The purpose of the present study is to investigate the influence of different types of shear connectors on mechanical behavior of composite steel and concrete girders under negative bending moment. Two overturned simp...The purpose of the present study is to investigate the influence of different types of shear connectors on mechanical behavior of composite steel and concrete girders under negative bending moment. Two overturned simply supported steel-concrete composite girders with different shear connectors including studs and PBLs (perfo-bond strips) were tested under point load in the mid-span. Based on the experimental observations, a three-dimensional FE (finite element) model capable of analyzing the composite girders subjected to negative bending moment was built. Load and deformation response, concrete initial cracking and composite girder ultimate load bearing capacity, strain development process of reinforcing bars before and after concrete cracking were observed in the test and compared with the numerical values. Results predicted by this modeling method are in good agreement with those obtained from the tests. Furthermore, the %rack closure" or "through crack" load were recorded by π-ganges in the tests and compared with the code-specified ultimate load.展开更多
Improving the cracking resistance of steel-normal concrete(NC)composite beams in the negative moment region is one of the main tasks in designing continuous composite beam(CCB)bridges due to the low tensile strength o...Improving the cracking resistance of steel-normal concrete(NC)composite beams in the negative moment region is one of the main tasks in designing continuous composite beam(CCB)bridges due to the low tensile strength of the NC deck at pier supports.This study proposed an innovative structural configuration for the negative bending moment region in a steel-concrete CCB bridge with the aid of ultrahigh performance concrete(UHPC)layer.In order to investigate the feasibility and effectiveness of this new UHPC jointed structure in the negative bending moment region,field load testing was conducted on a newly built full-scale bridge.The newly designed structural configuration was described in detail regarding the structural characteristics(cracking resistance,economy,durability,and constructability).In the field investigation,strains on the surface of the concrete bridge deck,rebar,and steel beam in the negative bending moment region,as well as mid-span deflection,were measured under different load cases.Also,a finite element model for the four-span superstructure of the full-scale bridge was established and validated by the field test results.The simulated results in terms of strains and mid-span deflection showed moderate consistency with the test results.This field test and the finite element model results demonstrated that the new configuration with the UHPC layer provided an effective alternative for the negative bending moment region of the composite beam.展开更多
文摘The purpose of the present study is to investigate the influence of different types of shear connectors on mechanical behavior of composite steel and concrete girders under negative bending moment. Two overturned simply supported steel-concrete composite girders with different shear connectors including studs and PBLs (perfo-bond strips) were tested under point load in the mid-span. Based on the experimental observations, a three-dimensional FE (finite element) model capable of analyzing the composite girders subjected to negative bending moment was built. Load and deformation response, concrete initial cracking and composite girder ultimate load bearing capacity, strain development process of reinforcing bars before and after concrete cracking were observed in the test and compared with the numerical values. Results predicted by this modeling method are in good agreement with those obtained from the tests. Furthermore, the %rack closure" or "through crack" load were recorded by π-ganges in the tests and compared with the code-specified ultimate load.
基金The authors would like to acknowledge the following funders for their support to the studies in this paper:the National Key R&D Program of China(No.2018YFC0705406)the National Natural Science Foundation of China(Grant No.51778223)+1 种基金the Major Program of Science and Technology of Hunan Province(No.2017SK1010)the Hunan Provincial Innovation Foundation for Postgraduate(No.CX2017B119).
文摘Improving the cracking resistance of steel-normal concrete(NC)composite beams in the negative moment region is one of the main tasks in designing continuous composite beam(CCB)bridges due to the low tensile strength of the NC deck at pier supports.This study proposed an innovative structural configuration for the negative bending moment region in a steel-concrete CCB bridge with the aid of ultrahigh performance concrete(UHPC)layer.In order to investigate the feasibility and effectiveness of this new UHPC jointed structure in the negative bending moment region,field load testing was conducted on a newly built full-scale bridge.The newly designed structural configuration was described in detail regarding the structural characteristics(cracking resistance,economy,durability,and constructability).In the field investigation,strains on the surface of the concrete bridge deck,rebar,and steel beam in the negative bending moment region,as well as mid-span deflection,were measured under different load cases.Also,a finite element model for the four-span superstructure of the full-scale bridge was established and validated by the field test results.The simulated results in terms of strains and mid-span deflection showed moderate consistency with the test results.This field test and the finite element model results demonstrated that the new configuration with the UHPC layer provided an effective alternative for the negative bending moment region of the composite beam.