期刊文献+
共找到207篇文章
< 1 2 11 >
每页显示 20 50 100
Standard-definition White-light,High-definition White-light versus Narrow-band Imaging Endoscopy for Detecting Colorectal Adenomas:A Multicenter Randomized Controlled Trial
1
作者 Chang-wei DUAN Hui-hong ZHAI +10 位作者 Hui XIE Xian-zong MA Dong-liang YU Lang YANG Xin WANG Yu-fen TANG Jie ZHANG Hui SU Jian-qiu SHENG Jun-feng XU Peng JIN 《Current Medical Science》 SCIE CAS 2024年第3期554-560,共7页
Objective This study aimed to compare the performance of standard-definition white-light endoscopy(SD-WL),high-definition white-light endoscopy(HD-WL),and high-definition narrow-band imaging(HD-NBI)in detecting colore... Objective This study aimed to compare the performance of standard-definition white-light endoscopy(SD-WL),high-definition white-light endoscopy(HD-WL),and high-definition narrow-band imaging(HD-NBI)in detecting colorectal lesions in the Chinese population.Methods This was a multicenter,single-blind,randomized,controlled trial with a non-inferiority design.Patients undergoing endoscopy for physical examination,screening,and surveillance were enrolled from July 2017 to December 2020.The primary outcome measure was the adenoma detection rate(ADR),defined as the proportion of patients with at least one adenoma detected.The associated factors for detecting adenomas were assessed using univariate and multivariate logistic regression.Results Out of 653 eligible patients enrolled,data from 596 patients were analyzed.The ADRs were 34.5%in the SD-WL group,33.5%in the HD-WL group,and 37.5%in the HD-NBI group(P=0.72).The advanced neoplasm detection rates(ANDRs)in the three arms were 17.1%,15.5%,and 10.4%(P=0.17).No significant differences were found between the SD group and HD group regarding ADR or ANDR(ADR:34.5%vs.35.6%,P=0.79;ANDR:17.1%vs.13.0%,P=0.16,respectively).Similar results were observed between the HD-WL group and HD-NBI group(ADR:33.5%vs.37.7%,P=0.45;ANDR:15.5%vs.10.4%,P=0.18,respectively).In the univariate and multivariate logistic regression analyses,neither HD-WL nor HD-NBI led to a significant difference in overall adenoma detection compared to SD-WL(HD-WL:OR 0.91,P=0.69;HD-NBI:OR 1.15,P=0.80).Conclusion HD-NBI and HD-WL are comparable to SD-WL for overall adenoma detection among Chinese outpatients.It can be concluded that HD-NBI or HD-WL is not superior to SD-WL,but more effective instruction may be needed to guide the selection of different endoscopic methods in the future.Our study’s conclusions may aid in the efficient allocation and utilization of limited colonoscopy resources,especially advanced imaging technologies. 展开更多
关键词 standard-definition white-light endoscopy high-definition white-light endoscopy narrow-band imaging colonoscopy colorectal cancer screening adenoma detection rate
下载PDF
Could near focus endoscopy,narrow-band imaging,and acetic acid improve the visualization of microscopic features of stomach mucosa?
2
作者 Admir Kurtcehajic Enver Zerem +5 位作者 Tomislav Bokun Ervin Alibegovic Suad Kunosic Ahmed Hujdurovic Amir Tursunovic Kenana Ljuca 《World Journal of Gastrointestinal Endoscopy》 2024年第3期157-167,共11页
BACKGROUND Conventional magnifying endoscopy with narrow-band imaging(NBI)observation of the gastric body mucosa shows dominant patterns in relation to the regular arrangement of collecting venules,subepithelial capil... BACKGROUND Conventional magnifying endoscopy with narrow-band imaging(NBI)observation of the gastric body mucosa shows dominant patterns in relation to the regular arrangement of collecting venules,subepithelial capillary network,and gastric pits.AIM To evaluate the effectiveness of a new one-dual(near)focus,NBI mode in the assessment of the microscopic features of gastric body mucosa compared to conventional magnification.METHODS During 2021 and 2022,68 patients underwent proximal gastrointestinal endoscopy using magnification endoscopic modalities subsequently applying acetic acid(AA).The GIF-190HQ series NBI system with dual focus capability was used for the investigation of gastric mucosa.At the time of the endoscopy,the gastric body mucosa of all enrolled patients was photographed using the white light endoscopy(WLE),near focus(NF),NF-NBI,AA-NF,and AA-NF-NBI modes.RESULTS The WLE,NF and NF-NBI endoscopic modes for all patients(204 images)were classified in the same order into three groups.Two images from each patient for the AA-NF and AA-NF-NBI endoscopic modes were classified in the same order.According to all three observers who completed the work independently,NF magnification was significantly superior to WLE(P<0.01),and the NF-NBI mode was significantly superior to NF magnification(P<0.01).After applying AA,the three observers confirmed that AA-NF-NBI was significantly superior to AA-NF(P<0.01).Interobserver kappa values for WLE were 0.609,0.704,and 0.598,respectively and were 0.600,0.721,and 0.637,respectively,for NF magnification.For the NF-NBI mode,the values were 0.378,0.471,and 0.553,respectively.For AA-NF,they were 0.453,0.603,and 0.480,respectively,and for AA-NF-NBI,they were 0.643,0.506,and 0.354,respectively.CONCLUSION When investigating gastric mucosa in microscopic detail,NF-NBI was the most powerful endoscopic mode for assessing regular arrangement of collecting venules,subepithelial capillary network,and gastric pits among the five endoscopic modalities investigated in this study.AA-NF-NBI was the most powerful endoscopic mode for analyzing crypt opening and intervening part. 展开更多
关键词 Gastric mucosa Endoscopic microanatomy Magnifying endoscopy Near focus narrow-band imaging Acetic acid
下载PDF
LNB改造后燃烧器烧损及NO_x排放高原因分析 被引量:3
3
作者 陆军 徐党旗 +3 位作者 张广才 聂剑平 周飞 薛宁 《中国电力》 CSCD 北大核心 2015年第8期116-120,共5页
以某电厂为例,一期1、2号锅炉在低氮燃烧器(low-NOxburner,LNB)改造后,燃烧器设备先后出现烧损问题,且1号炉NOx排放较2号炉高约100 mg/m3,危及锅炉运行安全及脱硝设备正常投运。针对上述问题,从改造方案、设备制造及运行方式等方面分析... 以某电厂为例,一期1、2号锅炉在低氮燃烧器(low-NOxburner,LNB)改造后,燃烧器设备先后出现烧损问题,且1号炉NOx排放较2号炉高约100 mg/m3,危及锅炉运行安全及脱硝设备正常投运。针对上述问题,从改造方案、设备制造及运行方式等方面分析了原因。发现:(1)2号炉改造设计没有考虑煤种变化,采用了常规稳燃措施,同时运行期间周界风开度小,导致燃烧器区域出现局部高温,燃烧器防磨陶瓷脱落引起煤粉堆积,并在一次风室内燃烧导致燃烧器烧损;(2)1号炉燃烧器制造过程中各喷口间空隙未按设计要求封堵,煤粉被负压回流带入燃烧器隔板堆积燃烧,导致燃烧器烧损。同时,喷口间隙未封堵造成燃烧器二次风漏风严重,降低了空气分级效果,导致NOx偏高。在原因分析的基础上,采取了相应改进措施。结果表明,改进措施有效解决了1、2号炉出现的问题,可为其他电厂类似问题的解决提供参考。 展开更多
关键词 lnb改造 改造方案 设备制造 运行方式 燃烧器烧损 NOX排放
下载PDF
基于模糊控制器的LNB温度控制系统 被引量:3
4
作者 訾斌 段宝岩 黄进 《计算机工程》 CAS CSCD 北大核心 2007年第1期230-232,235,共4页
针对低噪声功率放大器(LNB)温度控制系统非线性、大滞后、物理模型不精确等特性和对温度控制的要求,提出了一种带有自调整因子和比例积分校正环节的双模糊控制策略来实现温度控制,给出了DSP控制实现的具体方案。该双模糊控制器采用模糊... 针对低噪声功率放大器(LNB)温度控制系统非线性、大滞后、物理模型不精确等特性和对温度控制的要求,提出了一种带有自调整因子和比例积分校正环节的双模糊控制策略来实现温度控制,给出了DSP控制实现的具体方案。该双模糊控制器采用模糊推理完成两组控制器的平稳过渡。实验结果表明了该系统的控制效果优于常规PID控制器,满足LNB控制系统温度控制要求。 展开更多
关键词 双模糊控制 低噪声功率放大器 温度控制 DSP
下载PDF
基于LabVIEW的LNB自动测试站控制板的设计
5
作者 陆毅 陆旭明 《工矿自动化》 2009年第4期109-112,共4页
低噪声降频放大器LNB的性能直接关系到整个网络的质量,因此,对其性能的测试极其重要。文章介绍了一种基于LabVIEW的LNB自动测试站控制板的设计。该控制板以8255芯片为控制核心,通过检测传感器信号控制待测LNB的位置移动和信号切换,并以L... 低噪声降频放大器LNB的性能直接关系到整个网络的质量,因此,对其性能的测试极其重要。文章介绍了一种基于LabVIEW的LNB自动测试站控制板的设计。该控制板以8255芯片为控制核心,通过检测传感器信号控制待测LNB的位置移动和信号切换,并以LabVIEW为开发平台编写控制板驱动程序,同时模拟返回的定位结束信号。试运行结果表明,该控制板能够实现待测LNB的定位及信号切换,且能够实时显示待测LNB的定位情况。 展开更多
关键词 低噪声降频放大器 lnb 自动测试站 控制板 LABVIEW
下载PDF
LNB本振随环境的变化及应变措施 被引量:1
6
作者 赵守光 《中国有线电视》 2006年第5期449-453,共5页
卫星电视接收天线LNB的本振频率对于一定的接收系统在理论上是一个固定值,但实际上其值受到工作环境变化的影响会出现漂移;其次,由于所选用的LNB不同,本振频率与理论值的频偏不同。在实际的保障工作中,接收同一卫星信号,用不同的接收天... 卫星电视接收天线LNB的本振频率对于一定的接收系统在理论上是一个固定值,但实际上其值受到工作环境变化的影响会出现漂移;其次,由于所选用的LNB不同,本振频率与理论值的频偏不同。在实际的保障工作中,接收同一卫星信号,用不同的接收天线得到的中频不同,严重时会出现二者的频偏相差超过2 MHz,这样在更换备用天线时必须调整卫星电视解码器的参数设置。 展开更多
关键词 低噪声降频器(lnb) 本振频率 本振频率漂移 本振频偏
下载PDF
Endoscopic detection and diagnostic strategies for minute gastric cancer:A real-world observational study
7
作者 Xiao-Wei Ji Jie Lin +4 位作者 Yan-Ting Wang Jing-Jing Ruan Jing-Hong Xu Kai Song Jian-Shan Mao 《World Journal of Gastrointestinal Oncology》 SCIE 2024年第8期3529-3538,共10页
BACKGROUND Minute gastric cancers(MGCs)have a favorable prognosis,but they are too small to be detected by endoscopy,with a maximum diameter≤5 mm.AIM To explore endoscopic detection and diagnostic strategies for MGCs... BACKGROUND Minute gastric cancers(MGCs)have a favorable prognosis,but they are too small to be detected by endoscopy,with a maximum diameter≤5 mm.AIM To explore endoscopic detection and diagnostic strategies for MGCs.METHODS This was a real-world observational study.The endoscopic and clinicopathological parameters of 191 MGCs between January 2015 and December 2022 were retrospectively analyzed.Endoscopic discoverable opportunity and typical neoplastic features were emphatically reviewed.RESULTS All MGCs in our study were of a single pathological type,97.38%(186/191)of which were differentiated-type tumors.White light endoscopy(WLE)detected 84.29%(161/191)of MGCs,and the most common morphology of MGCs found by WLE was protruding.Narrow-band imaging(NBI)secondary observation detected 14.14%(27/191)of MGCs,and the most common morphology of MGCs found by NBI was flat.Another three MGCs were detected by indigo carmine third observation.If a well-demarcated border lesion exhibited a typical neoplastic color,such as yellowish-red or whitish under WLE and brownish under NBI,MGCs should be diagnosed.The proportion with high diagnostic confidence by magnifying endoscopy with NBI(ME-NBI)was significantly higher than the proportion with low diagnostic confidence and the only visible groups(94.19%>56.92%>32.50%,P<0.001).CONCLUSION WLE combined with NBI and indigo carmine are helpful for detection of MGCs.A clear demarcation line combined with a typical neoplastic color using nonmagnifying observation is sufficient for diagnosis of MGCs.MENBI improves the endoscopic diagnostic confidence of MGCs. 展开更多
关键词 Minute gastric cancer White light endoscopy narrow-band imaging endoscopy Indigo carmine Magnifying endoscopy DETECTION Diagnosis
下载PDF
LNB型燃煤(气)蒸汽锅炉的缺陷及操作对策
8
作者 高军林 李斌胜 《工业安全与环保》 2007年第6期46-47,共2页
分析了新型环保LNB型燃煤(气)蒸汽锅炉在使用时产生的事故原因,并提出相应的安全操作对策,对新型环保LNB型燃煤(气)蒸汽锅炉的安全操作具有一定的指导意义。
关键词 lnb型燃煤(气)蒸汽锅炉 事故 安全操作
下载PDF
Topic highlight on texture and color enhancement imaging in gastrointestinal diseases
9
作者 Osamu Toyoshima Toshihiro Nishizawa Keisuke Hata 《World Journal of Gastroenterology》 SCIE CAS 2024年第14期1934-1940,共7页
Olympus Corporation developed texture and color enhancement imaging(TXI)as a novel image-enhancing endoscopic technique.This topic highlights a series of hot-topic articles that investigated the efficacy of TXI for ga... Olympus Corporation developed texture and color enhancement imaging(TXI)as a novel image-enhancing endoscopic technique.This topic highlights a series of hot-topic articles that investigated the efficacy of TXI for gastrointestinal disease identification in the clinical setting.A randomized controlled trial demonstrated improvements in the colorectal adenoma detection rate(ADR)and the mean number of adenomas per procedure(MAP)of TXI compared with those of white-light imaging(WLI)observation(58.7%vs 42.7%,adjusted relative risk 1.35,95%CI:1.17-1.56;1.36 vs 0.89,adjusted incident risk ratio 1.48,95%CI:1.22-1.80,respectively).A cross-over study also showed that the colorectal MAP and ADR in TXI were higher than those in WLI(1.5 vs 1.0,adjusted odds ratio 1.4,95%CI:1.2-1.6;58.2%vs 46.8%,1.5,1.0-2.3,respectively).A randomized controlled trial demonstrated non-inferiority of TXI to narrow-band imaging in the colorectal mean number of adenomas and sessile serrated lesions per procedure(0.29 vs 0.30,difference for non-inferiority-0.01,95%CI:-0.10 to 0.08).A cohort study found that scoring for ulcerative colitis severity using TXI could predict relapse of ulcerative colitis.A cross-sectional study found that TXI improved the gastric cancer detection rate compared to WLI(0.71%vs 0.29%).A cross-sectional study revealed that the sensitivity and accuracy for active Helicobacter pylori gastritis in TXI were higher than those of WLI(69.2%vs 52.5%and 85.3%vs 78.7%,res-pectively).In conclusion,TXI can improve gastrointestinal lesion detection and qualitative diagnosis.Therefore,further studies on the efficacy of TXI in clinical practice are required. 展开更多
关键词 Endoscopy Texture and color enhancement imaging White-light imaging narrow-band imaging Colorectal neoplasm Gastric cancer Adenoma Ulcerative colitis Helicobacter infections Colonoscopy
下载PDF
卫星电视接收机LNB中采用介质谐振器稳频的FET振荡器
10
作者 万云芳 冯祝 《中国有线电视》 北大核心 2004年第15期75-76,共2页
关键词 卫星电视接收机 lnb 介质谐振器 稳频 FET振荡器
下载PDF
LNB本振频率偏移的校正
11
作者 华兴潮 李悦科 《中国有线电视》 北大核心 2003年第21期102-103,共2页
关键词 数字卫星电视接收系统 lnb本振 频率偏移 校正方法
下载PDF
LNB型煤气化燃烧锅炉操作事故原因分析及预防方法探讨
12
作者 高军林 许雅周 《工业锅炉》 2007年第2期55-57,共3页
总结分析了LNB型煤气化燃烧锅炉在使用时产生事故的原因,并提出相应的安全操作对策。
关键词 lnb型煤气化燃烧锅炉 事故 安全操作
下载PDF
数字卫星接收机LNB损坏的常见原因及对策
13
作者 华兴潮 《中国有线电视》 北大核心 2004年第6期99-99,共1页
关键词 数字卫星接收机 lnb 高频头损坏 雷击 供电电压 静电感应 腐蚀
下载PDF
Magnifying narrow-band imaging endoscopy is superior in diagnosis of early gastric cancer 被引量:26
14
作者 Hang Yu Ai-Ming Yang +7 位作者 Xing-Hua Lu Wei-Xun Zhou Fang Yao Gui-Jun Fei Tao Guo Li-Qing Yao Li-Ping He Bang-Mao Wang 《World Journal of Gastroenterology》 SCIE CAS 2015年第30期9156-9162,共7页
AIM:To evaluate the diagnostic effectiveness of white light endoscopy,magnifying endoscopy(ME),and magnifying narrow-band imaging endoscopy(ME-NBI) in detecting early gastric cancer(EGC).METHODS:From March 2010 to Jun... AIM:To evaluate the diagnostic effectiveness of white light endoscopy,magnifying endoscopy(ME),and magnifying narrow-band imaging endoscopy(ME-NBI) in detecting early gastric cancer(EGC).METHODS:From March 2010 to June 2012,a total of 3616 patients received screening for gastric cancer by magnifying endoscopy. There were 3675 focal gastric lesions detected using conventional high definition white light endoscopy(HD-WLE) in four different referentialhospitals that were recruited for further investigation using ME and ME-NBI. The images obtained from HD-WLE,ME,and ME-NBI were reviewed by four experienced endoscopists to evaluate their diagnostic effectiveness for EGC. The diagnosis of cancerous and non-cancerous lesions was conducted by evaluating the microvascular and microsurface patterns using the VS classification system. The final endoscopic diagnosis of each lesion was determined by consultation when a disagreement occurred. We used histopathological results as the gold standard for the diagnosis of EGC.RESULTS:Among the 3675 lesions found,1508 were validated by pathological findings as chronic gastritis,1279 as chronic gastritis with intestinal metaplasia,631 as low-grade neoplasia,and 257 as EGC. The sensitivity,specificity,positive predictive value,negative predictive value,and accuracy of HD-WLE for the diagnosis of EGC were 71.2%,99.1%,85.5%,97.9% and 97.1%,respectively. The results of ME for diagnosing EGC were 81.3%,98.8%,83.3%,98.6% and 97.6%,respectively. The results of ME-NBI for the diagnosis of EGC were 87.2%,98.6%,82.1%,99.0% and 97.8%,respectively. The diagnostic sensitivity and accuracy of paired ME and ME-NBI were significantly better than those of HD-WLE(P < 0.05).CONCLUSION:HD-WLE has a relatively high accuracy for diagnosing EGC and is an effective screening tool. Further investigations of ME and ME-NBI are required to achieve superior accuracy. 展开更多
关键词 EARLY DIAGNOSIS GASTRIC cancer Gastricmucosa Magnifying ENDOSCOPY narrow-band imaging
下载PDF
Diagnostic performance of magnifying narrow-band imaging for early gastric cancer: A meta-analysis 被引量:18
15
作者 Ying-Ying Hu Qing-Wu Lian +3 位作者 Zheng-Hua Lin Jing Zhong Meng Xue Liang-Jing Wang 《World Journal of Gastroenterology》 SCIE CAS 2015年第25期7884-7894,共11页
AIM: To investigate the performance of magnifying endoscopy with narrow-band imaging(ME-NBI) in the diagnosis of early gastric cancer(EGC).METHODS: Systematic literature searches were conducted until February 2014 in ... AIM: To investigate the performance of magnifying endoscopy with narrow-band imaging(ME-NBI) in the diagnosis of early gastric cancer(EGC).METHODS: Systematic literature searches were conducted until February 2014 in Pub Med, EMBASE, Web of Science, Ovid, Scopus and the Cochrane Library databases by two independent reviewers. Meta-analysis was performed to calculate the pooled sensitivity, specificity and diagnostic odds ratio and to construct a summary receiver operating characteristic(ROC) curve. Subgroup analyses were performed based on the morphology type of lesions, diagnostic standard, the size of lesions, type of assessment, country and sample size to explore possible sources of heterogeneity. A Deeks' asymmetry test was used to evaluate the publication bias.RESULTS: Fourteen studies enrolling 2171 patients were included. The pooled sensitivity, specificity and diagnostic odds ratio for ME-NBI diagnosis of EGC were 0.86(95%CI: 0.83-0.89), 0.96(95%CI: 0.95-0.97) and 102.75(95%CI: 48.14-219.32), respectively, with the area under ROC curve being 0.9623. Among the 14 studies, six also evaluated the diagnostic value of conventional white-light imaging, with a sensitivityof 0.57(95%CI: 0.50-0.64) and a specificity of 0.79(95%CI: 0.76-0.81). When using "VS"(vessel plus surface) ME-NBI diagnostic systems in gastric lesions of depressed macroscopic type, the pooled sensitivity and specificity were 0.64(95%CI: 0.52-0.75) and 0.96(95%CI: 0.95-0.98). For the lesions with a diameter less than 10 mm, the sensitivity and specificity were 0.74(95%CI: 0.65-0.82) and 0.98(95%CI: 0.97-0.98).CONCLUSION: ME-NBI is a promising endoscopic tool in the diagnosis of early gastric cancer and might be helpful in further target biopsy. 展开更多
关键词 narrow-band IMAGING Early GASTRIC cancer Magnifying ENDOSCOPY META-ANALYSIS Conventionalwhite-light IMAGING
下载PDF
Effectiveness of narrow-band imaging magnification for invasion depth in early colorectal cancer 被引量:8
16
作者 Masakatsu Fukuzawa Yutaka Saito +3 位作者 Takahisa Matsuda Toshio Uraoka Takao Itoi Fuminori Moriyasu 《World Journal of Gastroenterology》 SCIE CAS CSCD 2010年第14期1727-1734,共8页
AIM: To evaluate the surface microvascular patterns of early colorectal cancer (ECC) using narrow-band imaging (NBI) with magnification and its effectiveness for invasion depth diagnosis. METHODS: We studied 112 ECC l... AIM: To evaluate the surface microvascular patterns of early colorectal cancer (ECC) using narrow-band imaging (NBI) with magnification and its effectiveness for invasion depth diagnosis. METHODS: We studied 112 ECC lesions [mucosal/ submucosal superficial (m/sm-s), 69; sm-deep (sm-d), 43] ≥ 10 mm that subsequently underwent endoscopic or surgical treatment at our hospital. We compared microvascular architecture revealed by NBI with magnification to histological findings and then to magnifi- cation colonoscopy pit pattern diagnosis. RESULTS: Univariate analysis indicated vessel density: non-dense (P < 0.0001); vessel regularity: negative (P < 0.0001); caliber regularity: negative (P < 0.0001); vessel length: short (P < 0.0001); and vessel meandering: positive (P = 0.002) occurred significantly more often with sm-d invasion than m/sm-s invasion. Multivariate analysis showed sm-d invasion was independently associated with vessel density: non-dense[odds ratio (OR) = 402.5, 95% confidence interval (CI): 12.4-13 133.1] and vessel regularity: negative (OR = 15.9, 95% CI: 1.2-219.1). Both of these findings when combined were an indicator of sm-d invasion with sensitivity, specificity and accuracy of 81.4%, 100% and 92.9%, respectively. Pit pattern diagnosis sensitivity, specificity and accuracy, meanwhile, were 86.0%, 98.6% and 93.8%, respectively, thus, the NBI with magnification findings of non-dense vessel density and negative vessel regularity when combined together were comparable to pit pattern diagnosis. CONCLUSION: Non-dense vessel density and/or negative vessel regularity observed by NBI with magnification could be indicators of ECC sm-d invasion. 展开更多
关键词 Colorectal neoplasms narrow-band imaging MICROVASCULATURE
下载PDF
A method to study interactions between narrow-banded random waves and multi-chamber perforated structures 被引量:9
17
作者 Zhenhua Huang 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 2006年第4期285-292,共8页
A time-domain method, based on linear velocity potential theory, is presented to study the interaction between narrow-banded random waves and perforated structures. A simple relation is derived to estimate the jet len... A time-domain method, based on linear velocity potential theory, is presented to study the interaction between narrow-banded random waves and perforated structures. A simple relation is derived to estimate the jet length of flows through the perforated wall. The reflection coefficient of narrow banded random waves from perforated structures is calculated by assuming a Rayleigh distribution of the heights of incident random waves. For reflection of narrow-banded waves from a single-chamber perforated breakwater, a comparison of the predicted and measured reflection coefficients shows that the method presented in this paper can provide a prediction better than that of regular waves. Numerical results are also reported on the reflection of narrow-banded waves from multi-chamber perforated breakwaters. 展开更多
关键词 Surface waves narrow-banded randomwaves Perforated structures Wave reflection
下载PDF
Standard vs magnifying narrow-band imaging endoscopy for diagnosis of Helicobacter pylori infection and gastric precancerous conditions 被引量:11
18
作者 Jun-Hyung Cho Seong Ran Jeon +1 位作者 So-Young Jin Suyeon Park 《World Journal of Gastroenterology》 SCIE CAS 2021年第18期2238-2250,共13页
BACKGROUND Advances in endoscopic imaging enable the identification of patients at high risk of gastric cancer.However,there are no comparative data on the utility of standard and magnifying narrow-band imaging(M-NBI)... BACKGROUND Advances in endoscopic imaging enable the identification of patients at high risk of gastric cancer.However,there are no comparative data on the utility of standard and magnifying narrow-band imaging(M-NBI)endoscopy for diagnosing Helicobacter pylori(H.pylori)infection,gastric atrophy,and intestinal metaplasia.AIM To compare the diagnostic performance of standard and M-NBI endoscopy for H.pylori gastritis and precancerous conditions.METHODS In 254 patients,standard endoscopy findings were classified into mosaic-like appearance(type A),diffuse homogenous redness(type B),and irregular redness with groove(type C).Gastric mucosal patterns visualized by M-NBI were classified as regular round pits with polygonal sulci(type Z-1),more dilated and linear pits without sulci(type Z-2),and loss of gastric pits with coiled vessels(type Z-3).RESULTS The diagnostic accuracy of standard and M-NBI endoscopy for H.pylori gastritis was 93.3%and 96.1%,respectively.Regarding gastric precancerous conditions,the accuracy of standard and M-NBI endoscopy was 72.0%vs 72.6%for moderate to severe atrophy,and 61.7%vs.61.1%for intestinal metaplasia in the corpus,respectively.Compared to type A and Z-1,types B+C and Z-2+Z-3 were significantly associated with moderate to severe atrophy[odds ratio(OR)=5.56 and 8.67]and serum pepsinogen I/II ratio of≤3(OR=4.48 and 5.69).CONCLUSION Close observation of the gastric mucosa by standard and M-NBI endoscopy is useful for the diagnosis of H.pylori gastritis and precancerous conditions. 展开更多
关键词 ENDOSCOPY Magnifying narrow-band imaging Helicobacter pylori Gastric atrophy Intestinal metaplasia PEPSINOGEN
下载PDF
Narrow-band imaging with magnifying endoscopy is accurate for detecting gastric intestinal metaplasia 被引量:23
19
作者 Edoardo Savarino Marina Corbo +5 位作者 Pietro Dulbecco Lorenzo Gemignani Elisa Giambruno Luca Mastracci Federica Grillo Vincenzo Savarino 《World Journal of Gastroenterology》 SCIE CAS 2013年第17期2668-2675,共8页
AIM:To investigate the predictive value of narrowband imaging with magnifying endoscopy (NBI-ME) for identifying gastric intestinal metaplasia (GIM) in unselected patients. METHODS:We prospectively evaluated consecuti... AIM:To investigate the predictive value of narrowband imaging with magnifying endoscopy (NBI-ME) for identifying gastric intestinal metaplasia (GIM) in unselected patients. METHODS:We prospectively evaluated consecutive patients undergoing upper endoscopy for various indications, such as epigastric discomfort/pain, anaemia, gastro-oesophageal reflux disease, suspicion of peptic ulcer disease, or chronic liver diseases. Patients underwent NBI-ME, which was performed by three blinded, experienced endoscopists. In addition, five biopsies (2 antrum, 1 angulus, and 2 corpus) were taken and examined by two pathologists unaware of the endoscopic findings to determine the presence or absence of GIM. The correlation between light blue crest (LBC) appearance and histology was measured. Moreover, we quantified the degree of LBC appearance as less than 20% (+), 20%-80% (++) and more than 80% (+++) of an image field, and the semiquantitative evaluation of LBC appearance was correlated with IM percentage from the histological findings. RESULTS:We enrolled 100 (58 F/42 M) patients who were mainly referred for gastro-esophageal reflux disease/dyspepsia (46%), cancer screening/anaemia (34%), chronic liver disease (9%), and suspected celiac disease (6%); the remaining patients were referred for other indications. The prevalence of Helicobacter pylori (H. pylori ) infection detected from the biopsies was 31%, while 67% of the patients used proton pump inhibitors. LBCs were found in the antrum of 33 patients (33%); 20 of the cases were classified as LBC+, 9 as LBC++, and 4 as LBC+++. LBCs were found in the gastric body of 6 patients (6%), with 5 of them also having LBCs in the antrum. The correlation between the appearance of LBCs and histological GIM was good, with a sensitivity of 80% (95%CI:67-92), a specificity of 96% (95%CI:93-99), a positive predictive value of 84% (95%CI:73-96), a negative predictive value of 95% (95%CI:92-98), and an accuracy of 93% (95%CI:90-97). The NBI-ME examination overlooked GIM in 8 cases, but the GIM was less than 5% in 7 of the cases. Moreover, in the 6 false positive cases, the histological examination showed the presence of reactive gastropathy (4 cases) or H. pylori active chronic gastritis (2 cases). The semiquantitative correlation between the rate of LBC appearance and the percentage of GIM was 79% (P < 0.01). CONCLUSION:NBI-ME achieved good sensitivity and specificity in recognising GIM in an unselected population. In routine clinical practice, this technique can reliably target gastric biopsies. 展开更多
关键词 narrow-band imaging MAGNIFICATION GASTRIC intestinal METAPLASIA Light blue CREST GASTRIC cancer Endoscopy PRECANCEROUS conditions GASTRIC biopsy
下载PDF
Endocytoscopic narrow-band imaging efficiency for evaluation of inflammatory activity in ulcerative colitis 被引量:4
20
作者 Yasuharu Maeda Kazuo Ohtsuka +14 位作者 Shin-ei Kudo Kunihiko Wakamura Yuichi Mori Noriyuki Ogata Yoshiki Wada Masashi Misawa Akihiro Yamauchi Seiko Hayashi Toyoki Kudo Takemasa Hayashi Hideyuki Miyachi Fuyuhiko Yamamura Fumio Ishida Haruhiro Inoue Shigeharu Hamatani 《World Journal of Gastroenterology》 SCIE CAS 2015年第7期2108-2115,共8页
AIM:To assess the efficacy of endocytoscopic narrowband imaging(EC-NBI)for evaluating the severity of inflammation in ulcerative colitis(UC).METHODS:This retrospective study was conducted at a single tertiary care ref... AIM:To assess the efficacy of endocytoscopic narrowband imaging(EC-NBI)for evaluating the severity of inflammation in ulcerative colitis(UC).METHODS:This retrospective study was conducted at a single tertiary care referral center.We included UC patients who underwent colonoscopy with endocytoscopy from July 2010 to December 2013.ECNBI was performed,and the images were evaluated by assessing visibility,increased vascularization,and the increased calibers of capillaries and were classified as Obscure,Visible or Dilated.Obscure was indicative of inactive disease,while Visible and Dilated were indicative of acute inflammation.This study received Institutional Review Board approval.The primary outcome measures included the diagnostic ability of EC-NBI to distinguish between active and inactive UC on the basis of histological activity.The conventional endoscopic images were classified according to the Mayo endoscopic score.A score of 0 or 1 indicated inactive disease,whereas a score of 2 indicated active disease.RESULTS:Fifty-two patients were enrolled.There was a strong correlation between the EC-NBI findings and the histological assessment(r=0.871,P<0.01).The sensitivity,specificity,positive predictive value,negative predictive value,and accuracy of EC-NBI for diagnosing acute inflammation were 84.0%,100%,87.1%,100%,and 92.3%,respectively,while those for the Mayo endoscopic score were 100%,40.7%,100%,61.0%,and 69.2%,respectively.Compared with conventional endoscopy,EC-NBI was superior in diagnostic specificity,negative predictive value,and accuracy(P<0.001,P=0.001 and P=0.047,respectively).CONCLUSION:The EC-NBI finding of capillaries in the rectal mucosa was strongly correlated with histological inflammation and aided in the differential diagnosis between active and inactive UC. 展开更多
关键词 Endosytoscopy narrow-band IMAGING Magnified endosc
下载PDF
上一页 1 2 11 下一页 到第
使用帮助 返回顶部