期刊文献+
共找到71篇文章
< 1 2 4 >
每页显示 20 50 100
Development of a toroidal soft x-ray imaging system and application for investigating three-dimensional plasma on J-TEXT
1
作者 赵传旭 李建超 +9 位作者 张晓卿 王能超 丁永华 杨州军 江中和 严伟 李杨波 毛飞越 任正康 the J-TEXT Team 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第3期94-99,共6页
A toroidal soft x-ray imaging(T-SXRI)system has been developed to investigate threedimensional(3D)plasma physics on J-TEXT.This T-SXRI system consists of three sets of SXR arrays.Two sets are newly developed and locat... A toroidal soft x-ray imaging(T-SXRI)system has been developed to investigate threedimensional(3D)plasma physics on J-TEXT.This T-SXRI system consists of three sets of SXR arrays.Two sets are newly developed and located on the vacuum chamber wall at toroidal positionsφof 126.4°and 272.6°,respectively,while one set was established previously atφ=65.50.Each set of SXR arrays consists of three arrays viewing the plasma poloidally,and hence can be used separately to obtain SXR images via the tomographic method.The sawtooth precursor oscillations are measured by T-SXRI,and the corresponding images of perturbative SXR signals are successfully reconstructed at these three toroidal positions,hence providing measurement of the 3D structure of precursor oscillations.The observed 3D structure is consistent with the helical structure of the m/n=1/1 mode.The experimental observation confirms that the T-SXRI system is able to observe 3D structures in the J-TEXT plasma. 展开更多
关键词 SXR imaging J-TEXT tokamak three-dimensional measurement MHD
下载PDF
Volumetric measurement techniques for assessment of cutaneous neurofibromas:A review
2
作者 Xinyu Wang Jiayi Xu +2 位作者 Yun Zhu Chengjiang Wei Zhichao Wang 《Chinese Journal of Plastic and Reconstructive Surgery》 2024年第2期83-86,共4页
Cutaneous neurofibroma(cNF)is a prevalent clinical manifestation of neurofibromatosis type 1,significantly affecting the well-being and quality of life of the affected individuals.The adoption of reliable and reproduc... Cutaneous neurofibroma(cNF)is a prevalent clinical manifestation of neurofibromatosis type 1,significantly affecting the well-being and quality of life of the affected individuals.The adoption of reliable and reproducible volumetric measurement techniques is essential for precisely evaluating tumor burden and plays a critical role in the development of effective treatments for cNF.This study focuses on widely used volumetric measurement techniques,including vernier calipers,ultrasound,computed tomography,magnetic resonance imaging,and three-dimensional scanning imaging.It outlines the merits and drawbacks of each technique in assessing the cNF load,providing an overview of their current applications and ongoing research advancements in this domain. 展开更多
关键词 Cutaneous neurofibroma Tumor volume measurement Vernier caliper Ultrasound Computed tomography Magnetic resonance imaging three-dimensional scanning imaging
下载PDF
Multi-objective strategy to optimize dithering technique for high-quality three-dimensional shape measurement 被引量:2
3
作者 Ning Cai Zhe-Bo Chen +1 位作者 Xiang-Qun Cao Bin Lin 《Chinese Physics B》 SCIE EI CAS CSCD 2019年第10期381-386,共6页
Dithering optimization techniques can be divided into the phase-optimized technique and the intensity-optimized technique. The problem with the former is the poor sensitivity to various defocusing amounts, and the pro... Dithering optimization techniques can be divided into the phase-optimized technique and the intensity-optimized technique. The problem with the former is the poor sensitivity to various defocusing amounts, and the problem with the latter is that it cannot enhance phase quality directly nor efficiently. In this paper, we present a multi-objective optimization framework for three-dimensional(3D) measurement by utilizing binary defocusing technique. Moreover, a binary patch optimization technique is used to solve the time-consuming issue of genetic algorithm. It is demonstrated that the presented technique consistently obtains significant phase performance improvement under various defocusing amounts. 展开更多
关键词 three-dimensional(3D) SHAPE measurement MULTI-OBJECTIVE dithering GENETIC algorithm
下载PDF
Three-Dimensional Measurement and Reconstruction of Fabric Drape Shape 被引量:1
4
作者 沈毅 尹红媛 刘玄木 《Journal of Donghua University(English Edition)》 EI CAS 2007年第1期39-42,共4页
This paper introduces a new method of measuring the three-dimensional drape shape of fabrics with structural light. First, we apply parallel annular structural light to form light and shade alternating contour stripes... This paper introduces a new method of measuring the three-dimensional drape shape of fabrics with structural light. First, we apply parallel annular structural light to form light and shade alternating contour stripes on the surface of fabrics. We then collect the images of contour stripes using Charge Coupled Device (CCD). Subsequently, we process the images to identify the contour stripes and edges of fabrics, and obtain the fabric contour lines of curved surfaces. Finally, we apply three-dimensional curved surface modeling method based on a network of polar coordinates, and reconstruct the three-dimensional drape shape of fabrics. Experiments show that our method is effective in testing and reconstructing three-dimensional drape shape of fabrics. 展开更多
关键词 fabric drape non-contact measurement structurelight image process three-dimension reconstruction.
下载PDF
Evaluating the contribution of satellite measurements to the reconstruction of three-dimensional ocean temperature fields in combination with Argo profiles 被引量:1
5
作者 Jian Chen Hengqian Yan +3 位作者 Senliang Bao Xindong Cui Chengzu Bai Huizan Wang 《Acta Oceanologica Sinica》 SCIE CAS CSCD 2022年第2期65-79,共15页
Assimilation systems absorb both satellite measurements and Argo observations.This assimilation is essential to diagnose and evaluate the contribution from each type of data to the reconstructed analysis,allowing for ... Assimilation systems absorb both satellite measurements and Argo observations.This assimilation is essential to diagnose and evaluate the contribution from each type of data to the reconstructed analysis,allowing for better configuration of assimilation parameters.To achieve this,two comparative reconstruction schemes were designed under the optimal interpolation framework.Using a static scheme,an in situ-only field of ocean temperature was derived by correcting climatology with only Argo profiles.Through a dynamic scheme,a synthetic field was first derived from only satellite sea surface height and sea surface temperature measurements through vertical projection,and then a combined field was reconstructed by correcting the synthetic field with in situ profiles.For both schemes,a diagnostic iterative method was performed to optimize the background and observation error covariance statics.The root mean square difference(RMSD)of the in situ-only field,synthetic field and combined field were analyzed toward assimilated observations and independent observations,respectively.The rationale behind the distribution of RMSD was discussed using the following diagnostics:(1)The synthetic field has a smaller RMSD within the global mixed layer and extratropical deep waters,as in the Northwest Pacific Ocean;this is controlled by the explained variance of the vertical surface-underwater regression that reflects the ocean upper mixing and interior baroclinicity.(2)The in situ-only field has a smaller RMSD in the tropical upper layer and at midlatitudes;this is determined by the actual noise-to-signal ratio of ocean temperature.(3)The satellite observations make a more significant contribution to the analysis toward independent observations in the extratropics;this is determined by both the geographical feature of the synthetic field RMSD(smaller at depth in the extratropics)and that of the covariance correlation scales(smaller in the extratropics). 展开更多
关键词 satellite measurements ARGO three-dimensional reconstruction ocean temperature
下载PDF
Application of Three-dimensional Body Measurement System 被引量:1
6
作者 李俊 柳素燕 张芸 《Journal of Donghua University(English Edition)》 EI CAS 2005年第4期134-138,共5页
The configuration principles and functions of the non-contact three-dimensional (3D) body measurement system (BMS) developed by the Textile/Clothing Technology Corporation ([TC]^2) are described in this paper. T... The configuration principles and functions of the non-contact three-dimensional (3D) body measurement system (BMS) developed by the Textile/Clothing Technology Corporation ([TC]^2) are described in this paper. The advantages of this new system, compared with traditional contact body measurement instruments ( Martin instruments ) are discussed by selecting 40 female undergraduates of Donghna University as the scan objects. In the experiments both the Martin instruments and [TC]^2 BMS were used respectively. According to the data of different position (Bust Circumference, Full Waist, Full Hips, Bust Height, Front Waist Height and Back Waist Height) obtained from both of the methods we can get the correlation coefficient which is close to 1, indicating that the results of both methods have comparability. Finally some suggestions for the further applications of the non-contact BMS in the apparel development of China are given. 展开更多
关键词 Body measurement ANTHROPOMETRY non-contact 3D body measurement system apparel industry made-to-measure (MTM)
下载PDF
A method for phase reconstruction in optical three-dimensional shape measurement
7
作者 乔闹生 贺志 《Chinese Physics B》 SCIE EI CAS CSCD 2012年第9期267-270,共4页
In optical three-dimensional shape measurement, a method of improving the measurement precision for phase reconstruction without phase unwrapping is analyzed in detail. Intensities of any five consecutive pixels that ... In optical three-dimensional shape measurement, a method of improving the measurement precision for phase reconstruction without phase unwrapping is analyzed in detail. Intensities of any five consecutive pixels that lie in the x-axis direction of the phase domain are given. Partial derivatives of the phase function in the x- and y-axis directions are obtained with a phase-shifting mechanism, the origin of which is analysed. Furthermore, to avoid phase unwrapping in the phase reconstruction, we derive the gradient of the phase function and perform a two-dimensional integral along the x- and y-axis directions. The reconstructed phase can be obtained directly by performing numerical integration, and thus it is of great convenience for phase reconstruction. Finally, the results of numerical simulations and practical experiments verify the correctness of the proposed method. 展开更多
关键词 phase reconstruction optical three-dimensional shape measurement measurement pre-cision
下载PDF
A fast and precise three-dimensional measurement system based on multiple parallel line lasers
8
作者 Yao Wang Bin Lin 《Chinese Physics B》 SCIE EI CAS CSCD 2021年第2期276-284,共9页
This paper conducts a trade-off between efficiency and accuracy of three-dimensional(3 D)shape measurement based on the triangulation principle,and introduces a flying and precise 3 D shape measurement method based on... This paper conducts a trade-off between efficiency and accuracy of three-dimensional(3 D)shape measurement based on the triangulation principle,and introduces a flying and precise 3 D shape measurement method based on multiple parallel line lasers.Firstly,we establish the measurement model of the multiple parallel line lasers system,and introduce the concept that multiple base planes can help to deduce the unified formula of the measurement system and are used in simplifying the process of the calibration.Then,the constraint of the line spatial frequency,which maximizes the measurement efficiency while ensuring accuracy,is determined according to the height distribution of the object.Secondly,the simulation analyzing the variation of the systemic resolution quantitatively under the circumstance of a set of specific parameters is performed,which provides a fundamental thesis for option of the four system parameters.Thirdly,for the application of the precision measurement in the industrial field,additional profiles are acquired to improve the lateral resolution by applying a motor to scan the 3 D surface.Finally,compared with the line laser,the experimental study shows that the present method of obtaining 41220 points per frame improves the measurement efficiency.Furthermore,the accuracy and the process of the calibration are advanced in comparison with the existing multiple-line laser and the structured light makes an accuracy better than 0.22 mm at a distance of 956.02 mm. 展开更多
关键词 three-dimensional shape measurement multiple parallel line lasers fast and precise measurement parameter calibration
下载PDF
Three-Dimensional Velocity Distribution Measurement Using Ultrasonic Velocity Profiler with Developed Transducer
9
作者 Naruki Shoji Hiroshige Kikura +1 位作者 Hideharu Takahashi Wongsakorn Wongsaroj 《Journal of Flow Control, Measurement & Visualization》 2022年第1期32-55,共24页
This study describes an ultrasonic velocity profiler that uses a <span style="white-space:normal;"><span style="font-family:;" "="">new ultrasonic array transducer with u... This study describes an ultrasonic velocity profiler that uses a <span style="white-space:normal;"><span style="font-family:;" "="">new ultrasonic array transducer with unique 5-element configuration</span></span><span style="white-space:normal;"><span style="font-family:;" "="">, with all five elements acting as transmitters and four elements as receivers. The receivers are designed to reduce the amount of uncertainty. As the fluid moves through this setup, four Doppler frequencies are obtained. The multi-dimensional velocity information along the measurement line can be reconstructed. The transducer has a compact geometry suitable for a wide range of applications, including narrow flow areas. The transducer’s basic frequency and sound pressure are selected and evaluated to be compatible with the application. First, to confirm the measurement ability, the measurement of the developed system in two-dimensional flow is validated by comparing it to the theoretical data. The uncertainty of measurement was within 15%. Second, the three-dimensional measurement in turbulent and swirling flow is proved experimentally to check the applicability of the proposed technique.</span></span> 展开更多
关键词 Doppler Frequency Liquid Velocity three-dimensional measurement Transducer Design ULTRASONIC
下载PDF
Digital measurement of bone tumor volume by CT three-dimensional reconstruction technology
10
作者 胡永成 《外科研究与新技术》 2011年第2期125-125,共1页
Objective To discuss the measurement of bone tumor volume on the basis of three dimensional images segmentation technology. Methods Twenty patients with lacunar bone tumor from Tianjin Hospital and Tongji Hospital wer... Objective To discuss the measurement of bone tumor volume on the basis of three dimensional images segmentation technology. Methods Twenty patients with lacunar bone tumor from Tianjin Hospital and Tongji Hospital were included in the 展开更多
关键词 BONE Digital measurement of bone tumor volume by CT three-dimensional reconstruction technology CT
下载PDF
NON-CONTACT MEASUREMENT SYSTEM OF FREEFORM SURFACE AND NURBS RECONSTRUCTION OF MEASUREMENT POINTS 被引量:4
11
作者 Li Jian Wang Wen Chen Zichen Institute of Advanced Manufacturing Engineering, Zhejiang University, Hangzhou 310027, China 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2002年第4期366-371,共6页
Based on the development of the non-contact measurement system of free-formsurface, NURBS reconstruction of measurement points of freeform surface is effectively realized bymodifying the objective function and recursi... Based on the development of the non-contact measurement system of free-formsurface, NURBS reconstruction of measurement points of freeform surface is effectively realized bymodifying the objective function and recursive procedure and calculating the optimum number ofcontrol points. The reconstruction precision is evaluated through Ja-cobi's transformation method.The feasibility of the measurement system and effectiveness of the reconstruction algorithm aboveare proved by experiment. 展开更多
关键词 freeform surface non-contact measurement NURBS precision evaluation
下载PDF
Three-Dimensional Analytical Modeling of Axial-Flux Permanent Magnet Drivers
12
作者 Wenhui Li Dazhi Wang +3 位作者 Shuo Cao Deshan Kong Sihan Wang Zhong Hua 《Computers, Materials & Continua》 SCIE EI 2023年第4期259-276,共18页
In this paper, the axial-flux permanent magnet driver is modeledand analyzed in a simple and novel way under three-dimensional cylindricalcoordinates. The inherent three-dimensional characteristics of the deviceare co... In this paper, the axial-flux permanent magnet driver is modeledand analyzed in a simple and novel way under three-dimensional cylindricalcoordinates. The inherent three-dimensional characteristics of the deviceare comprehensively considered, and the governing equations are solved bysimplifying the boundary conditions. The axial magnetization of the sectorshapedpermanent magnets is accurately described in an algebraic form bythe parameters, which makes the physical meaning more explicit than thepurely mathematical expression in general series forms. The parameters of theBessel function are determined simply and the magnetic field distribution ofpermanent magnets and the air-gap is solved. Furthermore, the field solutionsare completely analytical, which provides convenience and satisfactoryaccuracy for modeling a series of electromagnetic performance parameters,such as the axial electromagnetic force density, axial electromagnetic force,and electromagnetic torque. The correctness and accuracy of the analyticalmodels are fully verified by three-dimensional finite element simulations and a15 kW prototype and the results of calculations, simulations, and experimentsunder three methods are highly consistent. The influence of several designparameters on magnetic field distribution and performance is studied and discussed.The results indicate that the modeling method proposed in this papercan calculate the magnetic field distribution and performance accurately andrapidly, which affords an important reference for the design and optimizationof axial-flux permanent magnet drivers. 展开更多
关键词 three-dimensional analytical modeling cylindrical coordinates magnetic field distribution parameter sensitivity analysis performance measurement
下载PDF
Development of a Three-Dimensional Measuring System for Neonates' Head and Facial Morphology 被引量:1
13
作者 邓咏梅 易洁伦 +2 位作者 郭绮莲 黄小珍 吴新培 《Journal of Donghua University(English Edition)》 EI CAS 2007年第3期309-312,共4页
A web camera based multi-camera convergent close-range photogrammetric system is developed to obtain the neonates' head and facial morphology. The data will then be used to develop a secure and good-fitting eye-patch... A web camera based multi-camera convergent close-range photogrammetric system is developed to obtain the neonates' head and facial morphology. The data will then be used to develop a secure and good-fitting eye-patch protector for neonates, particularly whoa they are exposed to bright lights such as phototherapy light. Measurements obtained by the system are evaluated and validated against data obtained from optical scanning. Results show that the photogrammetric system meets the requirements of measuring accuracy and safety for neonate in the neonatal units. 展开更多
关键词 close-range photogrammetry (CRP) three-dimensional measurement NEONATES head and facialmorphology
下载PDF
Non-contact measurement and multi-objective analysis of drilling temperature when drilling B_4C reinforced aluminum composites
14
作者 A.TASKESEN K.KUTUKDE 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2015年第1期271-283,共13页
Non-contact measurements of machining temperatures were performed with optical pyrometer when drilling particle(B4C) reinforced metal matrix composites(MMCs) with different drills. The effect of particle content, ... Non-contact measurements of machining temperatures were performed with optical pyrometer when drilling particle(B4C) reinforced metal matrix composites(MMCs) with different drills. The effect of particle content, cutting speed, feed rate and tool material on the maximum drilling temperature was investigated. The drilling parameters were optimized based on multiple performance characteristics in terms of the maximum cutting temperature and tool wear. According to the results, the most influential control factors on the cutting temperatures are found to be particle fraction, feed rate and interaction between the cutting speed and particle content, respectively. The influences of the cutting speed and drill material on the drilling temperature are found to be relatively lower for the used range of parameters. Minimum cutting temperatures are obtained with lower particle fraction and cutting speed, with relatively higher feed rates and carbide tools. The results reveal that optimal combination of the drilling parameters can be used to obtain both minimum cutting temperature and tool wear. 展开更多
关键词 metal matrix composite drilling temperature WEAR non-contact measurement grey relation
下载PDF
Diameters and form of skull base foramen ovale measured by three-dimensional spiral CT thin-slice scan in healthy adults
15
作者 Xiaohua Chen Fengxian Deng +1 位作者 Shuhang Wei Tingsong Fang 《Neural Regeneration Research》 SCIE CAS CSCD 2006年第4期343-346,共4页
BACKGROUND: The accurate measurements of various data of the bone diameters of foramen ovale of living person can change the methods of puncturing trigeminal gasserian ganglion via foramen ovale for treating trifacia... BACKGROUND: The accurate measurements of various data of the bone diameters of foramen ovale of living person can change the methods of puncturing trigeminal gasserian ganglion via foramen ovale for treating trifacial neuralgia from the experience of puncture operator only to puncture by taking the objective data of measurement as the evidence, which is good for improving the accuracy of puncturing trigeminal ganglion and reducing side effects. OBJECTIVE : To observe the forms of foramen ovales in healthy adults displayed by volume rendering and multi-planar reconstruction after three-dimensional spiral CT thin-slice scan of skull base, and measure the longitudinal diameter and transverse diameter. DESIGN : A repetitive observation and measurement SETTINGS : Department of Neurosurgery and Department of Medical Imaging, Foshan Hospital of Traditional Chinese Medicine. PARTICIPANTS: Fifty healthy adults (100 sides), who were examined with three-dimensional spiral CT scan, were randomly selected from the Department of Medical Imaging, Foshan Hospital of Traditional Chinese Medicine from January 2005 to January 2006, including 26 males and 24 females, aged 25-68 years with an average of 48 years old. They were all informed and agreed with the examination. METHODS : The subjects were examined with the Philips 16-slice spiral CT-Mx 8000 IDT CT apparatus (Philips Company, Holland), the scanning ranged from 2 cm below the canthomeatal line to the level of suprasellar cistem. The width of collimator was 0.75 mm, pitch was 0.663; tube current was 350 mA, voltage was 120 kV, resolution was 512×512 matrix; slice thickness of reconstruction was 1 mm, and interval was 0.5 mm. After the three-dimensional spiral CT thin-slice scan of skull base, the image post-processing techniques including volume rendering and multi-planar reconstruction were applied to observe the forms of foramen ovales, and measure the size, longitudinal diameter and transverse diameter of the foramen ovales. The figures of the foramen ovales were drawn with mouse along the boundary of bone porous margin and soft tissue. According to the indications, the diameters were measured with computer to observe the forms of foramen ovales. MAIN OUTCOME MEASURES : The longitudinal diameter, transverse diameter and form of foramen ovales were observed. RESULTS: All the 50 healthy adults (100 sides) were involved in the analysis of results. (1) It was observed in the volume rendering images that foramen ovales had four forms of oval shape (77 sides), kidney shape (12 sides), round shape (7 sides), ribbon shape (4 sides). (2) The longitudinal diameters of left and right foramen ovales were (7.67±1.32) and (7.98±1.45) mm, and the transverse diameters were (4.04±0.83), (4.09±1.07) mm; There was no obvious difference between left and right longitudinal diameters (t = 1.63, P = 0.11 ), and left and right transverse diameters were close (t = 0.45, P= 0.65). CONCLUSION : The non-invasive techniques of volume rendering and multi-planar reconstruction after three-dimensional spiral CT thin-slice scan can clearly display the formand size of foramen ovale in healthy adults. 展开更多
关键词 Diameters and form of skull base foramen ovale measured by three-dimensional spiral CT thin-slice scan in healthy adults CT base
下载PDF
Machine Vision for Non-Contact Automated Countersink Measurement
16
作者 LIANG Ying WU Xiaowei +3 位作者 JIA Chunning YU Long YE Shunjian LE Bin 《Aerospace China》 2022年第3期32-37,共6页
The slug rivet is widely used in wing assembly due to its longer fatigue life and better sealing performance compared with other connection technologies.As a countersink with dual-angle is widely adopted for this type... The slug rivet is widely used in wing assembly due to its longer fatigue life and better sealing performance compared with other connection technologies.As a countersink with dual-angle is widely adopted for this type of connection,the countersink diameter and depth are key factors that affect assembly quality.Therefore,it is of great importance to efficiently inspect the countersink quality to ensure high accuracy.However,contact measurements are susceptible to the loss of accuracy due to cutting debris and lube build-up,while the hole-scanning method using laser profilometry is time consuming and complex.In this paper,a non-contact method for countersink diameter and depth measurement based on a machine vision system is proposed.The countersink diameter can be directly measured by the machine vision system,while the countersink depth is determined through the countersink diameter indirectly.First,by means of image processing technology together with an improved edge detection algorithm,the countersink diameter can be obtained.Then,a 3D microscope is employed to measure the countersink depth,which helps to model the countersink.As a result,once the countersink diameter is measured,so is the depth.The experimentation demonstrated that this method has strong feasibility and enables time saving,which is conducive to improve the riveting efficiency. 展开更多
关键词 machine vision non-contact measurement countersink
下载PDF
A LASER-SCANNING NON-CONTACT MEASURING METHOD FOR ROUNDNESS ERRORS 被引量:1
17
作者 宋甲午 张国玉 +3 位作者 安志勇 李成志 景红薇 高玉军 《兵工学报》 EI CAS CSCD 北大核心 2000年第1期-,共3页
利用激光狭缝扫描原理和光电传感技术,提出了一种用于测量大型回转体类零件圆度误差的激光扫描非接触测量方法和测量系统。本文详细论述了测量系统及其测量原理、工件安装偏心误差的分离技术和计算机实时数据处理系统,实验结果证实了... 利用激光狭缝扫描原理和光电传感技术,提出了一种用于测量大型回转体类零件圆度误差的激光扫描非接触测量方法和测量系统。本文详细论述了测量系统及其测量原理、工件安装偏心误差的分离技术和计算机实时数据处理系统,实验结果证实了这种测量方法的可行性。 展开更多
关键词 圆度误差 激光狭缝扫描 非接触测量 偏心误差 A LASER-SCANNING non-contact measurING
下载PDF
Accurate Measurement Method for Tube's Endpoints Based on Machine Vision 被引量:10
18
作者 LIU Shaoli JIN Peng +2 位作者 LIU Jianhua WANG Xiao SUN Peng 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2017年第1期152-163,共12页
Tubes are used widely in aerospace vehicles, and their accurate assembly can directly affect the assembling reliability and the quality of products. It is important to measure the processed tube's endpoints and then ... Tubes are used widely in aerospace vehicles, and their accurate assembly can directly affect the assembling reliability and the quality of products. It is important to measure the processed tube's endpoints and then fix any geometric errors correspondingly. However, the traditional tube inspection method is time-consuming and complex operations. Therefore, a new measurement method for a tube's endpoints based on machine vision is proposed. First, reflected light on tube's surface can be removed by using photometric linearization. Then, based on the optimization model for the tube's endpoint measurements and the principle of stereo matching, the global coordinates and the relative distance of the tube's endpoint are obtained. To confirm the feasibility, ll tubes are processed to remove the reflected light and then the endpoint's positions of tubes are measured. The experiment results show that the measurement repeatability accuracy is 0.167 mm, and the absolute accuracy is 0.328 ram. The measurement takes less than 1 min. The proposed method based on machine vision can measure the tube's endpoints without any surface treatment or any tools and can realize on line measurement. 展开更多
关键词 machine vision non-contact measurement reflection light tube endpoint measurement
下载PDF
Development of an In-Situ Laser Machining System Using a Three-Dimensional Galvanometer Scanner 被引量:6
19
作者 Xiao Li Bin Liu +3 位作者 Xuesong Mei Wenjun Wang Xiaodong Wang Xun Li 《Engineering》 SCIE EI 2020年第1期68-76,共9页
In this study, a three-dimensional (3D) in-situ laser machining system integrating laser measurement and machining was built using a 3D galvanometer scanner equipped with a side-axis industrial camera. A line structur... In this study, a three-dimensional (3D) in-situ laser machining system integrating laser measurement and machining was built using a 3D galvanometer scanner equipped with a side-axis industrial camera. A line structured light measurement model based on a galvanometer scanner was proposed to obtain the 3D information of the workpiece. A height calibration method was proposed to further ensure measurement accuracy, so as to achieve accurate laser focusing. In-situ machining software was developed to realize time-saving and labor-saving 3D laser processing. The feasibility and practicability of this in-situ laser machining system were verified using specific cases. In comparison with the conventional line structured light measurement method, the proposed methods do not require light plane calibration, and do not need additional motion axes for 3D reconstruction;thus they provide technical and cost advantages. The insitu laser machining system realizes a simple operation process by integrating measurement and machining,which greatly reduces labor and time costs. 展开更多
关键词 In-situ laser machining three-dimensional galvanometer scanner Line structured light three-dimensional measurement
下载PDF
Deep-Hole Inner Diameter Measuring System Based on Non-contact Capacitance Sensor 被引量:3
20
作者 于永新 张恒 +1 位作者 王宗超 常以哲 《Transactions of Tianjin University》 EI CAS 2010年第6期447-451,共5页
A precise aperture measuring system of small deep holes with capacitance sensors is presented. Based on the working principle of non-contact capacitance sensors, influence of the edge effect of gauge head is studied, ... A precise aperture measuring system of small deep holes with capacitance sensors is presented. Based on the working principle of non-contact capacitance sensors, influence of the edge effect of gauge head is studied, and one capacitance sensor for measuring the aperture of the small blind holes or through holes is introduced. The system is composed of one positioning device, one aperture measuring capacitance sensor, one measuring circuit, and software. This system employs visual CCD and two-dimensional mic... 展开更多
关键词 deep-hole measurement non-contact CCD stepping motor precise positioning
下载PDF
上一页 1 2 4 下一页 到第
使用帮助 返回顶部