AIM:To develop normative data for meibomian gland dysfunction(MGD)parameters,using non-contact meibography technique of Sirius Costruzione Strumenti Oftalmici(CSO)machine,in an Egyptian population sample.METHODS:Obser...AIM:To develop normative data for meibomian gland dysfunction(MGD)parameters,using non-contact meibography technique of Sirius Costruzione Strumenti Oftalmici(CSO)machine,in an Egyptian population sample.METHODS:Observational,cross-sectional,analytic study,in which 104 Egyptian volunteers were included.Both upper lids were examined,using“Sirius CSO”machine.Each eyelid was given a degree of meibomian gland loss(MGL),which was calculated by the software of the machine.RESULTS:Mean percentage MGL in right upper lid was of 30.9%±12.6%,and that of left upper lid was 32.6%±11.8%.Thirty-four volunteers(32.7%)had first-degree MGL in their right upper lid,and 67.3%had second-degree loss.One volunteer(1%)had zero-degree MGL in left upper lid,28(26.9%)had first-degree loss,and 75(72.1%)had second-degree loss.Degree of MGL in right upper eyelid was not related to age,but degree of MGL in left upper eyelid increased with age.There was statistically significant difference between both genders for degree of MGL in right eye(P=0.036)and in left eye(P=0.027).CONCLUSION:Noncontact meibography is a useful non-invasive tool for diagnosing MGL.MGL is diagnosed in 100%of apparently normal individuals;26.9%-32.7%of which have first-degree MGL,and 67.3%-72.1%have second-degree MGL.展开更多
AIM:To evaluate scleral buckling(SB)surgery using a noncontact wide-field viewing system and 23-gauge intraocular illumination for the treatment of rhegmatogenous retinal detachment in silicone oil(SO)-filled eyes.MET...AIM:To evaluate scleral buckling(SB)surgery using a noncontact wide-field viewing system and 23-gauge intraocular illumination for the treatment of rhegmatogenous retinal detachment in silicone oil(SO)-filled eyes.METHODS:Totally 9 patients(9 eyes)with retinal detachment in SO-filled eyes were retrospectively analyzed.All patients underwent non-contact wide-field viewing system-assisted buckling surgery with 23-gauge intraocular illumination.SO was removed at an appropriate time based on recovery.The patients were followed up for at least 3mo after SO removal.Retinal reattachment,complications,visual acuity and intraocular pressure(IOP)before and after surgery were observed.RESULTS:Patients were followed up for a mean of 8.22mo(3-22mo)after SO removal.All patients had retinal reattachment.At the final follow-up,visual acuity showed improvement for 8 patients,and no change for 1 patient.The IOP was high in 3 patients before surgery,but it stabilized after treatment;it was not affected in the other patients.None of the patients had infections,hemorrhage,anterior ischemia,or any other complication.CONCLUSION:This new non-contact wide-field viewing system-assisted SB surgery with 23-gauge intraocular illumination is effective and safe for retinal detachment in SO-filled eyes.展开更多
Deception detection plays a crucial role in criminal investigation.Videos contain a wealth of information regarding apparent and physiological changes in individuals,and thus can serve as an effective means of decepti...Deception detection plays a crucial role in criminal investigation.Videos contain a wealth of information regarding apparent and physiological changes in individuals,and thus can serve as an effective means of deception detection.In this paper,we investigate video-based deception detection considering both apparent visual features such as eye gaze,head pose and facial action unit(AU),and non-contact heart rate detected by remote photoplethysmography(rPPG)technique.Multiple wrapper-based feature selection methods combined with the K-nearest neighbor(KNN)and support vector machine(SVM)classifiers are employed to screen the most effective features for deception detection.We evaluate the performance of the proposed method on both a self-collected physiological-assisted visual deception detection(PV3D)dataset and a public bag-oflies(BOL)dataset.Experimental results demonstrate that the SVM classifier with symbiotic organisms search(SOS)feature selection yields the best overall performance,with an area under the curve(AUC)of 83.27%and accuracy(ACC)of 83.33%for PV3D,and an AUC of 71.18%and ACC of 70.33%for BOL.This demonstrates the stability and effectiveness of the proposed method in video-based deception detection tasks.展开更多
To control drug effects by detecting temperature difference between biologically active point(BAP)and intact area of skin for treatment of mental illness,a device is developed for monitoring the temperature of BAP a...To control drug effects by detecting temperature difference between biologically active point(BAP)and intact area of skin for treatment of mental illness,a device is developed for monitoring the temperature of BAP and the dose medication and its change in real time to increase effectiveness of treatment.Two electrodes by Foll R method are used and BAP is determined based on topographic anatomical reference points.The temperature values are measured by integral thermometers DS18B20.the received data are processed and temperature difference is calculated and displayed under the control of microcontroller Atmega32.The obtained data confirm the correlation between the temperature difference indicators BAP C7,Gi4 and neurological scales assessing severity of mental illness.The experimetal results show that the temperature difference can be criteria for evaluating the effects of drugs,which is the basis for computer control systems of of medical process of mental patients.展开更多
The recently discovered Damoqujia (大磨曲家) gold deposit is a large shear zone-hosted gold deposit of disseminated sulphides located in the north of the Zhaoping (招平) fault zone, Jiaodong (胶东) gold province...The recently discovered Damoqujia (大磨曲家) gold deposit is a large shear zone-hosted gold deposit of disseminated sulphides located in the north of the Zhaoping (招平) fault zone, Jiaodong (胶东) gold province, China. In order to distinguish the temperature range of cluster inclusions from different mineralization stages and measure their compositions, 16 fluid inclusions and 5 isotopic geochemistry samples were collected for this study. Corresponding to different mineralization stages, the multirange peaks of quartz decrepitation temperature (250-270, 310-360 and 380-430℃) indicate that the activity of ore-forming fluids is characterized by multistage. The ore-forming fluids were predominantly of high-temperature fluid system (HTFS) by CO2-rich, and SO4^2--K^+ type magmatic fluid during the early stage of mineralization and were subsequently affected by low-temperature fluid system (LTFS) of CH4-rich, and Cl^--Na^+/Ca^2+ type meteoric fluid during the late stage of mineralization. Gold is transferred by Au-HS^- complex in the HTFS, and Au-Cl^- complex can be more important in the LTFS. The transition of fluids from deeper to shallow environments results in mixing between the HTFS and LTFS, which might be one of the most key reasons for gold precipitation and large-scale mineralization. The ore-forming fluids are characterized by high-temperature, strong-activity, and superimposed mineralization, so that there is a great probability of forming large and rich ore deposit in the Damoqujia gold deposit. The main bodies are preserved and extend toward deeper parts, thereby suggesting a great potential in future.展开更多
The effect of arc on radiation thermometry is analyzed in a field close to the arc during the welding process, and the ratio of signal to noise and other factors are obtained for a small current arc .The method of the...The effect of arc on radiation thermometry is analyzed in a field close to the arc during the welding process, and the ratio of signal to noise and other factors are obtained for a small current arc .The method of the temperature measurement is feasible when the arc current is decreased to a smaller value in the welding process.展开更多
In order to overcome the effect of the assumption between emissivity and wavelength on the measurement of true temperature and spectral emissivity for most engineering materials, a neural network based method is propo...In order to overcome the effect of the assumption between emissivity and wavelength on the measurement of true temperature and spectral emissivity for most engineering materials, a neural network based method is proposed for data processing while a blackbody furnace and three optical filters with known spectral transmittance curves were used to make up a true target. The experimental results show that the calculated temperatures are in good agreement with the temperature of the blackbody furnace, and the calculated spectral emissivity curves are in good agreement with the spectral transmittance curves of the filters. The method proposed has been proved to be an effective method for solving the problem of true temperature and emissivity measurement, and it can overcome the effect of the assumption between emissivity and wavelength on the measurement of true temperature and spectral emissivity for most engineering materials.展开更多
Based on the development of the non-contact measurement system of free-formsurface, NURBS reconstruction of measurement points of freeform surface is effectively realized bymodifying the objective function and recursi...Based on the development of the non-contact measurement system of free-formsurface, NURBS reconstruction of measurement points of freeform surface is effectively realized bymodifying the objective function and recursive procedure and calculating the optimum number ofcontrol points. The reconstruction precision is evaluated through Ja-cobi's transformation method.The feasibility of the measurement system and effectiveness of the reconstruction algorithm aboveare proved by experiment.展开更多
At present, an automatic-mechanic contact tap-changer is widely used in power system, but it can not frequently operate. In addition, arc will occur when the switch changes. In order to solve these two problems, this ...At present, an automatic-mechanic contact tap-changer is widely used in power system, but it can not frequently operate. In addition, arc will occur when the switch changes. In order to solve these two problems, this paper presented an automatic on-load voltage-regulating distributing transformer which employed non-contact solid-state relay as tap-changer, and mainly introduced its structure, basic principal, design method of each key link and experimental results. Laboratory simulation experiments informed that the scheme was feasible. It was a smooth and effective experiment device, which was practical in application.展开更多
Many structures and materials in nature and physiology have important "meso-scale" structures at the micron lengthscale whose tensile responses have proven difficult to characterize mechanically. Although techniques...Many structures and materials in nature and physiology have important "meso-scale" structures at the micron lengthscale whose tensile responses have proven difficult to characterize mechanically. Although techniques such as atomic force microscopy and micro- and nano-identation are mature for compression and indentation testing at the nano-scale, and standard uniaxial and shear rheometry techniques exist for the macroscale, few techniques are applicable for tensile-testing at the micrometre-scale, leaving a gap in our understanding of hierarchical biomaterials. Here, we present a novel magnetic mechanical testing (MMT) system that enables viscoelastic tensile testing at this critical length scale. The MMT system applies non-contact loading, avoiding gripping and surface interaction effects. We demonstrate application of the MMT system to the first analyses of the pure tensile responses of several native and engineered tissue systems at the mesoscale, showing the broad potential of the system for exploring micro- and meso-scale analysis of structured and hierarchical biological systems.展开更多
A precise aperture measuring system of small deep holes with capacitance sensors is presented. Based on the working principle of non-contact capacitance sensors, influence of the edge effect of gauge head is studied, ...A precise aperture measuring system of small deep holes with capacitance sensors is presented. Based on the working principle of non-contact capacitance sensors, influence of the edge effect of gauge head is studied, and one capacitance sensor for measuring the aperture of the small blind holes or through holes is introduced. The system is composed of one positioning device, one aperture measuring capacitance sensor, one measuring circuit, and software. This system employs visual CCD and two-dimensional mic...展开更多
Non-contact sensing can be a rapid and convenient alternative for determining structure response compared to conventional instrumentation.Computer vision has been broadly implemented to enable accurate non-contact dyn...Non-contact sensing can be a rapid and convenient alternative for determining structure response compared to conventional instrumentation.Computer vision has been broadly implemented to enable accurate non-contact dynamic response measurements for structures.This study has analyzed the effect of non-contact sensors,including type,frame rate,and data collection platform,on the performance of a novel motion detection technique.Video recordings of a cantilever column were collected using a high-speed camera mounted on a tripod and an unmanned aerial system(UAS)equipped with visual and thermal sensors.The test specimen was subjected to an initial deformation and released.Specimen acceleration data were collected using an accelerometer installed on the cantilever end.The displacement from each non-contact sensor and the acceleration from the contact sensor were analyzed to measure the specimen′s natural frequency and damping ratio.The specimen′s first fundamental frequency and damping ratio results were validated by analyzing acceleration data from the top of the specimen and a finite element model.展开更多
The severe acute respiratory syndrome coronavirus 2(SARS-CoV-2),which caused the coronavirus disease 2019(COVID-19)pandemic,has affected more than 400 million people worldwide.With the recent rise of new Delta and Omi...The severe acute respiratory syndrome coronavirus 2(SARS-CoV-2),which caused the coronavirus disease 2019(COVID-19)pandemic,has affected more than 400 million people worldwide.With the recent rise of new Delta and Omicron variants,the efficacy of the vaccines has become an important question.The goal of various studies has been to limit the spread of the virus by utilizing wireless sensing technologies to prevent human-to-human interactions,particularly for healthcare workers.In this paper,we discuss the current literature on invasive/contact and non-invasive/noncontact technologies(including Wi-Fi,radar,and software-defined radio)that have been effectively used to detect,diagnose,and monitor human activities and COVID-19 related symptoms,such as irregular respiration.In addition,we focused on cutting-edge machine learning algorithms(such as generative adversarial networks,random forest,multilayer perceptron,support vector machine,extremely randomized trees,and k-nearest neighbors)and their essential role in intelligent healthcare systems.Furthermore,this study highlights the limitations related to non-invasive techniques and prospective research directions.展开更多
A novel non-contact spacecraft architecture with the extended stochastic state observer for disturbance rejection control of the gravity satellite is proposed.First,the precise linear driving non-contact voice-coil ac...A novel non-contact spacecraft architecture with the extended stochastic state observer for disturbance rejection control of the gravity satellite is proposed.First,the precise linear driving non-contact voice-coil actuators are used to separate the whole spacecraft into the non-contact payload module and the service module,and to build an ideal loop with precise dynamics for disturbance rejection control of the payload module.Second,an extended stochastic state observer is enveloped to construct the overall nonlinear external terms and the internal coupled terms of the payload module,enabling the controller design of the payload module turned into the linear form with simple bandwidth-parameterization tuning in the frequency domain.As a result,the disturbance rejection control of the payload module can be explicitly achieved in a timely manner without complicated tuning in actual implementation.Finally,an extensive numerical simulation is conducted to validate the feasibility and effectiveness of the proposed approach.展开更多
This study aimed to produce a prototype system for non-contact vital sign monitoring of the elderly using microwave radar with the intention of reducing the burdens on monitored individuals and nursing caregivers. In ...This study aimed to produce a prototype system for non-contact vital sign monitoring of the elderly using microwave radar with the intention of reducing the burdens on monitored individuals and nursing caregivers. In addition, we tested the ability of the proposed prototype system to measure the respiratory and heart rates of the elderly in a nursing home and discussed the systems effectiveness and problems by examining results of real-time monitoring. The prototype system consisted of two 24-GHz microwave radar antennas and an analysis system. The antennas were positioned below a mattress to monitor motion on the body surface for measuring cardiac and respiratory rates from the dorsal side of the subjects (23.3 ± 1.2 years) who would be lying on the mattress. The heart rates determined by the prototype system correlated significantly with those measured by electrocardiography (r = 0.92). Similarly, the respiratory rates determined by the prototype correlated with those obtained from respiration curves (r = 0.94). Next, we investigated the effectiveness of the prototype system with 7 elderly patients (93.3 ± 10.56 years) at a nursing home. The proposed system appears to be a promising tool for monitoring the vital signs of the elderly in a way that alleviates the need to attach electrodes overnight to confirm patient safety.展开更多
This paper presents a novel non-contact method for evaluating the resonant frequency of a microstructure, Firstly, the microstructure under test is excited by ultrasonic waves. This excitation method does not impose a...This paper presents a novel non-contact method for evaluating the resonant frequency of a microstructure, Firstly, the microstructure under test is excited by ultrasonic waves. This excitation method does not impose any undefined load on the specimen like the electrostatic excitation and also this is the first actual use of ultrasonic wave for exciting a microstructure in the literature. Secondly, the amplitudes of the microstructure are determined by image edge detection using a Mexican hat wavelet transform on the vibrating images of the microstructure. The vibrating images are captured by a CCD camera when the microstructure is vibrated by ultrasonic waves at a series of discrete high frequencies (〉30 kHz). Upon processing the vibrating images, the amplitudes at various excitation frequencies are obtained and an amplitude-frequency spectrum is obtained from which the resonant frequency is subsequently evaluated. A micro silicon structure consisting of a perforated plate (192 × 192 μm) and two cantilever beams (76 × 43 μm) which is about 4 μm thickness is tested. Since laser interferometry is not required, thermal effects on a test object can be avoided. Hence, the setup is relatively simple. Results show that the proposed method is a simple and effective approach for evaluating the dynamic characteristics of microstructures.展开更多
Aiming at the estimation of personal injury attached by counter-terrorist door breaching explosive blast wave, according to the actual scene, four typical application space models of count- er-terrorist door breaching...Aiming at the estimation of personal injury attached by counter-terrorist door breaching explosive blast wave, according to the actual scene, four typical application space models of count- er-terrorist door breaching explosives are established, and numerical simulation of air-blast wave propagation by non-contact explosion counter-terrorist door breaching explosive are achieved. The research results show that the overpressure behind the target door is attenuated deeply through the burglary resistant safety door, and the propagation of blast wave and the damage effect under differ- ent space conditions are obviously different.展开更多
Image photoplethysmography can realize low-cost and easy-to-operate non-contact heart rate detection from the facial video, and effectively overcome the limitations of traditional contact method in daily vital sign mo...Image photoplethysmography can realize low-cost and easy-to-operate non-contact heart rate detection from the facial video, and effectively overcome the limitations of traditional contact method in daily vital sign monitoring. However, it is hard to obtain more accurate heart rate detection values under the conditions of subject’s facial movement, weak ambient light intensity and long detection distance, etc. In this article, a non-contact heart rate detection method based on face tracking is proposed, which can effectively improve the accuracy of non-contact heart rate detection method in practical application. The corner tracker algorithm is used to track the human face to reduce the motion artifact caused by the movement of the subject’s face and enhance the use value of the signal. And the maximum ratio combining algorithm is used to weight the pixel space pulse wave signal in the facial region of interest to improve the pulse wave extraction accuracy. We analyzed the facial images collected under different experimental distances and action states. This proposed method significantly reduces the error rate compared with the independent component analysis method. After theoretical analysis and experimental verification, this method effectively reduces the error rate under different experimental variables and has good consistency with the heart rate value collected by the medical physiological vest. This method will help to improve the accuracy of non-contact heart rate detection in complex environments.展开更多
It is very important to monitor surrounding rock deformation in tunnel construction. The principle, function, development and application of the system composed of a total station and computer for monitoring and analy...It is very important to monitor surrounding rock deformation in tunnel construction. The principle, function, development and application of the system composed of a total station and computer for monitoring and analyzing surrounding rock deformation were discussed. The new methods of two free station of 3D measurement and its mathematic adjustment mode were presented. The development of software for total station on-board and post for computer were also described. Without centering it and measuring its height, the total station controlled by the software on-board can fulfill the whole measurements to target points. Monitoring data can be processed by the post software and results of regression analysis, forecasting information of the tunnel surrounding rock deformation can be provided in time. The practical use shows that this system is practicable, highly accurate and efficient. It satisfies the needs of safety and information construction in tunnel construction of underground engineering.展开更多
文摘AIM:To develop normative data for meibomian gland dysfunction(MGD)parameters,using non-contact meibography technique of Sirius Costruzione Strumenti Oftalmici(CSO)machine,in an Egyptian population sample.METHODS:Observational,cross-sectional,analytic study,in which 104 Egyptian volunteers were included.Both upper lids were examined,using“Sirius CSO”machine.Each eyelid was given a degree of meibomian gland loss(MGL),which was calculated by the software of the machine.RESULTS:Mean percentage MGL in right upper lid was of 30.9%±12.6%,and that of left upper lid was 32.6%±11.8%.Thirty-four volunteers(32.7%)had first-degree MGL in their right upper lid,and 67.3%had second-degree loss.One volunteer(1%)had zero-degree MGL in left upper lid,28(26.9%)had first-degree loss,and 75(72.1%)had second-degree loss.Degree of MGL in right upper eyelid was not related to age,but degree of MGL in left upper eyelid increased with age.There was statistically significant difference between both genders for degree of MGL in right eye(P=0.036)and in left eye(P=0.027).CONCLUSION:Noncontact meibography is a useful non-invasive tool for diagnosing MGL.MGL is diagnosed in 100%of apparently normal individuals;26.9%-32.7%of which have first-degree MGL,and 67.3%-72.1%have second-degree MGL.
基金Supported by National Natural Science Foundation of China(No.81700884)Scientific Research Foundation of National Health and Health Commission(No.WKJ-ZJ-2037)+1 种基金Zhejiang Public Welfare Technology Application Project(No.LGF21H120005)Science and Technology Project of Wenzhou(No.Y20190649).
文摘AIM:To evaluate scleral buckling(SB)surgery using a noncontact wide-field viewing system and 23-gauge intraocular illumination for the treatment of rhegmatogenous retinal detachment in silicone oil(SO)-filled eyes.METHODS:Totally 9 patients(9 eyes)with retinal detachment in SO-filled eyes were retrospectively analyzed.All patients underwent non-contact wide-field viewing system-assisted buckling surgery with 23-gauge intraocular illumination.SO was removed at an appropriate time based on recovery.The patients were followed up for at least 3mo after SO removal.Retinal reattachment,complications,visual acuity and intraocular pressure(IOP)before and after surgery were observed.RESULTS:Patients were followed up for a mean of 8.22mo(3-22mo)after SO removal.All patients had retinal reattachment.At the final follow-up,visual acuity showed improvement for 8 patients,and no change for 1 patient.The IOP was high in 3 patients before surgery,but it stabilized after treatment;it was not affected in the other patients.None of the patients had infections,hemorrhage,anterior ischemia,or any other complication.CONCLUSION:This new non-contact wide-field viewing system-assisted SB surgery with 23-gauge intraocular illumination is effective and safe for retinal detachment in SO-filled eyes.
基金National Natural Science Foundation of China(No.62271186)Anhui Key Project of Research and Development Plan(No.202104d07020005)。
文摘Deception detection plays a crucial role in criminal investigation.Videos contain a wealth of information regarding apparent and physiological changes in individuals,and thus can serve as an effective means of deception detection.In this paper,we investigate video-based deception detection considering both apparent visual features such as eye gaze,head pose and facial action unit(AU),and non-contact heart rate detected by remote photoplethysmography(rPPG)technique.Multiple wrapper-based feature selection methods combined with the K-nearest neighbor(KNN)and support vector machine(SVM)classifiers are employed to screen the most effective features for deception detection.We evaluate the performance of the proposed method on both a self-collected physiological-assisted visual deception detection(PV3D)dataset and a public bag-oflies(BOL)dataset.Experimental results demonstrate that the SVM classifier with symbiotic organisms search(SOS)feature selection yields the best overall performance,with an area under the curve(AUC)of 83.27%and accuracy(ACC)of 83.33%for PV3D,and an AUC of 71.18%and ACC of 70.33%for BOL.This demonstrates the stability and effectiveness of the proposed method in video-based deception detection tasks.
文摘To control drug effects by detecting temperature difference between biologically active point(BAP)and intact area of skin for treatment of mental illness,a device is developed for monitoring the temperature of BAP and the dose medication and its change in real time to increase effectiveness of treatment.Two electrodes by Foll R method are used and BAP is determined based on topographic anatomical reference points.The temperature values are measured by integral thermometers DS18B20.the received data are processed and temperature difference is calculated and displayed under the control of microcontroller Atmega32.The obtained data confirm the correlation between the temperature difference indicators BAP C7,Gi4 and neurological scales assessing severity of mental illness.The experimetal results show that the temperature difference can be criteria for evaluating the effects of drugs,which is the basis for computer control systems of of medical process of mental patients.
基金supported by the National Natural Science Foundation of China (Nos. 40672064, 40572063)the 973-Project (No. 2006CB403506)Changjiang Scholars and Innovative Research Team in University and 111 Project of the Ministry of Education, China (No. B07011)
文摘The recently discovered Damoqujia (大磨曲家) gold deposit is a large shear zone-hosted gold deposit of disseminated sulphides located in the north of the Zhaoping (招平) fault zone, Jiaodong (胶东) gold province, China. In order to distinguish the temperature range of cluster inclusions from different mineralization stages and measure their compositions, 16 fluid inclusions and 5 isotopic geochemistry samples were collected for this study. Corresponding to different mineralization stages, the multirange peaks of quartz decrepitation temperature (250-270, 310-360 and 380-430℃) indicate that the activity of ore-forming fluids is characterized by multistage. The ore-forming fluids were predominantly of high-temperature fluid system (HTFS) by CO2-rich, and SO4^2--K^+ type magmatic fluid during the early stage of mineralization and were subsequently affected by low-temperature fluid system (LTFS) of CH4-rich, and Cl^--Na^+/Ca^2+ type meteoric fluid during the late stage of mineralization. Gold is transferred by Au-HS^- complex in the HTFS, and Au-Cl^- complex can be more important in the LTFS. The transition of fluids from deeper to shallow environments results in mixing between the HTFS and LTFS, which might be one of the most key reasons for gold precipitation and large-scale mineralization. The ore-forming fluids are characterized by high-temperature, strong-activity, and superimposed mineralization, so that there is a great probability of forming large and rich ore deposit in the Damoqujia gold deposit. The main bodies are preserved and extend toward deeper parts, thereby suggesting a great potential in future.
文摘The effect of arc on radiation thermometry is analyzed in a field close to the arc during the welding process, and the ratio of signal to noise and other factors are obtained for a small current arc .The method of the temperature measurement is feasible when the arc current is decreased to a smaller value in the welding process.
文摘In order to overcome the effect of the assumption between emissivity and wavelength on the measurement of true temperature and spectral emissivity for most engineering materials, a neural network based method is proposed for data processing while a blackbody furnace and three optical filters with known spectral transmittance curves were used to make up a true target. The experimental results show that the calculated temperatures are in good agreement with the temperature of the blackbody furnace, and the calculated spectral emissivity curves are in good agreement with the spectral transmittance curves of the filters. The method proposed has been proved to be an effective method for solving the problem of true temperature and emissivity measurement, and it can overcome the effect of the assumption between emissivity and wavelength on the measurement of true temperature and spectral emissivity for most engineering materials.
基金This project is supported by Provincial Natural Science Foundation of Zhejiang of China (No.599026).
文摘Based on the development of the non-contact measurement system of free-formsurface, NURBS reconstruction of measurement points of freeform surface is effectively realized bymodifying the objective function and recursive procedure and calculating the optimum number ofcontrol points. The reconstruction precision is evaluated through Ja-cobi's transformation method.The feasibility of the measurement system and effectiveness of the reconstruction algorithm aboveare proved by experiment.
文摘At present, an automatic-mechanic contact tap-changer is widely used in power system, but it can not frequently operate. In addition, arc will occur when the switch changes. In order to solve these two problems, this paper presented an automatic on-load voltage-regulating distributing transformer which employed non-contact solid-state relay as tap-changer, and mainly introduced its structure, basic principal, design method of each key link and experimental results. Laboratory simulation experiments informed that the scheme was feasible. It was a smooth and effective experiment device, which was practical in application.
基金partially supported by the National Natural Science Foundation of China(Grants 11532009,11372243,and 11522219)the China Postdoctoral Science Foundation(Grant 2016M602810)This project was also supported by the Initiative Postdocs Supporting Program(Grant BX201600121)
文摘Many structures and materials in nature and physiology have important "meso-scale" structures at the micron lengthscale whose tensile responses have proven difficult to characterize mechanically. Although techniques such as atomic force microscopy and micro- and nano-identation are mature for compression and indentation testing at the nano-scale, and standard uniaxial and shear rheometry techniques exist for the macroscale, few techniques are applicable for tensile-testing at the micrometre-scale, leaving a gap in our understanding of hierarchical biomaterials. Here, we present a novel magnetic mechanical testing (MMT) system that enables viscoelastic tensile testing at this critical length scale. The MMT system applies non-contact loading, avoiding gripping and surface interaction effects. We demonstrate application of the MMT system to the first analyses of the pure tensile responses of several native and engineered tissue systems at the mesoscale, showing the broad potential of the system for exploring micro- and meso-scale analysis of structured and hierarchical biological systems.
文摘A precise aperture measuring system of small deep holes with capacitance sensors is presented. Based on the working principle of non-contact capacitance sensors, influence of the edge effect of gauge head is studied, and one capacitance sensor for measuring the aperture of the small blind holes or through holes is introduced. The system is composed of one positioning device, one aperture measuring capacitance sensor, one measuring circuit, and software. This system employs visual CCD and two-dimensional mic...
文摘Non-contact sensing can be a rapid and convenient alternative for determining structure response compared to conventional instrumentation.Computer vision has been broadly implemented to enable accurate non-contact dynamic response measurements for structures.This study has analyzed the effect of non-contact sensors,including type,frame rate,and data collection platform,on the performance of a novel motion detection technique.Video recordings of a cantilever column were collected using a high-speed camera mounted on a tripod and an unmanned aerial system(UAS)equipped with visual and thermal sensors.The test specimen was subjected to an initial deformation and released.Specimen acceleration data were collected using an accelerometer installed on the cantilever end.The displacement from each non-contact sensor and the acceleration from the contact sensor were analyzed to measure the specimen′s natural frequency and damping ratio.The specimen′s first fundamental frequency and damping ratio results were validated by analyzing acceleration data from the top of the specimen and a finite element model.
文摘The severe acute respiratory syndrome coronavirus 2(SARS-CoV-2),which caused the coronavirus disease 2019(COVID-19)pandemic,has affected more than 400 million people worldwide.With the recent rise of new Delta and Omicron variants,the efficacy of the vaccines has become an important question.The goal of various studies has been to limit the spread of the virus by utilizing wireless sensing technologies to prevent human-to-human interactions,particularly for healthcare workers.In this paper,we discuss the current literature on invasive/contact and non-invasive/noncontact technologies(including Wi-Fi,radar,and software-defined radio)that have been effectively used to detect,diagnose,and monitor human activities and COVID-19 related symptoms,such as irregular respiration.In addition,we focused on cutting-edge machine learning algorithms(such as generative adversarial networks,random forest,multilayer perceptron,support vector machine,extremely randomized trees,and k-nearest neighbors)and their essential role in intelligent healthcare systems.Furthermore,this study highlights the limitations related to non-invasive techniques and prospective research directions.
基金supported by the National Natural Science Foundation of China(5170532751805329)+1 种基金Fundamental Research Funds for the Central Universities of China(NS2020065)the Natural Science Foundation of Shanghai(19ZR1453300).
文摘A novel non-contact spacecraft architecture with the extended stochastic state observer for disturbance rejection control of the gravity satellite is proposed.First,the precise linear driving non-contact voice-coil actuators are used to separate the whole spacecraft into the non-contact payload module and the service module,and to build an ideal loop with precise dynamics for disturbance rejection control of the payload module.Second,an extended stochastic state observer is enveloped to construct the overall nonlinear external terms and the internal coupled terms of the payload module,enabling the controller design of the payload module turned into the linear form with simple bandwidth-parameterization tuning in the frequency domain.As a result,the disturbance rejection control of the payload module can be explicitly achieved in a timely manner without complicated tuning in actual implementation.Finally,an extensive numerical simulation is conducted to validate the feasibility and effectiveness of the proposed approach.
文摘This study aimed to produce a prototype system for non-contact vital sign monitoring of the elderly using microwave radar with the intention of reducing the burdens on monitored individuals and nursing caregivers. In addition, we tested the ability of the proposed prototype system to measure the respiratory and heart rates of the elderly in a nursing home and discussed the systems effectiveness and problems by examining results of real-time monitoring. The prototype system consisted of two 24-GHz microwave radar antennas and an analysis system. The antennas were positioned below a mattress to monitor motion on the body surface for measuring cardiac and respiratory rates from the dorsal side of the subjects (23.3 ± 1.2 years) who would be lying on the mattress. The heart rates determined by the prototype system correlated significantly with those measured by electrocardiography (r = 0.92). Similarly, the respiratory rates determined by the prototype correlated with those obtained from respiration curves (r = 0.94). Next, we investigated the effectiveness of the prototype system with 7 elderly patients (93.3 ± 10.56 years) at a nursing home. The proposed system appears to be a promising tool for monitoring the vital signs of the elderly in a way that alleviates the need to attach electrodes overnight to confirm patient safety.
基金supported by the National Natural Science Foundation of China(10772086 and 10727201)the National University of Singapore(R-265-000-140-112)
文摘This paper presents a novel non-contact method for evaluating the resonant frequency of a microstructure, Firstly, the microstructure under test is excited by ultrasonic waves. This excitation method does not impose any undefined load on the specimen like the electrostatic excitation and also this is the first actual use of ultrasonic wave for exciting a microstructure in the literature. Secondly, the amplitudes of the microstructure are determined by image edge detection using a Mexican hat wavelet transform on the vibrating images of the microstructure. The vibrating images are captured by a CCD camera when the microstructure is vibrated by ultrasonic waves at a series of discrete high frequencies (〉30 kHz). Upon processing the vibrating images, the amplitudes at various excitation frequencies are obtained and an amplitude-frequency spectrum is obtained from which the resonant frequency is subsequently evaluated. A micro silicon structure consisting of a perforated plate (192 × 192 μm) and two cantilever beams (76 × 43 μm) which is about 4 μm thickness is tested. Since laser interferometry is not required, thermal effects on a test object can be avoided. Hence, the setup is relatively simple. Results show that the proposed method is a simple and effective approach for evaluating the dynamic characteristics of microstructures.
基金Supported by Defense Industrial Technology Development Program(B2220110013)
文摘Aiming at the estimation of personal injury attached by counter-terrorist door breaching explosive blast wave, according to the actual scene, four typical application space models of count- er-terrorist door breaching explosives are established, and numerical simulation of air-blast wave propagation by non-contact explosion counter-terrorist door breaching explosive are achieved. The research results show that the overpressure behind the target door is attenuated deeply through the burglary resistant safety door, and the propagation of blast wave and the damage effect under differ- ent space conditions are obviously different.
文摘Image photoplethysmography can realize low-cost and easy-to-operate non-contact heart rate detection from the facial video, and effectively overcome the limitations of traditional contact method in daily vital sign monitoring. However, it is hard to obtain more accurate heart rate detection values under the conditions of subject’s facial movement, weak ambient light intensity and long detection distance, etc. In this article, a non-contact heart rate detection method based on face tracking is proposed, which can effectively improve the accuracy of non-contact heart rate detection method in practical application. The corner tracker algorithm is used to track the human face to reduce the motion artifact caused by the movement of the subject’s face and enhance the use value of the signal. And the maximum ratio combining algorithm is used to weight the pixel space pulse wave signal in the facial region of interest to improve the pulse wave extraction accuracy. We analyzed the facial images collected under different experimental distances and action states. This proposed method significantly reduces the error rate compared with the independent component analysis method. After theoretical analysis and experimental verification, this method effectively reduces the error rate under different experimental variables and has good consistency with the heart rate value collected by the medical physiological vest. This method will help to improve the accuracy of non-contact heart rate detection in complex environments.
基金Project(2000G033) supported by the S & T, Ministry of Railroad , China
文摘It is very important to monitor surrounding rock deformation in tunnel construction. The principle, function, development and application of the system composed of a total station and computer for monitoring and analyzing surrounding rock deformation were discussed. The new methods of two free station of 3D measurement and its mathematic adjustment mode were presented. The development of software for total station on-board and post for computer were also described. Without centering it and measuring its height, the total station controlled by the software on-board can fulfill the whole measurements to target points. Monitoring data can be processed by the post software and results of regression analysis, forecasting information of the tunnel surrounding rock deformation can be provided in time. The practical use shows that this system is practicable, highly accurate and efficient. It satisfies the needs of safety and information construction in tunnel construction of underground engineering.