期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Multianalyte Biosensors for the Simultaneous Determination of Glucose and Galactose Based on Thin Film Electrodes
1
作者 NengQinJIA ZongRangZHANG +1 位作者 JiangZhongZHU GuoXiongZHANG 《Chinese Chemical Letters》 SCIE CAS CSCD 2004年第3期322-325,共4页
A multianalyte biosensor for the simultaneous determination of glucose and galactose was developed by immobilizing glucose oxidase (GOD) and galactose oxidase (GAO) on Nafion-modified thin film platinum disk electrod... A multianalyte biosensor for the simultaneous determination of glucose and galactose was developed by immobilizing glucose oxidase (GOD) and galactose oxidase (GAO) on Nafion-modified thin film platinum disk electrodes. The dual Pt working electrodes with disk shape and the surrounding ring shaped counter electrode were fabricated by thin film technology, which were integrated onto the same microchip. The response of the designed biosensor for glucose and galactose were linear up to 6.0 mmol/L and 3.5 mmol/L with sensitivities of 0.3 mA/mmol/L and 0.12 mA/mmol/L, respectively. No cross-talking effect was observed. 展开更多
关键词 multianalyte biosensor glucoe GALACTOSE NAFION thin film technology.
下载PDF
Multianalyte Biosensor for Simultaneous Determination of Glucose and Galactose Based on Micromachined Chamber-type Electrodes
2
作者 贾能勤 章宗穰 +1 位作者 朱建中 张国雄 《Chinese Journal of Chemistry》 SCIE CAS CSCD 2004年第9期908-912,共5页
An amperometric multianalyte biosensor for the simultaneous determination of glucose and galactose was de-veloped based on chamber-type electrodes, which were fabricated by micromachining technology. The dual cham-ber... An amperometric multianalyte biosensor for the simultaneous determination of glucose and galactose was de-veloped based on chamber-type electrodes, which were fabricated by micromachining technology. The dual cham-ber-type enzyme electrode with glucose and galactose sensor elements was integrated onto one microchip. The ex-perimental parameters of this biosensor were optimized. The biosensor exhibited a linearity of up to 4.0 mol/L for glucose and 4.5 mol/L for galactose, and the response time was about 30 s for glucose and 40 s for galactose. No cross-talking behavior was investigated in the course of simultaneous measurement of the two analytes. Interference from electroactive species, such as ascorbic acid and uric acid, was minimized due to the permselectivity of Nafion film. In addition, the biosensor displayed a storage stability of longer than one month. 展开更多
关键词 multianalyte biosensor micromachining technology chamber-type electrode
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部