The design scheme for a new kind of long-distance intelligent watt-hour meter is presented. In the system, the control computer communicates with the bank's host computer by the X. 25 network; the built-in embeded se...The design scheme for a new kind of long-distance intelligent watt-hour meter is presented. In the system, the control computer communicates with the bank's host computer by the X. 25 network; the built-in embeded secure access module (ESAM) can verify data by commutation with the intelligent nodes that enhance the security of the data. IC TSS721 is adopted to collect data remotely, and the CPU IC card is used to ensure the the bargaining security and reliability. In addition, the software of the system is introduced.展开更多
There is an imperfection in the accuracy indicators system and the technical parameters system in IEC standards 62053-21 implemented for watt-hour meters currently. This article quoted some parts of OIML MI-003 and R4...There is an imperfection in the accuracy indicators system and the technical parameters system in IEC standards 62053-21 implemented for watt-hour meters currently. This article quoted some parts of OIML MI-003 and R46 contents to provide a reference of the integrity comparison between the accuracy system and technical parameter system. The comparison result shows that the watt-hour meter accuracy technical indicators system of OIML R46 is more integrated. First reason is that it determines all the accuracy (basic error) defining rules just by using the technical parameter I efficiently; secondly, it can solve the contradiction that no error regulation of the range from starting current to minimum current in the process of providing, handing over and checking watt-hour meter products' qualities efficiently. Please pay close attention to the R46 official version which will be released soon, as it is still in the Committee Draft (CD6) stage currently.展开更多
文摘The design scheme for a new kind of long-distance intelligent watt-hour meter is presented. In the system, the control computer communicates with the bank's host computer by the X. 25 network; the built-in embeded secure access module (ESAM) can verify data by commutation with the intelligent nodes that enhance the security of the data. IC TSS721 is adopted to collect data remotely, and the CPU IC card is used to ensure the the bargaining security and reliability. In addition, the software of the system is introduced.
文摘There is an imperfection in the accuracy indicators system and the technical parameters system in IEC standards 62053-21 implemented for watt-hour meters currently. This article quoted some parts of OIML MI-003 and R46 contents to provide a reference of the integrity comparison between the accuracy system and technical parameter system. The comparison result shows that the watt-hour meter accuracy technical indicators system of OIML R46 is more integrated. First reason is that it determines all the accuracy (basic error) defining rules just by using the technical parameter I efficiently; secondly, it can solve the contradiction that no error regulation of the range from starting current to minimum current in the process of providing, handing over and checking watt-hour meter products' qualities efficiently. Please pay close attention to the R46 official version which will be released soon, as it is still in the Committee Draft (CD6) stage currently.