High-voltage circuit breakers are the core equipment in power networks,and to a certain extent,are related to the safe and reliable operation of power systems.However,their core components are prone to mechanical faul...High-voltage circuit breakers are the core equipment in power networks,and to a certain extent,are related to the safe and reliable operation of power systems.However,their core components are prone to mechanical faults.This study proposes a component separation method to detect multiple mechanical faults in circuit breakers that can achieve online real-time monitoring.First,a model and strategy are presented for obtaining mechanical voiceprint signals from circuit breakers.Subsequently,the component separation method was used to decompose the voiceprint signals of multiple faults into individual component signals.Based on this,the recognition of the features of a single-fault voiceprint signal can be achieved.Finally,multiple faults in high-voltage circuit breakers were identified through an experimental simulation and verification of the circuit breaker voiceprint signals collected from the substation site.The research results indicate that the proposed method exhibits excellent performance for multiple mechanical faults,such as spring structures and loose internal components of circuit breakers.In addition,it provides a reference method for the real-time online monitoring of high-voltage circuit breakers.展开更多
It is important to achieve continuous, stable and efficient pumping well operation in actual oilfield operation. Down-hole pumping well working conditions can be monitored in real-time and a reasonable production sche...It is important to achieve continuous, stable and efficient pumping well operation in actual oilfield operation. Down-hole pumping well working conditions can be monitored in real-time and a reasonable production scheme can be designed when computer diagnosis is used. However, it is difficult to make a comprehensive analysis to supply efficient technical guidance for operation of the pumping well with multiple faults of down-hole conditions, which cannot be effectively dealt with by the common methods. To solve this problem, a method based on designated component analysis (DCA) is used in this paper. Freeman chain code is used to represent the down-hole dynamometer card whose important characteristics are extracted to construct a designated mode set. A control chart is used as a basis for fault detection. The upper and lower control lines on the control chart are determined from standard samples in normal working conditions. In an incompletely orthogonal mode, the designated mode set could be divided into some subsets in which the modes are completely orthogonal. The observed data is projected into each designated mode to realize fault detection according to the upper and lower control lines. The examples show that the proposed method can effectively diagnose multiple faults of down-hole conditions.展开更多
Up to present,the problem of the evaluation of fault diagnosability for nonlinear systems has been investigated by many researchers.However,no attempt has been done to evaluate the diagnosability of multiple faults oc...Up to present,the problem of the evaluation of fault diagnosability for nonlinear systems has been investigated by many researchers.However,no attempt has been done to evaluate the diagnosability of multiple faults occurring simultaneously for nonlinear systems.This paper proposes a method based on differential geometry theories to solve this problem.Then the evaluation of fault diagnosability for affine nonlinear systems with multiple faults occurring simultaneously is achieved.To deal with the effect of control laws on the evaluation results of fault diagnosability,a design scheme of the evaluation of fault diagnosability is proposed.Then the influence of uncertainties on the evaluation results of fault diagnosability for affine nonlinear systems with multiple faults occurring simultaneously is analyzed.The numerical simulation results are obtained to show the effectiveness of the proposed evaluation scheme of fault diagnosability.展开更多
The fault diagnosis problem is investigated for a class of nonlinear neutral systems with multiple disturbances.Time-varying faults are considered and multiple disturbances are supposed to include the unknown disturba...The fault diagnosis problem is investigated for a class of nonlinear neutral systems with multiple disturbances.Time-varying faults are considered and multiple disturbances are supposed to include the unknown disturbance modeled by an exo-system and norm bounded uncertain disturbance.A nonlinear disturbance observer is designed to estimate the modeled disturbance.Then,the fault diagnosis observer is constructed by integrating disturbance observer with disturbance attenuation and rejection performances.The augmented Lyapunov functional approach,which involves the tuning parameter and slack variable,is applied to make the solution of inequality more flexible.Finally,applications for a two-link robotic manipulator system are given to show the efficiency of the proposed approach.展开更多
With the complexity of integrated circuits is continually increasing, a local defect in circuits may cause multiple faults. The behavior of a digital circuit with a multiple fault may significantly differ from that of...With the complexity of integrated circuits is continually increasing, a local defect in circuits may cause multiple faults. The behavior of a digital circuit with a multiple fault may significantly differ from that of a single fault. A new method for the detection of multiple faults in digital circuits is presented in this paper, the method is based on binary decision diagram (BDD). First of all, the BDDs for the normal circuit and faulty circuit are built respectively. Secondly, a test BDD is obtained by the XOR operation of the BDDs corresponds to normal circuit and faulty circuit. In the test BDD, each input assignment that leads to the leaf node labeled 1 is a test vector of multiple faults. Therefore, the test set of multiple faults is generated by searching for the type of input assignments in the test BDD. Experimental results on some digital circuits show the feasibility of the approach presented in this paper.展开更多
The single fault and multiple fault detections for multiple-valued logic circuits are studied in this paper. Firstly, it is shown that the cardinality of optimal single fault test set for fanout-free m-valued circuits...The single fault and multiple fault detections for multiple-valued logic circuits are studied in this paper. Firstly, it is shown that the cardinality of optimal single fault test set for fanout-free m-valued circuits with n primary inputs is not more than n + 1, for linear tree circuits is two, and for multiplication modulo circuits is two if n is an odd number or if n is an even number and m > 3, where the optimal test set of a circuit has minimal number of test vectors. Secondly,it is indicated that the cardinality of optimal multiple fault test set for linear tree circuits with n primary inputs is 1 + [n/(m - 1)], for multiplication modulo circuits is n+ 1, for fanout-free circuits that consist of 2-input linear tree circuits and 2-input multiplication modulo circuits is not greater than n+ 1, where [x] denotes the smallest integer greater than or equal to x. Finally,the single fault location approaches of linear tree circuits and multiplication modulo circuits are presented, and all faults in the two types of circuits can be located by using a test set with n + 1 vectors.展开更多
Understanding the strength characteristics and deformation behaviour of the tunnel surrounding rock in a fault zone is significant for tunnel stability evaluation.In this study,a series of unconfined compression tests...Understanding the strength characteristics and deformation behaviour of the tunnel surrounding rock in a fault zone is significant for tunnel stability evaluation.In this study,a series of unconfined compression tests were conducted to investigate the mechanical characteristics and failure behaviour of completely weathered granite(CWG)from a fault zone,considering with height-diameter(h/d)ratio,dry densities(ρd)and moisture contents(ω).Based on the experimental results,a regression mathematical model of unconfined compressive strength(UCS)for CWG was developed using the Multiple Nonlinear Regression method(MNLR).The research results indicated that the UCS of the specimen with a h/d ratio of 0.6 decreased with the increase ofω.When the h/d ratio increased to 1.0,the UCS increasedωwith up to 10.5%and then decreased.Increasingρd is conducive to the improvement of the UCS at anyω.The deformation and rupture process as well as final failure modes of the specimen are controlled by h/d ratio,ρd andω,and the h/d ratio is the dominant factor affecting the final failure mode,followed byωandρd.The specimens with different h/d ratio exhibited completely different fracture mode,i.e.,typical splitting failure(h/d=0.6)and shear failure(h/d=1.0).By comparing the experimental results,this regression model for predicting UCS is accurate and reliable,and the h/d ratio is the dominant factor affecting the UCS of CWG,followed byρd and thenω.These findings provide important references for maintenance of the tunnel crossing other fault fractured zones,especially at low confining pressure or unconfined condition.展开更多
Computational complexity of complex system multiple fault diagnosis is a puzzle at all times. Based on the well known Mozetic's approach, a novel hierarchical model-based diagnosis methodology is put forward for impr...Computational complexity of complex system multiple fault diagnosis is a puzzle at all times. Based on the well known Mozetic's approach, a novel hierarchical model-based diagnosis methodology is put forward for improving efficency of multi-fault recognition and localization. Structural abstraction and weighted fault propagation graphs are combined to build diagnosis model. The graphs have weighted arcs with fault propagation probabilities and propagation strength. For solving the problem of coupled faults, two diagnosis strategies are used: one is the Lagrangian relaxation and the primal heuristic algorithms; another is the method of propagation strength. Finally, an applied example shows the applicability of the approach and experimental results are given to show the superiority of the presented technique.展开更多
Multiple faults are easily confused with single faults.In order to identify multiple faults more accurately,a highly efficient learning method is proposed based on a double parallel two-hidden-layer extreme learning m...Multiple faults are easily confused with single faults.In order to identify multiple faults more accurately,a highly efficient learning method is proposed based on a double parallel two-hidden-layer extreme learning machine,called DPTELM.The DPT-ELM method is a variant of an extreme learning machine(ELM).There are some issues with ELM.First,achieving a high accuracy requires too many hidden nodes;second,the direct connection between the input layer and the output layer is ignored.Accordingly,to deal with the above-mentioned problems,DPT-ELM extends the single-hidden-layer ELM to a two-hidden-layer ELM,which can achieve a desired performance with fewer hidden nodes.In addition,a direct connection is built between the input layer and the output layer.Since the input layer weights and the thresholds of the two hidden layers are determined randomly,this simplifies the improved model and shortens the calculation time.Additionally,to improve the signal to noise ratio(SNR),an adaptive waveform decomposition(AWD)algorithm is used to denoise the vibration signal.Then,the denoised signal is used to extract the eigenvalues by the time-domain and frequency-domain methods.Finally,the eigenvalues are input to the DPT-ELM classifier.In this paper,two groups of rolling bearing data at different speeds,which were collected from a real experimental platform,are used to test the method.Each set of data includes three single fault states,two complex fault states and a healthy state.The experimental results demonstrate that the DPT-ELM method achieves fast learning speed and a high accuracy.Moreover,based on 10-fold cross-validation,it proves to be an effective method to improve the accuracy with fewer hidden nodes.展开更多
Constrained spectral non-negative matrix factorization(NMF)analysis of perturbed oscillatory process control loop variable data is performed for the isolation of multiple plant-wide oscillatory sources.The technique i...Constrained spectral non-negative matrix factorization(NMF)analysis of perturbed oscillatory process control loop variable data is performed for the isolation of multiple plant-wide oscillatory sources.The technique is described and demonstrated by analyzing data from both simulated and real plant data of a chemical process plant. Results show that the proposed approach can map multiple oscillatory sources onto the most appropriate control loops,and has superior performance in terms of reconstruction accuracy and intuitive understanding compared with spectral independent component analysis(ICA).展开更多
The problem of fault detection for linear discrete timevarying systems with multiplicative noise is dealt with.By using an observer-based robust fault detection filter(FDF) as a residual generator,the design of the ...The problem of fault detection for linear discrete timevarying systems with multiplicative noise is dealt with.By using an observer-based robust fault detection filter(FDF) as a residual generator,the design of the FDF is formulated in the framework of H ∞ filtering for a class of stochastic time-varying systems.A sufficient condition for the existence of the FDF is derived in terms of a Riccati equation.The determination of the parameter matrices of the filter is converted into a quadratic optimization problem,and an analytical solution of the parameter matrices is obtained by solving the Riccati equation.Numerical examples are given to illustrate the effectiveness of the proposed method.展开更多
Effective bearing fault diagnosis is vital for the safe and reliable operation of rotating machinery.In practical applications,bearings often work at various rotational speeds as well as load conditions.Yet,the bearin...Effective bearing fault diagnosis is vital for the safe and reliable operation of rotating machinery.In practical applications,bearings often work at various rotational speeds as well as load conditions.Yet,the bearing fault diagnosis under multiple conditions is a new subject,which needs to be further explored.Therefore,a multi-scale deep belief network(DBN)method integrated with attention mechanism is proposed for the purpose of extracting the multi-scale core features from vibration signals,containing four primary steps:preprocessing of multi-scale data,feature extraction,feature fusion,and fault classification.The key novelties include multi-scale feature extraction using multi-scale DBN algorithm,and feature fusion using attention mecha-nism.The benchmark dataset from University of Ottawa is applied to validate the effectiveness as well as advantages of this method.Furthermore,the aforementioned method is compared with four classical fault diagnosis methods reported in the literature,and the comparison results show that our pro-posed method has higher diagnostic accuracy and better robustness.展开更多
For achieving Energy-Efficiency in wireless sensor networks(WSNs),different schemes have been proposed which focuses only on reducing the energy consumption.A shortest path determines for the Base Station(BS),but faul...For achieving Energy-Efficiency in wireless sensor networks(WSNs),different schemes have been proposed which focuses only on reducing the energy consumption.A shortest path determines for the Base Station(BS),but fault tolerance and energy balancing gives equal importance for improving the network lifetime.For saving energy in WSNs,clustering is considered as one of the effective methods for Wireless Sensor Networks.Because of the excessive overload,more energy consumed by cluster heads(CHs)in a cluster based WSN to receive and aggregate the information from member sensor nodes and it leads to failure.For increasing the WSNs’lifetime,the CHs selection has played a key role in energy consumption for sensor nodes.An Energy Efficient Unequal Fault Tolerant Clustering Approach(EEUFTC)is proposed for reducing the energy utilization through the intelligent methods like Particle Swarm Optimization(PSO).In this approach,an optimal Master Cluster Head(MCH)-Master data Aggregator(MDA),selection method is proposed which uses the fitness values and they evaluate based on the PSO for two optimal nodes in each cluster to act as Master Data Aggregator(MDA),and Master Cluster Head.The data from the cluster members collected by the chosen MCH exclusively and the MDA is used for collected data reception from MCH transmits to the BS.Thus,the MCH overhead reduces.During the heavy communication of data,overhead controls using the scheduling of Energy-Efficient Time Division Multiple Access(EE-TDMA).To describe the proposed method superiority based on various performance metrics,simulation and results are compared to the existing methods.展开更多
基金supported by the State Key Laboratory of Technology and Equipment for Defense against Power System Operational Risks(No.SGNR0000KJJS2302137)the National Natural Science Foundation of China(Grant No.62203248)the Natural Science Foundation of Shandong Province(Grant No.ZR2020ME194).
文摘High-voltage circuit breakers are the core equipment in power networks,and to a certain extent,are related to the safe and reliable operation of power systems.However,their core components are prone to mechanical faults.This study proposes a component separation method to detect multiple mechanical faults in circuit breakers that can achieve online real-time monitoring.First,a model and strategy are presented for obtaining mechanical voiceprint signals from circuit breakers.Subsequently,the component separation method was used to decompose the voiceprint signals of multiple faults into individual component signals.Based on this,the recognition of the features of a single-fault voiceprint signal can be achieved.Finally,multiple faults in high-voltage circuit breakers were identified through an experimental simulation and verification of the circuit breaker voiceprint signals collected from the substation site.The research results indicate that the proposed method exhibits excellent performance for multiple mechanical faults,such as spring structures and loose internal components of circuit breakers.In addition,it provides a reference method for the real-time online monitoring of high-voltage circuit breakers.
基金supported by the Key Program of National Natural Science Foundation of China (61034005)Postgraduate Scientific Research and Innovation Projects of Basic Scientific Research Operating Expensesof Ministry of Education (N100604001)Excellent Doctoral Dissertations Cultivation Project of Northeastern University
文摘It is important to achieve continuous, stable and efficient pumping well operation in actual oilfield operation. Down-hole pumping well working conditions can be monitored in real-time and a reasonable production scheme can be designed when computer diagnosis is used. However, it is difficult to make a comprehensive analysis to supply efficient technical guidance for operation of the pumping well with multiple faults of down-hole conditions, which cannot be effectively dealt with by the common methods. To solve this problem, a method based on designated component analysis (DCA) is used in this paper. Freeman chain code is used to represent the down-hole dynamometer card whose important characteristics are extracted to construct a designated mode set. A control chart is used as a basis for fault detection. The upper and lower control lines on the control chart are determined from standard samples in normal working conditions. In an incompletely orthogonal mode, the designated mode set could be divided into some subsets in which the modes are completely orthogonal. The observed data is projected into each designated mode to realize fault detection according to the upper and lower control lines. The examples show that the proposed method can effectively diagnose multiple faults of down-hole conditions.
基金the Natural Science Foundation of Fujian Province,China(2019J05024)the Education Department Foundation of Fujian Province,China(JAT170091).
文摘Up to present,the problem of the evaluation of fault diagnosability for nonlinear systems has been investigated by many researchers.However,no attempt has been done to evaluate the diagnosability of multiple faults occurring simultaneously for nonlinear systems.This paper proposes a method based on differential geometry theories to solve this problem.Then the evaluation of fault diagnosability for affine nonlinear systems with multiple faults occurring simultaneously is achieved.To deal with the effect of control laws on the evaluation results of fault diagnosability,a design scheme of the evaluation of fault diagnosability is proposed.Then the influence of uncertainties on the evaluation results of fault diagnosability for affine nonlinear systems with multiple faults occurring simultaneously is analyzed.The numerical simulation results are obtained to show the effectiveness of the proposed evaluation scheme of fault diagnosability.
基金supported by the National Natural Science Foundation of China(6077401360925012)+1 种基金the National High Technology Research and Development Program of China(863 Program) (2008AA12A216)the National Basic Research Program of China (973 Program)(2009CB 724002)
文摘The fault diagnosis problem is investigated for a class of nonlinear neutral systems with multiple disturbances.Time-varying faults are considered and multiple disturbances are supposed to include the unknown disturbance modeled by an exo-system and norm bounded uncertain disturbance.A nonlinear disturbance observer is designed to estimate the modeled disturbance.Then,the fault diagnosis observer is constructed by integrating disturbance observer with disturbance attenuation and rejection performances.The augmented Lyapunov functional approach,which involves the tuning parameter and slack variable,is applied to make the solution of inequality more flexible.Finally,applications for a two-link robotic manipulator system are given to show the efficiency of the proposed approach.
基金Supported by the National Natural Science Foun-dation of China (60006002) Natural Science Research Project of Education Department of Guangdong Province of China (02019)
文摘With the complexity of integrated circuits is continually increasing, a local defect in circuits may cause multiple faults. The behavior of a digital circuit with a multiple fault may significantly differ from that of a single fault. A new method for the detection of multiple faults in digital circuits is presented in this paper, the method is based on binary decision diagram (BDD). First of all, the BDDs for the normal circuit and faulty circuit are built respectively. Secondly, a test BDD is obtained by the XOR operation of the BDDs corresponds to normal circuit and faulty circuit. In the test BDD, each input assignment that leads to the leaf node labeled 1 is a test vector of multiple faults. Therefore, the test set of multiple faults is generated by searching for the type of input assignments in the test BDD. Experimental results on some digital circuits show the feasibility of the approach presented in this paper.
基金Supported by the National Natural Science Foundation of China (No.60006002) Education Department of Guangdong Province of China (No. Z02019)
文摘The single fault and multiple fault detections for multiple-valued logic circuits are studied in this paper. Firstly, it is shown that the cardinality of optimal single fault test set for fanout-free m-valued circuits with n primary inputs is not more than n + 1, for linear tree circuits is two, and for multiplication modulo circuits is two if n is an odd number or if n is an even number and m > 3, where the optimal test set of a circuit has minimal number of test vectors. Secondly,it is indicated that the cardinality of optimal multiple fault test set for linear tree circuits with n primary inputs is 1 + [n/(m - 1)], for multiplication modulo circuits is n+ 1, for fanout-free circuits that consist of 2-input linear tree circuits and 2-input multiplication modulo circuits is not greater than n+ 1, where [x] denotes the smallest integer greater than or equal to x. Finally,the single fault location approaches of linear tree circuits and multiplication modulo circuits are presented, and all faults in the two types of circuits can be located by using a test set with n + 1 vectors.
基金Supported by National Basic Research Program of China(973 Program)(2012CB720505) the Fundamental Research Funds for the Central Universities(2012QNA5012)+1 种基金 Project of Education Department of Zhejiang Province(Y201223159) Technology Foundation for Selected Overseas Chinese Scholar of Zhejiang Province
基金supported by the National Natural Science Foundation of China,NSFC(No.42202318).
文摘Understanding the strength characteristics and deformation behaviour of the tunnel surrounding rock in a fault zone is significant for tunnel stability evaluation.In this study,a series of unconfined compression tests were conducted to investigate the mechanical characteristics and failure behaviour of completely weathered granite(CWG)from a fault zone,considering with height-diameter(h/d)ratio,dry densities(ρd)and moisture contents(ω).Based on the experimental results,a regression mathematical model of unconfined compressive strength(UCS)for CWG was developed using the Multiple Nonlinear Regression method(MNLR).The research results indicated that the UCS of the specimen with a h/d ratio of 0.6 decreased with the increase ofω.When the h/d ratio increased to 1.0,the UCS increasedωwith up to 10.5%and then decreased.Increasingρd is conducive to the improvement of the UCS at anyω.The deformation and rupture process as well as final failure modes of the specimen are controlled by h/d ratio,ρd andω,and the h/d ratio is the dominant factor affecting the final failure mode,followed byωandρd.The specimens with different h/d ratio exhibited completely different fracture mode,i.e.,typical splitting failure(h/d=0.6)and shear failure(h/d=1.0).By comparing the experimental results,this regression model for predicting UCS is accurate and reliable,and the h/d ratio is the dominant factor affecting the UCS of CWG,followed byρd and thenω.These findings provide important references for maintenance of the tunnel crossing other fault fractured zones,especially at low confining pressure or unconfined condition.
文摘Computational complexity of complex system multiple fault diagnosis is a puzzle at all times. Based on the well known Mozetic's approach, a novel hierarchical model-based diagnosis methodology is put forward for improving efficency of multi-fault recognition and localization. Structural abstraction and weighted fault propagation graphs are combined to build diagnosis model. The graphs have weighted arcs with fault propagation probabilities and propagation strength. For solving the problem of coupled faults, two diagnosis strategies are used: one is the Lagrangian relaxation and the primal heuristic algorithms; another is the method of propagation strength. Finally, an applied example shows the applicability of the approach and experimental results are given to show the superiority of the presented technique.
基金supported by National Natural Science Foundation of China(51675035/51375037)
文摘Multiple faults are easily confused with single faults.In order to identify multiple faults more accurately,a highly efficient learning method is proposed based on a double parallel two-hidden-layer extreme learning machine,called DPTELM.The DPT-ELM method is a variant of an extreme learning machine(ELM).There are some issues with ELM.First,achieving a high accuracy requires too many hidden nodes;second,the direct connection between the input layer and the output layer is ignored.Accordingly,to deal with the above-mentioned problems,DPT-ELM extends the single-hidden-layer ELM to a two-hidden-layer ELM,which can achieve a desired performance with fewer hidden nodes.In addition,a direct connection is built between the input layer and the output layer.Since the input layer weights and the thresholds of the two hidden layers are determined randomly,this simplifies the improved model and shortens the calculation time.Additionally,to improve the signal to noise ratio(SNR),an adaptive waveform decomposition(AWD)algorithm is used to denoise the vibration signal.Then,the denoised signal is used to extract the eigenvalues by the time-domain and frequency-domain methods.Finally,the eigenvalues are input to the DPT-ELM classifier.In this paper,two groups of rolling bearing data at different speeds,which were collected from a real experimental platform,are used to test the method.Each set of data includes three single fault states,two complex fault states and a healthy state.The experimental results demonstrate that the DPT-ELM method achieves fast learning speed and a high accuracy.Moreover,based on 10-fold cross-validation,it proves to be an effective method to improve the accuracy with fewer hidden nodes.
基金Supported by the Scientific Research Foundation for the Returned Overseas Chinese Scholars,State Education Ministry.
文摘Constrained spectral non-negative matrix factorization(NMF)analysis of perturbed oscillatory process control loop variable data is performed for the isolation of multiple plant-wide oscillatory sources.The technique is described and demonstrated by analyzing data from both simulated and real plant data of a chemical process plant. Results show that the proposed approach can map multiple oscillatory sources onto the most appropriate control loops,and has superior performance in terms of reconstruction accuracy and intuitive understanding compared with spectral independent component analysis(ICA).
基金supported by the National Natural Science Foundation of China (61174121,61121003)the National High Technology Researchand Development Program of China (863 Program) (2008AA121302)+1 种基金the National Basic Research Program of China (973 Program)(2009CB724000)the Research Fund for the Doctoral Program of Higher Education of China
文摘The problem of fault detection for linear discrete timevarying systems with multiplicative noise is dealt with.By using an observer-based robust fault detection filter(FDF) as a residual generator,the design of the FDF is formulated in the framework of H ∞ filtering for a class of stochastic time-varying systems.A sufficient condition for the existence of the FDF is derived in terms of a Riccati equation.The determination of the parameter matrices of the filter is converted into a quadratic optimization problem,and an analytical solution of the parameter matrices is obtained by solving the Riccati equation.Numerical examples are given to illustrate the effectiveness of the proposed method.
基金supported by the National Natural Science Foundation of China(62020106003,61873122,62303217)Aero Engine Corporation of China Industry-university-research Cooperation Project(HFZL2020CXY011)the Research Fund of State Key Laboratory of Mechanics and Control of Mechanical Structures(Nanjing University of Aeronautics and Astronautics)(MCMS-I-0121G03).
文摘Effective bearing fault diagnosis is vital for the safe and reliable operation of rotating machinery.In practical applications,bearings often work at various rotational speeds as well as load conditions.Yet,the bearing fault diagnosis under multiple conditions is a new subject,which needs to be further explored.Therefore,a multi-scale deep belief network(DBN)method integrated with attention mechanism is proposed for the purpose of extracting the multi-scale core features from vibration signals,containing four primary steps:preprocessing of multi-scale data,feature extraction,feature fusion,and fault classification.The key novelties include multi-scale feature extraction using multi-scale DBN algorithm,and feature fusion using attention mecha-nism.The benchmark dataset from University of Ottawa is applied to validate the effectiveness as well as advantages of this method.Furthermore,the aforementioned method is compared with four classical fault diagnosis methods reported in the literature,and the comparison results show that our pro-posed method has higher diagnostic accuracy and better robustness.
基金The authors would like to thank for the support from Taif University Researchers Supporting Project number(TURSP-2020/239),Taif University,Taif,Saudi Arabia.
文摘For achieving Energy-Efficiency in wireless sensor networks(WSNs),different schemes have been proposed which focuses only on reducing the energy consumption.A shortest path determines for the Base Station(BS),but fault tolerance and energy balancing gives equal importance for improving the network lifetime.For saving energy in WSNs,clustering is considered as one of the effective methods for Wireless Sensor Networks.Because of the excessive overload,more energy consumed by cluster heads(CHs)in a cluster based WSN to receive and aggregate the information from member sensor nodes and it leads to failure.For increasing the WSNs’lifetime,the CHs selection has played a key role in energy consumption for sensor nodes.An Energy Efficient Unequal Fault Tolerant Clustering Approach(EEUFTC)is proposed for reducing the energy utilization through the intelligent methods like Particle Swarm Optimization(PSO).In this approach,an optimal Master Cluster Head(MCH)-Master data Aggregator(MDA),selection method is proposed which uses the fitness values and they evaluate based on the PSO for two optimal nodes in each cluster to act as Master Data Aggregator(MDA),and Master Cluster Head.The data from the cluster members collected by the chosen MCH exclusively and the MDA is used for collected data reception from MCH transmits to the BS.Thus,the MCH overhead reduces.During the heavy communication of data,overhead controls using the scheduling of Energy-Efficient Time Division Multiple Access(EE-TDMA).To describe the proposed method superiority based on various performance metrics,simulation and results are compared to the existing methods.