Performance optimization of the neutron-sensitive image intensifier used in neutron imaging
1
作者 谭金昊 宋玉收 +14 位作者 周健荣 杨文钦 蒋兴奋 刘杰 张超月 周晓娟 夏远光 刘术林 闫保军 刘辉 王松林 赵豫斌 庄建 孙志嘉 陈元柏 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第8期380-387,共8页
As a non-destructive testing technology,neutron imaging plays an important role in various fields,including material science,nuclear engineering,and fundamental science.An imaging detector with a neutron-sensitive ima... As a non-destructive testing technology,neutron imaging plays an important role in various fields,including material science,nuclear engineering,and fundamental science.An imaging detector with a neutron-sensitive image intensifier has been developed and demonstrated to achieve good spatial resolution and timing resolution.However,the influence of the working voltage on the performance of the neutron-sensitive imaging intensifier has not been studied.To optimize the performance of the neutron-sensitive image intensifier at different voltages,experiments have been performed at the China Spallation Neutron Source(CSNS)neutron beamline.The change in the light yield and imaging quality with different voltages has been acquired.It is shown that the image quality benefits from the high gain of the microchannel plate(MCP)and the high accelerating electric field between the MCP and the screen.Increasing the accelerating electric field is more effective than increasing the gain of MCPs for the improvement of the imaging quality.Increasing the total gain of the MCP stack can be realized more effectively by improving the gain of the standard MCP than that of the n MCP.These results offer a development direction for image intensifiers in the future. 展开更多
关键词 neutron detector neutron imaging microchannel plate image intensifier
下载PDF
R-L Method and BLS-GSM Denoising for Penumbra Image Reconstruction 被引量:1
2
作者 张美 李阳 +3 位作者 盛亮 黎春花 魏福利 彭博东 《Plasma Science and Technology》 SCIE EI CAS CSCD 2013年第12期1259-1262,共4页
When neutron yield is very low, reconstruction of coding penumbra image is rather difficult. In this paper, low-yield (109) 14 MeV neutron penumbra imaging was simulated by Monte Carlo method. The Richardson Lucy (... When neutron yield is very low, reconstruction of coding penumbra image is rather difficult. In this paper, low-yield (109) 14 MeV neutron penumbra imaging was simulated by Monte Carlo method. The Richardson Lucy (R-L) iteration method was proposed to incorporated with Bayesian least square-Gaussian scale mixture model (BLS-GSM) wavelet denoising for the simulated image. Optimal number of R-L iterations was gotten by a large number of tests. The results show that compared with Wiener method and median filter denoising, this method is better in restraining background noise, the correlation coefficient Rsr between the reconstructed and the real images is larger, and the reconstruction result is better. 展开更多
关键词 inertial confinement fusion neutron penumbra imaging BLS-GSM Wavelet denoising R-L iteration restoration
下载PDF
First neutron Bragg-edge imaging experimental results at CSNS 被引量:1
3
作者 陈洁 谭志坚 +12 位作者 刘玮强 邓司浩 王声翔 王立毅 郑海彪 卢怀乐 沈斐然 郝嘉政 周晓娟 周健荣 孙志嘉 何伦华 梁天骄 《Chinese Physics B》 SCIE EI CAS CSCD 2021年第9期45-48,共4页
The neutron Bragg-edge imaging is expected to be a new non-destructive energy-resolved neutron imaging technique for quantitatively two-dimensional or three-dimensional visualizing crystallographic information in a bu... The neutron Bragg-edge imaging is expected to be a new non-destructive energy-resolved neutron imaging technique for quantitatively two-dimensional or three-dimensional visualizing crystallographic information in a bulk material,which could be benefited from pulsed neutron source.Here we build a Bragg-edge imaging system on the General Purpose Powder Diffractometer at the China Spallation Neutron Source.The residual strain mapping of a bent Q235 ferrite steel sample has been achieved with a spectral resolution of 0.15%by the time-of-flight neutron Bragg-edge imaging on this system.The results show its great potential applications in materials science and engineering. 展开更多
关键词 neutron Bragg-edge imaging China Spallation neutron Source
下载PDF
Study of the response of 10B-doped MCP to wide-energy range neutrons from eV to MeV
4
作者 Qiang Li Li‑Jiao Wang +76 位作者 Xiang‑Biao Qiu Jing‑Wen Li Wei Xu Tao Li Ze‑Bin Lin Chang‑Jun Ning Yong‑Hao Chen Rui‑Rui Fan Kang Sun Jing‑Yu Tang Rong Zhang Han‑Tao Jing Bo Mei Qi An Hao‑Fan Bai Jiang‑Bo Bai Jie Bao Ping Cao Qi‑Ping Chen Zhen Chen Zeng‑Qi Cui An‑Chuan Fan Chang‑Qing Feng Fan‑Zhen Feng Ke‑Qing Gao Min‑Hao Gu Chang‑Cai Han Zi‑Jie Han Guo‑Zhu He Yong‑Cheng He Yang Hong Yi‑Wei Hu Han‑Xiong Huang Wei‑Hua Jia Hao‑Yu Jiang Wei Jiang Zhi‑Jie Jiang Zheng‑Yao Jin Ling Kang Bo Li Chao Li Gong Li Jia‑Wen Li Xiao Li Yang Li Jie Liu Rong Liu Shu‑Bin Liu Guang‑Yuan Luan Bin‑Bin Qi Jie Ren Zhi‑Zhou Ren Xi‑Chao Ruan Zhao‑Hui Song Zhi‑Xin Tan Sheng‑Da Tang Peng‑Cheng Wang Zhao‑Hui Wang Zhong‑Wei Wen Xiao‑Guang Wu Xuan Wu Li‑Kun Xie Yi‑Wei Yang Han Yi Yong‑Ji Yu Guo‑Hui Zhang Lin‑Hao Zhang Mo‑Han Zhang Qi‑Wei Zhang Xian‑Peng Zhang Yu‑Liang Zhang Yue Zhang Zhi‑Yong Zhang Mao‑Yuan Zhao Lu‑Ping Zhou Zhi‑Hao Zhou Ke‑Jun Zhu 《Nuclear Science and Techniques》 SCIE EI CAS 2024年第8期132-141,共10页
Neutron-sensitive microchannel plates(nMCPs)have applications in neutron detection,including energy spectrum measurements,neutron-induced cross sections,and neutron imaging.10B-doped MCPs(B-MCPs)have attracted signifi... Neutron-sensitive microchannel plates(nMCPs)have applications in neutron detection,including energy spectrum measurements,neutron-induced cross sections,and neutron imaging.10B-doped MCPs(B-MCPs)have attracted significant attention owing to their potential for exhibiting a high neutron detection efficiency over a large neutron energy range.Good spatial and temporal resolutions are useful for neutron energy-resolved imaging.However,their practical applications still face many technical challenges.In this study,a B-MCP with 10 mol%10B was tested for its response to wide-energy neutrons from eV to MeV at the Back-n white neutron source at the China Spallation Neutron Source.The neutron detection efficiency was calibrated at 1 eV,which is approximately 300 times that of an ordinary MCP and indicates the success of 10 B doping.The factors that caused the reduction in the detection efficiency were simulated and discussed.The neutron energy spectrum obtained using B-MCP was compared with that obtained by other measurement methods,and showed very good consistency for neutron energies below tens of keV.The response is more complicated at higher neutron energy,at which point the elastic and nonelastic reactions of all nuclides of B-MCP gradually become dominant.This is beneficial for the detection of neutrons,as it compensates for the detection efficiency of B-MCP for high-energy neutrons. 展开更多
关键词 neutron radiation image 10B-doped MCP neutron response Wide-energy range neutrons
下载PDF
10B-doped MCP detector developed for neutron resonance imaging at Back-n white neutron source
5
作者 Qiang Li Li‑Jiao Wang +70 位作者 Jing‑Yu Tang Xiang‑Biao Qiu Zhen Chen Mao‑Yuan Zhao Chang‑Jun Ning Kai Pan Wei Xu Tao Li Su‑Peng Lu Han Yi Rui‑Rui Fan Chang‑Qing Feng Rong Zhang Xiao‑Yang Sun Qi An Hao‑Fan Bai Jiang‑Bo Bai Jie Bao Ping Cao Qi‑Ping Chen Yong‑Hao Chen Zeng‑Qi Cui An‑Chuan Fan Fan‑Zhen Feng Min‑Hao Gu Chang‑Cai Han Zi‑Jie Han Guo‑Zhu He Yong‑Cheng He Yang Hong Yi‑Wei Hu Han‑Xiong Huang Wei Jiang Zhi‑Jie Jiang Zheng‑Yao Jin Ling Kang Bo Li Gong Li Xiao Li Yang Li Jie Liu Rong Liu Shu‑Bin Liu Yi‑Na Liu Guang‑Yuan Luan Jie Ren Zhi‑Zhou Ren Xi‑Chao Ruan Zhao‑Hui Song Kang Sun Zhi‑Xin Tan Sheng‑Da Tang Jin‑Cheng Wang Peng‑Cheng Wang Zhao‑Hui Wang Zhong‑Wei Wen Xiao‑Guang Wu Xuan Wu Cong Xia Yong‑Ji Yu Guo‑Hui Zhang Hang‑Chang Zhang Lin‑Hao Zhang Qi‑Wei Zhang Xian‑Peng Zhang Yu‑Liang Zhang Yue Zhang Zhi‑Yong Zhang Zhi‑Hao Zhou Ke‑Jun Zhu Chong Zou 《Nuclear Science and Techniques》 SCIE EI CAS 2024年第8期58-68,共11页
Neutron resonance imaging(NRI)has recently emerged as an appealing technique for neutron radiography.Its complexity surpasses that of conventional transmission imaging,as it requires a high demand for both a neutron s... Neutron resonance imaging(NRI)has recently emerged as an appealing technique for neutron radiography.Its complexity surpasses that of conventional transmission imaging,as it requires a high demand for both a neutron source and detector.Consequently,the progression of NRI technology has been sluggish since its inception in the 1980s,particularly considering the limited studies analyzing the neutron energy range above keV.The white neutron source(Back-n)at the China Spallation Neutron Source(CSNS)provides favorable beam conditions for the development of the NRI technique over a wide neutron energy range from eV to MeV.Neutron-sensitive microchannel plates(MCP)have emerged as a cutting-edge tool in the field of neutron detection owing to their high temporal and spatial resolutions,high detection efficiency,and low noise.In this study,we report the development of a 10B-doped MCP detector,along with its associated electronics,data processing system,and NRI experiments at the Back-n.Individual heavy elements such as gold,silver,tungsten,and indium can be easily identified in the transmission images by their characteristic resonance peaks in the 1–100 eV energy range;the more difficult medium-weight elements such as iron,copper,and aluminum with resonance peaks in the 1–100 keV energy range can also be identified.In particular,results in the neutron energy range of dozens of keV(Aluminum)are reported here for the first time. 展开更多
关键词 neutron resonance imaging 10B doped MCP detector White neutron source Sample nuclide identification
下载PDF
High efficiency event-counting thermal neutron imaging using a Gd-doped micro-channel plate 被引量:3
6
作者 田阳 杨祎罡 +2 位作者 潘京生 李玉兰 李元景 《Chinese Physics C》 SCIE CAS CSCD 2014年第8期57-59,共3页
An event-counting thermal neutron imaging detector based on 3 mol % nattGd2O3-doped micro-channel plate (MCP) has been developed and tested. A thermal neutron imaging experiment was carried out with a low flux neutr... An event-counting thermal neutron imaging detector based on 3 mol % nattGd2O3-doped micro-channel plate (MCP) has been developed and tested. A thermal neutron imaging experiment was carried out with a low flux neutron beam. Detection efficiency of 33% was achieved with only one doped MCP. The spatial resolution of 72μ m RMS is currently limited by the readout anode. A detector with larger area and improved readout method is now being developed. 展开更多
关键词 doped MCP thermal neutron imaging event-counting
原文传递
Spontaneous Imbibition of Water and Determination of Effective Contact Angles in the Eagle Ford Shale Formation Using Neutron Imaging 被引量:1
7
作者 Victoria H.DiStefano Michael C.Cheshire +11 位作者 Joanna McFarlane Lindsay M.Kolbus Richard E.Hale Edmund Perfect Hassina Z.Bilheux Louis J.Santodonato Daniel S.Hussey David L.Jacobson Jacob M.LaManna Philip R.Bingham Vitaliy Starchenko Lawrence M.Anovitz 《Journal of Earth Science》 SCIE CAS CSCD 2017年第5期874-887,共14页
Understanding of fundamental processes and prediction of optimal parameters during the horizontal drilling and hydraulic fracturing process results in economically effective improvement of oil and natural gas extracti... Understanding of fundamental processes and prediction of optimal parameters during the horizontal drilling and hydraulic fracturing process results in economically effective improvement of oil and natural gas extraction. Although modern analytical and computational models can capture fracture growth, there is a lack of experimental data on spontaneous imbibition and wettability in oil and gas reservoirs for the validation of further model development. In this work, we used neutron im- aging to measure the spontaneous imbibition of water into fractures of Eagle Ford shale with known geometries and fracture orientations. An analytical solution for a set of nonlinear second-order diffe- rential equations was applied to the measured imbibition data to determine effective contact angles. The analytical solution fit the measured imbibition data reasonably well and determined effective con- tact angles that were slightly higher than static contact angles due to effects of in-situ changes in veloci- ty, surface roughness, and heterogeneity of mineral surfaces on the fracture surface. Additionally, small fracture widths may have retarded imbibition and affected model fits, which suggests that aver- age fracture widths are not satisfactory for modeling imbibition in natural systems. 展开更多
关键词 spontaneous imbibition effective contact angle neutron imaging Eagle Ford shale rock fractures.
原文传递
Revealing the residual stress distribution in laser welded Eurofer97 steel by neutron diffraction and Bragg edge imaging 被引量:1
8
作者 Bin Zhu Nathanael Leung +6 位作者 Winfried Kockelmann Saurabh Kabra Andrew JLondon Michael Gorley Mark JWhiting Yiqiang Wang Tan Sui 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2022年第19期249-260,共12页
Eurofer97 steel is a primary structural material for applications in fusion reactors. Laser welding is a promising technique to join Eurofer97 plasma-facing components and overcome remote handling and maintenance chal... Eurofer97 steel is a primary structural material for applications in fusion reactors. Laser welding is a promising technique to join Eurofer97 plasma-facing components and overcome remote handling and maintenance challenges. The interaction of the induced residual stress and the heterogeneous microstructure degrades the mechanical performance of such fusion components. The present study investigates the distribution of residual stress in as-welded and post-heat treated Eurofer97 joints. The mechanistic connections between microstructure, material properties, and residual stress are also studied. Neutron diffraction is used to study the through-thickness residual stress distribution in three directions,and neutron Bragg edge imaging(NBEI) is applied to study the residual strain in high spatial resolution.The microstructures and micro-hardness are characterised by electron backscatter diffraction and nanoindentation, respectively. The M-shaped residual stress distribution through the thickness of the as-welded weldment is observed by neutron diffraction line scans over a region of 1.41 × 10 mm^(2). These profiles are cross-validated over a larger area(∼56 × 40 mm^(2)) with the higher spatial resolution by NBEI. The micro-hardness value in the fusion zone of the as-welded sample almost doubles from 2.75 ± 0.09 GPa to 5.06 ± 0.29 GPa due to a combination of residual stress and cooling-induced martensite. Conventional post weld heat treatment(PWHT) is shown to release ∼90% of the residual stress but not fully restore the microstructure. By comparing its hardness with that of stress-free samples, it is found that the microstructure is the primary contribution to the hardening. This study provides insight into the prediction of structural integrity for critical structural components of fusion reactors. 展开更多
关键词 Laser-welded Eurofer97 steel Residual stress neutron diffraction neutron Bragg edge imaging Nanoindentation EBSD
原文传递
A simulation study of a high-resolution fast neutron imaging detector based on liquid scintillator loaded capillaries
9
作者 Zhiyong Song Shifeng Sun Xiaoping Ouyang 《Radiation Detection Technology and Methods》 CSCD 2020年第2期153-160,共8页
Background At present,the highest spatial resolution of a fast neutron imaging detector,mainly determined by the range of secondary particles generated by fast neutrons,is about hundreds of microns.In view of the abov... Background At present,the highest spatial resolution of a fast neutron imaging detector,mainly determined by the range of secondary particles generated by fast neutrons,is about hundreds of microns.In view of the above inherent spatial resolution limitation,a capillary-based scintillation detector that can improve the spatial resolution of fast neutron imaging by recording and reconstructing the recoil proton track was developed.Purpose The purpose of this paper is to develop a detector for recognizing recoil proton events,reconstructing particle track and improving the position resolution with track reconstruction method to reconstruct the position of interaction.Methods The proposed detector consists of a 1000×1000 array of glass capillaries loaded with a high refractive index liquid scintillator.Each glass capillary was 10μm in diameter and 5 cm in length.The recoil protons generated by the incident neutrons move within the detector and produce scintillation light within each capillary that they traverse.The light emitted from the capillary array can be recorded by employing an intensified CCD camera.We used Geant4 to simulate the detector performance and CERN ROOT analysis framework to record physical information of recoil proton,including position,energy deposition in each capillary and track length.Based on Hough transform,a rapid,computerized and efficient proton track reconstruction procedure was developed.Conclusion The recoil proton events display a continuous extended structure.The track reconstruction algorithms can reconstruct individual track precisely,and when the counting rate was relatively low,the track reconstruction results were in good agreement with simulation data.Moreover,for intensive overlap conditions,this algorithm also reconstructs periphery tracks with high rate of accuracy. 展开更多
关键词 Fast neutron imaging Glass capillary Track reconstruction Hough transform
原文传递
Neutron transmission imaging with a portable D-T neutron generator
10
作者 Phillip Kerr Nerine Cherepy +9 位作者 Jennifer Church Gary Guethlein Jim Hall Colby McNamee Sean o'Neal Kyle Champley Andy Townsend Mayuki Sasagawa Anthony Hardy Saphon Hok 《Radiation Detection Technology and Methods》 CSCD 2022年第2期234-243,共10页
Purpose A portable fast-neutron imaging system is being developed to provide complementary information to field X-ray imaging.Applications include inspection of vehicles and infrastructure for corrosion,measurement of... Purpose A portable fast-neutron imaging system is being developed to provide complementary information to field X-ray imaging.Applications include inspection of vehicles and infrastructure for corrosion,measurement of material levels in containers,and inspection of munitions and suspicious packages.While fast-neuron imaging generally provides lower imaging resolution compared to X-rays,fast-neutron interaction cross-sections have a weak dependence on material Z.This enables imaging of low-Z materials inside high-Z materials.Here,we discuss the limitations and current improvements in fast-neuron imaging.Methods Limitations in portable fast-neutron imaging systems include low D-T neutron generator output,low light pro-duction in ZnS(Cu)imaging scintillators,low resolution due to scintillator thickness and D-T spot size,and digital-panel darknoise that varies in time and position and that can be 100×larger than the neutron signal.We have made improvements in these areas through development of a segmented high light yield scintillator,panel noise mitigation techniques,and testing of new high-output,small spot size D-T neutron generators.Results The segmented high light yield fast-neutron scintillator demonstrated 5×increase in light compared to ZnS(Cu).An additional 2×improvement in signal-to-noise was demonstrated with panel-noise mitigation techniques.Our MCNP calculations also show good agreement with neutron imaging results Conclusions We have demonstrated improvements in fast-neutron imaging through development of a segmented high light yield neutron scintillator,mitigation of digital panel noise,and preliminary testing with new high-output,small spot size D-T neutron generators.We have also demonstrated good results modeling fast-neutron images and scatter effects using MCNP. 展开更多
关键词 Fast-neutron radiography Portable neutron imaging neutron scintillators Monte Carlo simulation
原文传递
New Opportunities for Neutrons in Environmental and Biological Sciences
11
作者 Alexander Johs Shuo Qian +8 位作者 Leighton Coates Brian H.Davison James G.Elkins Xin Gu Jennifer Morrell-Falvey Hugh O'Neill Jeffrey M.Warren Eric M.Pierce Kenneth Herwig 《Frontiers of Environmental Science & Engineering》 SCIE EI 2024年第7期179-186,共8页
The use of neutron methods in environmental and biological sciences is rapidly emerging and accelerating with the development of new instruments at neutron user facilities.This article,based on a workshop held at Oak ... The use of neutron methods in environmental and biological sciences is rapidly emerging and accelerating with the development of new instruments at neutron user facilities.This article,based on a workshop held at Oak Ridge National Laboratory(ORNL),offers insights into the application of neutron techniques in environmental and biological sciences.We highlight recent advances and identify key challenges and potential future research areas.These include soil and rhizosphere processes,root water dynamics,plant-microbe interactions,structure and dynamics of biological systems,applications in synthetic biology and enzyme engineering,next-generation bioproducts,biomaterials and bioenergy,nanoscale structure,and fluid dynamics of porous materials in geochemistry.We provide an outlook on emerging opportunities with an emphasis on new capabilities that will be enabled at the Spallation Neutron Source Second Target Station currently under design at ORNL.The mission of scientific neutron user facilities worldwide is to enable science using state-of-the-art neutron capabilities.We aim to encourage researchers in the environmental and biological research community to explore the unique capability afforded by neutrons at these facilities. 展开更多
关键词 neutrons Environment Biology neutron imaging neutron scattering Second Target Station(STS)
原文传递
Compact MPPC-based coded aperture imaging camera for dual-particle detection 被引量:2
12
作者 Jing Guo Xiaoyu Pang +9 位作者 Jiale Cai Daowu Li Xiaoming Wang Xuanhou Hu Yue Yu Shuangquan Liu Xiuzuo Liang Yiwen Zhang Lei Shuai Long Wei 《Radiation Detection Technology and Methods》 CSCD 2021年第1期61-70,共10页
Purpose Fast neutrons and gamma-ray imaging detection is an effective way to detect and identify radioactive material in the field of nuclear security.A compact coded aperture imaging(CAI)camera was designed to be sen... Purpose Fast neutrons and gamma-ray imaging detection is an effective way to detect and identify radioactive material in the field of nuclear security.A compact coded aperture imaging(CAI)camera was designed to be sensitive to both gamma and neutron radiation based on plastic scintillators and multi-pixel photon counters(MPPC).Methods MPPCs coupling with the 13×13 pixelated plastic scintillators one-to-one were utilized to reduce the scale of the CAI system while maintaining good positional performance.The symmetric charge division(SCD)circuit was adopted to reduce the 169 signals output from the MPPC array to 26.Each waveform was collected and processed with four Domino Ring Sampler 4(DRS4)chips and two 16-channel analog-to-digital converter(ADC)modules.As the pulse shapes of fast neutrons would be broadened after elastic scattering multiple times in the scintillators,the Anger-Logic method was applied to eliminate multiple elastic scattering events so that good pulse shape discrimination(PSD)performance can be achieved.Results The imaging and detection ability of the camerawas evaluated using the 241Am-Be(5.9×10^(5) n/s)neutron source and 137Cs(370 MBq)gammasource.The camera can be used to detect fast neutrons(0.5–10 MeV)and gammarays(0.2–2.5MeV).Furthermore,it can implement efficient neutron/gamma PSD capabilities in the mixed-field environment.The figure of merit(FOM)of the camera calculated at 400keVee energy cut is 0.93.Conclusion A compact MPPC-based CAI camera was designed to detect and discriminate fast neutrons and gamma rays.Its good PSD performance was well suited to distinguish fast neutrons from gamma rays in a dual-particle environment.The portable design makes it promising for complex monitoring scenarios in nuclear security. 展开更多
关键词 Coded aperture imaging Fast neutron imaging Gamma imaging n-γdiscrimination
原文传递
上一页 1 下一页 到第