期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
A numerical model of a coated capillary-plate thermal neutron collimator 被引量:1
1
作者 田阳 杨祎罡 +1 位作者 李玉兰 李元景 《Chinese Physics C》 SCIE CAS CSCD 2012年第5期438-442,共5页
A novel thermal neutron collimator was successfully fabricated by coating the inner surface of the capillary plate (CP) with gadolinium oxide using atomic layer deposition (ALD) technology. This CP-based collimato... A novel thermal neutron collimator was successfully fabricated by coating the inner surface of the capillary plate (CP) with gadolinium oxide using atomic layer deposition (ALD) technology. This CP-based collimator is efficient and compact. A numerical model is presented in the paper to estimate the main performance characteristics of the collimator and to optimize the design for specific applications. According to the results of the calculation based on currently available CPs, the FWHM of the collimator’s rocking curve can be smaller than 0.15 while suppressing more than 99.9% of the incident thermal neutrons on the double wings of the curve. Such a coated CP is as thin as 1.25 mm or even thinner, providing high angular resolution with good transmission in a very limited space. 展开更多
关键词 neutron collimator capillary plate atomic layer deposition GADOLINIUM
原文传递
Neutron collimator design of neutron radiography based on the BNCT facility
2
作者 杨晓鹏 俞伯祥 +9 位作者 李义国 彭旦 鲁谨 张高龙 赵航 章爱武 李春阳 刘万金 胡涛 吕军光 《Chinese Physics C》 SCIE CAS CSCD 2014年第2期97-100,共4页
For the research of CCD neutron radiography, a neutron collimator was designed based on the exit of thermal neutron of the Boron Neutron Capture Therapy(BNCT) reactor. Based on the Geant4 simulations, the preliminar... For the research of CCD neutron radiography, a neutron collimator was designed based on the exit of thermal neutron of the Boron Neutron Capture Therapy(BNCT) reactor. Based on the Geant4 simulations, the preliminary choice of the size of the collimator was determined. The materials were selected according to the literature data. Then, a collimator was constructed and tested on site. The results of experiment and simulation show that the thermal neutron flux at the end of the neutron collimator is greater than 1.0×10^6n/cm^2/s, the maximum collimation ratio(L/D) is 58, the Cd-ratio(Mn) is 160 and the diameter of collimator end is 10 cm. This neutron collimator is considered to be applicable for neutron radiography. 展开更多
关键词 neutron radiography ICCD camera thermal neutron collimator thermal neuron flux collimation ratio(L/D
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部