[Objective]The activities of urease and phosphatase in integrated vertical flow constructed wetland and purification effect of black and malodorous river were studied.[Method]Honeycomb stone and soft filler were used ...[Objective]The activities of urease and phosphatase in integrated vertical flow constructed wetland and purification effect of black and malodorous river were studied.[Method]Honeycomb stone and soft filler were used as matrix,the biological grid integrated vertical flow constructed wetland system was built to strengthen treatment for black and malodorous river,and the activities of urease and phosphatase of two fillers in different functional areas of constructed wetland were tested to study the film formation property of two fillers in different functional areas.[Result]Both urease and phosphatase activities on biofilm of soft filler were significantly higher than on biofilm of honeycomb stone filler;indicating that choosing soft filler was more advantageous to the growth of biofilm;and urease activity had significant correlation with total nitrogen removal rate,while phosphatase activity had no significant correlation with total phosphorus removal rate.[Conclusion]This study provided evidences for utilizing the activities of urease and phosphatase to evaluate the purification effect of black and malodorous river and choose appropriate filler.展开更多
[Objective] The aim was to al eviate the constructed wetland clogging problems and to explore to the effects of hydraulic loading on wetland clogging. [Method] The experiment, through artificial soil columns, simulate...[Objective] The aim was to al eviate the constructed wetland clogging problems and to explore to the effects of hydraulic loading on wetland clogging. [Method] The experiment, through artificial soil columns, simulated vertical flow arti-ficial wetland, set four hydraulic load level at 50, 100, 150 and 200 cm/d, to identify the impact of hydraulic loading on wetland clogging and to explore the factors run-ning threshold. [Result] The results show that the different levels of hydraulic loading have greater impact; in the constructed wetland clogging process under high hy-draulic loading of 200 cm/d, the effective life was only six months, and the single factor can be speculated that the threshold of the hydraulic load should be at 100-150 cm/d; system can last for six months at low hydraulic loading and last for three months at medium hydraulic load. [Conclusion] The research provides references for wetland clogging experiments in future.展开更多
This research explores strategies to enhance the efficiency of secondary treatment in Vertical Flow Constructed Wetlands (CW) in Montenegro. The focus is on selecting appropriate primary treatment methods alongside th...This research explores strategies to enhance the efficiency of secondary treatment in Vertical Flow Constructed Wetlands (CW) in Montenegro. The focus is on selecting appropriate primary treatment methods alongside three distinct substrate types to improve wastewater treatment efficacy. The study examines the combination of two primary treatments with different substrate types in constructed wetlands (CW1, CW2, and CW3). The primary treatments include the existing wastewater treatment plant (WWTP) in Podgorica, involving coarse material removal through screens, inert material separation in aerated sand traps, and sediment and suspended matter removal in primary sedimentation tanks. The Extreme Separator (ExSep) was employed to evaluate its efficacy as a primary treatment method. The research demonstrates that the efficiency of CW can be significantly enhanced by selecting suitable primary treatment methods and substrates in Podgorica’s conditions. The most promising results were achieved by combining ExSep as a primary treatment with secondary treatment in CW-3. The removal efficiencies after CW3 for COD, BOD, and TSS exceeded 89%, 93%, and 91%, respectively. The outcomes underscore the significance of primary treatment in mitigating pollutant loads before discharge into the constructed wetlands, emphasizing potential areas for further optimization in wastewater treatment practices to enhance environmental sustainability and water quality management.展开更多
The operational performance of a full scale subsurface flow constructed wetland, which treated the mixed industrial and domestic wastewater with BOD 5/COD mean ratio of 0 33 at Shatian, Shenzhen City was studied. ...The operational performance of a full scale subsurface flow constructed wetland, which treated the mixed industrial and domestic wastewater with BOD 5/COD mean ratio of 0 33 at Shatian, Shenzhen City was studied. The constructed wetland system consists of screens, sump, pumping station, and primary settling basin, facultative pond, first stage wetland and secondary stage wetland. The designed treatment capacity is 5000 m 3/d, and the actual influent flow is in the range of <2000 to >10000 m 3/d. Under normal operational conditions, the final effluent quality well met the National Integrated Wastewater Discharge Standard(GB 8978\_1996), with the following parameters(mean values): COD 33 90 mg/L, BOD 5 7.65 mg/L, TSS 7.92 mg/L, TN 9.11 mg/L and TP 0 56 mg/L. Seven species of plants were selected to grow in the wetland: Reed, Sweetcane flower Silvergrass, Great Bulrush, Powdery Thalia and Canna of three colours. The growing season is a whole year round. The seasonal discrepancy could be observed and the plants growing in the wetland are vulnerable to lower temperature in winter. The recycling of the effluent in the first stage of the wetland system is an effective measure to improve the performance of the wetland system. The insufficient DO value in the wetland system not only had significant effect on pollutants removal in the wetland, but also was unfavourable to plant growth. The recycling of effluent to the inlet of wetland system and artificial pond to increase DO value of influent to the wetland is key to operate the subsurface constructed wetland steadily and effectively.展开更多
Vertical flow constructed wetlands is a typical ecological sanitation system for sewage treatment. The removal rates for COD, BOD 5, SS, TN, and TP were 60%, 80%, 74%, 49% and 79%, respectively, when septic tank effl...Vertical flow constructed wetlands is a typical ecological sanitation system for sewage treatment. The removal rates for COD, BOD 5, SS, TN, and TP were 60%, 80%, 74%, 49% and 79%, respectively, when septic tank effluent was treated by vertical flow filter. So the concentration of COD and BOD\-5 in the treated effluent could meet the quality standard for irrigation water. After that the treated effluent was used for hydroponic cultivation of water spinach and romaine lettuce, the removal efficiencies of the whole system for COD, BOD\-5, SS, TN and TP were 71 4%, 97 5%, 96 9%, 86 3%, and 87 4%, respectively. And it could meet the integrated wastewater discharge standard for secondary biological treatment plant. It was found that using treated effluent for hydroponic cultivation of vegetables could reduce the nitrate content in vegetables. The removal rates for total bacteria and coliform index by using vertical flow bed system with cinder substrate were 80%—90% and 85%—96%, respectively.展开更多
As an important design factor for constructed wetlands,hydraulic retention time and its distribution will affect the treatment performance.Instantaneously injected sodium chloride tracers were used to obtain residence...As an important design factor for constructed wetlands,hydraulic retention time and its distribution will affect the treatment performance.Instantaneously injected sodium chloride tracers were used to obtain residence time distributions of the lab scale subsurface flow constructed wetland.Considering the presence of trailing and multiple peaks of the tracer breakthrough curve,the multi flow dispersion model(MFDM)was used to fit the experimental tracer breakthrough curves.According to the residual sum of squares and comparison between the experimental values and simulated values of the tracer concentration,MFDM could fit the residence time distribution(RTD)curve satisfactorily,the results of which also reflected the layered structure of wetland cells,thus to give reference for application of MFDM to the same kind of subsurface flow constructed wetlands.展开更多
Experiments in monitoring the removal of organic material and nitrogen and determining the amounts of mi- croorganism at different sites in the subsurface flow constructed wetland in Sihong county were performed. The ...Experiments in monitoring the removal of organic material and nitrogen and determining the amounts of mi- croorganism at different sites in the subsurface flow constructed wetland in Sihong county were performed. The results show that the removal of CODCr agrees with the kinetic equation of a first order reaction. The removal of pollutants varies with different seasons. The removal rates of CODCr, NH3-N, TN in the spring are 15%–23% higher than those in the autumn. The amount of ammonifier is larger than that of denitrifying bacteria and the amount of denitrifying bacte- ria is larger than that of nitrosomonas. The amount of bacteria around the plant roots is larger than that on the surface of the packing medium. No apparent change is observed for the amount of denitrifying bacteria and nitrosomonas between spring and autumn.展开更多
Livestock wastewater has been a major contributor to Chinese cultural eutrophication of surface waters. Constructed wetlands are under study as a best management practice to treat wastewater from dairy and swine opera...Livestock wastewater has been a major contributor to Chinese cultural eutrophication of surface waters. Constructed wetlands are under study as a best management practice to treat wastewater from dairy and swine operations, but the removal efficiency of pollutants is relatively low. Enhancing the treatment efficiency of livestock wastewater by effluent recirculation was investigated in a pilot-scale vertical-flow constructed wetland. The wetland system was composed of downflow and upflow stages, on which narrow-leaf Phragmites communis and common reed Phragraites Typhia are planted, respectively; each stage has a dimension of 4 m^2 (2 m × 2 m). Wastewater from facultative pond was fed into the system intermittently at a flow rate of 0.4 m^3/d. Recirculation rates of 0, 25%, 50%, 100% and 150% were adopted to evaluate the effect of the recirculation rate on pollutants removal. It shows that with effluent recirculation the average removal efficiencies of NH4-N, biological oxygen demand (BOD5) and suspended solids(SS) obviously increase to 61.7%, 81.3%, and 77.1%, respectively, in comparison with the values of 35.6%, 50.2%, and 49.3% without effluent recirculation. But the improvement of TP removal is slight, only from 42.3% to 48.9%. The variations of NH4-N, dissolved oxygen(DO) and oxidation-reduction potential(ORP) of inflow and outflow reveal that the adoption of effluent recirculation is benefi- cial to the formation of oxide environment in wetland. The exponential relationships with excellent correlation coefficients (R2 〉0.93) are found between the removal rates of NH4-N and BOD5 and the recirculation rates. With recirculation the pH value of the outflow decreases as the alkalinity is consumed by gradually enhanced nitrification process. When recirculation rate is kept constant 100%, the ambient temperature appears to affect NH4-N removal, but does not have significant influence on BOD5 removal.展开更多
The paper reports the findings of a research work carried out to examine the performance and efficiency of a subsurface constructed wetland (SSFCW) for the treatment of domestic sewage in the University of Lagos (Unil...The paper reports the findings of a research work carried out to examine the performance and efficiency of a subsurface constructed wetland (SSFCW) for the treatment of domestic sewage in the University of Lagos (Unilag), Nigeria. The removal patterns and efficiencies of the physical, chemical and biological sewage pollutants parameters of domestic waste water generated within Unilag community by the SSFCW were studied. The wastewater was sampled and analysed along the SSFCW from influent (point1) to effluent (point 11). Total Dissolved Solids (TDS) reduced from 471 mg/l to 11.85 mg/l (97.48%), Turbidity reduced from 108.75 HTU to 0.05HTU (99.95%), Manganese reduced from 6.05 mg/l to 0.61 mg/ (89.92%), Nitrate reduced from 27.5 mg/l to 2.0 mg/l (92.73%), Sulphate reduced from 48.5 mg/l to 28 mg/l (42.27%), Iron reduced from 1.13 mg/l to 0.03 mg/l (97.35%), BOD reduced from 73.14 mg/l to 12.8 mg/l (82.5%), and E-coli reduced from 874 MPN/100 ml to 0.15 MPN/100 ml (99.98%). On the other hand, Dissolved Oxygen content increased along the SSFCW from 3.14 mg/l to 7.49 mg/l (138.54%) while the pH improved from slightly acid level of 6.49 to slightly above neutral level of 7.05 (9.3%). All the parameters at effluent point are within the Nigerian Federal Environmental Protection Agency (FEPA) acceptable standard. The study concludes that the SSFCW is a cheap, efficient and appropriate technology for the treatment of domestic sewage under tropical conditions.展开更多
With the increase of requirement for ecological function of environment,for quality of water environment,for sewage treatment cost and for comprehensive utilization of water resources,it was bound to introduce a new t...With the increase of requirement for ecological function of environment,for quality of water environment,for sewage treatment cost and for comprehensive utilization of water resources,it was bound to introduce a new type of ecological technology for pollution treatment which was low in cost,convenient in management and stable in operation.High-efficient vertical flow constructed wetland developed by Shenzhen Academy of Environmental Science was characterized by good landscape effect and high efficiency of pollutants removal,and it had been widely applied in sewa-ge treatment and recycling and in lake water circulation purification.A lot of practical results showed that this technology could achieve high removal efficiency of SS,COD,BOD5,NH4-N and TP and the removal rate had arrived at more than 80% when hydraulic loading was 0.33-0.50 m/d.Effluent quality had met the water quality standard for recycling of urban sewage.展开更多
The effects of single Cd^(2+)and Pb^(2+),and combined Cd^(2+)and Pb^(2+)on dehydrogenase activity and polysaccharide content of the substrate biofilms in the integrated vertical-flow constructed wetland(IVCW)were stud...The effects of single Cd^(2+)and Pb^(2+),and combined Cd^(2+)and Pb^(2+)on dehydrogenase activity and polysaccharide content of the substrate biofilms in the integrated vertical-flow constructed wetland(IVCW)were studied.Dehydrogenase activities decreased linearly with the increasing concentrations of Cd^(2+)and Pb^(2+)at different times(6,24,72,and 120 h).The activities at both 6 and 24 h were significantly higher than that at 72 and 120 h in the case of single and combined treatments.The single Cd^(2+)and...展开更多
This study evaluates the performance of shale from Ivory Coast used as substrate in vertical-flow constructed wetlands in removal of phosphates and nitrogen. The pilot-scale artificial wetland has been duplicated: fil...This study evaluates the performance of shale from Ivory Coast used as substrate in vertical-flow constructed wetlands in removal of phosphates and nitrogen. The pilot-scale artificial wetland has been duplicated: filter planted with Panicum maximun and unplanted. They were set up outdoors, and fed with a municipal wastewater. The wetlands have been fed with three batches per week (intermittent) over a period of 3 months. During the operation period, the hydraulic residence time (HRT) 52 h was used, while wastewater temperatures varied from about ~33°C. The removal performance of the constructed wetland units was very good, since it reached on an average 98%, 89.4%, 89.4%, 84%, 80%, 84.8% and 92% for TSS, DOC, BOD<sub>5</sub>, , TKN, TP and respectively. In addition, the vegetation did not demonstrate superior performance to unplanted controls. Therefore, this study focuses on the role of shale in the phosphorus and nitrogen removal from wastewater by constructed wetland.展开更多
Constructed wetlands (CWs) can achieve a high-quality wastewater treatment and a quality that meets the prescribed standard, defined by legislation on wastewater discharge. A limitation in the application of construct...Constructed wetlands (CWs) can achieve a high-quality wastewater treatment and a quality that meets the prescribed standard, defined by legislation on wastewater discharge. A limitation in the application of constructed wetlands (CWs) is the large area requirement, which limits their application. The subject matter of this research is to check the possibility of improving the efficiency of wastewater treatment and reducing the required area for constructed wetlands (CWs) by using an adequate substrate under the conditions found in Montenegro. In the described experiment, the constructed wetlands (CW) have a vertical flow system and play the role of a secondary wastewater treatment, receiving water from the existing WWTP in Podgorica after the primary treatment. These vertical flow systems reflect experience with the use of similar systems in Slovenija, Austria and Italy. Measurements to date show that the substrate plays an important role and that wastewater treatment efficacy varies significantly with respect to the type of substrate when used under the conditions available in Montenegro.展开更多
In this study, the project of constructed wetland for treatment of tailwater from the wastewater treatment plant in Wudang Mountain was taken as an example, and the technological processes, pollution load, wetland bed...In this study, the project of constructed wetland for treatment of tailwater from the wastewater treatment plant in Wudang Mountain was taken as an example, and the technological processes, pollution load, wetland bed structure, bed filler, selection of plants and hydraulic conditions of the subsurface flow constructed wetland were discussed. A subsurface flow constructed wetland, which covered an area of 7 227 m^2 was finally designed. It could treat 7 000 m^3 of tailwater from the wastewater treatment plant a day. In addition, the system could reduce the emission of COD, BODs, TN, TP and NH3-N by 25.55, 25.55, 12.78, 1.28 and 17.89 t respectively a day. The outlet water was proved to reach the Standard A of the first class in Discharge Standard of Pollutants for Municipal Wastewater Treatment Plant (GB 18918-2002).展开更多
Factors affecting total nitrogen(TN) removal rates in constructed wetland were investigated by intermittent operation in the subsurface flow(SSF) constructed wetland system.The results demonstrated that removal rates ...Factors affecting total nitrogen(TN) removal rates in constructed wetland were investigated by intermittent operation in the subsurface flow(SSF) constructed wetland system.The results demonstrated that removal rates of TN increased with the rising of TN pollution load(1.40-12.40 g/m2) when the retention time was determined by 60% TN removal efficiency(n=180,p<0.05) in SSF wetlands.The maximum TN removal rate was 1.71 g/(m2·d) in SSF Phragmites australis-soil-slag system.TN removal rates were affected by total phosphorus load in case of higher TN load.TN removal rates in SSF Phragmites australis wetlands were greater than that in SSF Calamagrostis angustifolia wetlands at the same experimental cycle.Effect of wetland substrates on TN removal rates varied with the pollutants loading in SSF constructed wetland system,plant species and plant-growing period.展开更多
In this study constructed wetlands (CWs) were used to remove three heavy metals (Zn, Cu and Pb). The two tested substrates were made of coke and gravel, respectively. First order dynamic model was appropriate to descr...In this study constructed wetlands (CWs) were used to remove three heavy metals (Zn, Cu and Pb). The two tested substrates were made of coke and gravel, respectively. First order dynamic model was appropriate to describe removing of Zn and Cu. The experimental results showed that first dynamic removal rate constants of Zn in CWs with coke and gravel were 0.2326 h-1 and 0.1222 h-1, respectively. And those of Cu in CWs with coke and gravel were 0.2017 h-1 and 0.3739 h-1. However, removal efficiencies of Pb in the coke system and the gravel system were within 95-99%, so the first order dynamic model failed to fit the experimental data because the hydraulic resident times of Pb did not affect outlet concentration of Pb. From the removal rate constants, it is found that the coke and gravel system have different absorption efficiencies of heavy metal pollutants. Therefore, it is suggested that the removal efficiencies of heavy metals are influenced by the choice of substrates to some extent.展开更多
The integrated wetland systems were constructed by combining horizontal-flow and vertical-flow bed, and their purification efficiencies for septic tank effluent were detected when the hydraulic retention time (HRT) ...The integrated wetland systems were constructed by combining horizontal-flow and vertical-flow bed, and their purification efficiencies for septic tank effluent were detected when the hydraulic retention time (HRT) was 1 d, 3 d, 5 d under different seasons. The results showed that the removal efficiencies of the organics, phosphorus were steady in the hybrid systems, but the removal efficiency of total nitrogen was not steady due to high total nitrogen concentration in the septic tank effluent. The average removal rates of COD (chemical oxygen demand) were 89%, 87%, 83%, and 86% in summer, autumn, winter and spring, respectively, and it was up to 88%, 85%, 73%, and 74% for BOD5 (5 d biochemical oxygen demand) removal rate in four seasons. The average removal rates of TP (total phosphorous) could reach up to 97%, 98%, 95%, 98% in four seasons, but the removal rate of TN (total nitrogen) was very low. The results of this study also indicated that the capability of purification was the worst in winter. Cultivating with plants could improve the treated effluent quality fTom the hybrid systems. The results of the operation of the horizontal-flow and vertical-flow cells (hybrid systems) showed that the removal efficiencies of the organics, TP and TN in horizontal-flow and vertical-flow cells were improved significantly with the extension of HRT under the same season. The removal rate of 3 d HRT was obviously higher than that of 1 d HRT, and the removal rate of 5 d HRT was better than that of 3 d HRT, but the removal efficiency was not very obvious with the increment of HRT. Therefore, 3 d HRT might be recommended in the actual operation of the hybrid systems for economic and technical reasons.展开更多
基金Supported by National Major Science and Technology Projects(2009ZX07317-006)National Major Science and Technology Projects(2009ZX07317-009)~~
文摘[Objective]The activities of urease and phosphatase in integrated vertical flow constructed wetland and purification effect of black and malodorous river were studied.[Method]Honeycomb stone and soft filler were used as matrix,the biological grid integrated vertical flow constructed wetland system was built to strengthen treatment for black and malodorous river,and the activities of urease and phosphatase of two fillers in different functional areas of constructed wetland were tested to study the film formation property of two fillers in different functional areas.[Result]Both urease and phosphatase activities on biofilm of soft filler were significantly higher than on biofilm of honeycomb stone filler;indicating that choosing soft filler was more advantageous to the growth of biofilm;and urease activity had significant correlation with total nitrogen removal rate,while phosphatase activity had no significant correlation with total phosphorus removal rate.[Conclusion]This study provided evidences for utilizing the activities of urease and phosphatase to evaluate the purification effect of black and malodorous river and choose appropriate filler.
基金Supported by National Natural Science Foundation of China(41071214)~~
文摘[Objective] The aim was to al eviate the constructed wetland clogging problems and to explore to the effects of hydraulic loading on wetland clogging. [Method] The experiment, through artificial soil columns, simulated vertical flow arti-ficial wetland, set four hydraulic load level at 50, 100, 150 and 200 cm/d, to identify the impact of hydraulic loading on wetland clogging and to explore the factors run-ning threshold. [Result] The results show that the different levels of hydraulic loading have greater impact; in the constructed wetland clogging process under high hy-draulic loading of 200 cm/d, the effective life was only six months, and the single factor can be speculated that the threshold of the hydraulic load should be at 100-150 cm/d; system can last for six months at low hydraulic loading and last for three months at medium hydraulic load. [Conclusion] The research provides references for wetland clogging experiments in future.
文摘This research explores strategies to enhance the efficiency of secondary treatment in Vertical Flow Constructed Wetlands (CW) in Montenegro. The focus is on selecting appropriate primary treatment methods alongside three distinct substrate types to improve wastewater treatment efficacy. The study examines the combination of two primary treatments with different substrate types in constructed wetlands (CW1, CW2, and CW3). The primary treatments include the existing wastewater treatment plant (WWTP) in Podgorica, involving coarse material removal through screens, inert material separation in aerated sand traps, and sediment and suspended matter removal in primary sedimentation tanks. The Extreme Separator (ExSep) was employed to evaluate its efficacy as a primary treatment method. The research demonstrates that the efficiency of CW can be significantly enhanced by selecting suitable primary treatment methods and substrates in Podgorica’s conditions. The most promising results were achieved by combining ExSep as a primary treatment with secondary treatment in CW-3. The removal efficiencies after CW3 for COD, BOD, and TSS exceeded 89%, 93%, and 91%, respectively. The outcomes underscore the significance of primary treatment in mitigating pollutant loads before discharge into the constructed wetlands, emphasizing potential areas for further optimization in wastewater treatment practices to enhance environmental sustainability and water quality management.
文摘The operational performance of a full scale subsurface flow constructed wetland, which treated the mixed industrial and domestic wastewater with BOD 5/COD mean ratio of 0 33 at Shatian, Shenzhen City was studied. The constructed wetland system consists of screens, sump, pumping station, and primary settling basin, facultative pond, first stage wetland and secondary stage wetland. The designed treatment capacity is 5000 m 3/d, and the actual influent flow is in the range of <2000 to >10000 m 3/d. Under normal operational conditions, the final effluent quality well met the National Integrated Wastewater Discharge Standard(GB 8978\_1996), with the following parameters(mean values): COD 33 90 mg/L, BOD 5 7.65 mg/L, TSS 7.92 mg/L, TN 9.11 mg/L and TP 0 56 mg/L. Seven species of plants were selected to grow in the wetland: Reed, Sweetcane flower Silvergrass, Great Bulrush, Powdery Thalia and Canna of three colours. The growing season is a whole year round. The seasonal discrepancy could be observed and the plants growing in the wetland are vulnerable to lower temperature in winter. The recycling of the effluent in the first stage of the wetland system is an effective measure to improve the performance of the wetland system. The insufficient DO value in the wetland system not only had significant effect on pollutants removal in the wetland, but also was unfavourable to plant growth. The recycling of effluent to the inlet of wetland system and artificial pond to increase DO value of influent to the wetland is key to operate the subsurface constructed wetland steadily and effectively.
文摘Vertical flow constructed wetlands is a typical ecological sanitation system for sewage treatment. The removal rates for COD, BOD 5, SS, TN, and TP were 60%, 80%, 74%, 49% and 79%, respectively, when septic tank effluent was treated by vertical flow filter. So the concentration of COD and BOD\-5 in the treated effluent could meet the quality standard for irrigation water. After that the treated effluent was used for hydroponic cultivation of water spinach and romaine lettuce, the removal efficiencies of the whole system for COD, BOD\-5, SS, TN and TP were 71 4%, 97 5%, 96 9%, 86 3%, and 87 4%, respectively. And it could meet the integrated wastewater discharge standard for secondary biological treatment plant. It was found that using treated effluent for hydroponic cultivation of vegetables could reduce the nitrate content in vegetables. The removal rates for total bacteria and coliform index by using vertical flow bed system with cinder substrate were 80%—90% and 85%—96%, respectively.
基金Under the auspices of the Creative Group Foundation of the National Natural Science Foundation of China(50721006)the National Basic Research Program of China(2006CB403402-3)+1 种基金the National Water Resource and Environment Special Item(2008ZX07207-006-04)the Natural Science Foundation of Shanghai(10ZR1400300)
文摘As an important design factor for constructed wetlands,hydraulic retention time and its distribution will affect the treatment performance.Instantaneously injected sodium chloride tracers were used to obtain residence time distributions of the lab scale subsurface flow constructed wetland.Considering the presence of trailing and multiple peaks of the tracer breakthrough curve,the multi flow dispersion model(MFDM)was used to fit the experimental tracer breakthrough curves.According to the residual sum of squares and comparison between the experimental values and simulated values of the tracer concentration,MFDM could fit the residence time distribution(RTD)curve satisfactorily,the results of which also reflected the layered structure of wetland cells,thus to give reference for application of MFDM to the same kind of subsurface flow constructed wetlands.
文摘Experiments in monitoring the removal of organic material and nitrogen and determining the amounts of mi- croorganism at different sites in the subsurface flow constructed wetland in Sihong county were performed. The results show that the removal of CODCr agrees with the kinetic equation of a first order reaction. The removal of pollutants varies with different seasons. The removal rates of CODCr, NH3-N, TN in the spring are 15%–23% higher than those in the autumn. The amount of ammonifier is larger than that of denitrifying bacteria and the amount of denitrifying bacte- ria is larger than that of nitrosomonas. The amount of bacteria around the plant roots is larger than that on the surface of the packing medium. No apparent change is observed for the amount of denitrifying bacteria and nitrosomonas between spring and autumn.
文摘Livestock wastewater has been a major contributor to Chinese cultural eutrophication of surface waters. Constructed wetlands are under study as a best management practice to treat wastewater from dairy and swine operations, but the removal efficiency of pollutants is relatively low. Enhancing the treatment efficiency of livestock wastewater by effluent recirculation was investigated in a pilot-scale vertical-flow constructed wetland. The wetland system was composed of downflow and upflow stages, on which narrow-leaf Phragmites communis and common reed Phragraites Typhia are planted, respectively; each stage has a dimension of 4 m^2 (2 m × 2 m). Wastewater from facultative pond was fed into the system intermittently at a flow rate of 0.4 m^3/d. Recirculation rates of 0, 25%, 50%, 100% and 150% were adopted to evaluate the effect of the recirculation rate on pollutants removal. It shows that with effluent recirculation the average removal efficiencies of NH4-N, biological oxygen demand (BOD5) and suspended solids(SS) obviously increase to 61.7%, 81.3%, and 77.1%, respectively, in comparison with the values of 35.6%, 50.2%, and 49.3% without effluent recirculation. But the improvement of TP removal is slight, only from 42.3% to 48.9%. The variations of NH4-N, dissolved oxygen(DO) and oxidation-reduction potential(ORP) of inflow and outflow reveal that the adoption of effluent recirculation is benefi- cial to the formation of oxide environment in wetland. The exponential relationships with excellent correlation coefficients (R2 〉0.93) are found between the removal rates of NH4-N and BOD5 and the recirculation rates. With recirculation the pH value of the outflow decreases as the alkalinity is consumed by gradually enhanced nitrification process. When recirculation rate is kept constant 100%, the ambient temperature appears to affect NH4-N removal, but does not have significant influence on BOD5 removal.
文摘The paper reports the findings of a research work carried out to examine the performance and efficiency of a subsurface constructed wetland (SSFCW) for the treatment of domestic sewage in the University of Lagos (Unilag), Nigeria. The removal patterns and efficiencies of the physical, chemical and biological sewage pollutants parameters of domestic waste water generated within Unilag community by the SSFCW were studied. The wastewater was sampled and analysed along the SSFCW from influent (point1) to effluent (point 11). Total Dissolved Solids (TDS) reduced from 471 mg/l to 11.85 mg/l (97.48%), Turbidity reduced from 108.75 HTU to 0.05HTU (99.95%), Manganese reduced from 6.05 mg/l to 0.61 mg/ (89.92%), Nitrate reduced from 27.5 mg/l to 2.0 mg/l (92.73%), Sulphate reduced from 48.5 mg/l to 28 mg/l (42.27%), Iron reduced from 1.13 mg/l to 0.03 mg/l (97.35%), BOD reduced from 73.14 mg/l to 12.8 mg/l (82.5%), and E-coli reduced from 874 MPN/100 ml to 0.15 MPN/100 ml (99.98%). On the other hand, Dissolved Oxygen content increased along the SSFCW from 3.14 mg/l to 7.49 mg/l (138.54%) while the pH improved from slightly acid level of 6.49 to slightly above neutral level of 7.05 (9.3%). All the parameters at effluent point are within the Nigerian Federal Environmental Protection Agency (FEPA) acceptable standard. The study concludes that the SSFCW is a cheap, efficient and appropriate technology for the treatment of domestic sewage under tropical conditions.
文摘With the increase of requirement for ecological function of environment,for quality of water environment,for sewage treatment cost and for comprehensive utilization of water resources,it was bound to introduce a new type of ecological technology for pollution treatment which was low in cost,convenient in management and stable in operation.High-efficient vertical flow constructed wetland developed by Shenzhen Academy of Environmental Science was characterized by good landscape effect and high efficiency of pollutants removal,and it had been widely applied in sewa-ge treatment and recycling and in lake water circulation purification.A lot of practical results showed that this technology could achieve high removal efficiency of SS,COD,BOD5,NH4-N and TP and the removal rate had arrived at more than 80% when hydraulic loading was 0.33-0.50 m/d.Effluent quality had met the water quality standard for recycling of urban sewage.
文摘The effects of single Cd^(2+)and Pb^(2+),and combined Cd^(2+)and Pb^(2+)on dehydrogenase activity and polysaccharide content of the substrate biofilms in the integrated vertical-flow constructed wetland(IVCW)were studied.Dehydrogenase activities decreased linearly with the increasing concentrations of Cd^(2+)and Pb^(2+)at different times(6,24,72,and 120 h).The activities at both 6 and 24 h were significantly higher than that at 72 and 120 h in the case of single and combined treatments.The single Cd^(2+)and...
文摘This study evaluates the performance of shale from Ivory Coast used as substrate in vertical-flow constructed wetlands in removal of phosphates and nitrogen. The pilot-scale artificial wetland has been duplicated: filter planted with Panicum maximun and unplanted. They were set up outdoors, and fed with a municipal wastewater. The wetlands have been fed with three batches per week (intermittent) over a period of 3 months. During the operation period, the hydraulic residence time (HRT) 52 h was used, while wastewater temperatures varied from about ~33°C. The removal performance of the constructed wetland units was very good, since it reached on an average 98%, 89.4%, 89.4%, 84%, 80%, 84.8% and 92% for TSS, DOC, BOD<sub>5</sub>, , TKN, TP and respectively. In addition, the vegetation did not demonstrate superior performance to unplanted controls. Therefore, this study focuses on the role of shale in the phosphorus and nitrogen removal from wastewater by constructed wetland.
文摘Constructed wetlands (CWs) can achieve a high-quality wastewater treatment and a quality that meets the prescribed standard, defined by legislation on wastewater discharge. A limitation in the application of constructed wetlands (CWs) is the large area requirement, which limits their application. The subject matter of this research is to check the possibility of improving the efficiency of wastewater treatment and reducing the required area for constructed wetlands (CWs) by using an adequate substrate under the conditions found in Montenegro. In the described experiment, the constructed wetlands (CW) have a vertical flow system and play the role of a secondary wastewater treatment, receiving water from the existing WWTP in Podgorica after the primary treatment. These vertical flow systems reflect experience with the use of similar systems in Slovenija, Austria and Italy. Measurements to date show that the substrate plays an important role and that wastewater treatment efficacy varies significantly with respect to the type of substrate when used under the conditions available in Montenegro.
文摘In this study, the project of constructed wetland for treatment of tailwater from the wastewater treatment plant in Wudang Mountain was taken as an example, and the technological processes, pollution load, wetland bed structure, bed filler, selection of plants and hydraulic conditions of the subsurface flow constructed wetland were discussed. A subsurface flow constructed wetland, which covered an area of 7 227 m^2 was finally designed. It could treat 7 000 m^3 of tailwater from the wastewater treatment plant a day. In addition, the system could reduce the emission of COD, BODs, TN, TP and NH3-N by 25.55, 25.55, 12.78, 1.28 and 17.89 t respectively a day. The outlet water was proved to reach the Standard A of the first class in Discharge Standard of Pollutants for Municipal Wastewater Treatment Plant (GB 18918-2002).
基金Under the auspices of the Knowledge Innovation Project of Chinese Academy of Sciences (KZCX2-YW-Q06-03)the National Natural Science Foundation of China (40901128)
文摘Factors affecting total nitrogen(TN) removal rates in constructed wetland were investigated by intermittent operation in the subsurface flow(SSF) constructed wetland system.The results demonstrated that removal rates of TN increased with the rising of TN pollution load(1.40-12.40 g/m2) when the retention time was determined by 60% TN removal efficiency(n=180,p<0.05) in SSF wetlands.The maximum TN removal rate was 1.71 g/(m2·d) in SSF Phragmites australis-soil-slag system.TN removal rates were affected by total phosphorus load in case of higher TN load.TN removal rates in SSF Phragmites australis wetlands were greater than that in SSF Calamagrostis angustifolia wetlands at the same experimental cycle.Effect of wetland substrates on TN removal rates varied with the pollutants loading in SSF constructed wetland system,plant species and plant-growing period.
文摘In this study constructed wetlands (CWs) were used to remove three heavy metals (Zn, Cu and Pb). The two tested substrates were made of coke and gravel, respectively. First order dynamic model was appropriate to describe removing of Zn and Cu. The experimental results showed that first dynamic removal rate constants of Zn in CWs with coke and gravel were 0.2326 h-1 and 0.1222 h-1, respectively. And those of Cu in CWs with coke and gravel were 0.2017 h-1 and 0.3739 h-1. However, removal efficiencies of Pb in the coke system and the gravel system were within 95-99%, so the first order dynamic model failed to fit the experimental data because the hydraulic resident times of Pb did not affect outlet concentration of Pb. From the removal rate constants, it is found that the coke and gravel system have different absorption efficiencies of heavy metal pollutants. Therefore, it is suggested that the removal efficiencies of heavy metals are influenced by the choice of substrates to some extent.
文摘The integrated wetland systems were constructed by combining horizontal-flow and vertical-flow bed, and their purification efficiencies for septic tank effluent were detected when the hydraulic retention time (HRT) was 1 d, 3 d, 5 d under different seasons. The results showed that the removal efficiencies of the organics, phosphorus were steady in the hybrid systems, but the removal efficiency of total nitrogen was not steady due to high total nitrogen concentration in the septic tank effluent. The average removal rates of COD (chemical oxygen demand) were 89%, 87%, 83%, and 86% in summer, autumn, winter and spring, respectively, and it was up to 88%, 85%, 73%, and 74% for BOD5 (5 d biochemical oxygen demand) removal rate in four seasons. The average removal rates of TP (total phosphorous) could reach up to 97%, 98%, 95%, 98% in four seasons, but the removal rate of TN (total nitrogen) was very low. The results of this study also indicated that the capability of purification was the worst in winter. Cultivating with plants could improve the treated effluent quality fTom the hybrid systems. The results of the operation of the horizontal-flow and vertical-flow cells (hybrid systems) showed that the removal efficiencies of the organics, TP and TN in horizontal-flow and vertical-flow cells were improved significantly with the extension of HRT under the same season. The removal rate of 3 d HRT was obviously higher than that of 1 d HRT, and the removal rate of 5 d HRT was better than that of 3 d HRT, but the removal efficiency was not very obvious with the increment of HRT. Therefore, 3 d HRT might be recommended in the actual operation of the hybrid systems for economic and technical reasons.