Three kinds of methods for processing the data of the multi-wavelength pyrometer are presented in this paper and are named curve auto-search method, curve auto-regression method and neural network method. Tbe experime...Three kinds of methods for processing the data of the multi-wavelength pyrometer are presented in this paper and are named curve auto-search method, curve auto-regression method and neural network method. Tbe experimental results indicate that the calculated temperature and the spectral emissivity compared with the true target temperature and spectral emissivity have significant deviation using the curve auto-search and the curve auto-regression methods. However, the calculated temperature and the spectral emissivity with higher accuracy can be obtained using the neural network method.展开更多
Herein,a method of true-temperature inversion for a multi-wavelength pyrometer based on fractional-order particle-swarm optimization is proposed for difficult inversion problems with unknown emissivity.Fractional-order...Herein,a method of true-temperature inversion for a multi-wavelength pyrometer based on fractional-order particle-swarm optimization is proposed for difficult inversion problems with unknown emissivity.Fractional-order calculus has the inherent advantage of easily jumping out of local extreme values;here,it is introduced into the particle-swarm algorithm to invert the true temperature.An improved adaptive-adjustment mechanism is applied to automatically adjust the current velocity order of the particles and update their velocity and position values,increasing the accuracy of the true temperature values.The results of simulations using the proposed algorithm were compared with three algorithms using typical emissivity models:the internal penalty function algorithm,the optimization function(fmincon)algorithm,and the conventional particle-swarm optimization algorithm.The results show that the proposed algorithm has good accuracy for true-temperature inversion.Actual experimental results from a rocket-motor plume were used to demonstrate that the true-temperature inversion results of this algorithm are in good agreement with the theoretical true-temperature values.展开更多
Conventional microscopes designed for submicron resolution in biological research are hindered by a limited field of view,typically around 1 mm.This restriction poses a challenge when attempting to simultaneously anal...Conventional microscopes designed for submicron resolution in biological research are hindered by a limited field of view,typically around 1 mm.This restriction poses a challenge when attempting to simultaneously analyze various parts of a sample,such as different brain areas.In addition,conventional objective lenses struggle to perform consistently across the required range of wavelengths for brain imaging in vivo.Here we present a novel mesoscopic objective lens with an impressive field of view of 8 mm,a numerical aperture of 0.5,and a working wavelength range from 400 to 1000 nm.We achieved a resolution of 0.74μm in fluorescent beads imaging.The versatility of this lens was further demonstrated through high-quality images of mouse brain and kidney sections in a wide-field imaging system,a confocal laser scanning system,and a two-photon imaging system.This mesoscopic objective lens holds immense promise for advancing multi-wavelength imaging of large fields of view at high resolution.展开更多
To control drug effects by detecting temperature difference between biologically active point(BAP)and intact area of skin for treatment of mental illness,a device is developed for monitoring the temperature of BAP a...To control drug effects by detecting temperature difference between biologically active point(BAP)and intact area of skin for treatment of mental illness,a device is developed for monitoring the temperature of BAP and the dose medication and its change in real time to increase effectiveness of treatment.Two electrodes by Foll R method are used and BAP is determined based on topographic anatomical reference points.The temperature values are measured by integral thermometers DS18B20.the received data are processed and temperature difference is calculated and displayed under the control of microcontroller Atmega32.The obtained data confirm the correlation between the temperature difference indicators BAP C7,Gi4 and neurological scales assessing severity of mental illness.The experimetal results show that the temperature difference can be criteria for evaluating the effects of drugs,which is the basis for computer control systems of of medical process of mental patients.展开更多
The recently discovered Damoqujia (大磨曲家) gold deposit is a large shear zone-hosted gold deposit of disseminated sulphides located in the north of the Zhaoping (招平) fault zone, Jiaodong (胶东) gold province...The recently discovered Damoqujia (大磨曲家) gold deposit is a large shear zone-hosted gold deposit of disseminated sulphides located in the north of the Zhaoping (招平) fault zone, Jiaodong (胶东) gold province, China. In order to distinguish the temperature range of cluster inclusions from different mineralization stages and measure their compositions, 16 fluid inclusions and 5 isotopic geochemistry samples were collected for this study. Corresponding to different mineralization stages, the multirange peaks of quartz decrepitation temperature (250-270, 310-360 and 380-430℃) indicate that the activity of ore-forming fluids is characterized by multistage. The ore-forming fluids were predominantly of high-temperature fluid system (HTFS) by CO2-rich, and SO4^2--K^+ type magmatic fluid during the early stage of mineralization and were subsequently affected by low-temperature fluid system (LTFS) of CH4-rich, and Cl^--Na^+/Ca^2+ type meteoric fluid during the late stage of mineralization. Gold is transferred by Au-HS^- complex in the HTFS, and Au-Cl^- complex can be more important in the LTFS. The transition of fluids from deeper to shallow environments results in mixing between the HTFS and LTFS, which might be one of the most key reasons for gold precipitation and large-scale mineralization. The ore-forming fluids are characterized by high-temperature, strong-activity, and superimposed mineralization, so that there is a great probability of forming large and rich ore deposit in the Damoqujia gold deposit. The main bodies are preserved and extend toward deeper parts, thereby suggesting a great potential in future.展开更多
In general, the dependence of the logarithm of the emissivity upon wavelength is usually used in the treatment of data measured by multi-wavelength pyrometer. In this paper, the suitability of this expression for diff...In general, the dependence of the logarithm of the emissivity upon wavelength is usually used in the treatment of data measured by multi-wavelength pyrometer. In this paper, the suitability of this expression for different materials has been examined. Further more, an effective method for automatically searching the mathematical model between emissivity and wavelength has been procsed. The calculated results show that the accuracy is improved by using this data treatment method.展开更多
The effect of arc on radiation thermometry is analyzed in a field close to the arc during the welding process, and the ratio of signal to noise and other factors are obtained for a small current arc .The method of the...The effect of arc on radiation thermometry is analyzed in a field close to the arc during the welding process, and the ratio of signal to noise and other factors are obtained for a small current arc .The method of the temperature measurement is feasible when the arc current is decreased to a smaller value in the welding process.展开更多
In order to overcome the effect of the assumption between emissivity and wavelength on the measurement of true temperature and spectral emissivity for most engineering materials, a neural network based method is propo...In order to overcome the effect of the assumption between emissivity and wavelength on the measurement of true temperature and spectral emissivity for most engineering materials, a neural network based method is proposed for data processing while a blackbody furnace and three optical filters with known spectral transmittance curves were used to make up a true target. The experimental results show that the calculated temperatures are in good agreement with the temperature of the blackbody furnace, and the calculated spectral emissivity curves are in good agreement with the spectral transmittance curves of the filters. The method proposed has been proved to be an effective method for solving the problem of true temperature and emissivity measurement, and it can overcome the effect of the assumption between emissivity and wavelength on the measurement of true temperature and spectral emissivity for most engineering materials.展开更多
We report on a study of terahertz(THz) generation using implanted In Ga As photomixers and multi-wavelength quantum dot lasers. We carry out In Ga As materials growth, optical characterization, device design and fabri...We report on a study of terahertz(THz) generation using implanted In Ga As photomixers and multi-wavelength quantum dot lasers. We carry out In Ga As materials growth, optical characterization, device design and fabrication, and photomixing experiments. This approach is capable of generating a comb of electromagnetic radiation from microwave to terahertz. For shortening photomixer carrier lifetime, we employ proton implantation into an epitaxial layer of lattice matched In Ga As grown on InP. Under a 1.55 μm multimode In GaAs/In GaAsP quantum dot laser excitation, a frequency comb with a constant frequency spacing of 50 GHz generated on the photomixer is measured, which corresponds to the beats of the laser longitudinal modes. The measurement is performed with a Fourier transform infrared spectrometer. This approach affords a convenient method to achieve a broadband multi-peak coherent THz source.展开更多
Multi-wavelength continuous-wave self-Raman laser with an a-cut composite YVO4/Nd:YVO4/YVO4 crystal pumped by an 879-nm wavelength-locked laser diode is demonstrated for the first time.Multi-wavelength Raman lasers at...Multi-wavelength continuous-wave self-Raman laser with an a-cut composite YVO4/Nd:YVO4/YVO4 crystal pumped by an 879-nm wavelength-locked laser diode is demonstrated for the first time.Multi-wavelength Raman lasers at 1168.4,1176,1178.7,and 1201.6 nm are achieved by the first Stokes shift of the multi-wavelength fundamental lasers at 1064,1066.7,1073.6,1084,and 1085.6 nm with two Raman shifts of 890 and 816 cm^-1.A maximum Raman output power of 2.56 W is achieved through the use of a 20-mm-long composite crystal,with a corresponding optical conversion efficiency of 9.8%.The polarization directions of different fundamental and Raman lasers are investigated and found to be orthogonalπandσpolarizations.These orthogonally polarized multi-wavelength lasers with small wavelength separation pave the way to the development of a potential laser source for application in spectral analysis,laser radar and THz generation.展开更多
The present study deals with the possibilities of applying the zircon saturation thermometry, which is based on the equilibrium between the zircon crystals and the melt, to strongly altered volcanic ashes—bentonites....The present study deals with the possibilities of applying the zircon saturation thermometry, which is based on the equilibrium between the zircon crystals and the melt, to strongly altered volcanic ashes—bentonites. It proposes an alternative to a widely used method of calculating magma temperature from Zr content and major component composition(Boehnke in Chem Geol351:324–333, 2013), that is not suitable for bentonites, as most of the major components have been largely altered in these rocks. For calculating source magma temperatures in strongly altered volcanic ashes, the exponential function from the Zr(ppm)/Al_(2)O_(3)(%) ratio with compositional corrections from the TiO_(2)/Al_(2)O_(3) ratio was found applicable. The idea to use the ratios of these elements is based on the low mobility of these elements in the earth’s surface conditions. Temperatures of magma, forming in the partial melting process, are assessed from the bulk rock composition. Pre-eruption temperatures were estimated from the composition of fine fractions of bentonites. The accuracy of the new method was established from comparison with the method by Boehnke et al.(Chem Geol 351:324–333,2013). The difference between the two methods was mostly less than ± 30° to ± 50°. The comparison with the magma temperature, estimated from the sanidine composition,revealed 13° lower values on average. Although the proposed method for estimating the source magma temperatures is less precise than the method of accounting for detailed rock compositions, it can be used in strongly altered rocks, where other methods are not usable. The new method still enables differentiation between felsic source magmas originating at low or high temperatures. Early Palaeozoic bentonites in the Baltic Basin can be divided,according to the source magma temperatures, into two types:(1) Low temperature(650–790 ℃), containing potassium-rich sanidine and abundant biotite(S type),(2)high temperature(770–850 ℃) with sodium-rich sanidine and scarce biotite(I type).展开更多
This investigation developed a new method for determining metal complex's property containing the stepwise real absorptivity(epsilon) and stability constant (K-m). The correction equation of the multi-wavelength s...This investigation developed a new method for determining metal complex's property containing the stepwise real absorptivity(epsilon) and stability constant (K-m). The correction equation of the multi-wavelength spectral absorption was established for the simultaneous determination of various complexes to give high accuracy for trace analysis. This method was more acceptable in theory and simpler in operation than the classical methods.展开更多
A method for measurement of ultra-low flying height in head-disk spacing is described. Three different wavelengths are selected out from white light by filters to measure the spacing simultaneously. Besides solving th...A method for measurement of ultra-low flying height in head-disk spacing is described. Three different wavelengths are selected out from white light by filters to measure the spacing simultaneously. Besides solving the ambiguity problem, a more reliable result is achieved by using weighted average of measurement results from three different wavelengths, where the weight is dependent upon spacing. Fringe-bunching correction algorithm (FBC) and spot-tilling technique are adopted to suppress calibration and random errors. Moreover, incident bandwidth correction (IBC) method is introduced to compensate the error caused by low monochromaticity of incident light. Based on dynamic flying height tester (DFHT Ⅱ), with the redesigned of photo-electric conversion and signal acquirement module, an instrument has been developed. And comparing the experimental data from the instrument with those from a KLA-FHT D6, the discrepancy is less than 5%. It indicates that the instrument is suitable to perform ultra-low flying height measurement and satisfies the reauirement of magnetic heads manufacturing.展开更多
A method of measuring turbidity based on a multi-wavelength spectral sensor is proposed by using SFH4737 broad-band infrared LED,a multi-wavelength spectral sensor and independently developed data processing software....A method of measuring turbidity based on a multi-wavelength spectral sensor is proposed by using SFH4737 broad-band infrared LED,a multi-wavelength spectral sensor and independently developed data processing software.Combining multiple wavelength data from the sensor,the unitary and multivariate fitting models were constructed to investigate the relationship among light intensity information,absorbance and turbidity,respectively.The turbidity of the actual water bodies was measured separately by using proposed method and a commercially visible spectrophotometer.The independent-samples T test(p>0.05)showed that there was no significant difference between the method in this paper and the standard assay method.The method is simple and inexpensive,and can be applied to the rapid detection of water turbidity,providing a new way of industrial online measurement.展开更多
A seed laser oscillating at different frequencies is proved to have the potential to mitigate the stimulated Brillouin scattering(SBS) effect in a fiber amplifier,which may increase the emission power of a coherent ...A seed laser oscillating at different frequencies is proved to have the potential to mitigate the stimulated Brillouin scattering(SBS) effect in a fiber amplifier,which may increase the emission power of a coherent beam combination(CBC) system greatly.In this study,a basic mathematical model describing the multi-wavelength CBC is proposed on the fundamentals of CBC.A useful method for estimating the combination effect and analysing the feasibility and the validity of the multi-wavelength coherent combination is provided.In the numerical analysis,accordant results with four-wavelength four-channel CBC experiments are obtained.Through calculations of some examples with certain spectra,the unanticipated excellent combination effect with a few frequencies involved is explained,and the dependence of the combination effect on the variance of the amplifier chain length and the channel number is clarified.展开更多
Thermal ablation procedures,such as high intensity focused ultrasound and radiofrequency ablation,are often used to eliminate tumors by minimally invasively heating a focal region.For this task,real-time 3D temperatur...Thermal ablation procedures,such as high intensity focused ultrasound and radiofrequency ablation,are often used to eliminate tumors by minimally invasively heating a focal region.For this task,real-time 3D temperature visualization is key to target the diseased tissues while minimizing damage to the surroundings.Current computed tomography(CT)thermometry is based on energy-integrated CT,tissue-specific experimental data,and linear relationships between attenuation and temperature.In this paper,we develop a novel approach using photon-counting CT for material decomposition and a neural network to predict temperature based on thermal characteristics of base materials and spectral tomographic measurements of a volume of interest.In our feasibility study,distilled water,50 mmol/L CaCl2,and 600 mmol/L CaCl2 are chosen as the base materials.Their attenuations are measured in four discrete energy bins at various temperatures.The neural network trained on the experimental data achieves a mean absolute error of 3.97°C and 1.80°C on 300 mmol/L CaCl2 and a milk-based protein shake respectively.These experimental results indicate that our approach is promising for handling non-linear thermal properties for materials that are similar or dis-similar to our base materials.展开更多
The purpose of the study was to investigate if the high gradient strength and slew rate used for long MRI-thermometry monitoring could cause DNA double-stranded breaks (DSBs). To this end, an enzyme-linked immunosorbe...The purpose of the study was to investigate if the high gradient strength and slew rate used for long MRI-thermometry monitoring could cause DNA double-stranded breaks (DSBs). To this end, an enzyme-linked immunosorbent assay (ELISA) was used to quantify γH2AX, a molecular marker for DSBs, in the blood of mice after a 6-hour exposure to magnetic resonance imaging (MRI). Fourteen CF-1 female mice were separated into 4 experimental groups: Untreated negative control, MRI-treated, MRI-Control, and exposed to ionizing radiation positive control. Untreated negative control was used as a baseline for ELISA to quantify γH2AX. MRI-treated consisted of a 6-hour continuous magnetic resonance imaging (MRI) echo planar imaging (EPI) sequence with a slew rate of 192 mT/m/s constituting a significantly longer imaging time than routine clinical imaging. MRI-control mice were maintained under the same conditions outside the MRI scanner for 6-hours. Mice in the irradiation group served as a positive control of DSBs and were exposed to either 2 Gy, 5 Gy or 10 Gy of ionizing radiation. DSBs in the blood lymphocytes from the treatment groups were analyzed using the γH2AX ELISA and compared. Total protein concentration in lysates was determined for each blood sample and averaged 1 ± 0.35 mg/mL. Irradiated positive controls were used to test radiation dose-dependency of the γH2AX ELISA assay where a linear dependency on radiation exposure was observed (r<sup>2</sup> = 0.93) between untreated and irradiated samples. Mean and standard error mean of γH2AX formation were calculated and compared between each treatment group. Repeated measures 1-way ANOVA showed statistically significant differences between the means of irradiated controls and both the MRI-control and MRI-treated groups. There was no statistically significant difference between the MRI-treated samples and the MRI-control groups. Our results show that long MRI exposure at a high slew rate did not cause increased levels of γH2AX when compared to control mice, suggesting that no increase in DSBs was caused by the long MR thermometry imaging session. The novelty of this work contradicts other studies that have suggested MRI may cause DSBs;this work suggests an alternative cause of DNA damage.展开更多
基金Sponsored by the National Natural Science Foundation of China(Grant No. 60377037)the Scientific Research Foundation of Harbin Institute of Technol-ogy (Grant No. HIT. 2002. 18)the Spaceflight Support Foundation.
文摘Three kinds of methods for processing the data of the multi-wavelength pyrometer are presented in this paper and are named curve auto-search method, curve auto-regression method and neural network method. Tbe experimental results indicate that the calculated temperature and the spectral emissivity compared with the true target temperature and spectral emissivity have significant deviation using the curve auto-search and the curve auto-regression methods. However, the calculated temperature and the spectral emissivity with higher accuracy can be obtained using the neural network method.
基金supported by the National Natural Science Foundation of China(Grant No.62205280)the Graduate Innovation Foundation of Yantai University(Grant No.GGIFYTU2348).
文摘Herein,a method of true-temperature inversion for a multi-wavelength pyrometer based on fractional-order particle-swarm optimization is proposed for difficult inversion problems with unknown emissivity.Fractional-order calculus has the inherent advantage of easily jumping out of local extreme values;here,it is introduced into the particle-swarm algorithm to invert the true temperature.An improved adaptive-adjustment mechanism is applied to automatically adjust the current velocity order of the particles and update their velocity and position values,increasing the accuracy of the true temperature values.The results of simulations using the proposed algorithm were compared with three algorithms using typical emissivity models:the internal penalty function algorithm,the optimization function(fmincon)algorithm,and the conventional particle-swarm optimization algorithm.The results show that the proposed algorithm has good accuracy for true-temperature inversion.Actual experimental results from a rocket-motor plume were used to demonstrate that the true-temperature inversion results of this algorithm are in good agreement with the theoretical true-temperature values.
基金supported by National Key R&D Program of China(grant no.2022YFC2404201)the Chinese Academy of Sciences Project for Young Scientists in Basic Research(grant no.YSBR067).
文摘Conventional microscopes designed for submicron resolution in biological research are hindered by a limited field of view,typically around 1 mm.This restriction poses a challenge when attempting to simultaneously analyze various parts of a sample,such as different brain areas.In addition,conventional objective lenses struggle to perform consistently across the required range of wavelengths for brain imaging in vivo.Here we present a novel mesoscopic objective lens with an impressive field of view of 8 mm,a numerical aperture of 0.5,and a working wavelength range from 400 to 1000 nm.We achieved a resolution of 0.74μm in fluorescent beads imaging.The versatility of this lens was further demonstrated through high-quality images of mouse brain and kidney sections in a wide-field imaging system,a confocal laser scanning system,and a two-photon imaging system.This mesoscopic objective lens holds immense promise for advancing multi-wavelength imaging of large fields of view at high resolution.
文摘To control drug effects by detecting temperature difference between biologically active point(BAP)and intact area of skin for treatment of mental illness,a device is developed for monitoring the temperature of BAP and the dose medication and its change in real time to increase effectiveness of treatment.Two electrodes by Foll R method are used and BAP is determined based on topographic anatomical reference points.The temperature values are measured by integral thermometers DS18B20.the received data are processed and temperature difference is calculated and displayed under the control of microcontroller Atmega32.The obtained data confirm the correlation between the temperature difference indicators BAP C7,Gi4 and neurological scales assessing severity of mental illness.The experimetal results show that the temperature difference can be criteria for evaluating the effects of drugs,which is the basis for computer control systems of of medical process of mental patients.
基金supported by the National Natural Science Foundation of China (Nos. 40672064, 40572063)the 973-Project (No. 2006CB403506)Changjiang Scholars and Innovative Research Team in University and 111 Project of the Ministry of Education, China (No. B07011)
文摘The recently discovered Damoqujia (大磨曲家) gold deposit is a large shear zone-hosted gold deposit of disseminated sulphides located in the north of the Zhaoping (招平) fault zone, Jiaodong (胶东) gold province, China. In order to distinguish the temperature range of cluster inclusions from different mineralization stages and measure their compositions, 16 fluid inclusions and 5 isotopic geochemistry samples were collected for this study. Corresponding to different mineralization stages, the multirange peaks of quartz decrepitation temperature (250-270, 310-360 and 380-430℃) indicate that the activity of ore-forming fluids is characterized by multistage. The ore-forming fluids were predominantly of high-temperature fluid system (HTFS) by CO2-rich, and SO4^2--K^+ type magmatic fluid during the early stage of mineralization and were subsequently affected by low-temperature fluid system (LTFS) of CH4-rich, and Cl^--Na^+/Ca^2+ type meteoric fluid during the late stage of mineralization. Gold is transferred by Au-HS^- complex in the HTFS, and Au-Cl^- complex can be more important in the LTFS. The transition of fluids from deeper to shallow environments results in mixing between the HTFS and LTFS, which might be one of the most key reasons for gold precipitation and large-scale mineralization. The ore-forming fluids are characterized by high-temperature, strong-activity, and superimposed mineralization, so that there is a great probability of forming large and rich ore deposit in the Damoqujia gold deposit. The main bodies are preserved and extend toward deeper parts, thereby suggesting a great potential in future.
文摘In general, the dependence of the logarithm of the emissivity upon wavelength is usually used in the treatment of data measured by multi-wavelength pyrometer. In this paper, the suitability of this expression for different materials has been examined. Further more, an effective method for automatically searching the mathematical model between emissivity and wavelength has been procsed. The calculated results show that the accuracy is improved by using this data treatment method.
文摘The effect of arc on radiation thermometry is analyzed in a field close to the arc during the welding process, and the ratio of signal to noise and other factors are obtained for a small current arc .The method of the temperature measurement is feasible when the arc current is decreased to a smaller value in the welding process.
文摘In order to overcome the effect of the assumption between emissivity and wavelength on the measurement of true temperature and spectral emissivity for most engineering materials, a neural network based method is proposed for data processing while a blackbody furnace and three optical filters with known spectral transmittance curves were used to make up a true target. The experimental results show that the calculated temperatures are in good agreement with the temperature of the blackbody furnace, and the calculated spectral emissivity curves are in good agreement with the spectral transmittance curves of the filters. The method proposed has been proved to be an effective method for solving the problem of true temperature and emissivity measurement, and it can overcome the effect of the assumption between emissivity and wavelength on the measurement of true temperature and spectral emissivity for most engineering materials.
基金supported in part by NSERC. HCL thanks the support by the National Ma jor Basic Research Pro jects (2011CB925603)Shanghai Municipal Ma jor Basic Research Pro ject (09DJ1400102)
文摘We report on a study of terahertz(THz) generation using implanted In Ga As photomixers and multi-wavelength quantum dot lasers. We carry out In Ga As materials growth, optical characterization, device design and fabrication, and photomixing experiments. This approach is capable of generating a comb of electromagnetic radiation from microwave to terahertz. For shortening photomixer carrier lifetime, we employ proton implantation into an epitaxial layer of lattice matched In Ga As grown on InP. Under a 1.55 μm multimode In GaAs/In GaAsP quantum dot laser excitation, a frequency comb with a constant frequency spacing of 50 GHz generated on the photomixer is measured, which corresponds to the beats of the laser longitudinal modes. The measurement is performed with a Fourier transform infrared spectrometer. This approach affords a convenient method to achieve a broadband multi-peak coherent THz source.
基金Project supported by the National Natural Science Foundation of China(Grant No.11774301)the Young Scientists Fund of the National Natural Science Foundation of China(Grant No.11804292)
文摘Multi-wavelength continuous-wave self-Raman laser with an a-cut composite YVO4/Nd:YVO4/YVO4 crystal pumped by an 879-nm wavelength-locked laser diode is demonstrated for the first time.Multi-wavelength Raman lasers at 1168.4,1176,1178.7,and 1201.6 nm are achieved by the first Stokes shift of the multi-wavelength fundamental lasers at 1064,1066.7,1073.6,1084,and 1085.6 nm with two Raman shifts of 890 and 816 cm^-1.A maximum Raman output power of 2.56 W is achieved through the use of a 20-mm-long composite crystal,with a corresponding optical conversion efficiency of 9.8%.The polarization directions of different fundamental and Raman lasers are investigated and found to be orthogonalπandσpolarizations.These orthogonally polarized multi-wavelength lasers with small wavelength separation pave the way to the development of a potential laser source for application in spectral analysis,laser radar and THz generation.
文摘The present study deals with the possibilities of applying the zircon saturation thermometry, which is based on the equilibrium between the zircon crystals and the melt, to strongly altered volcanic ashes—bentonites. It proposes an alternative to a widely used method of calculating magma temperature from Zr content and major component composition(Boehnke in Chem Geol351:324–333, 2013), that is not suitable for bentonites, as most of the major components have been largely altered in these rocks. For calculating source magma temperatures in strongly altered volcanic ashes, the exponential function from the Zr(ppm)/Al_(2)O_(3)(%) ratio with compositional corrections from the TiO_(2)/Al_(2)O_(3) ratio was found applicable. The idea to use the ratios of these elements is based on the low mobility of these elements in the earth’s surface conditions. Temperatures of magma, forming in the partial melting process, are assessed from the bulk rock composition. Pre-eruption temperatures were estimated from the composition of fine fractions of bentonites. The accuracy of the new method was established from comparison with the method by Boehnke et al.(Chem Geol 351:324–333,2013). The difference between the two methods was mostly less than ± 30° to ± 50°. The comparison with the magma temperature, estimated from the sanidine composition,revealed 13° lower values on average. Although the proposed method for estimating the source magma temperatures is less precise than the method of accounting for detailed rock compositions, it can be used in strongly altered rocks, where other methods are not usable. The new method still enables differentiation between felsic source magmas originating at low or high temperatures. Early Palaeozoic bentonites in the Baltic Basin can be divided,according to the source magma temperatures, into two types:(1) Low temperature(650–790 ℃), containing potassium-rich sanidine and abundant biotite(S type),(2)high temperature(770–850 ℃) with sodium-rich sanidine and scarce biotite(I type).
基金the Natural Science Foundation of Anhui Province (No. 99045332)
文摘This investigation developed a new method for determining metal complex's property containing the stepwise real absorptivity(epsilon) and stability constant (K-m). The correction equation of the multi-wavelength spectral absorption was established for the simultaneous determination of various complexes to give high accuracy for trace analysis. This method was more acceptable in theory and simpler in operation than the classical methods.
基金National Basic Research Program of China(973 Program,No. 2003CB716207)National Natural Science Foundation of China(No.50775091)
文摘A method for measurement of ultra-low flying height in head-disk spacing is described. Three different wavelengths are selected out from white light by filters to measure the spacing simultaneously. Besides solving the ambiguity problem, a more reliable result is achieved by using weighted average of measurement results from three different wavelengths, where the weight is dependent upon spacing. Fringe-bunching correction algorithm (FBC) and spot-tilling technique are adopted to suppress calibration and random errors. Moreover, incident bandwidth correction (IBC) method is introduced to compensate the error caused by low monochromaticity of incident light. Based on dynamic flying height tester (DFHT Ⅱ), with the redesigned of photo-electric conversion and signal acquirement module, an instrument has been developed. And comparing the experimental data from the instrument with those from a KLA-FHT D6, the discrepancy is less than 5%. It indicates that the instrument is suitable to perform ultra-low flying height measurement and satisfies the reauirement of magnetic heads manufacturing.
基金National Natural Science Foundation of China(No.71801108)Natural Science Fund for Colleges and Universities of Anhui Province(No.KJ2017ZD32)。
文摘A method of measuring turbidity based on a multi-wavelength spectral sensor is proposed by using SFH4737 broad-band infrared LED,a multi-wavelength spectral sensor and independently developed data processing software.Combining multiple wavelength data from the sensor,the unitary and multivariate fitting models were constructed to investigate the relationship among light intensity information,absorbance and turbidity,respectively.The turbidity of the actual water bodies was measured separately by using proposed method and a commercially visible spectrophotometer.The independent-samples T test(p>0.05)showed that there was no significant difference between the method in this paper and the standard assay method.The method is simple and inexpensive,and can be applied to the rapid detection of water turbidity,providing a new way of industrial online measurement.
基金Project supported by the Innovation Foundation for Postgraduates in the National University of Defense Technology,China(Grant No. S090701)
文摘A seed laser oscillating at different frequencies is proved to have the potential to mitigate the stimulated Brillouin scattering(SBS) effect in a fiber amplifier,which may increase the emission power of a coherent beam combination(CBC) system greatly.In this study,a basic mathematical model describing the multi-wavelength CBC is proposed on the fundamentals of CBC.A useful method for estimating the combination effect and analysing the feasibility and the validity of the multi-wavelength coherent combination is provided.In the numerical analysis,accordant results with four-wavelength four-channel CBC experiments are obtained.Through calculations of some examples with certain spectra,the unanticipated excellent combination effect with a few frequencies involved is explained,and the dependence of the combination effect on the variance of the amplifier chain length and the channel number is clarified.
基金the Johns Hopkins University Leong Research Award for Undergraduates.
文摘Thermal ablation procedures,such as high intensity focused ultrasound and radiofrequency ablation,are often used to eliminate tumors by minimally invasively heating a focal region.For this task,real-time 3D temperature visualization is key to target the diseased tissues while minimizing damage to the surroundings.Current computed tomography(CT)thermometry is based on energy-integrated CT,tissue-specific experimental data,and linear relationships between attenuation and temperature.In this paper,we develop a novel approach using photon-counting CT for material decomposition and a neural network to predict temperature based on thermal characteristics of base materials and spectral tomographic measurements of a volume of interest.In our feasibility study,distilled water,50 mmol/L CaCl2,and 600 mmol/L CaCl2 are chosen as the base materials.Their attenuations are measured in four discrete energy bins at various temperatures.The neural network trained on the experimental data achieves a mean absolute error of 3.97°C and 1.80°C on 300 mmol/L CaCl2 and a milk-based protein shake respectively.These experimental results indicate that our approach is promising for handling non-linear thermal properties for materials that are similar or dis-similar to our base materials.
文摘The purpose of the study was to investigate if the high gradient strength and slew rate used for long MRI-thermometry monitoring could cause DNA double-stranded breaks (DSBs). To this end, an enzyme-linked immunosorbent assay (ELISA) was used to quantify γH2AX, a molecular marker for DSBs, in the blood of mice after a 6-hour exposure to magnetic resonance imaging (MRI). Fourteen CF-1 female mice were separated into 4 experimental groups: Untreated negative control, MRI-treated, MRI-Control, and exposed to ionizing radiation positive control. Untreated negative control was used as a baseline for ELISA to quantify γH2AX. MRI-treated consisted of a 6-hour continuous magnetic resonance imaging (MRI) echo planar imaging (EPI) sequence with a slew rate of 192 mT/m/s constituting a significantly longer imaging time than routine clinical imaging. MRI-control mice were maintained under the same conditions outside the MRI scanner for 6-hours. Mice in the irradiation group served as a positive control of DSBs and were exposed to either 2 Gy, 5 Gy or 10 Gy of ionizing radiation. DSBs in the blood lymphocytes from the treatment groups were analyzed using the γH2AX ELISA and compared. Total protein concentration in lysates was determined for each blood sample and averaged 1 ± 0.35 mg/mL. Irradiated positive controls were used to test radiation dose-dependency of the γH2AX ELISA assay where a linear dependency on radiation exposure was observed (r<sup>2</sup> = 0.93) between untreated and irradiated samples. Mean and standard error mean of γH2AX formation were calculated and compared between each treatment group. Repeated measures 1-way ANOVA showed statistically significant differences between the means of irradiated controls and both the MRI-control and MRI-treated groups. There was no statistically significant difference between the MRI-treated samples and the MRI-control groups. Our results show that long MRI exposure at a high slew rate did not cause increased levels of γH2AX when compared to control mice, suggesting that no increase in DSBs was caused by the long MR thermometry imaging session. The novelty of this work contradicts other studies that have suggested MRI may cause DSBs;this work suggests an alternative cause of DNA damage.