This paper discusses a study in which Ti surface alloying has been performed on copper substrates by means of a double glow discharge plasma surface alloying technique. The micro-structure, the phase structure, the mi...This paper discusses a study in which Ti surface alloying has been performed on copper substrates by means of a double glow discharge plasma surface alloying technique. The micro-structure, the phase structure, the micro-hardness and the distribution of Ti concentration of alloying layer were investigated in detail by XRD, SEM and so on. The effect of process parameters on the alloying layer was studied. The experimental results show that a Ti solid solution with the precipitation Cu4Ti alloying layer has been formed on the copper surface. The thickness of the alloying layer is about 120 μm and the surface titanium concentration gradually decreases from ω (Ti) = 87% to ω (Ti) = 4%. The micro-hardness of the alloying layer is between 300 HV-800 HV. Source sputtering, surface absorption, ion bombarding and high temperature diffusion are the major factors that affect the alloying layer.展开更多
The spark plasma sintering (SPS) method is used to prepare the ultrafine copper with the average grain size less than 10 μm and the tensile strength greater than 280 MPa.The ultrafine copper is annealed at differen...The spark plasma sintering (SPS) method is used to prepare the ultrafine copper with the average grain size less than 10 μm and the tensile strength greater than 280 MPa.The ultrafine copper is annealed at different temperatures for 60 min,and the annealing microstructure is observed and the hardness and the deformation behavior of the bulk copper are tested.The results indicate that the grains grow very slowly when the annealing temperature is less than 450 ℃.However,the grain growth becomes remarkable when the annealing temperature exceeds 450 ℃.And the plasticity of the bulk copper is the best when the annealing temperature of 450 ℃ is adopted.After stamping and spin forming,the deformed copper is recrystallized completely and the grain is refined when the copper is annealed at 500 ℃ for 30 min.展开更多
The determination of copper by MIP-AES was investigated in detail. Aqueous samples were introduced from an ultrasonic nebulizer and the solvent was removed by a desolvation device before introduction of the aerosol in...The determination of copper by MIP-AES was investigated in detail. Aqueous samples were introduced from an ultrasonic nebulizer and the solvent was removed by a desolvation device before introduction of the aerosol into the MIP. The desolvation system consisted of a condenser associated with a concentrated H2SO4 absorption cell. Various experimental conditions and interferences from easily ionised elements (EIEs) were also studied and some practical samples were analyzed.展开更多
The experimental system for electrically exploding single metal wire has been designed and manufactured. Expansion of the dense plasma column formed from an electrically exploding Cu wire of diameter 30 μm has been s...The experimental system for electrically exploding single metal wire has been designed and manufactured. Expansion of the dense plasma column formed from an electrically exploding Cu wire of diameter 30 μm has been studied with a high-speed photographer to obtain the time-dependent radius (R-t) curve. The experimental results demonstrate that the mean expansion rate of the dense plasma column is 1.94 μm/ns, 2.6 μm/ns and 3.75 μm/ns according to the peak pulse current 4.5 kA, 7 kA and 9.5 kA respectively. The results can be beneficial to giving a profound understanding of the early stage of wire-array Z-pinch physics and to improvement on their design.展开更多
A two-dimensional axisymmetric model,with 8700 and 7500 quadrilateral elements for the fluid and substrate zone separately,was developed to simulate the impacting and flattening process. The volume of fluid technique ...A two-dimensional axisymmetric model,with 8700 and 7500 quadrilateral elements for the fluid and substrate zone separately,was developed to simulate the impacting and flattening process. The volume of fluid technique was employed to track the interface between the air and droplet. The relationships between the droplet pre-impact parameters and the flattening time as well as the flattening ratio were investigated by altering one of the parameters while remaining the others unchanged. The results show that the droplet height reaches its minimum value at approximately half of the spreading time,which also indicates the finish of vertical fluid flow at that time. The flattening ratio increases with the increase of the three pre-impact parameters-droplet diameter,temperature and velocity,even though the flattening time decreases when the droplet velocity increase.展开更多
Direct analysis of copper-base alloys using laser ablation techniques is an increasingly common procedure in cultural heritage studies. However, main discussions remain focused on the possibility of using non-matrix m...Direct analysis of copper-base alloys using laser ablation techniques is an increasingly common procedure in cultural heritage studies. However, main discussions remain focused on the possibility of using non-matrix matched external reference materials. To evaluate the occurrence of matrix effects during in situ microanalysis of copper-base materials, using near infrared femtosecond laser ablation techniques (NIR fs-LA-ICP-MS), two bronzes, i.e., (Sn-Zn)-ternary and (Sn)-binary copper-matrix reference materials, as well as a reference synthetic glass (NIST-SRM-610) have been analyzed. The results have been compared to data obtained on a sulfide-matrix reference material. Similar values in relative sensitivity averages of 63Cu, 118Sn and 66Zn, as well as in 118Sn/63Cu and 66Zn/63Cu ratios were obtained, for all analyzed matrix types, i.e., copper-base-, silicate-, and sulfide-reference materials. Consequently, it is possible to determinate major and minor element concentrations in copper alloys, i.e., Cu, Sn and Zn, using silicate and sulfide reference materials as external calibrators, without any matrix effect and over a wide range of concentrations (from wt.% to ppm). Equally, Cu, Sn and Zn concentrations can be precisely determined in sulfides using homogeneous alloys (reference) materials as an external calibrator. Thus, it is possible to determine Cu, Sn and Zn in copper-base materials and their ore minerals, mostly sulfides, in a single analytical session, without requiring specific external calibrators for each matrix type. In contrast, immiscible elements in copper matrix, such as Pb and Fe show notable differences in their relative sensitivity values and ratios for different matrix-materials analyzed, implying that matrix-matched external calibrations remain to be applied for their trace quantification.展开更多
文摘This paper discusses a study in which Ti surface alloying has been performed on copper substrates by means of a double glow discharge plasma surface alloying technique. The micro-structure, the phase structure, the micro-hardness and the distribution of Ti concentration of alloying layer were investigated in detail by XRD, SEM and so on. The effect of process parameters on the alloying layer was studied. The experimental results show that a Ti solid solution with the precipitation Cu4Ti alloying layer has been formed on the copper surface. The thickness of the alloying layer is about 120 μm and the surface titanium concentration gradually decreases from ω (Ti) = 87% to ω (Ti) = 4%. The micro-hardness of the alloying layer is between 300 HV-800 HV. Source sputtering, surface absorption, ion bombarding and high temperature diffusion are the major factors that affect the alloying layer.
基金Sponsored by Program for Peking Excellent Talents in University(20061D0503200316)
文摘The spark plasma sintering (SPS) method is used to prepare the ultrafine copper with the average grain size less than 10 μm and the tensile strength greater than 280 MPa.The ultrafine copper is annealed at different temperatures for 60 min,and the annealing microstructure is observed and the hardness and the deformation behavior of the bulk copper are tested.The results indicate that the grains grow very slowly when the annealing temperature is less than 450 ℃.However,the grain growth becomes remarkable when the annealing temperature exceeds 450 ℃.And the plasticity of the bulk copper is the best when the annealing temperature of 450 ℃ is adopted.After stamping and spin forming,the deformed copper is recrystallized completely and the grain is refined when the copper is annealed at 500 ℃ for 30 min.
基金Supported by the Natinoal Natural Science Foundation of China.
文摘The determination of copper by MIP-AES was investigated in detail. Aqueous samples were introduced from an ultrasonic nebulizer and the solvent was removed by a desolvation device before introduction of the aerosol into the MIP. The desolvation system consisted of a condenser associated with a concentrated H2SO4 absorption cell. Various experimental conditions and interferences from easily ionised elements (EIEs) were also studied and some practical samples were analyzed.
基金The project supported by Pre-research Foundation of Chinese Acadeny of Engineering Physics(No.20010103)
文摘The experimental system for electrically exploding single metal wire has been designed and manufactured. Expansion of the dense plasma column formed from an electrically exploding Cu wire of diameter 30 μm has been studied with a high-speed photographer to obtain the time-dependent radius (R-t) curve. The experimental results demonstrate that the mean expansion rate of the dense plasma column is 1.94 μm/ns, 2.6 μm/ns and 3.75 μm/ns according to the peak pulse current 4.5 kA, 7 kA and 9.5 kA respectively. The results can be beneficial to giving a profound understanding of the early stage of wire-array Z-pinch physics and to improvement on their design.
基金Project (50675072) supported by the National Natural Science Foundation of ChinaProject (E0610018) supported by the Natural Science Foundation of Fujian Province, ChinaProject (20062178) supported by the Natural Science Foundation of Liaoning Province, China
文摘A two-dimensional axisymmetric model,with 8700 and 7500 quadrilateral elements for the fluid and substrate zone separately,was developed to simulate the impacting and flattening process. The volume of fluid technique was employed to track the interface between the air and droplet. The relationships between the droplet pre-impact parameters and the flattening time as well as the flattening ratio were investigated by altering one of the parameters while remaining the others unchanged. The results show that the droplet height reaches its minimum value at approximately half of the spreading time,which also indicates the finish of vertical fluid flow at that time. The flattening ratio increases with the increase of the three pre-impact parameters-droplet diameter,temperature and velocity,even though the flattening time decreases when the droplet velocity increase.
文摘Direct analysis of copper-base alloys using laser ablation techniques is an increasingly common procedure in cultural heritage studies. However, main discussions remain focused on the possibility of using non-matrix matched external reference materials. To evaluate the occurrence of matrix effects during in situ microanalysis of copper-base materials, using near infrared femtosecond laser ablation techniques (NIR fs-LA-ICP-MS), two bronzes, i.e., (Sn-Zn)-ternary and (Sn)-binary copper-matrix reference materials, as well as a reference synthetic glass (NIST-SRM-610) have been analyzed. The results have been compared to data obtained on a sulfide-matrix reference material. Similar values in relative sensitivity averages of 63Cu, 118Sn and 66Zn, as well as in 118Sn/63Cu and 66Zn/63Cu ratios were obtained, for all analyzed matrix types, i.e., copper-base-, silicate-, and sulfide-reference materials. Consequently, it is possible to determinate major and minor element concentrations in copper alloys, i.e., Cu, Sn and Zn, using silicate and sulfide reference materials as external calibrators, without any matrix effect and over a wide range of concentrations (from wt.% to ppm). Equally, Cu, Sn and Zn concentrations can be precisely determined in sulfides using homogeneous alloys (reference) materials as an external calibrator. Thus, it is possible to determine Cu, Sn and Zn in copper-base materials and their ore minerals, mostly sulfides, in a single analytical session, without requiring specific external calibrators for each matrix type. In contrast, immiscible elements in copper matrix, such as Pb and Fe show notable differences in their relative sensitivity values and ratios for different matrix-materials analyzed, implying that matrix-matched external calibrations remain to be applied for their trace quantification.