期刊文献+
共找到1,205篇文章
< 1 2 61 >
每页显示 20 50 100
Simultaneous oxidation of NO,SO_2 and Hg^0 from flue gas by pulsed corona discharge 被引量:22
1
作者 XU Fei,LUO Zhongyang,CAO Wei,WANG Peng,WEI Bo,GAO Xiang,FANG Mengxiang,CEN Kefa State key Laboratory of Clean Energy Utilization,Zhejiang University,Hangzhou 310027,China. 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2009年第3期328-332,共5页
A process capable of simultaneously oxidizing NO, SO2, and Hg^0 was proposed, using a nigh-voltage and short-duration positive pulsed corona discharge. By focusing on NO, SO2, and Hg^0 oxidation efficiencies, the infl... A process capable of simultaneously oxidizing NO, SO2, and Hg^0 was proposed, using a nigh-voltage and short-duration positive pulsed corona discharge. By focusing on NO, SO2, and Hg^0 oxidation efficiencies, the influences of pulse peak voltage, pulse frequency, initial concentration, electrode number, residence time and water vapor addition were investigated. The results indicate that NO, SO2 and Hg^0 oxidation efficiencies depend primarily on the radicals (OH, HO2, O) and the active species (O3, H2O2, etc.) produced by the pulsed corona discharge. The NO, SO2 and Hg^0 oxidation efficiencies could be improved as pulse peak voltage, pulse frequency, electrode number and residence time increased, but they were reduced with increasing initial concentrations. By adding water vapor, the SO2 oxidation efficiency was improved remarkably, while the NO oxidation efficiency decreased slightly. In our experiments, the simultaneous NO, SO2, and Hg^0 oxidation efficiencies reached to 40%, 98%, and 55% with the initial concentrations 479 mg/m^3, 1040 mg/m^3, and 15.0 μg/m^3, respectively. 展开更多
关键词 pulsed corona discharge NO SO2 Hg^0 RADICAL active species oxidation efficiency
下载PDF
Numerical simulation and experimental validation of a direct current air corona discharge under atmospheric pressure 被引量:14
2
作者 刘兴华 何为 +3 位作者 杨帆 王虹宇 廖瑞金 肖汉光 《Chinese Physics B》 SCIE EI CAS CSCD 2012年第7期368-377,共10页
Air corona discharge is one of the critical problems associated with high-voltage equipment. Investigating the corona mechanism plays a key role in enhancing the electrical insulation performance. An improved self-con... Air corona discharge is one of the critical problems associated with high-voltage equipment. Investigating the corona mechanism plays a key role in enhancing the electrical insulation performance. An improved self-consistent multi-component two-dimensional plasma hybrid model is presented for the simulation of a direct current atmospheric pressure corona discharge in air. The model is based on plasma hydrodynamic and chemical models, and includes 12 species and 26 reactions. In addition, the photoionization effect is introduced into the model. The simulation on a bar-plate electrode configuration with an inter-electrode gap of 5.0 mm is carried out. The discharge voltage- current characteristics and the current density distribution predicted by the hybrid model agree with the experimental measurements. In addition, the dynamics of volume charged species generation, discharge current waveform, current density distribution at an electrode, charge density, electron temperature, and electric field variations are investigated in detail based on the model. The results indicate that the model can contribute valuable insights into the physics of an air plasma discharge. 展开更多
关键词 corona discharge hybrid model discharge voltage-current characteristics current den-sity distribution
下载PDF
Removal of adhesive dusts from flue gas using corona discharges with spraying water 被引量:11
3
作者 XU De\|xuan, ZHAO Jian\|wei, DING Yun\|zheng, GE Wei\|li (Department of Environmental Science and Engineering, Northeast Normal University, Changchun 130024, China. 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2003年第4期554-561,共8页
Effective removal of adhesive and fine dusts from flue gas is very difficult. A new method of electrostatic precipitation of the corona discharges with spraying water(CDSW) was introduced. A new electrode configuratio... Effective removal of adhesive and fine dusts from flue gas is very difficult. A new method of electrostatic precipitation of the corona discharges with spraying water(CDSW) was introduced. A new electrode configuration and the circulation spraying of water were employed in the method. The efficient electrostatic precipitation for adhesive and fine dusts can be accomplished without any drain water during a long operating period. The fundamental structure, discharge characteristics, mechanism of spraying and precipitation principle of the electrostatic precipitation using CDSW were described and analyzed. The V I characteristics, spraying state, supplying water quantity, influence of temperature and clean of the electrodes were researched in series experiments. The treating effects of circulating spraying using the corona plasma at the same time of electrostatic precipitation were investigated. The fundamental theories and experimental data were proposed, in order to effectively remove the adhesive dusts from flue gas using CDSW in practice. 展开更多
关键词 aerosol with adhesive dusts corona discharges with spraying water electrostatic precipitation
下载PDF
Hydrogen Production from Methanol Using Corona Discharges 被引量:5
4
作者 XiZhenLIU ChangJunLIU BaldurELIASSON 《Chinese Chemical Letters》 SCIE CAS CSCD 2003年第6期631-633,共3页
Hydrogen production at room temperature from liquid methanol has been conducted using corona discharge. The content of water in methanol solution has a significant effect on this production. When water concentration... Hydrogen production at room temperature from liquid methanol has been conducted using corona discharge. The content of water in methanol solution has a significant effect on this production. When water concentration increases from 1.0% to 16.7%,the methanol conversion rate changes from 0.196 to 0.284 mol/h. An important finding in this investigation is the formation of ethylene glycol as a major by-product. The yield of ethylene glycol is ranged from 0.0045 to 0.0075 mol/h based on the water content. 展开更多
关键词 HYDROGEN METHANOL PLASMA corona discharge.
下载PDF
Enhancement of corona discharge induced wind generation with carbon nanotube and titanium dioxide decoration 被引量:3
5
作者 Jianchun Ye Jun Li +2 位作者 Xiaohong Chen Sumei Huang Wei Ou-Yang 《Chinese Physics B》 SCIE EI CAS CSCD 2019年第9期282-287,共6页
Dip-coated double-wall carbon nanotubes(DWCNTs) and titanium dioxide(TiO2) sol have been prepared and smeared onto the tip of a conductive iron needle which serves as the corona discharge anode in a needle-cylinder co... Dip-coated double-wall carbon nanotubes(DWCNTs) and titanium dioxide(TiO2) sol have been prepared and smeared onto the tip of a conductive iron needle which serves as the corona discharge anode in a needle-cylinder corona system.Compared with the discharge electrode of a CNT-coated needle tip, great advancements have been achieved with the TiO_2/CNT-coated electrode, including higher discharge current, ionic wind velocity, and energy conversion efficiency,together with lower corona onset voltage and power consumption.Several parameters related to the discharge have been phenomenologically and mathematically studied for comparison.Thanks to the morphology reorientation of the CNT layer and the anti-oxidation of TiO_2, better performance of corona discharge induced wind generation of the TiO2/CNT-coated electrode system has been achieved.This novel decoration may provide better thoughts about the corona discharge application and wind generation. 展开更多
关键词 corona discharge INDUCED WIND WIND velocity carbon NANOTUBES titanium dioxide
下载PDF
Factors Influencing the Electron Yield of Needle-Ring Pulsed Corona Discharge Electron Source for Negative Ion Mobility Spectrometer 被引量:4
6
作者 刘欣 李胜利 李铭书 《Plasma Science and Technology》 SCIE EI CAS CSCD 2013年第12期1215-1220,共6页
A simple negative ion mobility spectrometer (IMS) is designed and used to investi- gate the factors that influence the number and efficiency of electrons generated by the needle-ring pulsed corona discharge electron... A simple negative ion mobility spectrometer (IMS) is designed and used to investi- gate the factors that influence the number and efficiency of electrons generated by the needle-ring pulsed corona discharge electron source. Simulation with Ansoft Maxwell 12 is carried out to analyze the electric field distribution within the IMS, and to offer the basis and foundation for analyzing the measurement results. The measurement results of the quantities of electrons show that when the drift electric field strength and the ring inner diameter rise, both the number of ef- fective electrons and the effective electron rate are increased. When the discharge voltage becomes stronger, the number of effective electrons goes up while the effective electron rate goes down. In light of the simulation results, mechanisms underlying the effects of drift electric field strength, ring inner diameter, and discharge voltage on the effective electron number and effective electron rate are discussed. These will make great sense for designing negative ion mode IMS using the needle-ring pulsed corona discharge as the electron source. 展开更多
关键词 ion mobility spectrometer electron source pulsed corona discharge effectiveelectrons simulation
下载PDF
Destruction of VOCs by combination of corona discharge and catalysis techniques 被引量:3
7
作者 Muhammad Arif Malik Jiang Xuan zhen 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 1998年第3期21-26,共6页
The catalytic effect of alumina on the destruction of toluene, benzene, acetone and methanol, in DC pulsed corona discharge reactor was studied. In the presence of alumina the inlet concentration of the VOCs was varie... The catalytic effect of alumina on the destruction of toluene, benzene, acetone and methanol, in DC pulsed corona discharge reactor was studied. In the presence of alumina the inlet concentration of the VOCs was varied from ~5×10-6 mol/L to ~80×10-6 mol/L, and their decomposition efficiency (conversion %) was found to be 99%-80% for toluene, 99%-97% for benzene, 95%-92% for acetone, and 72%-85% for methanol. Corresponding decomposition in the absence of alumina was 90%-38% for toluene, 89%-57% for benzene, 42%-30% for acetone, and 47%-19% for methanol. Feed gas flow rate was 400 cm 3/min and power reading from DC source was 74 W in all of the experiments. Alumina also shifted the CO/CO 2 ratio in the by products in favor of CO 2. Ozone concentration at the reactor outlet was higher in the presence of alumina. Enhancement in VOCs decomposition by alumina was explained on the basis of higher concentration of ozone and its precursor atomic oxygen O . Decomposition efficiency (conversion %) for individual compounds was found to be inversely proportional to the ionization potential of the compound, under identical conditions. Double DC high voltage sources pulse generator was tested and found to improve VOCs decomposition compared with the conventional single DC high voltage source. 展开更多
关键词 corona discharge catalysis techniques VOCS decomposition efficiency.
下载PDF
Research on Nanosecond Pulse Corona Discharge with Cross Magnetic Field Applied 被引量:4
8
作者 何正浩 余福胜 +3 位作者 胡枫 袁云 郭丽娜 李劲 《Plasma Science and Technology》 SCIE EI CAS CSCD 2007年第6期706-708,共3页
An application of magnetic field to the nanosecond pulse corona discharge is investigated. A cylinder reactor with different corona electrodes is set up for experimental study. A magnetic field with its direction perp... An application of magnetic field to the nanosecond pulse corona discharge is investigated. A cylinder reactor with different corona electrodes is set up for experimental study. A magnetic field with its direction perpendicular to the corona discharge is applied. Different discharge images are taken under single nanosecond pulse with a high sensitive UV-visible light imagine recorder. Experimental results show that with a cross magnetic field the nanosecond corona discharge both generates paths and develops homogeneously in space more than that without the magnetic field. The results may lead to a possibility to apply a cross magnetic field on nanosecond pulse corona discharge for getting higher desulfurization efficiency. 展开更多
关键词 nanosecond pulse corona discharge cross magnetic field
下载PDF
Degradation of Organic Compounds by Active Species Sprayed in a Dielectric Barrier Corona Discharge System 被引量:4
9
作者 李杰 宋玲 +3 位作者 刘强 屈广周 李国锋 吴彦 《Plasma Science and Technology》 SCIE EI CAS CSCD 2009年第2期211-215,共5页
Investigation was made into the degradation of organic compounds by a dielectric barrier corona discharge (DBCD) system. The DBCD, consisting of a quartz tube, a concentric high voltage electrode and a net wrapped t... Investigation was made into the degradation of organic compounds by a dielectric barrier corona discharge (DBCD) system. The DBCD, consisting of a quartz tube, a concentric high voltage electrode and a net wrapped to the external wall (used as ground electrode), was introduced to generate active species which were sprayed into the organic solution through an aerator fixed on the bottom of the tube. The effect of four factors-the discharge voltage, gas flow rate, solution conductivity, and pH of wastewater, on the degradation efficiency of phenol was assessed. The obtained results demonstrated that this process was an effective method for phenol degradation. The degradation rate was enhanced with the increase in power supplied. The degradation efficiency in alkaline conditions was higher than those in acid and neutral conditions. The optimal gas flow rate for phenol degradation in the system was 1.6 L/min, while the solution conductivity had little effect on the degradation. 展开更多
关键词 dielectric barrier corona discharge (DBCD) active species organic compound degradation wastewater treatment
下载PDF
Removal of Volatile Organic Compounds (VOCs) Mixture by Multi-Pin-Mesh Corona Discharge Combined with Pulsed High-Voltage 被引量:4
10
作者 张玥 李锻 王洪昌 《Plasma Science and Technology》 SCIE EI CAS CSCD 2010年第6期702-707,共6页
Removal of single component and binary mixtures of benzene and m-xylene using a multi-pin-mesh reactor was studied to find the decomposition characteristics, carbon balance and CO2 selectivity. The decomposition rate ... Removal of single component and binary mixtures of benzene and m-xylene using a multi-pin-mesh reactor was studied to find the decomposition characteristics, carbon balance and CO2 selectivity. The decomposition rate of benzene in mixture was approximately 16% lower than that of single component benzene. However, the decomposition rate of m-xylene in mixture was slightly higher than that of single component m-xylene. Carbon balance of the mixture decomposition process achieved a lower level than that of single component benzene/m-xylene. Increase in the specific input energy was helpful to improve CO2 selectivity in the single component decomposition process, while the specific input energy had a negligible effect on CO2 selectivity in the mixture decomposition process. By changing the oxygen content in background gas, we found that different types of radicals showed different reaction activities toward benzene and m-xylene. Benzene was more likely to react with nitrogen-containing radicals, while m-xylene was more likely to react with oxygen-containing radicals. 展开更多
关键词 multi-pin-mesh corona discharge pulsed high-voltage mixed VOCs
下载PDF
Catalyst assisted destruction of trichloro ethylene and toluene in corona discharges 被引量:3
11
作者 Muhammad Arif Malik, JIANG Xuan\|zhen (Department of Chemistry, University of Zhejiang, Hangzhou 310027, China) Foundation item: National Natural Science Foundation of China (No. 29576261) 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2000年第1期9-13,共5页
Destruction of trichloro ethylene (C 2HCl 3) by pulsed corona discharge reactor packed with alumina pellets and in absence of packing was investigated. Higher conversion of C 2HCl 3 was observed in presence of alu... Destruction of trichloro ethylene (C 2HCl 3) by pulsed corona discharge reactor packed with alumina pellets and in absence of packing was investigated. Higher conversion of C 2HCl 3 was observed in presence of alumina than in absence of packing. Furthermore CO/CO 2 ratio in the by products was found to shift in favor of CO 2 by alumina compared with absence of packing. Influence of catalyst porosity on C 2HCl 3 destruction and on by product ozone generation during the processing was also studied. Both alumina Ⅰ and alumina Ⅱ show similar improvement in C 2HCl 3 destruction. However, more important observation was that alumina Ⅰ produces higher by product ozone, while, alumina Ⅱ produces lower by product ozone, than in the case of no packing. The catalyst porosity effect was also investigated for destruction of toluene and was found to be similar. Intermediates of C 2HCl 3 destruction, as identified by GC MS, were COCl 2, CH 2Cl 2CHCl 3, CCl 4 and C 2HCl 5. In presence of alumina the amount of these intermediates was much reduced, indicating the catalytic function of alumina. 展开更多
关键词 corona discharges plasma trichloro ethylene TOLUENE alumina CLC number: X701 Document code: A
下载PDF
Characteristics and underlying physics of ionic wind in dc corona discharge under different polarities 被引量:2
12
作者 Tongkai Zhang Yu Zhang +2 位作者 Qizheng Ji Ben Li Jiting Ouyang 《Chinese Physics B》 SCIE EI CAS CSCD 2019年第7期324-332,共9页
During a dc corona discharge, the ions’ momentum will be transferred to the surrounding neutral molecules, inducing an ionic wind.The characteristics of corona discharge and the induced ionic wind are investigated ex... During a dc corona discharge, the ions’ momentum will be transferred to the surrounding neutral molecules, inducing an ionic wind.The characteristics of corona discharge and the induced ionic wind are investigated experimentally and numerically under different polarities using a needle-to-ring electrode configuration.The morphology and mechanism of corona discharge, as well as the characteristics and mechanism of the ionic wind, are different when the needle serves as cathode or anode.Under the different polarities of the applied voltage, the ionic wind velocity has a linear relation with the overvoltage.The ionic wind is stronger but has a smaller active region for positive corona compared to that for negative corona under a similar condition.The involved physics are analyzed by theoretical deduction as well as simulation using a fluid model.The ionic wind of negative corona is mainly affected by negative ions.The discharge channel has a dispersed feature due to the dispersed field, and therefore the ionic wind has a larger active area.The ionic wind of positive corona is mainly affected by positive ions.The discharge develops in streamer mode, leading to a stronger ionic wind but a lower active area. 展开更多
关键词 corona discharge IONIC wind ELECTRODE polarity
下载PDF
Removal of NO and SO2 in Corona Discharge Plasma Reactor with Water Film 被引量:3
13
作者 贺元吉 董丽敏 杨嘉祥 《Plasma Science and Technology》 SCIE EI CAS CSCD 2004年第2期2250-2254,共5页
In this paper, a novel type of a corona discharge plasma reactor was designed, which consists of needle-plate-combined electrodes, in which a series of needle electrodes are placed in a glass container filled with flu... In this paper, a novel type of a corona discharge plasma reactor was designed, which consists of needle-plate-combined electrodes, in which a series of needle electrodes are placed in a glass container filled with flue gas, and a plate electrode is immersed in the water. Based on this model, the removal of NO and SO2 was tested experimentally. In addition, the effect of streamer polarity on the reduction of SO2 and NO was investigated in detail. The experimental results show that the corona wind formed between the high-voltage needle electrode and the water by corona discharge enhances the cleaning efficiency of the flue gas because of the presence of water, and the cleaning efficiency will increase with the increase of applied dc voltage within a definite range. The removal efficiency of SO2 up to 98%, and about 85% of NOx removal under suitable conditions is obtained in our experiments. 展开更多
关键词 corona discharge plasma reactor water film
下载PDF
Electrical Characteristics of Pulsed Corona Discharge Plasmas in Chitosan Solution 被引量:2
14
作者 鲁娜 冯迎春 +3 位作者 李杰 宿艳 商克峰 吴彦 《Plasma Science and Technology》 SCIE EI CAS CSCD 2014年第2期128-133,共6页
Pulsed discharge plasma has exhibited active potential to prepare low molecular weight chitosan. In the present study, the viscosity of ehitosan solution was decreased noticeably after treated with pulsed corona disch... Pulsed discharge plasma has exhibited active potential to prepare low molecular weight chitosan. In the present study, the viscosity of ehitosan solution was decreased noticeably after treated with pulsed corona discharge plasma. An experimental investigation on electrical characteristics of pulsed corona discharge plasma in chitosan solution was conducted with a view toward getting insight into discharge process. Factors affecting I-V curve, single pulse injec- tion energy and pulse width were studied. Experimental results showed positive effect of pulsed peak voltage on discharge plasma in chitosan solution. Pulse-forming capacitor greatly influenced the discharge form, and 4 nF was observed as a suitable value for efficiently generating stable discharge plasmas. As the electrode distance was larger than 10 ram, it had slight impact on dis- charge plasma due to the excellent conductive-property of chitosan solution. The injection energy significantly increased with air flow rate, while the pulse width hardly changed as the air flow rate increased from 0.5 m^3/h to 1.0 m^3/h. This study is expected to provide reference for promoting the application of pulsed corona discharge plasma to ehitosan solution treatment. 展开更多
关键词 electrical characteristics pulsed corona discharge plasma chitosan solution
下载PDF
Experimental study of the effect of gas discharge on ionic liquid electrospray
15
作者 石文 杨鹏飞 +1 位作者 宋培义 吴健 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第4期37-43,共7页
Ionic liquid electrospray(ILE) in an atmospheric environment is often accompanied by the gas discharge phenomenon. It interferes with the normal operation of the electrospray and the measurement of experimental parame... Ionic liquid electrospray(ILE) in an atmospheric environment is often accompanied by the gas discharge phenomenon. It interferes with the normal operation of the electrospray and the measurement of experimental parameters. In this study, electrospray experiments were conducted on the ionic liquid EMI-BF4. The observations revealed that the operating modes of the ionic liquid depend on the voltage polarity at high voltages. Additionally, a correspondence between the operating mode of ILE and the current signal in the circuit was established. The shape of the liquid cone formed at the needle tip bore a striking resemblance to the plume of corona discharge, suggesting that the motion trajectory of electrons influenced the curvature of the liquid cone. Steamer theory provided a clear explanation for the change in curvature as the voltage increased. 展开更多
关键词 ionic liquid ELECTROSPRAY Taylor cone jet corona discharge
下载PDF
The Experimental Investigations of Dielectric Barrier Discharge and Pulse Corona Discharge in Air Cleaning 被引量:1
16
作者 左莉 侯立安 杨林松 《Plasma Science and Technology》 SCIE EI CAS CSCD 2003年第5期1961-1964,共4页
The dielectric barrier discharge (DBD) and pulse corona discharge(PCD) plasma generator was used to remove NH3, H2S, C7H8 etc. from atmosphere. The principle and characteristic of the two ways was discussed in the art... The dielectric barrier discharge (DBD) and pulse corona discharge(PCD) plasma generator was used to remove NH3, H2S, C7H8 etc. from atmosphere. The principle and characteristic of the two ways was discussed in the article. The test shows the result of PCD is better than that of DBD. 展开更多
关键词 low temperature plasma dielectric barrier discharge pulse corona discharge air cleaning
下载PDF
Conversion of Methane to Hydrogen via Pulsed Corona Discharge 被引量:1
17
作者 Lekha Nath Mishra Kanetoshi Shibata +2 位作者 Hiroaki Ito Noboru Yugami Yasushi Nishida 《Journal of Natural Gas Chemistry》 CAS CSCD 2004年第2期82-86,共5页
Experiments are performed to develop a pulsed corona discharge system for the conversion of methane to hydrogen at atmospheric pressure (≈760 Torr) without using a catalyst. The corona discharge was energized by 10-... Experiments are performed to develop a pulsed corona discharge system for the conversion of methane to hydrogen at atmospheric pressure (≈760 Torr) without using a catalyst. The corona discharge was energized by 10-12 μs wide voltage pulses (≤7 kV) at a repetition rate of about 1.0-1.5 kHz. The residual gases were characterized by mass spectrometry. The conversion of methane is as high as 50.8% producing the 70% yield of hydrogen. The influences of argon on the discharge of methane were studied. This result could be useful for the mass production of hydrogen in both academic and industrial point of view. 展开更多
关键词 pulsed corona discharge mass spectrometer METHANE HYDROGEN
下载PDF
Efficient direction-independent fog harvesting using a corona discharge device with a multi-electrode structure 被引量:1
18
作者 Dingchen LI Chuan LI +5 位作者 Jiawei LI Wendi YANG Menghan XIAO Ming ZHANG Yong YANG Kexun YU 《Plasma Science and Technology》 SCIE EI CAS CSCD 2022年第9期98-107,共10页
Efflcient collection of water from fog can effectively alleviate the problem of water shortages in foggy but water-scarce areas,such as deserts,islands and so on.Unlike inefflcient fog meshes,corona discharge can char... Efflcient collection of water from fog can effectively alleviate the problem of water shortages in foggy but water-scarce areas,such as deserts,islands and so on.Unlike inefflcient fog meshes,corona discharge can charge water droplets and further enhance the water-collecting effect.This study proposes a novel multi-electrode collecting structure that can achieve efflcient and direction-independent water collection from fog.The multi-electrode structure consists of three parts:a charging electrode,an intercepting electrode and a ground electrode.Four types of watercollecting structures are compared experimentally,and the collection rates from a traditional fog mesh,a wire-mesh electrode with fog coming from a high-voltage electrode,a wire-mesh electrode with fog coming from a ground electrode and a multi-electrode structure are 2–3 g h^(-1),100–120 g h^(-1),60–80 g h^(-1)and 200–220 g h^(-1),respectively.The collection rate of the multielectrode structure is 100–150 times that of a traditional fog mesh and 2–4 times that of a wiremesh electrode.These results demonstrate the superiority of the multi-electrode structure in fog collection.In addition,the motion equation of charged droplets in an electric fleld is also derived,and the optimization strategy of electrode spacing is also discussed.This structure can be applied not only to fog collection,but also to air puriflcation,factory waste gas treatment and other flelds. 展开更多
关键词 fog collection corona discharge wire-mesh electrode multi-electrode structure collection rate
下载PDF
Electro-Hydrodynamics and Kinetic Modeling of Dry and Humid Air Flows Activated by Corona Discharges 被引量:1
19
作者 J. P. SARRETTE O. EICHWALD +2 位作者 F. MARCHAL O. DUCASSE M. YOUSFI 《Plasma Science and Technology》 SCIE EI CAS CSCD 2016年第5期469-472,共4页
The present work is devoted to the 2D simulation of a point-to-plane Atmospheric Corona Discharge Reactor (ACDR) powered by a DC high voltage supply. The corona reactor is periodically crossed by thin mono filamenta... The present work is devoted to the 2D simulation of a point-to-plane Atmospheric Corona Discharge Reactor (ACDR) powered by a DC high voltage supply. The corona reactor is periodically crossed by thin mono filamentary streamers with a natural repetition frequency of some tens of kHz. The study compares the results obtained in dry air and in air mixed with a small amount of water vapour (humid air). The simulation involves the electro-dynamics~ chemical kinetics and neutral gas hydrodynamics phenomena that influence the kinetics of the chemical species transformation. Each discharge lasts about one hundred of a nanosecond while the post- discharge occurring between two successive discharges lasts one hundred of a microsecond. The ACDR is crossed by a lateral dry or humid air flow initially polluted with 400 ppm of NO. After 5 ms, the time corresponding to the occurrence of 50 successive discharge/post-discharge phases, a higher NO removal rate and a lower ozone production rate are found in humid air. This change is due to the presence of the HO2 species formed from the H primary radical in the discharge zone. 展开更多
关键词 DC corona discharge humid air chemistry plasma simulation NO treatment
下载PDF
Treatment of Dyeing Wastewater by Using Positive Pulsed Corona Discharge to Water Surface 被引量:1
20
作者 Young Sun MOK HyunTaeAHN JoengTaiKIM 《Plasma Science and Technology》 SCIE EI CAS CSCD 2007年第1期71-75,共5页
This study investigated the treatment of textile-dyeing wastewater by using an electrical discharge technique (positive pulsed corona discharge). The high-voltage electrode was placed above the surface Of the wastew... This study investigated the treatment of textile-dyeing wastewater by using an electrical discharge technique (positive pulsed corona discharge). The high-voltage electrode was placed above the surface Of the wastewater while the ground electrode was submerged in the wastewater. The electrical discharge starting at the tip of the high voltage electrode propagated toward the surface of the wastewater, producing various oxidative radicals and ozone. Oxygen was used as the working gas instead of air to prevent nitrogen oxides from forming. The simulated wastewater was made up with amaranth, which is a kind of azo dye. The results obtained showed that the chromaticity of the wastewater was almost completely removed within an hour. The ultraviolet/visible spectra of the wastewater treated by the electrical discharge revealed that the total hydrocarbon level also decreased significantly. 展开更多
关键词 positive pulsed corona discharge textile-dyeing wastewater CHROMATICITY
下载PDF
上一页 1 2 61 下一页 到第
使用帮助 返回顶部