In most coherent imaging modality,speckle noise is a major cause that blurs the boundary of tissues and degrades the image contrast.By utilizing the unique properties of supercontinuum(SC)generated by noise-like pulse...In most coherent imaging modality,speckle noise is a major cause that blurs the boundary of tissues and degrades the image contrast.By utilizing the unique properties of supercontinuum(SC)generated by noise-like pulses(NLPs)and a simple multi-frame averaging technique,we achieved significant speckle reduction in spectral domain optical coherence tomography(SD-OCT).We quantitatively compared the speckle of our proposed method with those of conventional swept source OCT(SS-OCT)and SD-OCT based on commercial light sources.The experimental results show that SC pumped by NLPs combined with noncoherent averaging method achieves better denoising performance in terms of contrast to noise ratio(CNR).展开更多
We report a high-average-power noise-like pulse(NLP) and dissipative soliton(DS) pulse fiber laser. Average power as high as 4.8 W could be obtained at the fundamental mode-locked repetition rate. The NLP can also be ...We report a high-average-power noise-like pulse(NLP) and dissipative soliton(DS) pulse fiber laser. Average power as high as 4.8 W could be obtained at the fundamental mode-locked repetition rate. The NLP can also be transformed into a more powerful DS mode-locking state by optimizing the polarization and losses of intra-cavity pulses in the nonlinear polarization evolution regime. The operation mode between the NLP and DS can be switched, and the laser output performance in both modes has been studied. The main advantage of this work is switchable high-power operation between the NLP and DS. In comparison with conventional single-mode NLP fiber lasers, the multi-function high-power optical source will greatly push its application in supercontinuum generation, coherence tomography, and industrial processing.展开更多
A mode-locked thulium-doped fiber laser(TDFL) based on nonlinear polarization rotation(NPR) with different net anomalous dispersion is demonstrated. When the cavity dispersion is-1.425 ps^2, the noise-like(NL) pulse w...A mode-locked thulium-doped fiber laser(TDFL) based on nonlinear polarization rotation(NPR) with different net anomalous dispersion is demonstrated. When the cavity dispersion is-1.425 ps^2, the noise-like(NL) pulse with coherence spike width of 406 fs and pulse energy of 12.342 nJ is generated at a center wavelength of 2003.2 nm with 3 dB spectral bandwidth of 23.20 nm. In the experimental period of 400 min, the 3 dB spectral bandwidth variation, the output power fluctuation, and the central wavelength shift are less than 0.06 nm, 0.04 d B, and0.4 nm, respectively, indicating that the NPR-based TDFL operating in the NL regime holds good long-term stability.展开更多
A stable noise-like(NL)mode-locked Tm-doped fiber laser(TDFL)relying on a nonlinear optical loop mirror(NOLM)was experimentally presented.Different from the previous NL mode-locked TDFL with NOLM,the entire polarizati...A stable noise-like(NL)mode-locked Tm-doped fiber laser(TDFL)relying on a nonlinear optical loop mirror(NOLM)was experimentally presented.Different from the previous NL mode-locked TDFL with NOLM,the entire polarization-maintaining(PM)fiber construction was utilized in our laser cavity,which makes the oscillator have a better resistance to environmental perturbations.The robust TDFL can deliver stable bound-state NL pulses with a pulse envelope tunable from〜14.1 ns to〜23.6 ns and maximum pulse energy of〜40.3 nj at a repetition rate of〜980.6 kHz.Meanwhile,the all-PM fiber laser shows good power stability[less than〜0.7%)and repeatability.展开更多
Noise-like pulses having a pedestal of 690 fs and a spike of 59.6 fs were generated in a nonlinear Yb-doped fiber amplification system. The seed source is a mode-locked Yb-doped fiber laser by nonlinear polarization r...Noise-like pulses having a pedestal of 690 fs and a spike of 59.6 fs were generated in a nonlinear Yb-doped fiber amplification system. The seed source is a mode-locked Yb-doped fiber laser by nonlinear polarization rotation,and dissipative soliton pulses were obtained in it. Then, the dissipative soliton pulses passed through a 7.6 m dispersive fiber to enhance the dispersion and nonlinearity. Further on, the dissipative soliton pulses were launched into a Yb-doped fiber nonlinear amplifier, and stable noise-like pulses with a pedestal of 6.26 ps and a spike of 227 fs were achieved. Finally, by a grating pair, the pedestal and spike of the noise-like pulses were effectively compressed to 690 fs and 59.6 fs, respectively. To the best of our knowledge, this is the shortest pedestal demonstrated in noise-like pulses operating at 1 μm.展开更多
Generation of noise-like rectangular pulse was investigated systematically in an Er–Yb co-doped fiber laser based on an intra-cavity coupler with different coupling ratios.When the coupling ratio was 5/95,stable mode...Generation of noise-like rectangular pulse was investigated systematically in an Er–Yb co-doped fiber laser based on an intra-cavity coupler with different coupling ratios.When the coupling ratio was 5/95,stable mode-locked pulses could be obtained with the pulse packet duration tunable from 4.86 ns to 80 ns.The repetition frequency was 1.186 MHz with the output spectrum centered at 1.6μm.The average output power and single pulse energy reached a record 1.43 W and1.21μJ,respectively.Pulse characteristics under different coupling ratios(5/95,10/90,20/80,30/70,40/60)were also presented and discussed.展开更多
We built a Tm:Ho co-doped fiber laser using a Ti3C2 MXene material as a saturable absorber(SA).The formation of vector solitons(VSs)and noise-like pulses(NLPs)was observed.The SA was prepared by dripping a Ti3C2 solut...We built a Tm:Ho co-doped fiber laser using a Ti3C2 MXene material as a saturable absorber(SA).The formation of vector solitons(VSs)and noise-like pulses(NLPs)was observed.The SA was prepared by dripping a Ti3C2 solution on a side-polished D-shaped fiber and then naturally vaporized.The VS is characterized by two coexisting sets of Kelly sidebands.By modulating the polarization controller in the fiber laser,NLPs with about 3.3 nm bandwidth can be switched from the VS.To the best of our knowledge,this is the first time that VSs have been generated in a fiber laser using a Ti3C2 MXene material as the SA.展开更多
Nyquist pulses have wide applications in many areas,from electronics to optics.Mode-locked lasers are ideal platforms to generate such pulses.However,how to generate high-quality Nyquist pulses in mode-locked lasers r...Nyquist pulses have wide applications in many areas,from electronics to optics.Mode-locked lasers are ideal platforms to generate such pulses.However,how to generate high-quality Nyquist pulses in mode-locked lasers remains elusive.We address this problem by managing different physical effects in mode-locked fiber lasers through extensive numerical simulations.We find that net dispersion,linear loss,gain and filter shaping can affect the quality of Nyquist pulses significantly.We also demonstrate that Nyquist pulses experience similariton shaping due to the nonlinear attractor effect in the gain medium.Our work may contribute to the design of Nyquist pulse sources and enrich the understanding of pulse shaping dynamics in mode-locked lasers.展开更多
Relativistic femtosecond mid-infrared pulses can be generated efficiently by laser interaction with near-criticaldensity plasmas.It is found theoretically and numerically that the radiation pressure of a circularly po...Relativistic femtosecond mid-infrared pulses can be generated efficiently by laser interaction with near-criticaldensity plasmas.It is found theoretically and numerically that the radiation pressure of a circularly polarized laser pulse first compresses the plasma electrons to form a dense flying mirror with a relativistic high speed.The pulse reflected by the mirror is red-shifted to the mid-infrared range.Full three-dimensional simulations demonstrate that the central wavelength of the mid-infrared pulse is tunable from 3µm to 14µm,and the laser energy conversion efficiency can reach as high as 13%.With a 0.5–10 PW incident laser pulse,the generated mid-infrared pulse reaches a peak power of 10–180 TW,which is interesting for various applications in ultrafast and high-field sciences.展开更多
A high-power laser ablating solid targets induces giant electromagnetic pulses(EMPs),which are intimately pertinent to laser parameters,such as energy and pulse width.In this study,we reveal the features of EMPs gener...A high-power laser ablating solid targets induces giant electromagnetic pulses(EMPs),which are intimately pertinent to laser parameters,such as energy and pulse width.In this study,we reveal the features of EMPs generated from a picosecond(ps)laser irradiating solid targets at the SG-Ⅱpicosecond petawatt(PSPW)laser facility.The laser energy and pulse,as well as target material and thickness,show determinative effects on the EMPs’amplitude.More intense EMPs are detected behind targets compared to those at the other three positions,and the EMP amplitude decreases from 90.09 kV/m to 17.8 kV/m with the gold target thickness increasing from 10μm to 20μm,which is suppressed when the laser pulse width is enlarged.The results are expected to provide more insight into EMPs produced by ps lasers coupling with targets and lay the foundation for an effective EMP shielding design in high-power laser infrastructures.展开更多
Pulse rate is one of the important characteristics of traditional Chinese medicine pulse diagnosis,and it is of great significance for determining the nature of cold and heat in diseases.The prediction of pulse rate b...Pulse rate is one of the important characteristics of traditional Chinese medicine pulse diagnosis,and it is of great significance for determining the nature of cold and heat in diseases.The prediction of pulse rate based on facial video is an exciting research field for getting palpation information by observation diagnosis.However,most studies focus on optimizing the algorithm based on a small sample of participants without systematically investigating multiple influencing factors.A total of 209 participants and 2,435 facial videos,based on our self-constructed Multi-Scene Sign Dataset and the public datasets,were used to perform a multi-level and multi-factor comprehensive comparison.The effects of different datasets,blood volume pulse signal extraction algorithms,region of interests,time windows,color spaces,pulse rate calculation methods,and video recording scenes were analyzed.Furthermore,we proposed a blood volume pulse signal quality optimization strategy based on the inverse Fourier transform and an improvement strategy for pulse rate estimation based on signal-to-noise ratio threshold sliding.We found that the effects of video estimation of pulse rate in the Multi-Scene Sign Dataset and Pulse Rate Detection Dataset were better than in other datasets.Compared with Fast independent component analysis and Single Channel algorithms,chrominance-based method and plane-orthogonal-to-skin algorithms have a more vital anti-interference ability and higher robustness.The performances of the five-organs fusion area and the full-face area were better than that of single sub-regions,and the fewer motion artifacts and better lighting can improve the precision of pulse rate estimation.展开更多
In this study,a pulsed,high voltage driven hollow-cathode electron beam sources through an optical trigger is designed with characteristics of simple structure,low cost,and easy triggering.To validate the new design,t...In this study,a pulsed,high voltage driven hollow-cathode electron beam sources through an optical trigger is designed with characteristics of simple structure,low cost,and easy triggering.To validate the new design,the characteristics of hollow-cathode discharge and electron beam characterization under pulsed high voltage drive are studied experimentally and discussed by discharge characteristics and analyses of waveform details,respectively.The validation experiments indicate that the pulsed high voltage supply significantly improves the frequency and stability of the discharge,which provides a new solution for the realization of a high-frequency,high-energy electron beam source.The peak current amplitude in the high-energy electron beam increases from 6.2 A to 79.6 A,which indicates the pulsed power mode significantly improves the electron beam performance.Besides,increasing the capacitance significantly affects the highcurrent,lower-energy electron beam more than the high-energy electron beam.展开更多
Giant electromagnetic pulses(EMPs) induced by high-power laser irradiating solid targets interfere with various experimental diagnoses and even damage equipment,so unveiling the evolution of EMPs inside the laser cham...Giant electromagnetic pulses(EMPs) induced by high-power laser irradiating solid targets interfere with various experimental diagnoses and even damage equipment,so unveiling the evolution of EMPs inside the laser chamber is crucial for designing effective EMP shielding.In this work,the transmission characteristics of EMPs as a function of distances from the target chamber center(TCC) are studied using B-dot probes.The mean EMP amplitude generated by picosecond laser-target interaction reaches 561 kV m^(-1),357 kV m^(-1),395 kV m^(-1),and 341 kV m^(-1)at 0.32 m,0.53 m,0.76 m,and 1 m from TCC,which decreases dramatically from 0.32 m to 0.53 m.However,it shows a fluctuation from 0.53 m to 1 m.The temporal features of EMPs indicate that time-domain EMP signals near the target chamber wall have a wider full width at half maximum compared to that close to TCC,mainly due to the echo oscillation of electromagnetic waves inside the target chamber based on simulation and experimentation.The conclusions of this study will provide a new approach to mitigate strong electromagnetic pulses by decreasing the echo oscillation of electromagnetic waves inside the target chamber during laser coupling with targets.展开更多
Molecular-frame photoelectron momentum distributions(MF-PMDs) of an H_(2)^(+) molecule ion in the presence of a pair of counter-rotating circularly polarized attosecond extreme ultraviolet laser pulses is studied by n...Molecular-frame photoelectron momentum distributions(MF-PMDs) of an H_(2)^(+) molecule ion in the presence of a pair of counter-rotating circularly polarized attosecond extreme ultraviolet laser pulses is studied by numerically solving the two-dimensional time-dependent Schrodinger equation within the frozen-nuclei approximation. At small time delay, our simulations show that the electron vortex structure is sensitive to the time delay and relative phase between the counterrotating pulses when they are partially overlapped. By adjusting time delay and relative phase, we have the ability to manipulate the MF-PMDs and the appearance of spiral arms. We further show that the internuclear distance can affect the spiral vortices due to its different transition cross sections in the parallel and perpendicular geometries. The lowest-order perturbation theory is employed to interpret these phenomena qualitatively. It is concluded that the internuclear distancedependent transition cross sections and the confinement effect in diatomic molecules are responsible for the variation of vortex structures in the MF-PMDs.展开更多
In seismology and earthquake engineering,it is fundamental to identify and characterize the pulse-like features in pulse-type ground motions.To capture the pulses that dominate structural responses,this study establis...In seismology and earthquake engineering,it is fundamental to identify and characterize the pulse-like features in pulse-type ground motions.To capture the pulses that dominate structural responses,this study establishes congruence and shift relationships between response spectrum surfaces.A similarity search between spectrum surfaces,supplemented with a similarity search in time series,has been applied to characterize the pulse-like features in pulse-type ground motions.The identified pulses are tested in predicting the rocking consequences of slender rectangular blocks under the original ground motions.Generally,the prediction is promising for the majority of the ground motions where the dominant pulse is correctly identified.展开更多
Background and Aims: Pulse pressure variation (PPV) is a reliable and predictive dynamic parameter presently being utilized for fluid responsiveness. In the operating room, fluid administration based on PPV monitoring...Background and Aims: Pulse pressure variation (PPV) is a reliable and predictive dynamic parameter presently being utilized for fluid responsiveness. In the operating room, fluid administration based on PPV monitoring helps the physician in deciding whether to volume resuscitate or use interventions in patients undergoing surgery. Propofol is an intravenous induction agent which lowers blood pressure. There are multiple causes such as depression in cardiac output, and peripheral vasodilatation for hypotension. We undertook this study to observe the utility of PPV as a guide to fluid therapy after propofol induction. Primary outcome of our study was to monitor PPV as a marker of fluid responsiveness for the hypotension caused by propofol induction. Secondary outcome included the correlation of PPV with other hemodynamic parameters like heart rate (HR), systolic blood pressure (SBP), and diastolic blood pressure (DBP);after induction with propofol at regular interval of time. Methods: A total number of 90 patients were recruited. Either of the radial artery was then cannulated under local anaesthesia with 20G VygonLeadercath arterial cannula and invasive monitoring transduced. A baseline recording of heart rate (HR), systolic blood pressure (SBP), diastolic blood pressure (DBP) and PPV was then recorded. Patients were then induced with predetermined doses of propofol (2 mg/kg) and recordings of HR, SBP, DBP, and PPV were taken at 5, 10 and 15 minutes. Results: Intraoperatively, PPV was significantly higher at 5 minutes and significantly lower at 15 minutes after induction. It was observed that there were no statistically significant correlations between PPV and SBP or DBP. PPV was strongly and directly associated with HR. Conclusion: We were able to establish that PPV predicts fluid responsiveness in hypotension caused by propofol induction;and can be used to administer fluid therapy in managing such hypotension. However, PPV was not directly correlated with hypotension subsequent to propofol administration.展开更多
We present a new global model of collinear autocorrelation based on second harmonic generation nonlinearity.The model is rigorously derived from the nonlinear coupled wave equation specific to the autocorrelation meas...We present a new global model of collinear autocorrelation based on second harmonic generation nonlinearity.The model is rigorously derived from the nonlinear coupled wave equation specific to the autocorrelation measurement configuration,without requiring a specific form of the incident pulse function.A rigorous solution of the nonlinear coupled wave equation is obtained in the time domain and expressed in a general analytical form.The global model fully accounts for the nonlinear interaction and propagation effects within nonlinear crystals,which are not captured by the classical local model.To assess the performance of the global model compared to the classic local model,we investigate the autocorrelation signals obtained from both models for different incident pulse waveforms and different full-widthes at half-maximum(FWHMs).When the incident pulse waveform is Lorentzian with an FWHM of 200 fs,the global model predicts an autocorrelation signal FWHM of 399.9 fs,while the classic local model predicts an FWHM of 331.4 fs.The difference between the two models is 68.6 fs,corresponding to an error of 17.2%.Similarly,for a sech-type incident pulse with an FWHM of 200 fs,the global model predicts an autocorrelation signal FWHM of 343.9 fs,while the local model predicts an FWHM of 308.8 fs.The difference between the two models is 35.1 fs,with an error of 10.2%.We further examine the behavior of the models for Lorentzian pulses with FWHMs of 100 fs,200 fs and 500 fs.The differences between the global and local models are 17.1 fs,68.6 fs and 86.0 fs,respectively,with errors approximately around 17%.These comparative analyses clearly demonstrate the superior accuracy of the global model in intensity autocorrelation modeling.展开更多
Photocurrent-voltage characterization is a crucial method for assessing key parameters in x-ray or y-ray semiconductor detectors,especially the carrier mobility lifetime product.However,the high biases during photocur...Photocurrent-voltage characterization is a crucial method for assessing key parameters in x-ray or y-ray semiconductor detectors,especially the carrier mobility lifetime product.However,the high biases during photocurrent measurements tend to cause severe ion migration,which can lead to the instability and inaccuracy of the test results.Given the mixed electronic-ionic charac teristics,it is imperative to devise novel methods capable of precisely measuring photocurrentvoltage characteristics under high bias conditions,free from interference caused by ion migration.In this paper,pulsed bias is employed to explore the photocurrent-voltage characteristics of MAPbBr_(3) single crystals.The method yields stable photocurrent-voltage characteristics at a pulsed bias of up to 30 V,proving to be effective in mitigating ion migration.Through fitting the modified Hecht equation,we determined the mobility lifetime products of 1.0×10^(2) cm^(2)·V^(-1)for hole and 2.78×10~(-3)cm^(2)·V^(-1)for electron.This approach offers a promising solution for accurately measuring the transport properties of carriers in perovskite.展开更多
We investigate the polarization properties of harmonics from the cyclic H_(3)^(2+) molecular ions in tailored bichromatic counter-rotating circularly polarized(BCCP)fields by solving the time-dependent Schrödinge...We investigate the polarization properties of harmonics from the cyclic H_(3)^(2+) molecular ions in tailored bichromatic counter-rotating circularly polarized(BCCP)fields by solving the time-dependent Schrödinger equation.The allowed harmonics and their helicities are associated with the symmetry compatibility of the field-target systems,and large intensity difference between adjacent harmonics with opposite helicities appears in a wide spectral range when the BCCP field is at certain rotation angles.We try to explain the intensity difference by using a recombination model based on the quantum-orbit theory and by analyzing the ionization pathways.Moreover,to synthesize attosecond pulse trains with tunable polarization,the intensity difference is manipulated by introducing a seed XUV field,and by changing the relative amplitude ratio as well as the helicity of BCCP fields.展开更多
基金This research was supported by the National Natural Science Foundation of China(61227807,61575108 and 61505034)Tsinghua Initiative Scientific Research Program(2013THZ02-3)C.L.Pan and Y.J.You were supported in part by the Ministry of Science and Technology,Taiwan,under Grant 103-2622-E-007-006-CC2 and by the National Tsing Hua University Research Program Grant 104N2711E1.C.L.Pan is also supported by the Air Force Office of Scientific Research FA2386-13-1-4086.The first three authors contribute equally to this paper。
文摘In most coherent imaging modality,speckle noise is a major cause that blurs the boundary of tissues and degrades the image contrast.By utilizing the unique properties of supercontinuum(SC)generated by noise-like pulses(NLPs)and a simple multi-frame averaging technique,we achieved significant speckle reduction in spectral domain optical coherence tomography(SD-OCT).We quantitatively compared the speckle of our proposed method with those of conventional swept source OCT(SS-OCT)and SD-OCT based on commercial light sources.The experimental results show that SC pumped by NLPs combined with noncoherent averaging method achieves better denoising performance in terms of contrast to noise ratio(CNR).
基金supported by the National Natural Science Foundation of China (Grant No. 12164030)the Major Program of the National Natural Science Foundation of China (Grant No. 12034020)+1 种基金Young Science and Technology Talents of Inner Mongolia, China (Grant No. NJYT22101)the Talent Development Fund of Inner Mongolia, China。
文摘We report a high-average-power noise-like pulse(NLP) and dissipative soliton(DS) pulse fiber laser. Average power as high as 4.8 W could be obtained at the fundamental mode-locked repetition rate. The NLP can also be transformed into a more powerful DS mode-locking state by optimizing the polarization and losses of intra-cavity pulses in the nonlinear polarization evolution regime. The operation mode between the NLP and DS can be switched, and the laser output performance in both modes has been studied. The main advantage of this work is switchable high-power operation between the NLP and DS. In comparison with conventional single-mode NLP fiber lasers, the multi-function high-power optical source will greatly push its application in supercontinuum generation, coherence tomography, and industrial processing.
基金Fundamental Research Funds for the Central Universities(2016YJS034)
文摘A mode-locked thulium-doped fiber laser(TDFL) based on nonlinear polarization rotation(NPR) with different net anomalous dispersion is demonstrated. When the cavity dispersion is-1.425 ps^2, the noise-like(NL) pulse with coherence spike width of 406 fs and pulse energy of 12.342 nJ is generated at a center wavelength of 2003.2 nm with 3 dB spectral bandwidth of 23.20 nm. In the experimental period of 400 min, the 3 dB spectral bandwidth variation, the output power fluctuation, and the central wavelength shift are less than 0.06 nm, 0.04 d B, and0.4 nm, respectively, indicating that the NPR-based TDFL operating in the NL regime holds good long-term stability.
基金supported by the National Natural Science Foundation of China (NSFC) (No. 61905146)the China Postdoctoral Science Foundation (No. 2020M682864)the Shenzhen Key Project for Technology Development (Nos. JSGG20190819175801678 and JSGG20191129105838333)
文摘A stable noise-like(NL)mode-locked Tm-doped fiber laser(TDFL)relying on a nonlinear optical loop mirror(NOLM)was experimentally presented.Different from the previous NL mode-locked TDFL with NOLM,the entire polarization-maintaining(PM)fiber construction was utilized in our laser cavity,which makes the oscillator have a better resistance to environmental perturbations.The robust TDFL can deliver stable bound-state NL pulses with a pulse envelope tunable from〜14.1 ns to〜23.6 ns and maximum pulse energy of〜40.3 nj at a repetition rate of〜980.6 kHz.Meanwhile,the all-PM fiber laser shows good power stability[less than〜0.7%)and repeatability.
基金the Beijing Natural Science Foundation(No.4192015)the National Natural Science Foundation of China(No.61975003).
文摘Noise-like pulses having a pedestal of 690 fs and a spike of 59.6 fs were generated in a nonlinear Yb-doped fiber amplification system. The seed source is a mode-locked Yb-doped fiber laser by nonlinear polarization rotation,and dissipative soliton pulses were obtained in it. Then, the dissipative soliton pulses passed through a 7.6 m dispersive fiber to enhance the dispersion and nonlinearity. Further on, the dissipative soliton pulses were launched into a Yb-doped fiber nonlinear amplifier, and stable noise-like pulses with a pedestal of 6.26 ps and a spike of 227 fs were achieved. Finally, by a grating pair, the pedestal and spike of the noise-like pulses were effectively compressed to 690 fs and 59.6 fs, respectively. To the best of our knowledge, this is the shortest pedestal demonstrated in noise-like pulses operating at 1 μm.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.61435009,61235008,and 61405254)
文摘Generation of noise-like rectangular pulse was investigated systematically in an Er–Yb co-doped fiber laser based on an intra-cavity coupler with different coupling ratios.When the coupling ratio was 5/95,stable mode-locked pulses could be obtained with the pulse packet duration tunable from 4.86 ns to 80 ns.The repetition frequency was 1.186 MHz with the output spectrum centered at 1.6μm.The average output power and single pulse energy reached a record 1.43 W and1.21μJ,respectively.Pulse characteristics under different coupling ratios(5/95,10/90,20/80,30/70,40/60)were also presented and discussed.
基金Project supported by the National Natural Science Foundation of China(Nos.11674133 and 61575089)the Postgraduate Research Innovation Program of Jiangsu Normal University,China(No.2018YXJ594)。
文摘We built a Tm:Ho co-doped fiber laser using a Ti3C2 MXene material as a saturable absorber(SA).The formation of vector solitons(VSs)and noise-like pulses(NLPs)was observed.The SA was prepared by dripping a Ti3C2 solution on a side-polished D-shaped fiber and then naturally vaporized.The VS is characterized by two coexisting sets of Kelly sidebands.By modulating the polarization controller in the fiber laser,NLPs with about 3.3 nm bandwidth can be switched from the VS.To the best of our knowledge,this is the first time that VSs have been generated in a fiber laser using a Ti3C2 MXene material as the SA.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.11621404,11561121003,11727812,61775059,12074122,62022033,and 11704123)Shanghai Rising-Star Program,the Sustainedly Supported Foundation by the National Key Laboratory of Science and Technology on Space Microwave(Grant No.HTKT2022KL504008)+1 种基金Shanghai Natural Science Foundation(Grant No.23ZR1419000)the National Key Laboratory Foundation of China(Grant No.6142411196307).
文摘Nyquist pulses have wide applications in many areas,from electronics to optics.Mode-locked lasers are ideal platforms to generate such pulses.However,how to generate high-quality Nyquist pulses in mode-locked lasers remains elusive.We address this problem by managing different physical effects in mode-locked fiber lasers through extensive numerical simulations.We find that net dispersion,linear loss,gain and filter shaping can affect the quality of Nyquist pulses significantly.We also demonstrate that Nyquist pulses experience similariton shaping due to the nonlinear attractor effect in the gain medium.Our work may contribute to the design of Nyquist pulse sources and enrich the understanding of pulse shaping dynamics in mode-locked lasers.
基金supported by the National Natural Science Foundation of China(Grant Nos.12375244,12135009,and 12275356)the Hunan Provincial Innovation Foun-dation for Postgraduate(Grant Nos.CX20210062 and CX20230006).
文摘Relativistic femtosecond mid-infrared pulses can be generated efficiently by laser interaction with near-criticaldensity plasmas.It is found theoretically and numerically that the radiation pressure of a circularly polarized laser pulse first compresses the plasma electrons to form a dense flying mirror with a relativistic high speed.The pulse reflected by the mirror is red-shifted to the mid-infrared range.Full three-dimensional simulations demonstrate that the central wavelength of the mid-infrared pulse is tunable from 3µm to 14µm,and the laser energy conversion efficiency can reach as high as 13%.With a 0.5–10 PW incident laser pulse,the generated mid-infrared pulse reaches a peak power of 10–180 TW,which is interesting for various applications in ultrafast and high-field sciences.
基金Project supported by the Strategic Priority Research Program of the Chinese Academy of Sciences(Grant No.XDA25020205)the program of Science and Technology on Plasma Physics Laboratory,China Academy of Engineering Physics(Grant No.6142A04220108)。
文摘A high-power laser ablating solid targets induces giant electromagnetic pulses(EMPs),which are intimately pertinent to laser parameters,such as energy and pulse width.In this study,we reveal the features of EMPs generated from a picosecond(ps)laser irradiating solid targets at the SG-Ⅱpicosecond petawatt(PSPW)laser facility.The laser energy and pulse,as well as target material and thickness,show determinative effects on the EMPs’amplitude.More intense EMPs are detected behind targets compared to those at the other three positions,and the EMP amplitude decreases from 90.09 kV/m to 17.8 kV/m with the gold target thickness increasing from 10μm to 20μm,which is suppressed when the laser pulse width is enlarged.The results are expected to provide more insight into EMPs produced by ps lasers coupling with targets and lay the foundation for an effective EMP shielding design in high-power laser infrastructures.
基金supported by the Key Research Program of the Chinese Academy of Sciences(grant number ZDRW-ZS-2021-1-2).
文摘Pulse rate is one of the important characteristics of traditional Chinese medicine pulse diagnosis,and it is of great significance for determining the nature of cold and heat in diseases.The prediction of pulse rate based on facial video is an exciting research field for getting palpation information by observation diagnosis.However,most studies focus on optimizing the algorithm based on a small sample of participants without systematically investigating multiple influencing factors.A total of 209 participants and 2,435 facial videos,based on our self-constructed Multi-Scene Sign Dataset and the public datasets,were used to perform a multi-level and multi-factor comprehensive comparison.The effects of different datasets,blood volume pulse signal extraction algorithms,region of interests,time windows,color spaces,pulse rate calculation methods,and video recording scenes were analyzed.Furthermore,we proposed a blood volume pulse signal quality optimization strategy based on the inverse Fourier transform and an improvement strategy for pulse rate estimation based on signal-to-noise ratio threshold sliding.We found that the effects of video estimation of pulse rate in the Multi-Scene Sign Dataset and Pulse Rate Detection Dataset were better than in other datasets.Compared with Fast independent component analysis and Single Channel algorithms,chrominance-based method and plane-orthogonal-to-skin algorithms have a more vital anti-interference ability and higher robustness.The performances of the five-organs fusion area and the full-face area were better than that of single sub-regions,and the fewer motion artifacts and better lighting can improve the precision of pulse rate estimation.
基金supported by National Natural Science Foundation of China(No.12102099)the National Key R&D Program of China(No.2021YFC2202700)the Outstanding Academic Leader Project of Shanghai(Youth)(No.23XD1421700),respectively。
文摘In this study,a pulsed,high voltage driven hollow-cathode electron beam sources through an optical trigger is designed with characteristics of simple structure,low cost,and easy triggering.To validate the new design,the characteristics of hollow-cathode discharge and electron beam characterization under pulsed high voltage drive are studied experimentally and discussed by discharge characteristics and analyses of waveform details,respectively.The validation experiments indicate that the pulsed high voltage supply significantly improves the frequency and stability of the discharge,which provides a new solution for the realization of a high-frequency,high-energy electron beam source.The peak current amplitude in the high-energy electron beam increases from 6.2 A to 79.6 A,which indicates the pulsed power mode significantly improves the electron beam performance.Besides,increasing the capacitance significantly affects the highcurrent,lower-energy electron beam more than the high-energy electron beam.
基金supported by National Grand Instrument Project (No.2019YFF01014404)the National Key Program for S & T Research and Development (No. 2022YFA1603202)+1 种基金National Natural Science Foundation of China (Nos.U2241281 and 11975037)the Foundation of Science and Technology on Plasma Physics Laboratory (No.6142A04220108)。
文摘Giant electromagnetic pulses(EMPs) induced by high-power laser irradiating solid targets interfere with various experimental diagnoses and even damage equipment,so unveiling the evolution of EMPs inside the laser chamber is crucial for designing effective EMP shielding.In this work,the transmission characteristics of EMPs as a function of distances from the target chamber center(TCC) are studied using B-dot probes.The mean EMP amplitude generated by picosecond laser-target interaction reaches 561 kV m^(-1),357 kV m^(-1),395 kV m^(-1),and 341 kV m^(-1)at 0.32 m,0.53 m,0.76 m,and 1 m from TCC,which decreases dramatically from 0.32 m to 0.53 m.However,it shows a fluctuation from 0.53 m to 1 m.The temporal features of EMPs indicate that time-domain EMP signals near the target chamber wall have a wider full width at half maximum compared to that close to TCC,mainly due to the echo oscillation of electromagnetic waves inside the target chamber based on simulation and experimentation.The conclusions of this study will provide a new approach to mitigate strong electromagnetic pulses by decreasing the echo oscillation of electromagnetic waves inside the target chamber during laser coupling with targets.
基金Project supported by the Natural Science Foundation of Jilin Province,China (Grant No.20220101016JC)the National Key Research and Development Program of China (Grant No.2022YFE0134200)+1 种基金the National Natural Science Foundation of China (Grant Nos.12174147,91850114,and 11774131)the Open Research Fund of State Key Laboratory of Transient Optics and Photonics。
文摘Molecular-frame photoelectron momentum distributions(MF-PMDs) of an H_(2)^(+) molecule ion in the presence of a pair of counter-rotating circularly polarized attosecond extreme ultraviolet laser pulses is studied by numerically solving the two-dimensional time-dependent Schrodinger equation within the frozen-nuclei approximation. At small time delay, our simulations show that the electron vortex structure is sensitive to the time delay and relative phase between the counterrotating pulses when they are partially overlapped. By adjusting time delay and relative phase, we have the ability to manipulate the MF-PMDs and the appearance of spiral arms. We further show that the internuclear distance can affect the spiral vortices due to its different transition cross sections in the parallel and perpendicular geometries. The lowest-order perturbation theory is employed to interpret these phenomena qualitatively. It is concluded that the internuclear distancedependent transition cross sections and the confinement effect in diatomic molecules are responsible for the variation of vortex structures in the MF-PMDs.
基金National Key Research and Development Program,Ministry of Science and Technology of China under Grant No.2022YFC3803004the National Natural Science Foundation of China under Grant No.51838004。
文摘In seismology and earthquake engineering,it is fundamental to identify and characterize the pulse-like features in pulse-type ground motions.To capture the pulses that dominate structural responses,this study establishes congruence and shift relationships between response spectrum surfaces.A similarity search between spectrum surfaces,supplemented with a similarity search in time series,has been applied to characterize the pulse-like features in pulse-type ground motions.The identified pulses are tested in predicting the rocking consequences of slender rectangular blocks under the original ground motions.Generally,the prediction is promising for the majority of the ground motions where the dominant pulse is correctly identified.
文摘Background and Aims: Pulse pressure variation (PPV) is a reliable and predictive dynamic parameter presently being utilized for fluid responsiveness. In the operating room, fluid administration based on PPV monitoring helps the physician in deciding whether to volume resuscitate or use interventions in patients undergoing surgery. Propofol is an intravenous induction agent which lowers blood pressure. There are multiple causes such as depression in cardiac output, and peripheral vasodilatation for hypotension. We undertook this study to observe the utility of PPV as a guide to fluid therapy after propofol induction. Primary outcome of our study was to monitor PPV as a marker of fluid responsiveness for the hypotension caused by propofol induction. Secondary outcome included the correlation of PPV with other hemodynamic parameters like heart rate (HR), systolic blood pressure (SBP), and diastolic blood pressure (DBP);after induction with propofol at regular interval of time. Methods: A total number of 90 patients were recruited. Either of the radial artery was then cannulated under local anaesthesia with 20G VygonLeadercath arterial cannula and invasive monitoring transduced. A baseline recording of heart rate (HR), systolic blood pressure (SBP), diastolic blood pressure (DBP) and PPV was then recorded. Patients were then induced with predetermined doses of propofol (2 mg/kg) and recordings of HR, SBP, DBP, and PPV were taken at 5, 10 and 15 minutes. Results: Intraoperatively, PPV was significantly higher at 5 minutes and significantly lower at 15 minutes after induction. It was observed that there were no statistically significant correlations between PPV and SBP or DBP. PPV was strongly and directly associated with HR. Conclusion: We were able to establish that PPV predicts fluid responsiveness in hypotension caused by propofol induction;and can be used to administer fluid therapy in managing such hypotension. However, PPV was not directly correlated with hypotension subsequent to propofol administration.
基金Project supported by the Science and Technology Project of Guangdong(Grant No.2020B010190001)the National Natural Science Foundation of China(Grant No.11974119)+1 种基金the Guangdong Innovative and Entrepreneurial Research Team Program(Grant No.2016ZT06C594)the National Key R&D Program of China(Grant No.2018YFA0306200)。
文摘We present a new global model of collinear autocorrelation based on second harmonic generation nonlinearity.The model is rigorously derived from the nonlinear coupled wave equation specific to the autocorrelation measurement configuration,without requiring a specific form of the incident pulse function.A rigorous solution of the nonlinear coupled wave equation is obtained in the time domain and expressed in a general analytical form.The global model fully accounts for the nonlinear interaction and propagation effects within nonlinear crystals,which are not captured by the classical local model.To assess the performance of the global model compared to the classic local model,we investigate the autocorrelation signals obtained from both models for different incident pulse waveforms and different full-widthes at half-maximum(FWHMs).When the incident pulse waveform is Lorentzian with an FWHM of 200 fs,the global model predicts an autocorrelation signal FWHM of 399.9 fs,while the classic local model predicts an FWHM of 331.4 fs.The difference between the two models is 68.6 fs,corresponding to an error of 17.2%.Similarly,for a sech-type incident pulse with an FWHM of 200 fs,the global model predicts an autocorrelation signal FWHM of 343.9 fs,while the local model predicts an FWHM of 308.8 fs.The difference between the two models is 35.1 fs,with an error of 10.2%.We further examine the behavior of the models for Lorentzian pulses with FWHMs of 100 fs,200 fs and 500 fs.The differences between the global and local models are 17.1 fs,68.6 fs and 86.0 fs,respectively,with errors approximately around 17%.These comparative analyses clearly demonstrate the superior accuracy of the global model in intensity autocorrelation modeling.
基金Project supported by the National Natural Science Foundation of China (Grant No.62104234)Shanghai Explorer Program (Grant No.22TS1400100)。
文摘Photocurrent-voltage characterization is a crucial method for assessing key parameters in x-ray or y-ray semiconductor detectors,especially the carrier mobility lifetime product.However,the high biases during photocurrent measurements tend to cause severe ion migration,which can lead to the instability and inaccuracy of the test results.Given the mixed electronic-ionic charac teristics,it is imperative to devise novel methods capable of precisely measuring photocurrentvoltage characteristics under high bias conditions,free from interference caused by ion migration.In this paper,pulsed bias is employed to explore the photocurrent-voltage characteristics of MAPbBr_(3) single crystals.The method yields stable photocurrent-voltage characteristics at a pulsed bias of up to 30 V,proving to be effective in mitigating ion migration.Through fitting the modified Hecht equation,we determined the mobility lifetime products of 1.0×10^(2) cm^(2)·V^(-1)for hole and 2.78×10~(-3)cm^(2)·V^(-1)for electron.This approach offers a promising solution for accurately measuring the transport properties of carriers in perovskite.
基金supported by the National Natural Science Foundation of China(Grant No.91950117)the Fundamental Research Funds for the Central Universities.
文摘We investigate the polarization properties of harmonics from the cyclic H_(3)^(2+) molecular ions in tailored bichromatic counter-rotating circularly polarized(BCCP)fields by solving the time-dependent Schrödinger equation.The allowed harmonics and their helicities are associated with the symmetry compatibility of the field-target systems,and large intensity difference between adjacent harmonics with opposite helicities appears in a wide spectral range when the BCCP field is at certain rotation angles.We try to explain the intensity difference by using a recombination model based on the quantum-orbit theory and by analyzing the ionization pathways.Moreover,to synthesize attosecond pulse trains with tunable polarization,the intensity difference is manipulated by introducing a seed XUV field,and by changing the relative amplitude ratio as well as the helicity of BCCP fields.