As a non-destructive testing technology,neutron imaging plays an important role in various fields,including material science,nuclear engineering,and fundamental science.An imaging detector with a neutron-sensitive ima...As a non-destructive testing technology,neutron imaging plays an important role in various fields,including material science,nuclear engineering,and fundamental science.An imaging detector with a neutron-sensitive image intensifier has been developed and demonstrated to achieve good spatial resolution and timing resolution.However,the influence of the working voltage on the performance of the neutron-sensitive imaging intensifier has not been studied.To optimize the performance of the neutron-sensitive image intensifier at different voltages,experiments have been performed at the China Spallation Neutron Source(CSNS)neutron beamline.The change in the light yield and imaging quality with different voltages has been acquired.It is shown that the image quality benefits from the high gain of the microchannel plate(MCP)and the high accelerating electric field between the MCP and the screen.Increasing the accelerating electric field is more effective than increasing the gain of MCPs for the improvement of the imaging quality.Increasing the total gain of the MCP stack can be realized more effectively by improving the gain of the standard MCP than that of the n MCP.These results offer a development direction for image intensifiers in the future.展开更多
An event-counting thermal neutron imaging detector based on 3 mol % nattGd2O3-doped micro-channel plate (MCP) has been developed and tested. A thermal neutron imaging experiment was carried out with a low flux neutr...An event-counting thermal neutron imaging detector based on 3 mol % nattGd2O3-doped micro-channel plate (MCP) has been developed and tested. A thermal neutron imaging experiment was carried out with a low flux neutron beam. Detection efficiency of 33% was achieved with only one doped MCP. The spatial resolution of 72μ m RMS is currently limited by the readout anode. A detector with larger area and improved readout method is now being developed.展开更多
Understanding of fundamental processes and prediction of optimal parameters during the horizontal drilling and hydraulic fracturing process results in economically effective improvement of oil and natural gas extracti...Understanding of fundamental processes and prediction of optimal parameters during the horizontal drilling and hydraulic fracturing process results in economically effective improvement of oil and natural gas extraction. Although modern analytical and computational models can capture fracture growth, there is a lack of experimental data on spontaneous imbibition and wettability in oil and gas reservoirs for the validation of further model development. In this work, we used neutron im- aging to measure the spontaneous imbibition of water into fractures of Eagle Ford shale with known geometries and fracture orientations. An analytical solution for a set of nonlinear second-order diffe- rential equations was applied to the measured imbibition data to determine effective contact angles. The analytical solution fit the measured imbibition data reasonably well and determined effective con- tact angles that were slightly higher than static contact angles due to effects of in-situ changes in veloci- ty, surface roughness, and heterogeneity of mineral surfaces on the fracture surface. Additionally, small fracture widths may have retarded imbibition and affected model fits, which suggests that aver- age fracture widths are not satisfactory for modeling imbibition in natural systems.展开更多
Background At present,the highest spatial resolution of a fast neutron imaging detector,mainly determined by the range of secondary particles generated by fast neutrons,is about hundreds of microns.In view of the abov...Background At present,the highest spatial resolution of a fast neutron imaging detector,mainly determined by the range of secondary particles generated by fast neutrons,is about hundreds of microns.In view of the above inherent spatial resolution limitation,a capillary-based scintillation detector that can improve the spatial resolution of fast neutron imaging by recording and reconstructing the recoil proton track was developed.Purpose The purpose of this paper is to develop a detector for recognizing recoil proton events,reconstructing particle track and improving the position resolution with track reconstruction method to reconstruct the position of interaction.Methods The proposed detector consists of a 1000×1000 array of glass capillaries loaded with a high refractive index liquid scintillator.Each glass capillary was 10μm in diameter and 5 cm in length.The recoil protons generated by the incident neutrons move within the detector and produce scintillation light within each capillary that they traverse.The light emitted from the capillary array can be recorded by employing an intensified CCD camera.We used Geant4 to simulate the detector performance and CERN ROOT analysis framework to record physical information of recoil proton,including position,energy deposition in each capillary and track length.Based on Hough transform,a rapid,computerized and efficient proton track reconstruction procedure was developed.Conclusion The recoil proton events display a continuous extended structure.The track reconstruction algorithms can reconstruct individual track precisely,and when the counting rate was relatively low,the track reconstruction results were in good agreement with simulation data.Moreover,for intensive overlap conditions,this algorithm also reconstructs periphery tracks with high rate of accuracy.展开更多
The neutron Bragg-edge imaging is expected to be a new non-destructive energy-resolved neutron imaging technique for quantitatively two-dimensional or three-dimensional visualizing crystallographic information in a bu...The neutron Bragg-edge imaging is expected to be a new non-destructive energy-resolved neutron imaging technique for quantitatively two-dimensional or three-dimensional visualizing crystallographic information in a bulk material,which could be benefited from pulsed neutron source.Here we build a Bragg-edge imaging system on the General Purpose Powder Diffractometer at the China Spallation Neutron Source.The residual strain mapping of a bent Q235 ferrite steel sample has been achieved with a spectral resolution of 0.15%by the time-of-flight neutron Bragg-edge imaging on this system.The results show its great potential applications in materials science and engineering.展开更多
Neutron resonance imaging(NRI)has recently emerged as an appealing technique for neutron radiography.Its complexity surpasses that of conventional transmission imaging,as it requires a high demand for both a neutron s...Neutron resonance imaging(NRI)has recently emerged as an appealing technique for neutron radiography.Its complexity surpasses that of conventional transmission imaging,as it requires a high demand for both a neutron source and detector.Consequently,the progression of NRI technology has been sluggish since its inception in the 1980s,particularly considering the limited studies analyzing the neutron energy range above keV.The white neutron source(Back-n)at the China Spallation Neutron Source(CSNS)provides favorable beam conditions for the development of the NRI technique over a wide neutron energy range from eV to MeV.Neutron-sensitive microchannel plates(MCP)have emerged as a cutting-edge tool in the field of neutron detection owing to their high temporal and spatial resolutions,high detection efficiency,and low noise.In this study,we report the development of a 10B-doped MCP detector,along with its associated electronics,data processing system,and NRI experiments at the Back-n.Individual heavy elements such as gold,silver,tungsten,and indium can be easily identified in the transmission images by their characteristic resonance peaks in the 1–100 eV energy range;the more difficult medium-weight elements such as iron,copper,and aluminum with resonance peaks in the 1–100 keV energy range can also be identified.In particular,results in the neutron energy range of dozens of keV(Aluminum)are reported here for the first time.展开更多
Neutron-sensitive microchannel plates(nMCPs)have applications in neutron detection,including energy spectrum measurements,neutron-induced cross sections,and neutron imaging.10B-doped MCPs(B-MCPs)have attracted signifi...Neutron-sensitive microchannel plates(nMCPs)have applications in neutron detection,including energy spectrum measurements,neutron-induced cross sections,and neutron imaging.10B-doped MCPs(B-MCPs)have attracted significant attention owing to their potential for exhibiting a high neutron detection efficiency over a large neutron energy range.Good spatial and temporal resolutions are useful for neutron energy-resolved imaging.However,their practical applications still face many technical challenges.In this study,a B-MCP with 10 mol%10B was tested for its response to wide-energy neutrons from eV to MeV at the Back-n white neutron source at the China Spallation Neutron Source.The neutron detection efficiency was calibrated at 1 eV,which is approximately 300 times that of an ordinary MCP and indicates the success of 10 B doping.The factors that caused the reduction in the detection efficiency were simulated and discussed.The neutron energy spectrum obtained using B-MCP was compared with that obtained by other measurement methods,and showed very good consistency for neutron energies below tens of keV.The response is more complicated at higher neutron energy,at which point the elastic and nonelastic reactions of all nuclides of B-MCP gradually become dominant.This is beneficial for the detection of neutrons,as it compensates for the detection efficiency of B-MCP for high-energy neutrons.展开更多
Purpose A portable fast-neutron imaging system is being developed to provide complementary information to field X-ray imaging.Applications include inspection of vehicles and infrastructure for corrosion,measurement of...Purpose A portable fast-neutron imaging system is being developed to provide complementary information to field X-ray imaging.Applications include inspection of vehicles and infrastructure for corrosion,measurement of material levels in containers,and inspection of munitions and suspicious packages.While fast-neuron imaging generally provides lower imaging resolution compared to X-rays,fast-neutron interaction cross-sections have a weak dependence on material Z.This enables imaging of low-Z materials inside high-Z materials.Here,we discuss the limitations and current improvements in fast-neuron imaging.Methods Limitations in portable fast-neutron imaging systems include low D-T neutron generator output,low light pro-duction in ZnS(Cu)imaging scintillators,low resolution due to scintillator thickness and D-T spot size,and digital-panel darknoise that varies in time and position and that can be 100×larger than the neutron signal.We have made improvements in these areas through development of a segmented high light yield scintillator,panel noise mitigation techniques,and testing of new high-output,small spot size D-T neutron generators.Results The segmented high light yield fast-neutron scintillator demonstrated 5×increase in light compared to ZnS(Cu).An additional 2×improvement in signal-to-noise was demonstrated with panel-noise mitigation techniques.Our MCNP calculations also show good agreement with neutron imaging results Conclusions We have demonstrated improvements in fast-neutron imaging through development of a segmented high light yield neutron scintillator,mitigation of digital panel noise,and preliminary testing with new high-output,small spot size D-T neutron generators.We have also demonstrated good results modeling fast-neutron images and scatter effects using MCNP.展开更多
When neutron yield is very low, reconstruction of coding penumbra image is rather difficult. In this paper, low-yield (109) 14 MeV neutron penumbra imaging was simulated by Monte Carlo method. The Richardson Lucy (...When neutron yield is very low, reconstruction of coding penumbra image is rather difficult. In this paper, low-yield (109) 14 MeV neutron penumbra imaging was simulated by Monte Carlo method. The Richardson Lucy (R-L) iteration method was proposed to incorporated with Bayesian least square-Gaussian scale mixture model (BLS-GSM) wavelet denoising for the simulated image. Optimal number of R-L iterations was gotten by a large number of tests. The results show that compared with Wiener method and median filter denoising, this method is better in restraining background noise, the correlation coefficient Rsr between the reconstructed and the real images is larger, and the reconstruction result is better.展开更多
Eurofer97 steel is a primary structural material for applications in fusion reactors. Laser welding is a promising technique to join Eurofer97 plasma-facing components and overcome remote handling and maintenance chal...Eurofer97 steel is a primary structural material for applications in fusion reactors. Laser welding is a promising technique to join Eurofer97 plasma-facing components and overcome remote handling and maintenance challenges. The interaction of the induced residual stress and the heterogeneous microstructure degrades the mechanical performance of such fusion components. The present study investigates the distribution of residual stress in as-welded and post-heat treated Eurofer97 joints. The mechanistic connections between microstructure, material properties, and residual stress are also studied. Neutron diffraction is used to study the through-thickness residual stress distribution in three directions,and neutron Bragg edge imaging(NBEI) is applied to study the residual strain in high spatial resolution.The microstructures and micro-hardness are characterised by electron backscatter diffraction and nanoindentation, respectively. The M-shaped residual stress distribution through the thickness of the as-welded weldment is observed by neutron diffraction line scans over a region of 1.41 × 10 mm^(2). These profiles are cross-validated over a larger area(∼56 × 40 mm^(2)) with the higher spatial resolution by NBEI. The micro-hardness value in the fusion zone of the as-welded sample almost doubles from 2.75 ± 0.09 GPa to 5.06 ± 0.29 GPa due to a combination of residual stress and cooling-induced martensite. Conventional post weld heat treatment(PWHT) is shown to release ∼90% of the residual stress but not fully restore the microstructure. By comparing its hardness with that of stress-free samples, it is found that the microstructure is the primary contribution to the hardening. This study provides insight into the prediction of structural integrity for critical structural components of fusion reactors.展开更多
Purpose Fast neutrons and gamma-ray imaging detection is an effective way to detect and identify radioactive material in the field of nuclear security.A compact coded aperture imaging(CAI)camera was designed to be sen...Purpose Fast neutrons and gamma-ray imaging detection is an effective way to detect and identify radioactive material in the field of nuclear security.A compact coded aperture imaging(CAI)camera was designed to be sensitive to both gamma and neutron radiation based on plastic scintillators and multi-pixel photon counters(MPPC).Methods MPPCs coupling with the 13×13 pixelated plastic scintillators one-to-one were utilized to reduce the scale of the CAI system while maintaining good positional performance.The symmetric charge division(SCD)circuit was adopted to reduce the 169 signals output from the MPPC array to 26.Each waveform was collected and processed with four Domino Ring Sampler 4(DRS4)chips and two 16-channel analog-to-digital converter(ADC)modules.As the pulse shapes of fast neutrons would be broadened after elastic scattering multiple times in the scintillators,the Anger-Logic method was applied to eliminate multiple elastic scattering events so that good pulse shape discrimination(PSD)performance can be achieved.Results The imaging and detection ability of the camerawas evaluated using the 241Am-Be(5.9×10^(5) n/s)neutron source and 137Cs(370 MBq)gammasource.The camera can be used to detect fast neutrons(0.5–10 MeV)and gammarays(0.2–2.5MeV).Furthermore,it can implement efficient neutron/gamma PSD capabilities in the mixed-field environment.The figure of merit(FOM)of the camera calculated at 400keVee energy cut is 0.93.Conclusion A compact MPPC-based CAI camera was designed to detect and discriminate fast neutrons and gamma rays.Its good PSD performance was well suited to distinguish fast neutrons from gamma rays in a dual-particle environment.The portable design makes it promising for complex monitoring scenarios in nuclear security.展开更多
The use of neutron methods in environmental and biological sciences is rapidly emerging and accelerating with the development of new instruments at neutron user facilities.This article,based on a workshop held at Oak ...The use of neutron methods in environmental and biological sciences is rapidly emerging and accelerating with the development of new instruments at neutron user facilities.This article,based on a workshop held at Oak Ridge National Laboratory(ORNL),offers insights into the application of neutron techniques in environmental and biological sciences.We highlight recent advances and identify key challenges and potential future research areas.These include soil and rhizosphere processes,root water dynamics,plant-microbe interactions,structure and dynamics of biological systems,applications in synthetic biology and enzyme engineering,next-generation bioproducts,biomaterials and bioenergy,nanoscale structure,and fluid dynamics of porous materials in geochemistry.We provide an outlook on emerging opportunities with an emphasis on new capabilities that will be enabled at the Spallation Neutron Source Second Target Station currently under design at ORNL.The mission of scientific neutron user facilities worldwide is to enable science using state-of-the-art neutron capabilities.We aim to encourage researchers in the environmental and biological research community to explore the unique capability afforded by neutrons at these facilities.展开更多
基金Project supported by the National Key R&D Program of China (Grant Nos.2023YFC2206502 and 2021YFA1600703)the National Natural Science Foundation of China (Grant Nos.12175254 and 12227810)the Guangdong–Hong Kong–Macao Joint Laboratory for Neutron Scattering Science and Technology。
文摘As a non-destructive testing technology,neutron imaging plays an important role in various fields,including material science,nuclear engineering,and fundamental science.An imaging detector with a neutron-sensitive image intensifier has been developed and demonstrated to achieve good spatial resolution and timing resolution.However,the influence of the working voltage on the performance of the neutron-sensitive imaging intensifier has not been studied.To optimize the performance of the neutron-sensitive image intensifier at different voltages,experiments have been performed at the China Spallation Neutron Source(CSNS)neutron beamline.The change in the light yield and imaging quality with different voltages has been acquired.It is shown that the image quality benefits from the high gain of the microchannel plate(MCP)and the high accelerating electric field between the MCP and the screen.Increasing the accelerating electric field is more effective than increasing the gain of MCPs for the improvement of the imaging quality.Increasing the total gain of the MCP stack can be realized more effectively by improving the gain of the standard MCP than that of the n MCP.These results offer a development direction for image intensifiers in the future.
基金Supported by National Natural Science Foundation of China(10735020,11075026)
文摘An event-counting thermal neutron imaging detector based on 3 mol % nattGd2O3-doped micro-channel plate (MCP) has been developed and tested. A thermal neutron imaging experiment was carried out with a low flux neutron beam. Detection efficiency of 33% was achieved with only one doped MCP. The spatial resolution of 72μ m RMS is currently limited by the readout anode. A detector with larger area and improved readout method is now being developed.
基金supported as part of the Center for Nanoscale Controls on Geologic CO_2 (NCGC)an Energy Frontier Research Center funded by the U.S. Department of Energy, Office of Science, Basic Energy Sciences (No. DE-AC0205CH11231)+2 种基金a graduate fellowship through the Bredesen Center for Interdisciplinary Research at the University of Tennesseesupported by the U.S. Department of Energy, Office of Science, Office of Basic Energy Sciences, Chemical Sciences, Geosciences, and Biosciences DivisionEdmund Perfect ’s research was sponsored by the Army Research Laboratory (No.W911NF-16-1-0043)
文摘Understanding of fundamental processes and prediction of optimal parameters during the horizontal drilling and hydraulic fracturing process results in economically effective improvement of oil and natural gas extraction. Although modern analytical and computational models can capture fracture growth, there is a lack of experimental data on spontaneous imbibition and wettability in oil and gas reservoirs for the validation of further model development. In this work, we used neutron im- aging to measure the spontaneous imbibition of water into fractures of Eagle Ford shale with known geometries and fracture orientations. An analytical solution for a set of nonlinear second-order diffe- rential equations was applied to the measured imbibition data to determine effective contact angles. The analytical solution fit the measured imbibition data reasonably well and determined effective con- tact angles that were slightly higher than static contact angles due to effects of in-situ changes in veloci- ty, surface roughness, and heterogeneity of mineral surfaces on the fracture surface. Additionally, small fracture widths may have retarded imbibition and affected model fits, which suggests that aver- age fracture widths are not satisfactory for modeling imbibition in natural systems.
基金This work was supported by the National Nature Science Foundation of China(Contract No.11805066).
文摘Background At present,the highest spatial resolution of a fast neutron imaging detector,mainly determined by the range of secondary particles generated by fast neutrons,is about hundreds of microns.In view of the above inherent spatial resolution limitation,a capillary-based scintillation detector that can improve the spatial resolution of fast neutron imaging by recording and reconstructing the recoil proton track was developed.Purpose The purpose of this paper is to develop a detector for recognizing recoil proton events,reconstructing particle track and improving the position resolution with track reconstruction method to reconstruct the position of interaction.Methods The proposed detector consists of a 1000×1000 array of glass capillaries loaded with a high refractive index liquid scintillator.Each glass capillary was 10μm in diameter and 5 cm in length.The recoil protons generated by the incident neutrons move within the detector and produce scintillation light within each capillary that they traverse.The light emitted from the capillary array can be recorded by employing an intensified CCD camera.We used Geant4 to simulate the detector performance and CERN ROOT analysis framework to record physical information of recoil proton,including position,energy deposition in each capillary and track length.Based on Hough transform,a rapid,computerized and efficient proton track reconstruction procedure was developed.Conclusion The recoil proton events display a continuous extended structure.The track reconstruction algorithms can reconstruct individual track precisely,and when the counting rate was relatively low,the track reconstruction results were in good agreement with simulation data.Moreover,for intensive overlap conditions,this algorithm also reconstructs periphery tracks with high rate of accuracy.
基金Project supported by the National Key Research and Development Program of China(Grant Nos.2017YFB0701903 and 2016YFA0401502)the National Natural Science Foundation of China(Grant No.12041202)+2 种基金the Youth Innovation Promotion Association of Chinese Academy of Sciences(Grant No.2017023)the Guangdong Natural Science Foundation,China(Grant No.2016A030313129)the Department of Science and Technology of Guangdong Province under grant project of energy-resolved neutron imaging instrument.
文摘The neutron Bragg-edge imaging is expected to be a new non-destructive energy-resolved neutron imaging technique for quantitatively two-dimensional or three-dimensional visualizing crystallographic information in a bulk material,which could be benefited from pulsed neutron source.Here we build a Bragg-edge imaging system on the General Purpose Powder Diffractometer at the China Spallation Neutron Source.The residual strain mapping of a bent Q235 ferrite steel sample has been achieved with a spectral resolution of 0.15%by the time-of-flight neutron Bragg-edge imaging on this system.The results show its great potential applications in materials science and engineering.
基金supported by the National Natural Science Foundation of China(No.12035017)the Guangdong Basic and Applied Basic Research Foundation(No.2023A1515030074)。
文摘Neutron resonance imaging(NRI)has recently emerged as an appealing technique for neutron radiography.Its complexity surpasses that of conventional transmission imaging,as it requires a high demand for both a neutron source and detector.Consequently,the progression of NRI technology has been sluggish since its inception in the 1980s,particularly considering the limited studies analyzing the neutron energy range above keV.The white neutron source(Back-n)at the China Spallation Neutron Source(CSNS)provides favorable beam conditions for the development of the NRI technique over a wide neutron energy range from eV to MeV.Neutron-sensitive microchannel plates(MCP)have emerged as a cutting-edge tool in the field of neutron detection owing to their high temporal and spatial resolutions,high detection efficiency,and low noise.In this study,we report the development of a 10B-doped MCP detector,along with its associated electronics,data processing system,and NRI experiments at the Back-n.Individual heavy elements such as gold,silver,tungsten,and indium can be easily identified in the transmission images by their characteristic resonance peaks in the 1–100 eV energy range;the more difficult medium-weight elements such as iron,copper,and aluminum with resonance peaks in the 1–100 keV energy range can also be identified.In particular,results in the neutron energy range of dozens of keV(Aluminum)are reported here for the first time.
基金supported by the Guangdong Basic and Applied Basic Research Foundation(No.2023A1515030074)the National Natural Science Foundation of China(No.12035017)。
文摘Neutron-sensitive microchannel plates(nMCPs)have applications in neutron detection,including energy spectrum measurements,neutron-induced cross sections,and neutron imaging.10B-doped MCPs(B-MCPs)have attracted significant attention owing to their potential for exhibiting a high neutron detection efficiency over a large neutron energy range.Good spatial and temporal resolutions are useful for neutron energy-resolved imaging.However,their practical applications still face many technical challenges.In this study,a B-MCP with 10 mol%10B was tested for its response to wide-energy neutrons from eV to MeV at the Back-n white neutron source at the China Spallation Neutron Source.The neutron detection efficiency was calibrated at 1 eV,which is approximately 300 times that of an ordinary MCP and indicates the success of 10 B doping.The factors that caused the reduction in the detection efficiency were simulated and discussed.The neutron energy spectrum obtained using B-MCP was compared with that obtained by other measurement methods,and showed very good consistency for neutron energies below tens of keV.The response is more complicated at higher neutron energy,at which point the elastic and nonelastic reactions of all nuclides of B-MCP gradually become dominant.This is beneficial for the detection of neutrons,as it compensates for the detection efficiency of B-MCP for high-energy neutrons.
基金supported by the US DOE NNSA NA-22,NA-84,and LLNL-LDRD 20-SI-001performed under the auspices of the U.S.Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344
文摘Purpose A portable fast-neutron imaging system is being developed to provide complementary information to field X-ray imaging.Applications include inspection of vehicles and infrastructure for corrosion,measurement of material levels in containers,and inspection of munitions and suspicious packages.While fast-neuron imaging generally provides lower imaging resolution compared to X-rays,fast-neutron interaction cross-sections have a weak dependence on material Z.This enables imaging of low-Z materials inside high-Z materials.Here,we discuss the limitations and current improvements in fast-neuron imaging.Methods Limitations in portable fast-neutron imaging systems include low D-T neutron generator output,low light pro-duction in ZnS(Cu)imaging scintillators,low resolution due to scintillator thickness and D-T spot size,and digital-panel darknoise that varies in time and position and that can be 100×larger than the neutron signal.We have made improvements in these areas through development of a segmented high light yield scintillator,panel noise mitigation techniques,and testing of new high-output,small spot size D-T neutron generators.Results The segmented high light yield fast-neutron scintillator demonstrated 5×increase in light compared to ZnS(Cu).An additional 2×improvement in signal-to-noise was demonstrated with panel-noise mitigation techniques.Our MCNP calculations also show good agreement with neutron imaging results Conclusions We have demonstrated improvements in fast-neutron imaging through development of a segmented high light yield neutron scintillator,mitigation of digital panel noise,and preliminary testing with new high-output,small spot size D-T neutron generators.We have also demonstrated good results modeling fast-neutron images and scatter effects using MCNP.
基金supported by National Natural Science Foundation of China(No.11105106)
文摘When neutron yield is very low, reconstruction of coding penumbra image is rather difficult. In this paper, low-yield (109) 14 MeV neutron penumbra imaging was simulated by Monte Carlo method. The Richardson Lucy (R-L) iteration method was proposed to incorporated with Bayesian least square-Gaussian scale mixture model (BLS-GSM) wavelet denoising for the simulated image. Optimal number of R-L iterations was gotten by a large number of tests. The results show that compared with Wiener method and median filter denoising, this method is better in restraining background noise, the correlation coefficient Rsr between the reconstructed and the real images is larger, and the reconstruction result is better.
文摘Eurofer97 steel is a primary structural material for applications in fusion reactors. Laser welding is a promising technique to join Eurofer97 plasma-facing components and overcome remote handling and maintenance challenges. The interaction of the induced residual stress and the heterogeneous microstructure degrades the mechanical performance of such fusion components. The present study investigates the distribution of residual stress in as-welded and post-heat treated Eurofer97 joints. The mechanistic connections between microstructure, material properties, and residual stress are also studied. Neutron diffraction is used to study the through-thickness residual stress distribution in three directions,and neutron Bragg edge imaging(NBEI) is applied to study the residual strain in high spatial resolution.The microstructures and micro-hardness are characterised by electron backscatter diffraction and nanoindentation, respectively. The M-shaped residual stress distribution through the thickness of the as-welded weldment is observed by neutron diffraction line scans over a region of 1.41 × 10 mm^(2). These profiles are cross-validated over a larger area(∼56 × 40 mm^(2)) with the higher spatial resolution by NBEI. The micro-hardness value in the fusion zone of the as-welded sample almost doubles from 2.75 ± 0.09 GPa to 5.06 ± 0.29 GPa due to a combination of residual stress and cooling-induced martensite. Conventional post weld heat treatment(PWHT) is shown to release ∼90% of the residual stress but not fully restore the microstructure. By comparing its hardness with that of stress-free samples, it is found that the microstructure is the primary contribution to the hardening. This study provides insight into the prediction of structural integrity for critical structural components of fusion reactors.
基金the MajorDeployment Projects of Chinese Academy of Sciences(Grant Number ZDRWCN-2018-1-01)the Research Equipment Development Project of Chinese Academy of Sciences(Grant Number YZ201415).
文摘Purpose Fast neutrons and gamma-ray imaging detection is an effective way to detect and identify radioactive material in the field of nuclear security.A compact coded aperture imaging(CAI)camera was designed to be sensitive to both gamma and neutron radiation based on plastic scintillators and multi-pixel photon counters(MPPC).Methods MPPCs coupling with the 13×13 pixelated plastic scintillators one-to-one were utilized to reduce the scale of the CAI system while maintaining good positional performance.The symmetric charge division(SCD)circuit was adopted to reduce the 169 signals output from the MPPC array to 26.Each waveform was collected and processed with four Domino Ring Sampler 4(DRS4)chips and two 16-channel analog-to-digital converter(ADC)modules.As the pulse shapes of fast neutrons would be broadened after elastic scattering multiple times in the scintillators,the Anger-Logic method was applied to eliminate multiple elastic scattering events so that good pulse shape discrimination(PSD)performance can be achieved.Results The imaging and detection ability of the camerawas evaluated using the 241Am-Be(5.9×10^(5) n/s)neutron source and 137Cs(370 MBq)gammasource.The camera can be used to detect fast neutrons(0.5–10 MeV)and gammarays(0.2–2.5MeV).Furthermore,it can implement efficient neutron/gamma PSD capabilities in the mixed-field environment.The figure of merit(FOM)of the camera calculated at 400keVee energy cut is 0.93.Conclusion A compact MPPC-based CAI camera was designed to detect and discriminate fast neutrons and gamma rays.Its good PSD performance was well suited to distinguish fast neutrons from gamma rays in a dual-particle environment.The portable design makes it promising for complex monitoring scenarios in nuclear security.
基金This work was supported in part by the Spallation Neutron Source Second Target Station Project at ORNL and the Biological and Environmental Research Program(ERKP752 and ERKP291)with in the Office of Science of the US Department of Energy(DOE).
文摘The use of neutron methods in environmental and biological sciences is rapidly emerging and accelerating with the development of new instruments at neutron user facilities.This article,based on a workshop held at Oak Ridge National Laboratory(ORNL),offers insights into the application of neutron techniques in environmental and biological sciences.We highlight recent advances and identify key challenges and potential future research areas.These include soil and rhizosphere processes,root water dynamics,plant-microbe interactions,structure and dynamics of biological systems,applications in synthetic biology and enzyme engineering,next-generation bioproducts,biomaterials and bioenergy,nanoscale structure,and fluid dynamics of porous materials in geochemistry.We provide an outlook on emerging opportunities with an emphasis on new capabilities that will be enabled at the Spallation Neutron Source Second Target Station currently under design at ORNL.The mission of scientific neutron user facilities worldwide is to enable science using state-of-the-art neutron capabilities.We aim to encourage researchers in the environmental and biological research community to explore the unique capability afforded by neutrons at these facilities.