期刊文献+
共找到5,328篇文章
< 1 2 250 >
每页显示 20 50 100
Non-Contact System for Global Reporting Format (GRF) Automation: Contaminant Body Detection and Depth Estimation in the Case of Rainy Weather
1
作者 Dieudonné Sama Doua Allain Gnabahou +1 位作者 Brahima Bayili Oula Fayçal Denilson Ouattara 《Open Journal of Applied Sciences》 2023年第11期2127-2140,共14页
The paper designed a non-contact system in order to perform the application (on a runway) of the Global Reporting Format (GRF) developed by International Civil Aviation Organization (ICAO). The system involves devices... The paper designed a non-contact system in order to perform the application (on a runway) of the Global Reporting Format (GRF) developed by International Civil Aviation Organization (ICAO). The system involves devices that film the surface (a runway in our case) from the air and displays the contaminant (water) body and measures the depth of the water automatically during the inspection. While measuring, data are sent to a computer used as a receiver. The developed devices are automatic devices implemented specially to use during rainy weather or even for some other cases. The aerial system uses a raspberry pi 4 model B, a camera, a laser sensor, an ultrasonic module, a Virtual Network Computing (VNC) and python codes developed by the authors. Results obtained show that using these devices to retrieve the Runway Condition Report (RCR) is very fast and human presence on the runway is not needed. The results obtained using these devices show that the method used herein is a proper solution to the GRF issues in the rainy areas, where the contaminant body detection and the accurate depth measurement were not well estimated because of the lack of a suitable method. 展开更多
关键词 Global Reporting Format Runway Surface Condition Runway Contaminant non-contact System ICAO
下载PDF
Monitoring Contact State of Laboratory Fault with Coda Transmission Waves 被引量:1
2
作者 XIE Fan REN Yaqiong HOU Jinxin 《Earthquake Research in China》 CSCD 2019年第3期431-436,共6页
We monitored the amplitude changes of coda transmission waves around 500 kHz across the frictional interface of a simulated 1. 5-meter-long fault during normal stress holding test.We find that the amplitude of coda tr... We monitored the amplitude changes of coda transmission waves around 500 kHz across the frictional interface of a simulated 1. 5-meter-long fault during normal stress holding test.We find that the amplitude of coda transmission waves increases with the logarithm of stationary contact time. Localized increase amounted to a level ranging from 4% to 16%along the fault is observed during the 1-hour experiment. We discuss that the frictional strength at mesoscopic scale,which is related to the amplitude of coda transmission waves,is responsible for the phenomenon. Combining the reported method with other complementary approaches will enhance the understanding of fault mechanism either at laboratory or on-site applications. 展开更多
关键词 CODA transmission waves LABORATORY fault Frictional contact area
下载PDF
Static Radical Stiffness and Contact Behavior of Nonpneumatic Mechanical Elastic Wheel 被引量:1
3
作者 ZANG Liguo ZHAO Youqun +1 位作者 SUN Haiyan LIN Fen 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI CSCD 2019年第4期663-674,共12页
Conventional pneumatic tires exhibit disadvantages such as puncture,blowout at high speed,pressure maintenance,etc.Owing to these structural inevitable weaknesses,non?pneumatic tires have been developed and are invest... Conventional pneumatic tires exhibit disadvantages such as puncture,blowout at high speed,pressure maintenance,etc.Owing to these structural inevitable weaknesses,non?pneumatic tires have been developed and are investigated.A non?pneumatic mechanical elastic wheel(NPMEW)is introduced and investigated as a function of static radical stiffness characteristics and contact behavior.A bench test method is utilized to improve the riding comfort and the traction traffic ability of NPMEW based on tire characteristics test rig,and the static radical stiffness characteristics and the contact behavior of NPMEW are compared with that of an insert supporting run?flat tire(ISRFT).The vertical force?deformation curves and deformed shapes and contact areas of the NPMEW and ISRFT are obtained using a set of vertical loads.The contact behavior is evaluated using extracted geometrical and mechanical feature parameters of the two tires.The results indicate that the NPMEW appears to exhibit considerably high radical stiffness,and the numerical value is dependent on the mechanical characteristic of the flexible tire body and hinge units.NPMEW demonstrates more uniform contact pressure than ISRFT within a certain loading range,and it can efficiently mitigate the problem of stress concentration in ISRFT shoulder under heavy load and enhance the wear resistance and ground grip performances. 展开更多
关键词 vehicles non⁃pneumatic mechanical elastic wheel run⁃flat tire radical stiffness contact behavior
下载PDF
NON-CONTACT MEASUREMENT SYSTEM OF FREEFORM SURFACE AND NURBS RECONSTRUCTION OF MEASUREMENT POINTS 被引量:4
4
作者 Li Jian Wang Wen Chen Zichen Institute of Advanced Manufacturing Engineering, Zhejiang University, Hangzhou 310027, China 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2002年第4期366-371,共6页
Based on the development of the non-contact measurement system of free-formsurface, NURBS reconstruction of measurement points of freeform surface is effectively realized bymodifying the objective function and recursi... Based on the development of the non-contact measurement system of free-formsurface, NURBS reconstruction of measurement points of freeform surface is effectively realized bymodifying the objective function and recursive procedure and calculating the optimum number ofcontrol points. The reconstruction precision is evaluated through Ja-cobi's transformation method.The feasibility of the measurement system and effectiveness of the reconstruction algorithm aboveare proved by experiment. 展开更多
关键词 freeform surface non-contact measurement NURBS precision evaluation
下载PDF
Non-contact tensile viscoelastic characterization of microscale biological materials 被引量:3
5
作者 Yuhui Li Yuan Hong +7 位作者 Guang-Kui Xu Shaobao Liu Qiang Shi Deding Tang Hui Yang Guy M.Genin Tian Jian Lu Feng Xu 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 2018年第3期589-599,共11页
Many structures and materials in nature and physiology have important "meso-scale" structures at the micron lengthscale whose tensile responses have proven difficult to characterize mechanically. Although techniques... Many structures and materials in nature and physiology have important "meso-scale" structures at the micron lengthscale whose tensile responses have proven difficult to characterize mechanically. Although techniques such as atomic force microscopy and micro- and nano-identation are mature for compression and indentation testing at the nano-scale, and standard uniaxial and shear rheometry techniques exist for the macroscale, few techniques are applicable for tensile-testing at the micrometre-scale, leaving a gap in our understanding of hierarchical biomaterials. Here, we present a novel magnetic mechanical testing (MMT) system that enables viscoelastic tensile testing at this critical length scale. The MMT system applies non-contact loading, avoiding gripping and surface interaction effects. We demonstrate application of the MMT system to the first analyses of the pure tensile responses of several native and engineered tissue systems at the mesoscale, showing the broad potential of the system for exploring micro- and meso-scale analysis of structured and hierarchical biological systems. 展开更多
关键词 Mechanical testing Hierarchical biomaterials non-contact actuation Microscale analysis
下载PDF
Transient Fault Locating Method Based on Line Voltage and Zero-mode Current in Non-solidly Earthed Network 被引量:48
6
作者 ZHANG Linli XU Bingyin +1 位作者 XUE Yongduan GAO Houlei 《中国电机工程学报》 EI CSCD 北大核心 2012年第13期I0015-I0015,198,共1页
为解决配电网小电流接地故障时故障点定位困难的问题,提出一种基于线电压和零模电流暂态分量的故障定位新方法。该方法借助馈线自动化(feeder automation,FA)系统实现,不需要额外增加设备。馈线终端检测线电压和零模电流信号,利... 为解决配电网小电流接地故障时故障点定位困难的问题,提出一种基于线电压和零模电流暂态分量的故障定位新方法。该方法借助馈线自动化(feeder automation,FA)系统实现,不需要额外增加设备。馈线终端检测线电压和零模电流信号,利用暂态线电压的希尔伯特变换与暂态零模电流的乘积计算故障方向参数,FA主站根据故障点前后方向参数极性相反的特征确定故障点所在的线路区段。介绍基于线电压的小电流接地故障检测和接地故障相确定的算法。数字仿真与试验结果表明该方法是正确可行的。 展开更多
关键词 低压配电网络 瞬态故障 定位方法 接地电流 线电压 非直接接地系统 单相接地故障 馈线自动化
下载PDF
A METHOD FOR THE ANALYSIS OF DYNAMIC RESPONSE OF STRUCTURE CONTAINING NON-SMOOTH CONTACTABLE INTERFACES 被引量:3
7
作者 刘晶波 刘书 杜修力 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 1999年第1期63-72,共10页
A novel single-step method is proposed for the analysis of dynamic response of visco-elastic structures containing non-smooth contactable interfaces. In the method, a two-level algorithm is employed for dealing with a... A novel single-step method is proposed for the analysis of dynamic response of visco-elastic structures containing non-smooth contactable interfaces. In the method, a two-level algorithm is employed for dealing with a nonlinear boundary condition caused by the dynamic contact of interfaces. At the first level, an explicit method is adopted to calculate nodal displacements of global viscoelastic system without considering the effect of dynamic contact of interfaces and at the second level, by introducing contact conditions of interfaces, a group of equations of lower order is derived to calculate dynamic contact normal and shear forces on the interfaces. The method is convenient and efficient for the analysis of problems of dynamic contact. The accuracy of the method is of the second order and the numerical stability condition is wider than that of other explicit methods. 展开更多
关键词 non-smooth contactable interfaces visco-elastic structure dynamic response
下载PDF
Design of Non-contact On-load Automatic Regulating Voltage Transformer 被引量:5
8
作者 Zhao Qi 《Journal of Northeast Agricultural University(English Edition)》 CAS 2015年第3期91-96,共6页
At present, an automatic-mechanic contact tap-changer is widely used in power system, but it can not frequently operate. In addition, arc will occur when the switch changes. In order to solve these two problems, this ... At present, an automatic-mechanic contact tap-changer is widely used in power system, but it can not frequently operate. In addition, arc will occur when the switch changes. In order to solve these two problems, this paper presented an automatic on-load voltage-regulating distributing transformer which employed non-contact solid-state relay as tap-changer, and mainly introduced its structure, basic principal, design method of each key link and experimental results. Laboratory simulation experiments informed that the scheme was feasible. It was a smooth and effective experiment device, which was practical in application. 展开更多
关键词 solid-state relay on-load tap-changer non-contact distributing transformer design
下载PDF
Deep-Hole Inner Diameter Measuring System Based on Non-contact Capacitance Sensor 被引量:3
9
作者 于永新 张恒 +1 位作者 王宗超 常以哲 《Transactions of Tianjin University》 EI CAS 2010年第6期447-451,共5页
A precise aperture measuring system of small deep holes with capacitance sensors is presented. Based on the working principle of non-contact capacitance sensors, influence of the edge effect of gauge head is studied, ... A precise aperture measuring system of small deep holes with capacitance sensors is presented. Based on the working principle of non-contact capacitance sensors, influence of the edge effect of gauge head is studied, and one capacitance sensor for measuring the aperture of the small blind holes or through holes is introduced. The system is composed of one positioning device, one aperture measuring capacitance sensor, one measuring circuit, and software. This system employs visual CCD and two-dimensional micro-adjusting mechanism to realize the precise positioning. By LabView software this system is controlled to run automatically, to carry out calibration and automatic data collection, and to make data import into the database directly. Experiments proved that the diameter measurement range of the system can be 1.8 mm—7 mm, the resolution can be up to 5 nm—10 nm, the repeatability measurement standard deviation can be 0.05 μm—0.1 μm, and the measurement uncertainty can achieve 0.15 μm—0.3 μm. So the measuring system can realize the nanometer-level measurement. 展开更多
关键词 深洞的测量 非接触 电荷耦合器件 步进马达 精确的放
下载PDF
Iterative Learning Fault Diagnosis Algorithm for Non-uniform Sampling Hybrid System 被引量:2
10
作者 Hongfeng Tao Dapeng Chen Huizhong Yang 《IEEE/CAA Journal of Automatica Sinica》 SCIE EI CSCD 2017年第3期534-542,共9页
For a class of non-uniform output sampling hybrid system with actuator faults and bounded disturbances,an iterative learning fault diagnosis algorithm is proposed.Firstly,in order to measure the impact of fault on sys... For a class of non-uniform output sampling hybrid system with actuator faults and bounded disturbances,an iterative learning fault diagnosis algorithm is proposed.Firstly,in order to measure the impact of fault on system between every consecutive output sampling instants,the actual fault function is transformed to obtain an equivalent fault model by using the integral mean value theorem,then the non-uniform sampling hybrid system is converted to continuous systems with timevarying delay based on the output delay method.Afterwards,an observer-based fault diagnosis filter with virtual fault is designed to estimate the equivalent fault,and the iterative learning regulation algorithm is chosen to update the virtual fault repeatedly to make it approximate the actual equivalent fault after some iterative learning trials,so the algorithm can detect and estimate the system faults adaptively.Simulation results of an electro-mechanical control system model with different types of faults illustrate the feasibility and effectiveness of this algorithm. 展开更多
关键词 Equivalent fault model fault diagnosis iterative learning algorithm non-uniform sampling hybrid system virtual fault
下载PDF
An approach to a non-contact vital sign monitoring using dual-frequency microwave radars for elderly care 被引量:3
11
作者 Satoshi Suzuki Takemi Matsui +2 位作者 Masayuki Kagawa Takafumi Asao Kentaro Kotani 《Journal of Biomedical Science and Engineering》 2013年第7期704-711,共8页
This study aimed to produce a prototype system for non-contact vital sign monitoring of the elderly using microwave radar with the intention of reducing the burdens on monitored individuals and nursing caregivers. In ... This study aimed to produce a prototype system for non-contact vital sign monitoring of the elderly using microwave radar with the intention of reducing the burdens on monitored individuals and nursing caregivers. In addition, we tested the ability of the proposed prototype system to measure the respiratory and heart rates of the elderly in a nursing home and discussed the systems effectiveness and problems by examining results of real-time monitoring. The prototype system consisted of two 24-GHz microwave radar antennas and an analysis system. The antennas were positioned below a mattress to monitor motion on the body surface for measuring cardiac and respiratory rates from the dorsal side of the subjects (23.3 ± 1.2 years) who would be lying on the mattress. The heart rates determined by the prototype system correlated significantly with those measured by electrocardiography (r = 0.92). Similarly, the respiratory rates determined by the prototype correlated with those obtained from respiration curves (r = 0.94). Next, we investigated the effectiveness of the prototype system with 7 elderly patients (93.3 ± 10.56 years) at a nursing home. The proposed system appears to be a promising tool for monitoring the vital signs of the elderly in a way that alleviates the need to attach electrodes overnight to confirm patient safety. 展开更多
关键词 non-contact Sensing VITAL SIGNS Microwave Radar ELDERLY CARE
下载PDF
Particle swarm optimization based RVM classifier for non-linear circuit fault diagnosis 被引量:5
12
作者 高成 黄姣英 +1 位作者 孙悦 刁胜龙 《Journal of Central South University》 SCIE EI CAS 2012年第2期459-464,共6页
A relevance vector machine (RVM) based fault diagnosis method was presented for non-linear circuits. In order to simplify RVM classifier, parameters selection based on particle swarm optimization (PSO) and preprocessi... A relevance vector machine (RVM) based fault diagnosis method was presented for non-linear circuits. In order to simplify RVM classifier, parameters selection based on particle swarm optimization (PSO) and preprocessing technique based on the kurtosis and entropy of signals were used. Firstly, sinusoidal inputs with different frequencies were applied to the circuit under test (CUT). Then, the resulting frequency responses were sampled to generate features. The frequency response was sampled to compute its kurtosis and entropy, which can show the information capacity of signal. By analyzing the output signals, the proposed method can detect and identify faulty components in circuits. The results indicate that the fault classes can be classified correctly for at least 99% of the test data in example circuit. And the proposed method can diagnose hard and soft faults. 展开更多
关键词 电路故障诊断 粒子群优化 非线性电路 分类 故障诊断方法 频率响应 显示信号 预处理技术
下载PDF
Numerical simulation of non-contact explosion by door breaching explosive 被引量:1
13
作者 蒋飞 韩峰 王建中 《Journal of Beijing Institute of Technology》 EI CAS 2013年第1期1-5,共5页
Aiming at the estimation of personal injury attached by counter-terrorist door breaching explosive blast wave, according to the actual scene, four typical application space models of count- er-terrorist door breaching... Aiming at the estimation of personal injury attached by counter-terrorist door breaching explosive blast wave, according to the actual scene, four typical application space models of count- er-terrorist door breaching explosives are established, and numerical simulation of air-blast wave propagation by non-contact explosion counter-terrorist door breaching explosive are achieved. The research results show that the overpressure behind the target door is attenuated deeply through the burglary resistant safety door, and the propagation of blast wave and the damage effect under differ- ent space conditions are obviously different. 展开更多
关键词 non-contact explosion blast wave numerical simulation
下载PDF
Non-contact evaluation of the resonant frequency of a microstructure using ultrasonic wave 被引量:1
14
作者 X. Kang X. Y. He +1 位作者 C.J. Tay C. Quan 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 2010年第2期317-323,共7页
This paper presents a novel non-contact method for evaluating the resonant frequency of a microstructure, Firstly, the microstructure under test is excited by ultrasonic waves. This excitation method does not impose a... This paper presents a novel non-contact method for evaluating the resonant frequency of a microstructure, Firstly, the microstructure under test is excited by ultrasonic waves. This excitation method does not impose any undefined load on the specimen like the electrostatic excitation and also this is the first actual use of ultrasonic wave for exciting a microstructure in the literature. Secondly, the amplitudes of the microstructure are determined by image edge detection using a Mexican hat wavelet transform on the vibrating images of the microstructure. The vibrating images are captured by a CCD camera when the microstructure is vibrated by ultrasonic waves at a series of discrete high frequencies (〉30 kHz). Upon processing the vibrating images, the amplitudes at various excitation frequencies are obtained and an amplitude-frequency spectrum is obtained from which the resonant frequency is subsequently evaluated. A micro silicon structure consisting of a perforated plate (192 × 192 μm) and two cantilever beams (76 × 43 μm) which is about 4 μm thickness is tested. Since laser interferometry is not required, thermal effects on a test object can be avoided. Hence, the setup is relatively simple. Results show that the proposed method is a simple and effective approach for evaluating the dynamic characteristics of microstructures. 展开更多
关键词 non-contact Microstructure· Resonant frequency Ultrasonic wave Image processing
下载PDF
Non-Contact Method of Heart Rate Measurement Based on Facial Tracking 被引量:2
15
作者 Ruqiang Huang Weihua Su +1 位作者 Shiyue Zhang Wei Qin 《Journal of Computer and Communications》 2019年第5期17-28,共12页
Image photoplethysmography can realize low-cost and easy-to-operate non-contact heart rate detection from the facial video, and effectively overcome the limitations of traditional contact method in daily vital sign mo... Image photoplethysmography can realize low-cost and easy-to-operate non-contact heart rate detection from the facial video, and effectively overcome the limitations of traditional contact method in daily vital sign monitoring. However, it is hard to obtain more accurate heart rate detection values under the conditions of subject’s facial movement, weak ambient light intensity and long detection distance, etc. In this article, a non-contact heart rate detection method based on face tracking is proposed, which can effectively improve the accuracy of non-contact heart rate detection method in practical application. The corner tracker algorithm is used to track the human face to reduce the motion artifact caused by the movement of the subject’s face and enhance the use value of the signal. And the maximum ratio combining algorithm is used to weight the pixel space pulse wave signal in the facial region of interest to improve the pulse wave extraction accuracy. We analyzed the facial images collected under different experimental distances and action states. This proposed method significantly reduces the error rate compared with the independent component analysis method. After theoretical analysis and experimental verification, this method effectively reduces the error rate under different experimental variables and has good consistency with the heart rate value collected by the medical physiological vest. This method will help to improve the accuracy of non-contact heart rate detection in complex environments. 展开更多
关键词 HEART Rate non-contacting MAXIMUM RATIO COMBINING FACIAL Video
下载PDF
Calculation of the CO2 Degassing during Contact Metamorphism and Its Geological Significance:The Model and Example from the Shuanshan Area of the South Tan-Lu Fault Belt
16
作者 YANG Xiaoyong LIU Deliang +1 位作者 CHEN Yongjian DAI Jinxing 《Acta Geologica Sinica(English Edition)》 SCIE CAS CSCD 2008年第3期562-576,共15页
The paper studies CO2 degassing and controlling factors under the condition of contact metamorphism in the Shuangshan area, southern Tan-Lu fault belt and the method of calculating the amount of CO2 degassing. The res... The paper studies CO2 degassing and controlling factors under the condition of contact metamorphism in the Shuangshan area, southern Tan-Lu fault belt and the method of calculating the amount of CO2 degassing. The results show that the amount of CO2 degassing is controlled by the characteristics of the country rocks, including the thermal conductivity, penetrability, porosity and connectivity. Compositions, size and depth of intrusive rock also have an important influence on CO2 degassing, i.e., they generated numerous cracks in the country rocks, and thus allowed the easy flow and accumulation of fluids. The amount of CO2 flux in contact metamorphism is calculated quantitatively based on the metamorphic reaction and time-integrated fluid flux. The value (0.729- 2.446×10^4 mol/cm^2) of CO2 flux suggests that CO2 was provided mainly by the contact metamorphic reaction. The generation and releasing of CO2 are positively correlated with the degree of metamorphism, and XCO2 in fluids gradually increases from dolomite zone to calcite zone, but in the zone of grossular, fluid flux is the largest and XCO2 sharply decreases due to involvement of magmatic water. This study presents evidence that a large amount of industrial-scale CO2 can be produced during contact metamorphism. On the basis of theoretical and practical studies, a cone model has been proposed to response CO2 degassing for the contact metamorphism, and it can be used to explore CO2 accumulations beyond the oil-gas basins. This model can also be applied to the study of inorganic genesis of CO2 accumulations. 展开更多
关键词 contact metamorphism CO2 degassing CO2 accumulations Tan-Lu fault belt
下载PDF
A Simple Method to Derive Minimal Cut Sets for a Non-coherent Fault Tree 被引量:2
17
作者 Takehisa Kohda 《International Journal of Automation and computing》 EI 2006年第2期151-156,共6页
Minimal cut sets (or prime implicants: minimal combinations of basic event conditions leading to system failure) are important information for reliability/safety analysis and design. To obtain minimal cut sets for ... Minimal cut sets (or prime implicants: minimal combinations of basic event conditions leading to system failure) are important information for reliability/safety analysis and design. To obtain minimal cut sets for general non-coherent fault trees, including negative basic events or multi-valued basic events, a special procedure such as the consensus rule must be applied to the results obtained by logical operations for coherent fault trees, which will require more steps and time. This paper proposes a simple method for a non-coherent fault tree, whose top event is represented as an AND combination of monotonic sub-trees. A "monotonic" sub-tree means that it does not have both positive and negative representations for each basic event. It is proven that minimal cut sets can be obtained by a conventional method for coherent fault trees. An illustrative example of a simple event tree analysis shows the detail and characteristics of the proposed method. 展开更多
关键词 non-coherent fault trees monotonic sub-trees minimal cut sets.
下载PDF
Suppression of Vortex Precession in a Non-Contact Handling Device by a Circular Column 被引量:2
18
作者 Shouichiro Iio Katsuya Hayashi +3 位作者 Eri Akahane Yusuke Katayama Xin Li Toshiharu Kagawa 《Journal of Flow Control, Measurement & Visualization》 2016年第2期70-78,共9页
Vortex levitation attains non-contact handling by injecting air through a tangential nozzle into a cylindrical cup generating the swirling flow. The precessing of the swirling flow causes pressure fluctuation. This ph... Vortex levitation attains non-contact handling by injecting air through a tangential nozzle into a cylindrical cup generating the swirling flow. The precessing of the swirling flow causes pressure fluctuation. This phenomenon becomes apparent as the gap between the cup and workpiece increases, which significantly disturbs the stability of conveyance. In this paper, suppression of pressure fluctuation by a cylindrical column that stabilizes the vortex levitation is described and its mechanism is mentioned. According to the experimental set up, the pressure was measured at the center of the workpiece and the wall of the cup;velocity field under the work piece was visualized by PIV. The result suggested that the larger diameter column denoted the effect on suppression of the fluctuation because the precessing of the swirling flow became stable. On the other hand, variation of the column thickness had insignificant effect on suppressing the fluctuation, but sucking force became weakened since the swirling velocity decreased. 展开更多
关键词 non-contact Handling Swirling Flow Pressure Fluctuation VISUALIZATION
下载PDF
Non-contact monitoring and analysis system for tunnel surrounding rock deformation of underground engineering 被引量:1
19
作者 YANG Song-lin, WANG Bin, JI Sheng-yue, LIU Wei-ning, SHI Hong-yun (Beijing Jiaotong University, Beijing 100044, China) 《中国有色金属学会会刊:英文版》 CSCD 2005年第S1期96-99,共4页
It is very important to monitor surrounding rock deformation in tunnel construction. The principle, function, development and application of the system composed of a total station and computer for monitoring and analy... It is very important to monitor surrounding rock deformation in tunnel construction. The principle, function, development and application of the system composed of a total station and computer for monitoring and analyzing surrounding rock deformation were discussed. The new methods of two free station of 3D measurement and its mathematic adjustment mode were presented. The development of software for total station on-board and post for computer were also described. Without centering it and measuring its height, the total station controlled by the software on-board can fulfill the whole measurements to target points. Monitoring data can be processed by the post software and results of regression analysis, forecasting information of the tunnel surrounding rock deformation can be provided in time. The practical use shows that this system is practicable, highly accurate and efficient. It satisfies the needs of safety and information construction in tunnel construction of underground engineering. 展开更多
关键词 TUNNEL construction deformation of SURROUNDING ROCK TOTAL STATION non-contact monitoring data processing and analysis
下载PDF
Non-contact ECG Monitoring Based on Capacitive Electrodes 被引量:1
20
作者 ZHOU Ping LI Zhou-cheng +1 位作者 WANG Feng JIAO Hong-yu 《Chinese Journal of Biomedical Engineering(English Edition)》 2012年第3期98-103,共6页
Recent interest in mobile-based healthcare has driven significant demands on researching non-contact electrodes for electrocardiogram (ECG)measurement. While the conductive gel achieves the requirement in making a goo... Recent interest in mobile-based healthcare has driven significant demands on researching non-contact electrodes for electrocardiogram (ECG)measurement. While the conductive gel achieves the requirement in making a good contact between the electrodes and skin, several problems appear. A gel-free,non-contact electrode based on capacitive coupling theory was provided in this paper,which was integrated on the print circuit board (PCB). The experimental results showed that clear ECG signals could be acquired in the laboratory conditions by coupling the electrodes to the chest of patients through cotton belts. 展开更多
关键词 非接触式 电极 心电监护 电容 实验室条件 耦合理论 印刷电路板 心电图
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部