期刊文献+
共找到1,840篇文章
< 1 2 92 >
每页显示 20 50 100
Clinical Effect Analysis of Posterior Chamber Intraocular Lens Implantation for Correcting High Myopia and Astigmatism
1
作者 Bo Xia Dan Dan Zhao 《Journal of Clinical and Nursing Research》 2024年第8期99-104,共6页
Objective:To explore the corrective effect of posterior chamber intraocular lens implantation with phakic eyes in the treatment of high myopia and astigmatism.Methods:From May 2023,the hospital began to collect the ca... Objective:To explore the corrective effect of posterior chamber intraocular lens implantation with phakic eyes in the treatment of high myopia and astigmatism.Methods:From May 2023,the hospital began to collect the case data of diagnosis and treatment of high myopia and astigmatism.By May 2024,310 cases were included,all of which were treated with posterior chamber intraocular lens implantation.The visual acuity,astigmatism and axial position of the intraocular lens were observed before and after treatment.Results:At different time points after the operation,the patient’s vision was significantly improved compared with that before the operation(P<0.05),and the vision level was equal to or greater than the best-corrected vision before the operation.At different time points after the operation,the average rotation of the intraocular lens was less than 5 degrees.Astigmatism was significantly lower than that before the operation(P<0.05).After the operation,the intraocular pressure increased in 11 cases,accounting for 3.55%,with no adverse complications such as lens turbidity,glare and obvious halo occurring.Conclusion:The posterior chamber intraocular lens implantation with phakic eyes has an ideal correction effect in the treatment of high myopia and astigmatism,which can effectively improve the vision level of patients and reduce the degree of astigmatism,and has high effectiveness and safety. 展开更多
关键词 Posterior chamber intraocular lens implantation in phakic eyes High myopia ASTIGMATISM Corrective effect
下载PDF
Effect of capsule treatment on visual acuity and quality after phacoemulsification lens implantation in myopic patients with cataract
2
作者 Wei Liu Qi Liu +2 位作者 Fang Zhou Bo Feng Wan-Ling Wu 《World Journal of Clinical Cases》 SCIE 2024年第19期3882-3889,共8页
BACKGROUND Cataracts pose a significant clinical burden due to their complex pathogenesis.In recent years,an increase in cataracts coexisting with myopia has heightened the incidence of retinopathy and posterior vitre... BACKGROUND Cataracts pose a significant clinical burden due to their complex pathogenesis.In recent years,an increase in cataracts coexisting with myopia has heightened the incidence of retinopathy and posterior vitreous detachment.Additionally,symptoms of ocular axis elongation,lens nucleus hardening,and vitreous liquefaction have become more prevalent.While conventional extracapsular cataract extraction is commonly employed,it often yields suboptimal visual outcomes.Subsequent advancements in cataract phacoemulsification and lens implantation surgeries have gained widespread acceptance for their ability to improve refraction and significantly improve uncorrected visual acuity.AIM To investigate the effect of capsular treatment after phacoemulsification lens implantation in myopic patients with cataract.METHODS We selected 110 patients(with 134 eyes)with myopia and cataracts treated.These patients were categorized into two groups:an observation group(57 patients with 70 eyes)and a control group(53 patients with 64 eyes).The control group underwent cataract phacoemulsification and lens implantation,while the observation group received a refined capsular treatment based on the control group’s procedure.We assessed the differences in visual acuity and quality between the two groups before and after surgery.RESULTS At six months post-operation,the observation group exhibited significantly improved far vision,intermediate vision,near vision,lower objective scattering index,higher Modulation transfer function cut-off frequency,and overall vision metrics at different contrast levels(100%,20%and 9%)compared to the control group(P<0.05).The total score of the National Eye Institute Visual Function Questionnaire in the observation group at 6 months after operation was significantly higher than that in the control group(P<0.05).No significant difference in the incidence of adverse reactions was observed between the observation group and control group(P>0.05).CONCLUSION Capsular treatment demonstrates efficacy in improving visual acuity and quality after phacoemulsification lens implantation in myopic patients with cataracts,warranting its clinical application. 展开更多
关键词 Capsular treatment myopia CATARACT Phacoemulsification and lens implantation Visual acuity Visual quality Uncorrected visual acuity
下载PDF
Long-term observation on safety and visual quality of implantable collamer lens V4c implantation for myopia correction:a 5-year follow-up 被引量:4
3
作者 Xiao Chen Li Li +4 位作者 Jing Rao Yue-Xi Chen Yang Gao Rui-Xue Huang Qi-Zhi Zhou 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第7期1123-1129,共7页
AIM:To elucidate the safety and visual quality of implantable collamer lens with central hole(ICL V4c)implantation for correcting moderate and high myopia for at least 5y.METHODS:This retrospective study was conducted... AIM:To elucidate the safety and visual quality of implantable collamer lens with central hole(ICL V4c)implantation for correcting moderate and high myopia for at least 5y.METHODS:This retrospective study was conducted on 58 patients(114 eyes)who were followed up for at least 5y after ICL V4c implantation.The observation was done before and on 1d,1mo,1 and 5y or more after the surgical procedure.The visual acuity,subjective refraction,intraocular pressure,vault,axial length,central hole position,pupil diameter,visual quality,and adverse events were analyzed.The visual quality includes aberration,the modulation transfer function cutoff frequency(MTF cutoff),objective scattering index(OSI),Stroller's ratio(SR),and visual quality questionnaire.RESULTS:The average follow-up period was 69.25±3.80mo(range 60–82mo)and the preoperative spherical equivalent(SE)was-8.66±1.97 D.At 5y after operation,the safety index was 1.01±0.02 and the efficacy index was 0.99±0.42 and SE was-0.65±0.63 D.The 59.6%of the eyes achieved an uncorrected distance visual acuity of 20/20,76.3%of the eyes had SE within±1.0 D at the last visit.The axial length increased by 0.29±0.71 mm 5y after the surgery(t=-3.843,P<0.001).The mean vault at the last follow-up was 510.59±245.61μm.The central hole was on the temporal side in 80 eyes(84.2%).The visual quality questionnaire showed that 98.2%patients were satisfied with the surgical procedure.Adverse events occurred in 4 eyes(3.5%),including the posttraumatic toric ICL rotation(2 eyes),iris incarceration(1 eye),and posttraumatic ICL displacement(1 eye)at the last follow-up.CONCLUSION:Long-term ICL V4c implantation is safe,effective,and stable for correcting moderate and to high myopia,and the visual quality with patients is excellent and satisfactory,but the progression of axial length still needs attention after surgery. 展开更多
关键词 implantable collamer lens with central hole myopia correction refractive surgery visual quality
下载PDF
Early clinical outcome with lens position adjustment following implantable collamer lens surgery
4
作者 Qian Zhang Bo Zhao +2 位作者 Xue-Fei Yang Zhang-Lin Liu Yue Huang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第9期1654-1658,共5页
AIM:To observe early clinical outcome with lens position adjustment following the implantable collamer lens(ICL)surgery.METHODS:Sixty patients were selected for this retrospective study.One eye from each patient recei... AIM:To observe early clinical outcome with lens position adjustment following the implantable collamer lens(ICL)surgery.METHODS:Sixty patients were selected for this retrospective study.One eye from each patient received Toric ICL for astigmatism correction,and the other received non-astigmatic ICL surgery using horizontal position.Patients with higher postoperative arch height were selected,and their non-astigmatic eye clinical outcome were observed after ICL surgery at 1wk,1,and 3mo.The clinical measurements included uncorrected visual acuity(UCVA),intraocular pressure(IOP),refractive state,corneal endothelium cell count,and arch height.Three months later,the ICL in each patient’s non-astigmatic eye was adjusted to the vertical from the horizontal position.The results were compared before and 1wk,1,and 3mo after adjustment.RESULTS:UCVA and IOP were significantly reduced 1wk after position adjustment compared to 1wk after ICL implantation(P<0.05).The patients demonstrated significantly reduced arch height and corneal endothelium cell count 1wk,1,and 3mo after adjusting position compared to 1wk,1,and 3mo after ICL implantation(P<0.05).However,there was no significant difference in refraction between 1wk,1,and 3mo after ICL implantation and position adjustment(P>0.05).CONCLUSION:Early positioning adjustment postphakic ICL implantation can benefit patients with adjusted arch height or higher IOP.Despite the good clinical effects,the doctors should pay attention to the potential for adverse effects on UCVA and corneal endothelium cells following early position adjustment after posterior chamber phakic ICL implantation. 展开更多
关键词 implantable collamer lens myopia lens positional adjustment arch height intraocular pressure
下载PDF
Long-term vision-threatening complications of phakic intraocular lens implantation for high myopia 被引量:14
5
作者 Isil Bahar Sayman Muslubas Baran Kandemir +2 位作者 Ayse Yesim Aydin Oral Suleyman Kugu Metin Dastan 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2014年第2期376-380,共5页
AIMTo report the long-term vision-threatening complications in patients who underwent phakic intraocular lens (pIOLs) implantation for high myopia.
关键词 phakic intraocular lens high myopia COMPLICATIONS corneal decompensation rhegmatogenous retinal detachment
下载PDF
Rhegmatogenous retinal detachment in highly myopic eyes with implantable collamer lens
6
作者 Jun Li Chong-Lin Chen +2 位作者 Jia-Qing Li Xiao-Ling Liang Chun Zhang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第2期392-396,共5页
AIM:To investigate the clinical characteristics,treatment methods and outcomes of rhegmatogenous retinal detachment(RRD)in highly myopic eyes with implantable collamer lens(ICL).METHODS:High myopia patients who receiv... AIM:To investigate the clinical characteristics,treatment methods and outcomes of rhegmatogenous retinal detachment(RRD)in highly myopic eyes with implantable collamer lens(ICL).METHODS:High myopia patients who received treatment for nontraumatic RRD after ICL implantation surgery at the Retinal Department of Zhongshan Ophthalmic Center from Jan 2018 to Dec 2022 were reviewed.Comprehensive ophthalmologic examinations including visual acuity measurement and digital fundus photography were performed in each patient.RESULTS:A total of nine RRD eyes from nine patients who received V4c-ICL implantation were included.The mean time from ICL implantation surgery to the diagnosis of RRD was 32.44±22.56mo(range,1-60mo).At the initial visit for RRD,giant retinal tear(GRT),horseshoe tear,simple round hole,and horseshoe tear combined with round hole were detected in 3,3,2,and 1 eye(s),respectively,with maculaoff in eyes.Eight patients received surgical treatment,and one patient was treated by retinal laser photocoagulation alone.The ICL was preserved in 7 eyes.At the last followup,the mean best corrected visual acuity(BCVA)improved significantly from 1.76±1.06 logMAR at presentation to 0.81±1.01 logMAR(P=0.035),and no case of recurrent retinal detachment was found.CONCLUSION:The morphological presentation of retinal breaks is diverse in this study.The ICL can be preserved in most cases during the course of retinal detachment repair surgery in our data,companied with acceptable visual and anatomical outcomes. 展开更多
关键词 high myopia implantable collamer lens rhegmatogenous retinal detachment
下载PDF
Posterior chamber phakic intraocular lens implantation for high myopia 被引量:8
7
作者 Yan Ju Xiao-Wei Gao Bing Ren 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2013年第6期831-835,共5页
AIM:To evaluate the efficacy,safety and stability of posterior chamber phakic intraocular lens implantation for the correction of high myopia.METHODS:Retrospective case review of 82 eyes(43patients)undergoing implanta... AIM:To evaluate the efficacy,safety and stability of posterior chamber phakic intraocular lens implantation for the correction of high myopia.METHODS:Retrospective case review of 82 eyes(43patients)undergoing implantable Coliamer lens(ICL)placement by a single surgeon(Xiao-Wei Gao)to correct preoperative mean spherical equivalents between-9.00diopter(D)and-23.00D.Main outcome measures included uncorrected visual acuity(UCVA),refraction,best spectacle-corrected visual acuity(BSCVA),endothelial cell density(ECD),intraocular pressure(IOP),lens transparency,postoperative uveitis.Visante anterior segment optical coherence tomography(AS-OCT)was used to measure anterior chamber depth(ACD)and the position of ICL.RESULTS:Mean follow-up was 6.54±3.26 months(range 3-12 months).Predictability of the manifest spherical equivalent(SE)refraction to within±1.OOD was achieved in 88%of eyes and±0.50D in 72.5%of eyes.The mean postoperative manifest SE refraction was-1.85±0.72D,with 96.34%of eyes maintaining or gaining≥1 line(s)of BSCVA.The mean 3-month postoperative ECD decreased but had no statistically difference compared with the preoperative ECD.Of the 7 eyes(8.54%)with a mild transient increase in intraocular pressure(up to 30mmHg),none required a second surgical procedure or prolonged topical medication.There was no loss of lens transparency.Pigmented precipitates were observed in 5 eyes(6.09%).The mean preoperative ACD measured with AS-OCT was 3.28±0.14mm,three months after surgery,the mean ACD was2.45±0.22mm.Anterior chamber depth showed astatistically significant reduction.One eye(1.22%)had ICL spontaneous rotation,81 eyes(98.78%)of the lens remained correctly centered.CONCLUSION:The implantation of ICL is an effective surgical option for the management of high myopia.But its long time effect and safety still need more time to prove. 展开更多
关键词 phakic intraocular lens lens implantation myopia
下载PDF
Visual performance after implantation of two types of phakic foldable intraocular lenses for correction of high myopia 被引量:4
8
作者 Islam M.Rizk Abd-Almonem A.Al-hessy +1 位作者 Sherief E.El-Khouly Ashraf M.Sewelam 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2019年第2期284-290,共7页
AIM: To compare Visian lens(model V4 c) and Artiflex lens regarding quality(contrast sensitivity) and quantity(efficacy, predictability, safety and stability) of vision in correcting high myopia with recording and ana... AIM: To compare Visian lens(model V4 c) and Artiflex lens regarding quality(contrast sensitivity) and quantity(efficacy, predictability, safety and stability) of vision in correcting high myopia with recording and analysis of complications. METHODS: The comparative prospective study included 39 eyes of 23 patients with high myopia, 19 eyes had Visian lens implantation(model V4 c) and 20 eyes had Artiflex lens implantation. The inclusion criteria were high myopia(higher than 6.0 D) and stable refraction(<0.5 D change over one year). Outcomes included assessment of safety and efficacy indices, predictability, stability, contrast sensitivity and analysis of complications at postoperative 1 d, 1 wk and 1, 3, 6 and 12 mo. Selection of the type of phakic intraocular lens for patients was based on surgeons' preferences, which was no specific selection criteria. RESULTS: After 12 mo of follow up, difference in uncorrected and corrected distant visual acuity(CDVA) between both groups was statistically insignificant(UDVA for VisianV4 c and Artiflex lens were 0.33±0.2 logMAR and 0.37±0.2 logMAR respectively, P=0.59, CDVA for VisianV4 c and Artiflex lens were 0.155±0.1 logMAR and 0.147± 0.1 logMAR respectively, P=0.87). The efficacy index was 1.25 for VisianV4 c lens and 0.8 for Artiflex lens, 78.9% of eyes were within one diopter spherical equivalent in Visian V4 c lens group compared to 70% in the Artiflex lens group. No eye lost lines of CVDA proving a good safety index for both lenses(safety index was 1.67 for VisianV4 c lens and 1.34 for Artiflex lens). Difference in contrast sensitivity between both groups was statistically insignificant(P=0.15, 0.88, 0.27, 0.32 and 0.82 at five spatial frequencies). CONCLUSION: Both Visian ICL V4 c and Artiflex lensesare safe and effective with stable and predictable refraction and they have comparable contrast sensitivity outcomes with no vision threatening complications. 展开更多
关键词 PHAKIC intraocular lenses implantABLE collamer Visian V4c lens foldable Artiflex lens
下载PDF
Comparison of Visual Quality after Implantation of Big Bag and Akreos Adapt Intraocular Lenses in Patients with High Myopia 被引量:7
9
作者 Shengsheng Ma Dongjian Zheng +2 位作者 Ling Lin Fanjian Meng Yonggang Yuan 《Eye Science》 CAS 2015年第1期18-22,共5页
Purpose: To compare vision quality following phacoemulsification cataract extraction and implantation of a Big Bag or Akreos Adapt intraocular lens(IOL) in patients diagnosed with high myopia complicated with cataract... Purpose: To compare vision quality following phacoemulsification cataract extraction and implantation of a Big Bag or Akreos Adapt intraocular lens(IOL) in patients diagnosed with high myopia complicated with cataract.Methods:.This was a randomized prospective control study.The patients with high myopia complicated with cataract, with axial length ≥28 mm,.and corneal astigmatism ≤1D were enrolled and randomly divided into the Big Bag and Akreos Adapt IOL groups. All patients underwent phacoemulsification cataract extraction and lens implantation..At 3 months after surgery,.intraocular high-order aberration was measured by a Tracey-i Trace wavefront aberrometer at a pupil diameter of 5mm in an absolutely dark room and statistically compared between two groups. The images of the anterior segment of eyes were photographed with a Scheimpflug camera using Pentacam three-dimensional anterior segment analyzer..The tilt and decentration of the IOL were calculated by Image-pro plus 6.0imaging analysis software and statistically compared between two groups.Results:.In total,.127 patients(127 eyes),..including 52 males and 75 females, were enrolled in this study. The total high-order aberration and coma in the Akreos Adapt group(59 eyes)were significantly higher compared with those in the Big Bag(P <0.05)..The clover and spherical aberration did not differ between the two groups(P>0.05). The horizontal and vertical decentration were significantly smaller in the Big Bag lens group than in the Akreos Adapt group(both P<0.05), whereas the tilt of IOL did not significantly differ between the two groups(P>0.05).Conclusion:.Both Big Bag and Akreos Adapt IOLs possess relatively good intraocular stability implanted in patients with high myopia. Compared with the Akreos Adapt IOL, the Big Bag IOL presents with smaller intraocular high-order aberration. Coma is the major difference between the two groups. 展开更多
关键词 人工晶体 视觉质量 患者 大袋 近视 植入 体高 晶状
下载PDF
Full-vision maintenance in extra-high myopia from implantable collamer lens to trifocal intraocular lens implantation 被引量:2
10
作者 Shu-Yang Chen Chen Xie +1 位作者 Yang Wang Ye Shen 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2018年第7期1239-1242,共4页
Dear Editor,I am Dr.Ye Shen from the Department of Ophthalmology,the First Affiliated Hospital,College of Medicine,Zhejiang University,Hangzhou,China.I write to share my experience of full-vision maintenance in patien... Dear Editor,I am Dr.Ye Shen from the Department of Ophthalmology,the First Affiliated Hospital,College of Medicine,Zhejiang University,Hangzhou,China.I write to share my experience of full-vision maintenance in patient with extrahigh myopia from implantable collamer lens (ICL) to trifocal intraocular lens (IOL) implantation. 展开更多
关键词 ICL IOL Full-vision maintenance in extra-high myopia from implantable collamer lens to trifocal intraocular lens implantation
下载PDF
Postoperative efficacy,safety,predictability,and visual quality of implantable collamer lens implantation versus small incision lenticule extraction in myopic eyes:a Meta-analysis 被引量:4
11
作者 Hong-Yu Li Zi Ye Zhao-Hui Li 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第3期442-452,共11页
AIM:To compare the postoperative efficacy,safety,predictability,and visual quality of implantable collamer lens(ICL)implantation versus small incision lenticule extraction(SMILE)in myopia eyes.METHODS:Pub Med,EMBASE,W... AIM:To compare the postoperative efficacy,safety,predictability,and visual quality of implantable collamer lens(ICL)implantation versus small incision lenticule extraction(SMILE)in myopia eyes.METHODS:Pub Med,EMBASE,Web of Science,Cochrane Library and several Chinese databases were searched at May 2021 to select relevant studies in comparison of clinical outcomes between ICL implantation and SMILE for myopia.The primary outcomes were efficacy,safety,and predictability.And the secondary outcomes were postoperative higher-order ocular aberrations(HOAs),modulation transfer function cutoff frequency(MTF),objective scatter index(OSI),contrast sensitivity and a quality of vision(Qo V)questionnaire.RESULTS:A total of 1036 eyes from 10 studies,of which 503 eyes underwent ICL implantation and 533 eyes underwent SMILE,were enrolled in this Meta-analysis.Pooled results revealed that ICL group had a better safety index and post-corrected distance visual acuity(CDVA)(P=0.007,<0.00001,respectively),and a lower percentage of eyes with a postoperative CDVA lost 1 line(P=0.007)than the SMILE group.No significant differences were found in comparison of the other primary outcomes.In the longterm follow-up(>6mo),ICL group had a lower total HOA,coma,and spherical aberration than SMILE group(P=0.003,<0.00001,0.04).Yet higher trefoil was found in ICL group at 6mo after surgery(P=0.003).Additionally,ICL group also had a higher MTF value(P=0.02),and a higher contrast sensitivity score for spatial frequencies of 1.5,6,and 12 cpds(P=0.02,0.005,0.02,respectively).And it also had a lower score of bothersome in Qo V questionnaire than SMILE group(P=0.003).CONCLUSION:ICL implantation and SMILE have similar and comparable outcomes in term of the efficacy and predictability for correcting high myopia.However,ICL group is relatively safer and also has better visual quality in comparison of SMILE group. 展开更多
关键词 implantable collamer lens small incision lenticule extraction myopia refractive surgery META-ANALYSIS
下载PDF
Rhegmatogenous retinal detachment after intraocular lens implantation in high myopia:A case report and literature review
12
作者 Shu-Yu Fu Xiong-Gao Huang 《Journal of Hainan Medical University》 2022年第1期64-67,共4页
Objective:To observe the changes of diagnosis and treatment of a patient with rhegmatogenous retinal detachment(RRD)after phakic intraocular lens implantation in high myopia,and analyze its mechanism and treatment com... Objective:To observe the changes of diagnosis and treatment of a patient with rhegmatogenous retinal detachment(RRD)after phakic intraocular lens implantation in high myopia,and analyze its mechanism and treatment combined with the literature.Methods:To report a case of rhegmatogenous retinal detachment(RRD)after phakic intraocular lens implantation.Result:Two months after the patient underwent scleral cerclage+pad pressing+vitrectomy+silicone oil filling,the fundus color photos showed that the vitreous cavity was filled with silicone oil,the fundus retina was flat,the cerclage ridge was obvious,and a large number of old laser spots.After the silicone oil in the eye was removed,the eye examination:the naked visual acuity of the left eye was 0.12,the corrected visual acuity was-3.25ds/-1.50dc*180=0.4,the intraocular pressure was 19mmHg,the ring ridge was seen in the fundus after mydriasis,a large number of old laser spots and flat retina;The OCT showed that the macular structure of the left eye was complete and there was no subretinal fluid.Conclusion:Scleral cerclage+padding+vitrectomy+silicone oil filling is an effective treatment for retinal detachment(RD)after PIOL. 展开更多
关键词 Phakic intraocular lens implantation Rhegmatogenous retinal detachment VITRECTOMY
下载PDF
Outcomes of secondary sulcus intraocular lens implantation in unilateral anterior persistent fetal vasculature 被引量:3
13
作者 Jing-Hua Liu Song-Feng Li +2 位作者 Guang-Da Deng Yong-Hong Jiao Hai Lu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2019年第4期592-596,共5页
AIM: To evaluate the surgical results of sulcus intraocular lens(IOL) implantation in children with unilateral anterior persistent fetal vasculature(PFV) underwent primary vitrectomy combined with lensectomy and prese... AIM: To evaluate the surgical results of sulcus intraocular lens(IOL) implantation in children with unilateral anterior persistent fetal vasculature(PFV) underwent primary vitrectomy combined with lensectomy and preservation of the peripheral anterior capsule.METHODS: Twenty-two eyes of 22 children with unilateral anterior PFV who underwent sulcus secondary IOL implantation were analyzed. Main outcome measures were preoperative and postoperative visual acuity, and complications both intraoperatively and postoperatively. RESULTS: Review of 22 consecutive patients identified best-corrected visual acuity(BCVA) improvement from 1.37±0.84 to 0.73±0.57 logarithm of the minimal angle of resolution(logMAR) after IOL implantation(P<0.001) with a mean follow-up was 16.55±5.86 mo. Average age at secondary IOL implantation was 41.05±15.41 mo. Three eyes(13.64%) achieved BCVA of 0.3 logMAR at the final visit. Transient intraocular pressure rise(4 eyes; 18.18%), postoperative increased inflammation(3 eyes; 13.64%) and postoperative hypotony(2 eyes; 9.09%) were common complications.CONCLUSION: Properly preservation of the anterior lens capsule during the primary surgery facilitated secondary sulcus IOL implantation in pediatric patients with anterior PFV, with favorable postoperative visual outcomes and compatible percentage of complications. 展开更多
关键词 SECONDARY SULCUS intraocular lens implantation SULCUS PERSISTENT FETAL VASCULATURE
下载PDF
Diffractive multifocal intraocular lens implantation in patients with monofocal intraocular lens in the contralateral eye 被引量:6
14
作者 Jae Yong Kim Yunhan Lee +4 位作者 Hun Jae Won Hyerin Jeong Jin Hyoung Park Myoung Joon Kim Hungwon Tchah 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2020年第5期737-743,共7页
AIM:To evaluate clinical outcomes of unilateral implantation of a diffractive multifocal intraocular lens(IOL)in patients with contralateral monofocal IOL.METHODS:Twenty-two patients who already had implantation of a ... AIM:To evaluate clinical outcomes of unilateral implantation of a diffractive multifocal intraocular lens(IOL)in patients with contralateral monofocal IOL.METHODS:Twenty-two patients who already had implantation of a monofocal IOL in unilateral eye underwent implantation of a diffractive multifocal IOL in contralateral eye were enrolled.After 1,6,and 12 mo,uncorrected and distant corrected distant visual acuity(UCDVA and DCDVA),uncorrected and distant corrected intermediate-visual acuity(UCIVA and DCIVA),uncorrected and distant corrected near visual acuity(UCNVA and DCNVA),and contrast sensitivity were obtained.Halo/glare symptoms,spectacle dependence,and patient satisfaction were also evaluated.RESULTS:The mean age was 67.86±7.25 y and the average interval between two IOL implantations was 645.82±878.44 d.At 1 mo,binocular UCDVA was lower than 0.20 logMAR in 76%of patients(mean 0.12±0.13 logMAR),which increased to 90%by 6 and 12 mo.The binocular UCDVA was significantly better than the monocular results(P<0.05)at 1,6,and 12 mo.Additionally,UCNVA was lower than 0.40 logMAR in 82%of patients,increasing to 90%by 6 and 12 mo.Mean UCNVA in the multifocal IOL implanted eye was statistically significantly better than that in the monofocal IOL implanted eye(P<0.05)at 1,6,and 12 mo.About 5%of patients at 1 and 6 mo,reported"severe glare or halo".Patient satisfaction rates were 95%and 91%at 6 and 12 mo,respectively.CONCLUSION:Unilateral implantation of multifocal IOL in patients with a contralateral,monofocal IOL implantation results in high patient satisfaction rate,with low severe glare or halo rate during follow-up.It can represent a good option for patients who have previously had a monofocal IOL implantation regardless of two year interval duration between two IOL implantations. 展开更多
关键词 diffractive multifocal intraocular lens unilateral implantation near vision cataract surgery
下载PDF
Short and long-term outcomes of angle supported phakic intraocular lens implantation in high myopic eyes 被引量:2
15
作者 Saeed Al-Qahtani Khalid Al-Afraj +2 位作者 Mohanna Al-Jindan Ali S Al-Beshri Rajiv KhANDekar 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2018年第5期888-890,共3页
This cohort study included 36 eyes of 21 patients with high myopia treated with angle supported phakic intraocular lens(p IOL).Endothelial cell density(ECD) at baseline,6 mo and 3 y were 3017±296,2775±26... This cohort study included 36 eyes of 21 patients with high myopia treated with angle supported phakic intraocular lens(p IOL).Endothelial cell density(ECD) at baseline,6 mo and 3 y were 3017±296,2775±265 and 2558±299 cells/mm^2 respectively.ECD loss at 6 mo was 7.2% and annual ECD loss was 3% over 36 mo.Corrected distance visual acuity at 36 mo was 0.4 log MAR or better in 32(88.9%) eyes.Intraocular pressure did not change(P=0.9).No eyes developed cataract,retinal detachment or pupillary distortion.Angle supported p IOL gives good visual outcome.Endothelial cell loss should be monitored. 展开更多
关键词 phakic intraocular lens high myopia refractive surgery
下载PDF
Trocar opening: silicone oil removal with phacoemulsification and intraocular lens implantation 被引量:1
16
作者 Xu Zhang Ya-Jie Pan Zheng-Yu Song 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2019年第11期1720-1724,共5页
AIM: To evaluate the efficacy and safety of a modified technique [trocar opening(TO)] for silicone oil removal(SOR) in combination with phacoemulsification and intraocular lens(IOL) implantation.METHODS: A total of 60... AIM: To evaluate the efficacy and safety of a modified technique [trocar opening(TO)] for silicone oil removal(SOR) in combination with phacoemulsification and intraocular lens(IOL) implantation.METHODS: A total of 60 eyes of 60 patients with cataract and silicone oil-filled eyes were enrolled in this study. The patients were divided into two groups: the patients in the control group underwent 23-gauge pars plana active SOR surgery with phacoemulsification and IOL implantation, while the patients in the TO group underwent TO methods during surgery. Best corrected visual acuity(BCVA), surgery time, intraocular pressure, and operative complications were observed 6 mo after surgery.RESULTS: There was no significant difference between the two groups in terms of age, gender, preoperative, intraocular pressure, or time of silicone oil stay. Prior to surgery, the mean BCVA for the control and TO groups was 1.34±0.44 and 1.36±0.42. At 6 mo following surgery, the mean BCVA improved to 0.74±0.36 and 0.77±0.32, respectively(P<0.001). There was no significant difference between the two groups. The mean SOR time was 6.9±2.3 min and 4.8±1.2 min in the control and TO groups(P=0.008). The total operation time was 28.2±8.5 min and 24.6±6.4 min, respectively(P=0.035). Posterior capsule rupture occurred in four eyes of control and none of TO group(P<0.01). Late recurrent retinal detachment occurred in one eye in the control group(2 mo after surgery) and in one eye in the TO group(4 mo after surgery). CONCLUSION: TO is a simple, effective, time-saving, and safe method for SOR combined with phacoemulsification and IOL implantation. 展开更多
关键词 intraocular lens implantation PHACOEMULSIFICATION POSTERIOR CAPSULE rupture SILICONE oil removal
下载PDF
Commentary review:challenges of intraocular lens implantation for congenital cataract infants 被引量:1
17
作者 Qi-Hui Zhao Yun-E Zhao 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2021年第6期923-930,共8页
As an indispensable part of congenital cataract surgery,intraocular lens(IOL)implantation in infantile patients has long-term positive impacts on visual rehabilitation,as well as postoperative complications inevitably... As an indispensable part of congenital cataract surgery,intraocular lens(IOL)implantation in infantile patients has long-term positive impacts on visual rehabilitation,as well as postoperative complications inevitably.Timing of IOL implantation in infantile congenital cataract patients is not simply a point-in-time but a personalized decision that comprehensively takes age at surgery,risks of postoperative complications,and economic condition of family in consideration,and combines with choosing suitable IOL type and power.For infants with well-developed eyeballs and good systemic conditions,IOL implantation at six months of age or older is safe and effective.Otherwise,secondary IOL implantation may be a safer choice. 展开更多
关键词 timing of surgery intraocular lens implantation congenital cataract INFANTS
下载PDF
Using Topical Anesthesia for Standing Phacoemulsification Cataract Surgery and Intraocular Lens Implantation 被引量:1
18
作者 Ronghan Wu Qinxiang Zheng Wensheng Li 《Surgical Science》 2012年第5期279-281,共3页
Introduction: To report by using topical anesthesia for standing phacoemulsification and intraocular lens implantation for two patients who need cataract extraction but unable to lie flat with marked cervical kyphosis... Introduction: To report by using topical anesthesia for standing phacoemulsification and intraocular lens implantation for two patients who need cataract extraction but unable to lie flat with marked cervical kyphosis due to long-standing ankylosing spondylitis and chronic uveitis. Methods: Two patients are unable to lie flat respectively during phacoemulsification underwent this technique in Jingdong and Tonghai county Hospital of Yunnan province in China. Each patient was positioned erect or semirecumbent in a standard reclining cataract surgical chair. The ceiling-mounted microscope was rotated 60 degrees from the vertical to point toward the patient. Results: The intraoperative and postoperative periods were uneventful in two patients, with good visual outcomes after surgery. Conclusion: This technique is valuable for situations where the patient requires upright positioning because of the inability to recline flat, and should be considered for cases where standard surgical positioning is not possible. 展开更多
关键词 TOPICAL ANESTHESIA CATARACT Surgery intraocular lens implantation
下载PDF
Bimanual microincision cataract surgery with implantation of the new Incise~? MJ14 intraocular lens through a 1.4 mm incision 被引量:2
19
作者 Gian Maria Cavallini Tommaso Verdina +5 位作者 Michele De Maria Elisa Fornasari Giulio Torlai Veronica Volante Simone Donati Carlo Cagini 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第11期1710-1715,共6页
AIM:To analyze the visual outcomes and the posterior capsule opacification(PCO)with the new Incise?MJ14intraocular lens(IOL)implanted through a 1.4 mm clear corneal incision(CCI)in patients who underwent biman... AIM:To analyze the visual outcomes and the posterior capsule opacification(PCO)with the new Incise?MJ14intraocular lens(IOL)implanted through a 1.4 mm clear corneal incision(CCI)in patients who underwent bimanual microincision cataract surgery(B-MICS).METHODS:Eighty eyes which underwent cataract surgery using B-MICS technique performed by the same experienced surgeon were included in the study:40 eyes were implanted with an Incise?MJ14 IOL through a 1.4 mm CCI(group A)without enlargement of the main CCI,while 40 eyes were implanted with an Akreos?MI60 IOL with enlargement of the main CCI to 1.8 mm(group B).Best corrected visual acuity(BCVA),astigmatism and endothelial cell loss were evaluated before and after surgery at 7,30d and 6mo.Anterior segment-optical coherence tomography(AS-OCT)of CCI was performed at 1,3,7,30d,6 and 18mo.PCO incidence was evaluated at 18mo using EPCO 2000 Software.RESULTS:Mean BCVA improvement and endothelial cell loss were statistically significant at 18mo in both groups with no difference between the two groups;no statistically significant difference in surgically induced astigmatism(SIA)was noticed in the two groups.At AS-OCT the only significant alterations in the CCI were endothelial gaping and local detachment of Descemet’s membrane at 1 and 7d after surgery;no statistically significant alterations were found at 1,6 and 18mo.PCO score at 18mo was 0.03±0.07for group A and 0.08±0.18 for group B(P=0.11)with no sign of central optic plate invasion in both groups.CONCLUSION:The implant of the new Incise?MJ14 IOL through a 1.4 mm CCI and B-MICS technique appeared to be a safe and effective procedure with rapid visual recovery.PCO rate resulted very low and the CCI presented few morphological alterations which were only detectable in the first days postoperatively and achieved fast corneal healing during the long-term follow-up. 展开更多
关键词 CCI In De Bimanual microincision cataract surgery with implantation of the new Incise MJ14 intraocular lens through a 1.4 mm incision
下载PDF
The morphological changes of cellson the surface of F-heparin surface modified intraocularlenses after implantation in the rabbits’eyes 被引量:3
20
作者 SUNHui-min GUOHong-yu +3 位作者 XUYan-shan YUANJia-qin GUHan-qing LUMo-zhu 《Chinese Journal of Biomedical Engineering(English Edition)》 2000年第1期38-43,共6页
After intraocular implantation of F ion-heparin surface modified intraocular lenses(FHSM IOLs) in the rabbits’eyes,there were small cells on the surfaces of IOLs accompanied by fibrinous exudates in the early days.Th... After intraocular implantation of F ion-heparin surface modified intraocular lenses(FHSM IOLs) in the rabbits’eyes,there were small cells on the surfaces of IOLs accompanied by fibrinous exudates in the early days.The cells included macrophages,fibroblast like cells,epithelioid cells,small foreign body giant cells and lymphocytes.As time went on it showed increasing variation of cell size and fusion of cells.At last the surface of IOLs were covered by a thin and transparent membrane chiefly made by degenerated cells and fibrins,and then the IOLs were well tolerated in the eyes. 展开更多
关键词 implantation intraocular lens F ION HEPARIN
下载PDF
上一页 1 2 92 下一页 到第
使用帮助 返回顶部