Laser tracers are a three-dimensional coordinate measurement system that are widely used in industrial measurement.We propose a geometric error identification method based on multi-station synchronization laser tracer...Laser tracers are a three-dimensional coordinate measurement system that are widely used in industrial measurement.We propose a geometric error identification method based on multi-station synchronization laser tracers to enable the rapid and high-precision measurement of geometric errors for gantry-type computer numerical control(CNC)machine tools.This method also improves on the existing measurement efficiency issues in the single-base station measurement method and multi-base station time-sharing measurement method.We consider a three-axis gantry-type CNC machine tool,and the geometric error mathematical model is derived and established based on the combination of screw theory and a topological analysis of the machine kinematic chain.The four-station laser tracers position and measurement points are realized based on the multi-point positioning principle.A self-calibration algorithm is proposed for the coordinate calibration process of a laser tracer using the Levenberg-Marquardt nonlinear least squares method,and the geometric error is solved using Taylor’s first-order linearization iteration.The experimental results show that the geometric error calculated based on this modeling method is comparable to the results from the Etalon laser tracer.For a volume of 800 mm×1000 mm×350 mm,the maximum differences of the linear,angular,and spatial position errors were 2.0μm,2.7μrad,and 12.0μm,respectively,which verifies the accuracy of the proposed algorithm.This research proposes a modeling method for the precise measurement of errors in machine tools,and the applied nature of this study also makes it relevant both to researchers and those in the industrial sector.展开更多
<strong>Objective:</strong> Explore the rule of autonomic nervous dysfunction in the patients with urination disorder after high level spinal cord injury, and seek a safe, objective and accurate method to ...<strong>Objective:</strong> Explore the rule of autonomic nervous dysfunction in the patients with urination disorder after high level spinal cord injury, and seek a safe, objective and accurate method to evaluate autonomic nervous function. <strong>Patients and Method:</strong> 48 patients with dysuria after cervicothoracic SCI were selected. Before, during and after imaging urodynamic examination with slow filling in supine position, blood pressure and ECG were monitored simultaneously. The symptoms of sweating, shivering, headache, flushing and chills were observed and recorded. The study of the relationship among the changes of blood pressure, heart rate and urodynamic indexes and the above symptoms was analyzed. <strong>Results:</strong> They were divided into three groups: group A (no obvious abnormality), group B (hyperactivity) and group C (hypoactivity) according to their BP, HR and existing the symptoms or not. <strong>Conclusion:</strong> The incidence of autonomic dysfunction in the high level SCI patients with dysuria was very high (79.17%), most of them were hyperactivity, and a few were low function. The changes of SBP and DBP in the hypoactivity group all appeared an increasing and then declining trend, while the change of HR in the low function one was lower than normal and decreased continuously. The main inducements of AD are neurogenic detrusor overactivity, detrusor sphincter dyssynergia, elevated abdominal pressure and abnormal bladder sensitivity. The asymptomatic patients had a higher occurrence rate (43.75%). Only by imaging urodynamic examination with slow filling and synchronous blood pressure monitoring, can autonomic nervous function of the patients be evaluated safely, objectively, early and accurately.展开更多
In order to eliminate the influence of frequency change on real-time voltage acquisition,a low-cost solution of voltage monitoring was proposed using the multi-channel DMA synchronous frequency trace-sampling techniqu...In order to eliminate the influence of frequency change on real-time voltage acquisition,a low-cost solution of voltage monitoring was proposed using the multi-channel DMA synchronous frequency trace-sampling technique.In-chip resources of the designed voltage monitor were fully utilized in hardware design to reduce external devices.The MQX RTOS was used to perform the functional tasks flexibly and efficiently;especially the Ethernet communication applications and USB device connection were realized using its TCP/IP protocol stack and USB driver.In addition,to ensure the safety of electrical records,data statistics and alarm information management were also implemented through the management of the storage in FLASH.The test results show that the voltage monitor designed in this paper has the advantages of accurate measurement,strong resistance to frequency interference and low cost,and can be widely applied in the field of voltage monitoring in distribution networks.展开更多
Cable-membrane structures have small rigidity and are highly sensitive to wind. Structural health monitoring is necessary to ensure the serviceability and safety of the structure. In this research, the design method o...Cable-membrane structures have small rigidity and are highly sensitive to wind. Structural health monitoring is necessary to ensure the serviceability and safety of the structure. In this research, the design method of a structural health monitoring system is using the characteristics of a cable-membrane structure. Taking the Yueyang Sanhe Airport Terminal as an example, a finite element model is established to determine the critical structural components. Next, the engineering requirements and the framework of the monitoring system are studied based on the results of numerical analysis. The specific implementation of the structural health monitoring is then carried out, which includes sensor selection, installation and wiring. The proposed framework is successfully applied to the monitoring system for the Yueyang Airport terminal building, and the synchronous acquisition of fiber Bragg grating and acceleration sensor signals is implemented in an innovative way. The successful implementation and operation of structural health monitoring will help to guarantee the safety of the cablemembrane structure during its service life.展开更多
为了研究冷金属与脉冲复合焊(cold metal transfer and pulse,CMT+P)的焊接行为,使用PCI数据采集卡、高速相机、红外成像仪及声发射采集系统对焊接过程进行同步监测.发现脉冲射滴过渡发生前,焊机输出电流突增,同时焊丝尖端释放猛烈电弧...为了研究冷金属与脉冲复合焊(cold metal transfer and pulse,CMT+P)的焊接行为,使用PCI数据采集卡、高速相机、红外成像仪及声发射采集系统对焊接过程进行同步监测.发现脉冲射滴过渡发生前,焊机输出电流突增,同时焊丝尖端释放猛烈电弧光,随后熔滴滴入焊道,熔池温度增加,声发射(acoustic emission,AE)信号显示出1个波峰.发生CMT短路过渡时,焊机输出电流同时为焊丝熔化和焊丝伸出提供能量,待到焊丝尖端接触基板瞬间形成短路,熔池温度持续降低,AE信号微弱,伴随着熔滴因过热收缩而爆断,熔滴短路过渡完成.对AE信号进行离散傅里叶变换(discrete Fourier transform,DFT)后,可通过特征频率对CMT+P各个周期及阶段进行过程识别.结果表明,575 kHz和415 kHz可作为脉冲电弧周期和CMT短路周期的特征频率,推断180 kHz是脉冲电弧的特有频率,575 kHz的频率则是基础电弧提供,415 kHz处的频率则在CMT短路接触瞬间产生.展开更多
The synchronous monitoring of cerebral blood flow and blood oxygen levels plays a pivotal role in the prevention,diagnosis,and treatment of cerebrovascular diseases.This study introduces a novel noninvasive device uti...The synchronous monitoring of cerebral blood flow and blood oxygen levels plays a pivotal role in the prevention,diagnosis,and treatment of cerebrovascular diseases.This study introduces a novel noninvasive device utilizing inductive sensing and near-infrared spectroscopy technology to facilitate simultaneous monitoring of cerebral blood flow and blood oxygen levels.The device consists of modules for cerebral blood flow monitoring,cerebral blood oxygen monitoring,control,communication,and a host machine.Through experiments conducted on healthy subjects,it was confirmed that the device can effectively achieve synchronous monitoring and recording of cerebral blood flow and blood oxygen signals.The results demonstrate the device’s capability to accurately measure these signals simultaneously.This technology enables dynamic monitoring of cerebral blood flow and blood oxygen signals with potential clinical applications in preventing,diagnosing,treating cerebrovascular diseases while reducing their associated harm.展开更多
时间同步技术作为无线微震传感器网络的核心技术之一,是网络协调运行的关键。首先研究了无线传感器网络时间同步原理及影响同步精度的因素;其次研究了经典无线时间同步协的实现方法;然后仿真对比了传感器网络时间同步协议(Timing-sync P...时间同步技术作为无线微震传感器网络的核心技术之一,是网络协调运行的关键。首先研究了无线传感器网络时间同步原理及影响同步精度的因素;其次研究了经典无线时间同步协的实现方法;然后仿真对比了传感器网络时间同步协议(Timing-sync Protocol for Sensor Networks,TPSN)和泛洪式时间同步协议(Flooding Time Synchronization Protocol,FTSP)的同步精度;再针对FTSP协议的不足提出一种改进的G-FTSP协议,能有效提高无线传感器网络时间同步精度;最后估算由时间同步误差造成的微震震源定位误差,验证G-FTSP协议满足实际生产需求。展开更多
基金Supported by Natural Science Foundation of Shaanxi Province of China(Grant No.2021JM010)Suzhou Municipal Natural Science Foundation of China(Grant Nos.SYG202018,SYG202134).
文摘Laser tracers are a three-dimensional coordinate measurement system that are widely used in industrial measurement.We propose a geometric error identification method based on multi-station synchronization laser tracers to enable the rapid and high-precision measurement of geometric errors for gantry-type computer numerical control(CNC)machine tools.This method also improves on the existing measurement efficiency issues in the single-base station measurement method and multi-base station time-sharing measurement method.We consider a three-axis gantry-type CNC machine tool,and the geometric error mathematical model is derived and established based on the combination of screw theory and a topological analysis of the machine kinematic chain.The four-station laser tracers position and measurement points are realized based on the multi-point positioning principle.A self-calibration algorithm is proposed for the coordinate calibration process of a laser tracer using the Levenberg-Marquardt nonlinear least squares method,and the geometric error is solved using Taylor’s first-order linearization iteration.The experimental results show that the geometric error calculated based on this modeling method is comparable to the results from the Etalon laser tracer.For a volume of 800 mm×1000 mm×350 mm,the maximum differences of the linear,angular,and spatial position errors were 2.0μm,2.7μrad,and 12.0μm,respectively,which verifies the accuracy of the proposed algorithm.This research proposes a modeling method for the precise measurement of errors in machine tools,and the applied nature of this study also makes it relevant both to researchers and those in the industrial sector.
文摘<strong>Objective:</strong> Explore the rule of autonomic nervous dysfunction in the patients with urination disorder after high level spinal cord injury, and seek a safe, objective and accurate method to evaluate autonomic nervous function. <strong>Patients and Method:</strong> 48 patients with dysuria after cervicothoracic SCI were selected. Before, during and after imaging urodynamic examination with slow filling in supine position, blood pressure and ECG were monitored simultaneously. The symptoms of sweating, shivering, headache, flushing and chills were observed and recorded. The study of the relationship among the changes of blood pressure, heart rate and urodynamic indexes and the above symptoms was analyzed. <strong>Results:</strong> They were divided into three groups: group A (no obvious abnormality), group B (hyperactivity) and group C (hypoactivity) according to their BP, HR and existing the symptoms or not. <strong>Conclusion:</strong> The incidence of autonomic dysfunction in the high level SCI patients with dysuria was very high (79.17%), most of them were hyperactivity, and a few were low function. The changes of SBP and DBP in the hypoactivity group all appeared an increasing and then declining trend, while the change of HR in the low function one was lower than normal and decreased continuously. The main inducements of AD are neurogenic detrusor overactivity, detrusor sphincter dyssynergia, elevated abdominal pressure and abnormal bladder sensitivity. The asymptomatic patients had a higher occurrence rate (43.75%). Only by imaging urodynamic examination with slow filling and synchronous blood pressure monitoring, can autonomic nervous function of the patients be evaluated safely, objectively, early and accurately.
文摘In order to eliminate the influence of frequency change on real-time voltage acquisition,a low-cost solution of voltage monitoring was proposed using the multi-channel DMA synchronous frequency trace-sampling technique.In-chip resources of the designed voltage monitor were fully utilized in hardware design to reduce external devices.The MQX RTOS was used to perform the functional tasks flexibly and efficiently;especially the Ethernet communication applications and USB device connection were realized using its TCP/IP protocol stack and USB driver.In addition,to ensure the safety of electrical records,data statistics and alarm information management were also implemented through the management of the storage in FLASH.The test results show that the voltage monitor designed in this paper has the advantages of accurate measurement,strong resistance to frequency interference and low cost,and can be widely applied in the field of voltage monitoring in distribution networks.
基金National Natural Science Foundation of China under Grant Nos.51708088 and 51625802the Foundation for High Level Talent Innovation Support Program of Dalian under Grant No.2017RD03
文摘Cable-membrane structures have small rigidity and are highly sensitive to wind. Structural health monitoring is necessary to ensure the serviceability and safety of the structure. In this research, the design method of a structural health monitoring system is using the characteristics of a cable-membrane structure. Taking the Yueyang Sanhe Airport Terminal as an example, a finite element model is established to determine the critical structural components. Next, the engineering requirements and the framework of the monitoring system are studied based on the results of numerical analysis. The specific implementation of the structural health monitoring is then carried out, which includes sensor selection, installation and wiring. The proposed framework is successfully applied to the monitoring system for the Yueyang Airport terminal building, and the synchronous acquisition of fiber Bragg grating and acceleration sensor signals is implemented in an innovative way. The successful implementation and operation of structural health monitoring will help to guarantee the safety of the cablemembrane structure during its service life.
文摘为了研究冷金属与脉冲复合焊(cold metal transfer and pulse,CMT+P)的焊接行为,使用PCI数据采集卡、高速相机、红外成像仪及声发射采集系统对焊接过程进行同步监测.发现脉冲射滴过渡发生前,焊机输出电流突增,同时焊丝尖端释放猛烈电弧光,随后熔滴滴入焊道,熔池温度增加,声发射(acoustic emission,AE)信号显示出1个波峰.发生CMT短路过渡时,焊机输出电流同时为焊丝熔化和焊丝伸出提供能量,待到焊丝尖端接触基板瞬间形成短路,熔池温度持续降低,AE信号微弱,伴随着熔滴因过热收缩而爆断,熔滴短路过渡完成.对AE信号进行离散傅里叶变换(discrete Fourier transform,DFT)后,可通过特征频率对CMT+P各个周期及阶段进行过程识别.结果表明,575 kHz和415 kHz可作为脉冲电弧周期和CMT短路周期的特征频率,推断180 kHz是脉冲电弧的特有频率,575 kHz的频率则是基础电弧提供,415 kHz处的频率则在CMT短路接触瞬间产生.
基金National Natural Science Foundation of China(No.51977214)Science and Technology Research Project of Chongqing Education Commission(No.KJQN202212805)Special funding project of Army Medical University(No.2021XJS08)。
文摘The synchronous monitoring of cerebral blood flow and blood oxygen levels plays a pivotal role in the prevention,diagnosis,and treatment of cerebrovascular diseases.This study introduces a novel noninvasive device utilizing inductive sensing and near-infrared spectroscopy technology to facilitate simultaneous monitoring of cerebral blood flow and blood oxygen levels.The device consists of modules for cerebral blood flow monitoring,cerebral blood oxygen monitoring,control,communication,and a host machine.Through experiments conducted on healthy subjects,it was confirmed that the device can effectively achieve synchronous monitoring and recording of cerebral blood flow and blood oxygen signals.The results demonstrate the device’s capability to accurately measure these signals simultaneously.This technology enables dynamic monitoring of cerebral blood flow and blood oxygen signals with potential clinical applications in preventing,diagnosing,treating cerebrovascular diseases while reducing their associated harm.
文摘时间同步技术作为无线微震传感器网络的核心技术之一,是网络协调运行的关键。首先研究了无线传感器网络时间同步原理及影响同步精度的因素;其次研究了经典无线时间同步协的实现方法;然后仿真对比了传感器网络时间同步协议(Timing-sync Protocol for Sensor Networks,TPSN)和泛洪式时间同步协议(Flooding Time Synchronization Protocol,FTSP)的同步精度;再针对FTSP协议的不足提出一种改进的G-FTSP协议,能有效提高无线传感器网络时间同步精度;最后估算由时间同步误差造成的微震震源定位误差,验证G-FTSP协议满足实际生产需求。