Objective To evaluate the feasibility and accuracy of measurement of myocardial perfusion defects with intravenous contrast-enhanced real-time three-dimensional echocardiography (CE-RT3DE). Methods RT3DE was performed...Objective To evaluate the feasibility and accuracy of measurement of myocardial perfusion defects with intravenous contrast-enhanced real-time three-dimensional echocardiography (CE-RT3DE). Methods RT3DE was performed in 21 open-chest mongrel dogs undergoing acute ligation of the left anterior descending artery (LAD, n=14) or distal branch of the left circumflex artery (LCX, n=7). A perfluorocarbon microbubble contrast agent was injected intravenously to assess the resulting myocardial perfusion defects with Philips Sonos-7500 ultrasound system. Evans blue dye was injected into the occluded coronary artery for subsequent anatomic identification of underperfused myocardium. In vitro anatomic measurement of myocardial mass after removal of the animal’s heart was regarded as the control. Blinded off-line calculation of left ventricular mass and perfusion defect mass from RT3DE images were performed using an interactive aided-manual tracing technique.Results Total left ventricular (LV) myocardial mass ranged from 38.9 to 78.5 (mean±SD: 60.0±10.1) g. The mass of perfusion defect ranged from 0 to 21.4 (mean±SD: 12.0±5.0) g or 0 to 27% of total LV mass (mean±SD: 19%±6%). The RT3DE estimation of total LV mass (mean±SD: 59.8±9.9 g) strongly correlated with the anatomic measurement (r=0.98; y=2.01+0.96x). The CE-RT3DE calculation of the mass of underperfused myocardium (mean±SD: 12.3±5.3 g) also strongly correlated with the anatomic measurement (r=0.96; y=-0.10+1.04x) and when expressed as percentage of total LV mass (r=0.95; y=-0.20+1.04x). Conclusions RT3DE with myocardial contrast opacification could accurately estimate underperfused myocardial mass in dogs of acute coronary occlusion and would play an important role in quantitative assessment of myocardial perfusion defects in patients with coronary artery disease.展开更多
Objectives The long-term benefit of late reperfusion of infarct-related artery (IRA) after acute myocardial infarction (AMI) is controversial, and the benefit mechanisms remain uncertain. Low dose dobutamine stres...Objectives The long-term benefit of late reperfusion of infarct-related artery (IRA) after acute myocardial infarction (AMI) is controversial, and the benefit mechanisms remain uncertain. Low dose dobutamine stress echocardiography (LDSE) can identify viable myocardium and predict improvement of wall motion after revascularization. Methods Sixtynine patients with first AMI who did not received early reperfusion therapy were studied by LDSE at 5 to 10 days after AMI. Wall motion abnormality and left ventricular size were measured at the same time. Successful PCI were done in all patients at 10 to 21 days after AMI onset. Patients were divided in two groups based on the presence or absence of viable myocardium. Echocardiography was repeated six months later. Results There were 157 motion abnormality segments. 89 segments (57%) were viable during LDSE. 26 patients (38%) with viability and 43 (62%) without. In viable group, left ventricular ejection fraction (LVEF) was increased (P 〈 0.05), and left ventricular end systolic volume index (LVESVI) and wall motion score (WMS) were decreased (P 〈 0.05 and P 〈 0.01) significantly at 6 months compared with baseline. But in patients without viability, LVEF was decreased (P 〈 0.01), and LVESVI and left ventricular end diastolic volume index (LVEDVI) were increased (P 〈 0.05) significantly after 6 months, and the WMS did not changed (P 〉 0.05 ). LVEF increased (P 〈 0.05 ) and WMS decreased (P 〈 0.05) on LDSE during acute phase in patients with viability, but they were not changed in the nonviable group. Conclusions Late revascularization of IRA in patients with presence of viable myocardium after AMI is associated with long-term preservation left ventricular function and less ventricular remodeling. Improvement of left ventricular systolic function on LDSE indicates late phase recovery of left ventricular function after late revascularization.展开更多
Background Both real-time three-dimensional echocardi ography (RT3DE) and myocardial contrast echocardiography (MCE) are novel imaging techniques. The purpose of this study was to confirm the feasibility and accuracy ...Background Both real-time three-dimensional echocardi ography (RT3DE) and myocardial contrast echocardiography (MCE) are novel imaging techniques. The purpose of this study was to confirm the feasibility and accuracy of RT3DE combined with MCE for quantitative evaluation of myocardial perfusion defects. Methods Thirteen dogs underwent ligation of the left anterior descending artery (LAD, n=6) or distal branch of the left circumflex artery (LCX, n=7) under general anaesthesia. Three to four ml of a perfluoropropane (C 3F 8) microbubble contrast agent was injected intravenously to assess the resulting myocardial perfusion defects with a commercially available Philips SONOS-7500 ultrasound system. After removal of the dog hearts, Evans blue dye was injected via the left and righ t coronary arteries to stain the myocardium at risk. In vitro anatomic measurements of myocardial mass after removal of the animals’ hearts were used as control s. Results Left ventricular (LV) mass determined by RT3DE ranged 36.7-68.9 g [mean, (54.6±9.6) g] before coronary artery ligation, and correlated highly (r=0.99) with in vitro measurement of LV mass [range, 38.9-71.1 g; mean, (55.6±9.3) g]. There was no significant difference between RT3DE and in vitro measurements of LV mass [range, 36.7-68.9 g; mean, (51.3±12.5) g. Or range, 38.9-71. 1 g; mean, (53.7±12.3) g, respectively] and under-perfused mass [range, 0-21.4 g; mean, (12.0±6.9) g. Or range, 0-19.8 g; mean, (10.8±6.3) g, respectively] after th e LAD ligation (P>0.05). Likewise, no significant difference was present between RT3DE and in vitro measurements of LV mass [range, 50.1-65.4 g; mean, (57.5±5.9 ) g. Or range, 51.5-65.8 g; mean, (57.3±6.4) g, respectively] and under-perfused m ass [range, 0-25.6 g; mean, (13.3±9.6) g. Or range, 0-22.7 g; mean, (12.8±8.1 ) g, respectively] after the LCX ligation (P>0.05). For all the animals with coronary ligation, LV mass measured by RT3DE ranged 35.9-68.6 g [mean, (54.8±10.0) g] a nd there was no significant difference between RT3DE and in vitro measurements of LV mass and under-perfused mass (P>0.05, r=0.99). Further, the under-perfused mass derived from RT3DE [range, 0-25.6 g; mean, (12.7±8.2) g] correlate d strongly with the in vitro measurements [range, 0-22.7 g; mean, (11.9±7.2) g] ( r=0.96). Conclusion RT3DE with MCE is a rapid and accurate method for estimating LV myocardial mass and quantifying perfusion defects.展开更多
文摘Objective To evaluate the feasibility and accuracy of measurement of myocardial perfusion defects with intravenous contrast-enhanced real-time three-dimensional echocardiography (CE-RT3DE). Methods RT3DE was performed in 21 open-chest mongrel dogs undergoing acute ligation of the left anterior descending artery (LAD, n=14) or distal branch of the left circumflex artery (LCX, n=7). A perfluorocarbon microbubble contrast agent was injected intravenously to assess the resulting myocardial perfusion defects with Philips Sonos-7500 ultrasound system. Evans blue dye was injected into the occluded coronary artery for subsequent anatomic identification of underperfused myocardium. In vitro anatomic measurement of myocardial mass after removal of the animal’s heart was regarded as the control. Blinded off-line calculation of left ventricular mass and perfusion defect mass from RT3DE images were performed using an interactive aided-manual tracing technique.Results Total left ventricular (LV) myocardial mass ranged from 38.9 to 78.5 (mean±SD: 60.0±10.1) g. The mass of perfusion defect ranged from 0 to 21.4 (mean±SD: 12.0±5.0) g or 0 to 27% of total LV mass (mean±SD: 19%±6%). The RT3DE estimation of total LV mass (mean±SD: 59.8±9.9 g) strongly correlated with the anatomic measurement (r=0.98; y=2.01+0.96x). The CE-RT3DE calculation of the mass of underperfused myocardium (mean±SD: 12.3±5.3 g) also strongly correlated with the anatomic measurement (r=0.96; y=-0.10+1.04x) and when expressed as percentage of total LV mass (r=0.95; y=-0.20+1.04x). Conclusions RT3DE with myocardial contrast opacification could accurately estimate underperfused myocardial mass in dogs of acute coronary occlusion and would play an important role in quantitative assessment of myocardial perfusion defects in patients with coronary artery disease.
文摘Objectives The long-term benefit of late reperfusion of infarct-related artery (IRA) after acute myocardial infarction (AMI) is controversial, and the benefit mechanisms remain uncertain. Low dose dobutamine stress echocardiography (LDSE) can identify viable myocardium and predict improvement of wall motion after revascularization. Methods Sixtynine patients with first AMI who did not received early reperfusion therapy were studied by LDSE at 5 to 10 days after AMI. Wall motion abnormality and left ventricular size were measured at the same time. Successful PCI were done in all patients at 10 to 21 days after AMI onset. Patients were divided in two groups based on the presence or absence of viable myocardium. Echocardiography was repeated six months later. Results There were 157 motion abnormality segments. 89 segments (57%) were viable during LDSE. 26 patients (38%) with viability and 43 (62%) without. In viable group, left ventricular ejection fraction (LVEF) was increased (P 〈 0.05), and left ventricular end systolic volume index (LVESVI) and wall motion score (WMS) were decreased (P 〈 0.05 and P 〈 0.01) significantly at 6 months compared with baseline. But in patients without viability, LVEF was decreased (P 〈 0.01), and LVESVI and left ventricular end diastolic volume index (LVEDVI) were increased (P 〈 0.05) significantly after 6 months, and the WMS did not changed (P 〉 0.05 ). LVEF increased (P 〈 0.05 ) and WMS decreased (P 〈 0.05) on LDSE during acute phase in patients with viability, but they were not changed in the nonviable group. Conclusions Late revascularization of IRA in patients with presence of viable myocardium after AMI is associated with long-term preservation left ventricular function and less ventricular remodeling. Improvement of left ventricular systolic function on LDSE indicates late phase recovery of left ventricular function after late revascularization.
文摘Background Both real-time three-dimensional echocardi ography (RT3DE) and myocardial contrast echocardiography (MCE) are novel imaging techniques. The purpose of this study was to confirm the feasibility and accuracy of RT3DE combined with MCE for quantitative evaluation of myocardial perfusion defects. Methods Thirteen dogs underwent ligation of the left anterior descending artery (LAD, n=6) or distal branch of the left circumflex artery (LCX, n=7) under general anaesthesia. Three to four ml of a perfluoropropane (C 3F 8) microbubble contrast agent was injected intravenously to assess the resulting myocardial perfusion defects with a commercially available Philips SONOS-7500 ultrasound system. After removal of the dog hearts, Evans blue dye was injected via the left and righ t coronary arteries to stain the myocardium at risk. In vitro anatomic measurements of myocardial mass after removal of the animals’ hearts were used as control s. Results Left ventricular (LV) mass determined by RT3DE ranged 36.7-68.9 g [mean, (54.6±9.6) g] before coronary artery ligation, and correlated highly (r=0.99) with in vitro measurement of LV mass [range, 38.9-71.1 g; mean, (55.6±9.3) g]. There was no significant difference between RT3DE and in vitro measurements of LV mass [range, 36.7-68.9 g; mean, (51.3±12.5) g. Or range, 38.9-71. 1 g; mean, (53.7±12.3) g, respectively] and under-perfused mass [range, 0-21.4 g; mean, (12.0±6.9) g. Or range, 0-19.8 g; mean, (10.8±6.3) g, respectively] after th e LAD ligation (P>0.05). Likewise, no significant difference was present between RT3DE and in vitro measurements of LV mass [range, 50.1-65.4 g; mean, (57.5±5.9 ) g. Or range, 51.5-65.8 g; mean, (57.3±6.4) g, respectively] and under-perfused m ass [range, 0-25.6 g; mean, (13.3±9.6) g. Or range, 0-22.7 g; mean, (12.8±8.1 ) g, respectively] after the LCX ligation (P>0.05). For all the animals with coronary ligation, LV mass measured by RT3DE ranged 35.9-68.6 g [mean, (54.8±10.0) g] a nd there was no significant difference between RT3DE and in vitro measurements of LV mass and under-perfused mass (P>0.05, r=0.99). Further, the under-perfused mass derived from RT3DE [range, 0-25.6 g; mean, (12.7±8.2) g] correlate d strongly with the in vitro measurements [range, 0-22.7 g; mean, (11.9±7.2) g] ( r=0.96). Conclusion RT3DE with MCE is a rapid and accurate method for estimating LV myocardial mass and quantifying perfusion defects.