicable standards for measuring static and dynamic efficiencies worldwide.Besides that,this work is presenting on novel methods of analysis on non-trivial system characteristics impacting the final evaluation on the overall performance of the PV inverter.The elaborated testing procedures for complex system behavior under highly nonlinear conditions (unintentional partial shading, mismatching of DC strings) are explained and characterized.With the help of experimental results, the exclusive impact on the overall efficiency is illustrated and helpful statements are given on the resulting technical characteristics of MPP strategies.
文摘This research paper proposes a single phase fifteen level inverter for a grid connected PV system.The proposed inverter is also called cascaded asymmetric multilevel inverter.By adopting appropriate hybrid modulation technique improved output voltage is obtained with minimum number of power electronic switches.By reducing the number of gate triggering circuits of the switches,the size and power consumption of the driving circuits can be reduced.The total harmonic distortion of the output of the inverter is improved by this inverter.The proposed inverter developed by cascading a full bridge inverter with modified H bridge multilevel inverter.The validity of the proposed system is verified through MATLAB simulations.
文摘There has been a noticeable increase in use of Solar PV based systems for power generation, given its renewable nature. A solar PV based grid tie inverters are used for dc-ac conversion. The conventional line commutated ac-to-dc inverters have square-shaped line current which contains higher-order harmonics. The line current with the high harmonic contents generates EMI and moreover it causes more heating of the core of distribution/power transformers. Alternatively, PWM based inverters using MOSFET/IGBT switches are also used for the same purpose. However, apart from higher switching losses, the power handling capability and reliability of these devices are quite low in comparison to thyristors/SCR. Nevertheless, the conventional thyristor based forced commutated inverters are not suitable for PWM applications due to the problems of commutation circuits. A pure sinusoidal line current or waveform with low har- monic contents is the most desirable. In the present work, a multilevel line commutated inverter topology has been proposed and analyzed which improves the wave shape and hence reduces the total harmonic distortion (THD) of the line current in a grid tie line commutated inverter. The scheme has successfully been implemented and tested. Moreover, the performance of the proposed topology is far better than the conventional line-commutated inverter. It reduces THD, losses, switching stress and EMI.
基金supported by the Shanghai Leading Academic Discipline Project (Grant No.T0103)
文摘A novel topology of the current-source grid-connected inverter is proposed based on the immittance converter theory. A control strategy of sine-sine pulse width modulation (PWM) is studied. Compared with the traditional current-source inverter, the power frequency inductors and power frequency transformer are replaced with high frequency inductors and a high frequency transformer. Thus, the proposed inverter has advantages of small volume, low cost, low total harmonic distortion (THD), low power losses, high power factor (PF) and simple control. Furthermore, grid voltage cannot influence output current of the grid-connected inverter and the current-source inverter with a high PF that approaches one has been realized. Finally, validity of the theory analysis and feasibility of the control scheme are shown by simulation and experimental results.
文摘This paper presents the results of research on the application of inverter in the grid connected solar photovoltaics (PV) system. The main content of the article is to control the three-phase grid connected inverter to meet the requirement of controlling the reactive power to zero at a node of the distribution network while maximizing the active power transmitted to the grid. The control circuits are synthesized on the dq coordinate system and verified on the simulation model by Matlab/Simulink. Both simulation and experimental prototype on 5 kW inverter, being connected to low voltage grid, have been built to show the good results and the practical readiness for implementation.
文摘As to the concrete topology of three-phase LCL type grid-connected inverter with damping resistance, mathematical model was deduced in detail, using method of equivalent transformation to the structure diagram, damping resistance was virtualized, mathematical model under the DQ frame that can realize decoupling control was established, a dual-loop control strategy for grid-connected inverter with LCL filter was proposed, the system stability was analyzed and the design method of controller was given. The proposed method overcame the flaws of loss increase, efficiency reduce and cost increase which were caused by damping resistance in LCL type grid-connected inverter, the system efficiency and power supply quality of the output were improved. Feasibility and effectiveness of the new method were validated by simulation and experimental results.
文摘This paper presents, tests and compares three earthing systems (TT, TN and IT) for Micro-Grid (MG) protection against various fault types during the connected mode. The main contribution of this work is including the models of all the micro sources which interfaced to the MG by power electronic inverters. Inverters in turns are provided with current limiters and this also included in the inverter models to exactly simulate the real situation in the MG during fault times. Results proved that the most suitable earthing system for MG protection during the connecting mode is the TN earthing system. That system leads to a suitable amount of fault current sufficient to activate over current protection relays. With using TN system, Touch voltages at the faulted bus and all other consumer’s buses are less than the safety limited value if current limiter is included with the transformer of the main grid which connects MG. For the two others earthing systems (TT and IT), fault current is small and nearly equal to the over load current which make over current protection relay can not differentiate between fault current and overload current. All models of micro sources, earthing systems, inverters, main grid and control schemes are built using Matlab?/Simulink? environment.
文摘This paper presents a simple approach of a topology already known in the literature, applied in active power transfer from direct current source to any alternating current voltage source, whether the utility power or a voltage inverter that is forming an isolated AC grid. The photovoltaic inverter works as current controlled voltage source inverter that provides a sinusoidal current to the AC grid. The inverter is insulated from the grid by a transformer. The system is discussed and modeled. Simulation results of this application are presented and experimental results validate this topology.