There is a growing need to explore the potential of coal-fired power plants(CFPPs)to enhance the utilization rate of wind power(wind)and photovoltaic power(PV)in the green energy field.This study developed a load regu...There is a growing need to explore the potential of coal-fired power plants(CFPPs)to enhance the utilization rate of wind power(wind)and photovoltaic power(PV)in the green energy field.This study developed a load regulation model for a multi-power generation system comprising wind,PV,and coal energy storage using realworld data.The power supply process was divided into eight fundamental load regulation scenarios,elucidating the influence of each scenario on load regulation.Within the framework of the multi-power generation system with the wind(50 MW)and PV(50 MW)alongside a CFPP(330 MW),a lithium-iron phosphate energy storage system(LIPBESS)was integrated to improve the system’s load regulation flexibility.The energy storage operation strategy was formulated based on the charging and discharging priority of the LIPBESS for each basic scenario and the charging and discharging load calculation method of LIPBESS auxiliary regulation.Through optimization using the particle swarm algorithm,the optimal capacity of LIPBESS was determined to be within the 5.24-4.88 MWh range.From an economic perspective,the LIPBESS operating with CFPP as the regulating power source was 49.1% lower in capacity compared to the renewable energy-based storage mode.展开更多
The dual-mode electro-mechanical transmission(EMT)system is a crucial part of power-split hybrid electric vehicles(HEVs),especially for the heavy HEVs.To improve the precision of the system power distribution and the ...The dual-mode electro-mechanical transmission(EMT)system is a crucial part of power-split hybrid electric vehicles(HEVs),especially for the heavy HEVs.To improve the precision of the system power distribution and the response speed of the electric power supply,a model-based double closed-loop coordinated control strategy is proposed.As the basis of the proposed control strategy,an EMT system model,particularly of an electrical system,is established first.The proposed control strategy includes the power distribution strategy,battery power closed-loop feedback control strategy,and motor coordinated control strategy.To verify the feasibility of the proposed control strategy,simulation and experiment are performed.The results indicate that the proposed control strategy can realize the expected power distribution by coordinating generators and motors and achieve rapid and stable electric power supply.展开更多
基金supported by the Natural Science Foundation of China(Grant Nos.52076079,52206010)Natural Science Foundation of Hebei Province,China(Grant No.E2020502013)the Fundamental Research Funds for the Central Universities(2021MS076,2021MS079).
文摘There is a growing need to explore the potential of coal-fired power plants(CFPPs)to enhance the utilization rate of wind power(wind)and photovoltaic power(PV)in the green energy field.This study developed a load regulation model for a multi-power generation system comprising wind,PV,and coal energy storage using realworld data.The power supply process was divided into eight fundamental load regulation scenarios,elucidating the influence of each scenario on load regulation.Within the framework of the multi-power generation system with the wind(50 MW)and PV(50 MW)alongside a CFPP(330 MW),a lithium-iron phosphate energy storage system(LIPBESS)was integrated to improve the system’s load regulation flexibility.The energy storage operation strategy was formulated based on the charging and discharging priority of the LIPBESS for each basic scenario and the charging and discharging load calculation method of LIPBESS auxiliary regulation.Through optimization using the particle swarm algorithm,the optimal capacity of LIPBESS was determined to be within the 5.24-4.88 MWh range.From an economic perspective,the LIPBESS operating with CFPP as the regulating power source was 49.1% lower in capacity compared to the renewable energy-based storage mode.
基金The authors are grateful for the financial support from the National Natural Science Foundation of China(Grant Nos.51705480,No.51575043,Nos.51975048,U1564210,and U1764257).
文摘The dual-mode electro-mechanical transmission(EMT)system is a crucial part of power-split hybrid electric vehicles(HEVs),especially for the heavy HEVs.To improve the precision of the system power distribution and the response speed of the electric power supply,a model-based double closed-loop coordinated control strategy is proposed.As the basis of the proposed control strategy,an EMT system model,particularly of an electrical system,is established first.The proposed control strategy includes the power distribution strategy,battery power closed-loop feedback control strategy,and motor coordinated control strategy.To verify the feasibility of the proposed control strategy,simulation and experiment are performed.The results indicate that the proposed control strategy can realize the expected power distribution by coordinating generators and motors and achieve rapid and stable electric power supply.